Segmental bone regeneration using a load-bearing biodegradable carrier of bone morphogenetic protein-2.

Segmental defect regeneration has been a clinical challenge. Current tissue-engineering approach using porous biodegradable scaffolds to delivery osteogenic cells and growth factors demonstrated success in facilitating bone regeneration in these cases. However, due to the lack of mechanical property, the porous scaffolds were evaluated in non-load bearing area or were stabilized with stress-shielding devices (bone plate or external fixation). In this paper, we tested a scaffold that does not require a bone plate because it has sufficient biomechanical strength. The tube-shaped scaffolds were manufactured from poly(propylene) fumarate/tricalcium phosphate (PPF/TCP) composites. Dicalcium phosphate dehydrate (DCPD) were used as bone morphogenetic protein-2 (BMP-2) carrier. Twenty-two scaffolds were implanted in 5mm segmental defects in rat femurs stabilized with K-wire for 6 and 15 weeks with and without 10 microg of rhBMP-2. Bridging of the segmental defect was evaluated first radiographically and was confirmed by histology and micro-computer tomography (microCT) imaging. The scaffolds in the BMP group maintained the bone length throughout the duration of the study and allow for bridging. The scaffolds in the control group failed to induce bridging and collapsed at 15 weeks. Peripheral computed tomography (pQCT) showed that BMP-2 does not increase the bone mineral density in the callus. Finally, the scaffold in BMP group was found to restore the mechanical property of the rat femur after 15 weeks. Our results demonstrated that the load-bearing BMP-2 scaffold can maintain bone length and allow successfully regeneration in segmental defects.

Animals↗

Effect of low molecular weight heparin on fracture healing in a stabilized rat femur fracture model.

The purpose of this study was to evaluate the effect of low molecular weight heparin (LMWH) on fracture healing in a standard stabilized rat femur fracture model. A closed, mid-diaphyseal transverse fracture was created in the right femur of Long-Evans rats after insertion of a 0.8-mm K-wire into the medullary canal. Animals were randomized to receive either LMWH (70 units/kg dalteparin) or an injection of normal saline daily for 2 weeks. Animals were sacrificed at 2, 3, and 6 weeks. Fracture healing was assessed by radiographs, histology, and mechanical testing. There were no significant differences between the control and LMWH groups in the percentage of animals with radiographic bridging callus at each time point. Histologic appearance of fracture healing was similar between the control and LMWH groups. There were no significant differences in the normalized mechanical properties of the control and LMWH groups at 2 and 3 weeks. At 6 weeks, the percent torque of the LMWH group was significantly greater than the control group ( p = 0.0072), however, there was no significant difference in the stiffness and energy absorption. Dalteparin, at the dosage used in this study, did not impair fracture healing in this standard stabilized rat femur fracture model.

Animals↗

Preliminary evaluation of a load-bearing BMP-2 carrier for segmental defect regeneration.

Large segmental defects in bones can result from tumor removal, massive trauma, congenital malformation, or non-union fractures. Such defects often are difficult to manage and require multiple-phase surgery to achieve adequate union and function. In this study, we propose a novel design of bone morphogenetic protein 2 (BMP-2) carrier for tissue engineering of segmental defect regeneration. The tube-shaped BMP-2 carrier was fabrication from a poly(propylene fumarate)/tricalcium phosphate (PPF/TCP) composite via casting technique developed in our laboratory. An in vitro evaluation showed that the compressive strength of the carrier decreased about 48% in 12 weeks while maintained a pH in the 6.8-7.4 range. In vivo study was conducted by implanting carriers loaded with 10 microg of BMP-2 in 5 mm rat femur gap model for 15 weeks. X-ray evidence of bridging was first found in the BMP group at 3 weeks. Bridging in all animals (N = 4) in the BMP group was found at 9 weeks. No x-ray evidence of bridging was found in the No BMP group (N = 3). pQCT analysis indicated that the bone mineral density of the callus in the BMP group has reached the level of native femur at 15 weeks after implantation, while the callus in the No BMP group has a bone mineral density at a lower level of 84% to the native femur. Histology analysis shows that a normal fatty bone marrow was restored and mineralized callus formed and bridged the segmental defect.

