PubMed Health⌕ Search

Biomedical subjects

Rene M Botnar

Publications and source records attributed to Rene M Botnar.

16 recordsLinked to original sources

MR coronary vessel wall imaging: comparison between radial and spiral k-space sampling.

PURPOSE: To compare radial and spiral k-space sampling in navigator-gated ECG-triggered three-dimensional (3D) coronary vessel wall imaging. MATERIALS AND METHODS: The right coronary artery (RCA) vessel walls of eight healthy subjects were imaged using a modified double-inversion prepulse in concert with radial and spiral data acquisition. For data analysis, two investigators blinded to the sequence parameters subjectively assessed image quality in terms of artifacts and vessel wall visualization. Objective measures of the signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and vessel wall definition were also determined. RESULTS: Radial k-space sampling demonstrated fewer artifacts and led to improved visualization of the coronary vessel wall compared to spiral imaging (P < 0.05). This finding was also reflected in a better vessel wall definition using radial data acquisition (P < 0.05). SNR and CNR were found to be higher when spiral k-space sampling was used (n.s.). CONCLUSION: Radial k-space sampling in concert with free-breathing navigator-gated cardiac-triggered MRI of the coronary vessel wall resulted in fewer motion artifacts and improved vessel wall definition compared to spiral k-space sampling. The proposed approach therefore appears to be preferable.

Adult↗

MRI of coronary vessel walls using radial k-space sampling and steady-state free precession imaging.

OBJECTIVE: The objective of our study was to investigate the impact of radial k-space sampling and steady-state free precession (SSFP) imaging on image quality in MRI of coronary vessel walls. SUBJECTS AND METHODS: Eleven subjects were examined on a 1.5-T MR system using three high-resolution navigator-gated and cardiac-triggered 3D black blood sequences (cartesian gradient-echo [GRE], radial GRE, and radial SSFP) with identical spatial resolution (0.9 x 0.9 x 2.4 mm3). The signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), vessel wall sharpness, and motion artifacts were analyzed. RESULTS: The mean SNR and CNR of the coronary vessel wall were improved using radial imaging and were best using radial k-space sampling combined with SSFP imaging. Vessel border definition was similar for all three sequences. Radial k-space sampling was found to be less sensitive to motion. Consistently good image quality was seen with the radial GRE sequence. CONCLUSION: Radial k-space sampling in MRI of coronary vessel walls resulted in fewer motion artifacts and improved SNR and CNR. The use of SSFP imaging, however, did not result in improved coronary vessel wall visualization.

Adult↗

Coronary magnetic resonance imaging: visualization of the vessel lumen and the vessel wall and molecular imaging of arteriothrombosis.

Coronary magnetic resonance (MR) imaging has dramatically emerged over the last decade. Technical improvements have enabled reliable visualization of the proximal and midportion of the coronary artery tree for exclusion of significant coronary artery disease. However, current technical developments focus also on direct visualization of the diseased coronary vessel wall and imaging of coronary plaque because plaques without stenoses are typically more vulnerable with higher risk of plaque rupture. Plaque rupture with subsequent thrombosis and vessel occlusion is the main cause of myocardial infarction. Very recently, the first success of molecular imaging in the coronary arteries has been demonstrated using a fibrin-specific contrast agent for selective visualization of coronary thrombosis. This demonstrates in general the high potential of molecular MR imaging in the field of coronary artery disease. In this review, we will address recent technical advances in coronary MR imaging, including visualization of the lumen and the vessel wall and molecular imaging of coronary arteriothrombosis. First results of these new approaches will be discussed.

Coronary Artery Disease↗

Molecular magnetic resonance imaging of atrial clots in a swine model.

