PubMed Health⌕ Search

Biomedical subjects

Rene Franzen

Publications and source records attributed to Rene Franzen.

2 recordsLinked to original sources

Temperature evolution on human teeth root surface after diode laser assisted endodontic treatment.

The thermal rise threshold of an 810-nm semi-conductor diode laser on the root surface when used in root canals in vitro for laser assisted root canal treatment is investigated in this study. A total of 50 human single-rooted extracted teeth were included. For this study, the canals were enlarged up to an apical size of ISO#50 file. Laser irradiation was performed with six different settings. Specimens were irradiated at 0.6-1 W output power at the distal end of the fiber and about 1-1.5 W output power in the continuous mode (CW) as two groups. In the third group, 0.6-1 W output power, 10 ms pulse length (PL) and 10 ms interval duration (ID) were selected. In three other groups 1-1.5 W output power were used with different PL and ID as following: PL 10 and ID 10 ms, PL 10 and ID 20 ms and PL 20 and ID 20 ms. The total irradiation time was from 5 to 20 s per canal with a 200 mum in diameter and 25 mm long tip. After laser treatment, the temperature changes at the outer root surface were registered by means of NiCr-Ni measuring sensors and a T 202 thermometer. The safe temperature threshold for applying this diode laser in root canal is considered as 7 degrees C increase. To avoid increasing the temperature changes at the outer root surface related to this threshold, following total irradiation times were found: 0.6-1 W output power (10 ms PL/10 ms ID): 20 s (s), 1-1.5 W output power (10 ms/10 ms and 20 ms/20 ms): 15 s, 0.6-1 W output power CW and 1-1.5 W output power (20 ms PL/10 ms ID): 10 s and 1-1.5 W output power CW: 5 s. In the first three groups, 5 s irradiation and 5 s rest period avoided a temperature increase above the threshold of 7 degrees C).

Body Temperature↗

Multireflection pumping concept for miniaturized diode-pumped solid-state lasers.

An innovative pump concept for diode-pumped, solid-state lasers is introduced as an example for an Er:YSGG laser, permitting its miniaturization. Embedded in a multireflective pump cavity, the laser crystal is simultaneously side and end pumped. Specially calculated and shaped deflecting optics distribute the coaxially input pumping light homogeneously over the lateral surface of the crystal, therefore reducing the size of the laser head, including the optical resonator, to a length of 27.5 mm and an outside diameter of 12.5 mm. The differential efficiency achieved is between 8.7% and 24%. The laser emits energy of 15.7 mJ at an absolute efficiency of 9.1% and a repetition rate of 4 Hz.

Equipment Design↗