Animals↗

Ultrasound produced by a conventional therapeutic ultrasound unit accelerates fracture repair.

BACKGROUND AND PURPOSE: A recent novel application of ultrasound therapy is the treatment of bone fractures. The aim of this study was to investigate the effect on fracture repair of ultrasound produced by a conventional therapeutic ultrasound unit as used by physical therapists. SUBJECTS AND METHODS: Bilateral midshaft femur fractures were created in 30 adult male Long-Evans rats. Ultrasound therapy was commenced on the first day after fracture and introduced 5 days a week for 20 minutes a day. Each animal was treated unilaterally with active ultrasound and contralaterally with inactive ultrasound. Active ultrasound involved a 2-millisecond burst of 1.0-MHz sine waves repeating at 100 Hz. The spatially averaged, temporally averaged intensity was set at 0.1 W/cm2. Animals were killed at 25 and 40 days after fracture induction, and the fractures were assessed for bone mass and strength. RESULTS: There were no differences between fractures treated with active ultrasound and fractures treated with inactive ultrasound at 25 days. However, at 40 days, active ultrasound-treated fractures had 16.9% greater bone mineral content at the fracture site than inactive ultrasound-treated fractures. This change resulted in a 25.8% increase in bone size, as opposed to an increase in bone density, and contributed to active ultrasound-treated fractures having 81.3% greater mechanical strength than inactive ultrasound-treated fractures. DISCUSSION AND CONCLUSION: These data indicate that ultrasound produced by a conventional therapeutic ultrasound unit as traditionally used by physical therapists may be used to facilitate fracture repair. However, careful interpretation of this controlled laboratory study is warranted until its findings are confirmed by clinical trials.

Animals↗

Preliminary stabilization of the less invasive stabilization system.

We describe the use of a universal T-handle chuck to provide preliminary stabilization of the Less Invasive Stabilization System supracondylar femur implant and aiming device. This technique is helpful to maintain the position of the plate against the bone during intraoperative radiographs and initial screw insertion. Use of this simple technique may help avoid the problems that occur when the plate is positioned too far away from the lateral femoral cortex.

Bone Plates↗

Snowmobile trauma: 10 years' experience at Manitoba's tertiary trauma centre.

INTRODUCTION: According to the literature, the increased recreational use of the snowmobile has resulted in an increasing number of musculoskeletal injuries. We wished to examine whether previously described risk factors continue to be associated with snowmobile trauma and to identify previously unrecognized risks and specific patterns of injury. METHODS: We carried out a chart review of all snowmobile-related injuries over a 10-year period at the Health Sciences Centre in Winnipeg, the only level 1 trauma centre serving the Province of Manitoba, with particular attention to the risk factors of suboptimal lighting, excessive speed and alcohol consumption. RESULTS: We identified 480 injuries in 294 patients, and 81 (27.6%) of these patients died. Collisions accounted for 72% of the injury mechanisms. Of the injuries sustained, 31% occurred on roads. Excessive speed was a risk factor in 54% of patients, suboptimal lighting in 86% and a blood alcohol level greater than 0.08 in 70%. Musculoskeletal injuries accounted for 57% of those recorded. There were also brachial plexus injuries (3%) and knee dislocations (2%). To our knowledge, this is the largest study detailing injury associated with recreational use of snowmobiles in Canada. CONCLUSIONS: Because snowmobile trauma is caused principally by human errors, it is potentially preventable. Efforts aimed at prevention must focus on the driver, who controls the common risk factors. The danger of snowmobiling while intoxicated must be emphasized. Trail-side monitoring is likely to be ineffective, as the majority of accidents do not occur on designated snowmobile trails.

Adult↗