PubMed Health⌕ Search

Biomedical subjects

Remy Tumbar

Publications and source records attributed to Remy Tumbar.

2 recordsLinked to original sources

Aberrations induced in wavefront-guided laser refractive surgery due to shifts between natural and dilated pupil center locations.

PURPOSE: To determine the aberrations induced in wavefront-guided laser refractive surgery due to shifts in pupil center location from when aberrations are measured preoperatively (over a dilated pupil) to when they are corrected surgically (over a natural pupil). SETTING: Center for Visual Science and Department of Ophthalmology, University of Rochester, Rochester, New York, USA. METHODS: Shifts in pupil center were measured between dilated phenylephrine hydrochloride (Neo-Synephrine [2.5%]) and nonpharmacological mesopic conditions in 65 myopic eyes treated with wavefront-guided laser in situ keratomileusis (Technolas 217z, Bausch & Lomb). Each patient's preoperative and 6-month postoperative wave aberrations were measured over the dilated pupil. Aberrations theoretically induced by decentration of a wavefront-guided ablation were calculated and compared with those measured 6 months postoperatively (6.0 mm pupil). RESULTS: The mean magnitude of pupil center shift was 0.29 mm +/- 0.141 (SD) and usually occurred in the inferonasal direction as the pupil dilated. Depending on the magnitude of shift, the fraction of the higher-order postoperative root-mean-square wavefront error that could be due theoretically to pupil center decentrations was highly variable (mean 0.26 +/- 0.20 mm). There was little correlation between the calculated and 6-month postoperative wavefronts, most likely because pupil center decentrations are only 1 of several potential sources of postoperative aberrations. CONCLUSIONS: Measuring aberrations over a Neo-Synephrine-dilated pupil and treating them over an undilated pupil typically resulted in a shift of the wavefront-guided ablation in the superotemporal direction and an induction of higher-order aberrations. Methods referencing the aberration measurement and treatment with respect to a fixed feature on the eye will reduce the potential for inducing aberrations due to shifts in pupil center.

Adult↗

Sampling field sensor with anisotropic fan-out.

We describe a new common-path, phase-shift, and shearing interferometric device capable of single-shot detection of optical phase profiles. It samples the input field and uses birefringent plates to fan out phase-shifted copies of the samples in the empty space between them. The phase shifts are given by the thickness of the plates and not by the relative position of the components, as in classical interferometers. This makes the device insensitive to vibrations. We recorded repeatability better than lambda/100, even though strong shocks were applied to the air table in proximity to the system. We recorded better than lambda/1000 repeatability under quiet conditions and estimated the accuracy to be better than lambda/3000 at the shot-noise limit. In addition, the device is compact and easy to integrate in a variety of setups that require the measurement of optical phase profiles.

Journal Article↗