BACKGROUND: The detection and differentiation of intracardiac masses is still challenging and may include neoplasms and thrombi. The aim of this study was the investigation of a targeted, fibrin-specific contrast agent (EP-2104R) for molecular targeted magnetic resonance imaging (MRI) of left atrial clots. METHODS AND RESULTS: Chronic human thrombi were surgically implanted in the left atrial appendage of 5 swine. Molecular MRI was performed with a navigator-gated, free-breathing, cardiac-triggered 3D inversion-recovery, black-blood, gradient-echo sequence before and after systemic administration of 4 micromol/kg EP-2104R. MR images were analyzed by 2 investigators, and the contrast-to-noise ratio was calculated. Location of clots was confirmed by autopsy, and the gadolinium concentration in the clots was assessed. Before contrast agent administration, thrombi were not visible on black-blood MR images. After contrast administration, all atrial clots (n=5) were selectively visualized as white spots with a high contrast-to-noise ratio (clot/blood, 29.7+/-8.0). The gadolinium concentration in the clots averaged 74+/-45 micromol/L. CONCLUSIONS: The fibrin-specific MR contrast agent EP-2104R allows for selective and high-contrast visualization of left atrial clots by means of molecular targeted MRI.

Animals↗

Molecular magnetic resonance imaging of pulmonary emboli with a fibrin-specific contrast agent.

RATIONALE AND OBJECTIVES: The detection of pulmonary embolism is still challenging due to the often nonspecific clinical findings. The aim of this study was to investigate the potential of molecular targeted magnetic resonance imaging (MRI) of pulmonary emboli using low-dose application of a fibrin-specific contrast agent (EP-2104R; Epix Pharmaceuticals, Cambridge, MA). METHODS: Fresh clots from human blood were engineered ex vivo and delivered in the lungs of 11 swine. Subsequently, a T1-weighted breath-hold three-dimensional gradient-echo sequence was performed before as well as 5 minutes, 1 hour, and 2 hours after systemic administration of 7.5 (n = 5) or 4 (n = 5) micromol/kg EP-2104R. One swine that did not receive any contrast agent served as a control. MR images were analyzed by two investigators and contrast-to-noise ratio between the thrombus and the surrounding tissue (blood pool and lung parenchyma) was assessed. Localization of thrombi was compared with 16-row multislice computed tomography. Finally, the animals were killed and thrombi were removed for assessment of gadolinium concentration. MAIN RESULTS: Before contrast media application, thrombi were not visible on MR images. At 1 and 2 hours after contrast media injection, pulmonary emboli were selectively visualized with high-signal intensity foci, independent of the dosage used. A high gadolinium concentration in thrombi was found after both dosages (83 +/- 41 microM for 4 micromol/kg and 130 +/- 57microM for 7.5 micromol/kg), resulting in a similar high contrast-to-noise ratio on MR images (between 11 and 13). CONCLUSION: Systemic low-dose application of EP-2104R allows for selective molecular MRI of fresh pulmonary thromboembolism in a swine model.

Animals↗

Molecular magnetic resonance imaging of coronary thrombosis and pulmonary emboli with a novel fibrin-targeted contrast agent.

BACKGROUND: The differential diagnosis of acute chest pain is challenging, especially in patients with normal ECG findings, and may include coronary thrombosis or pulmonary emboli. The aim of this study was to investigate the novel fibrin-specific contrast agent EP-2104R for molecular targeted MR imaging of coronary thrombosis and pulmonary emboli. METHODS AND RESULTS: Fresh clots were engineered ex vivo from human blood and delivered in the lungs and coronary arteries of 7 swine. Subsequent molecular MR imaging was performed with a navigator-gated free-breathing and cardiac-triggered 3D inversion-recovery black-blood gradient-echo sequence before and after systemic administration of 7.5 micromol/kg EP-2104R. Two swine served as the control group. MR images were analyzed by 2 investigators, and contrast-to-noise ratio and gadolinium concentration in the clots were assessed. Before contrast media application, no thrombi were visible. After contrast administration, all 32 pulmonary emboli, 3 emboli in the right heart, and 5 coronary thrombi were selectively visualized as white spots with a mean contrast-to-noise ratio of 32+/-19. The average gadolinium concentration from all 3 types of thrombi was 144+/-79 micromol/L. CONCLUSIONS: Molecular MR imaging with the fibrin-targeted contrast-agent EP-2104R allows selective visualization of acute coronary, cardiac, and pulmonary thrombi.

Angiography↗

Inherently self-calibrating non-Cartesian parallel imaging.

The use of self-calibrating techniques in parallel magnetic resonance imaging eliminates the need for coil sensitivity calibration scans and avoids potential mismatches between calibration scans and subsequent accelerated acquisitions (e.g., as a result of patient motion). Most examples of self-calibrating Cartesian parallel imaging techniques have required the use of modified k-space trajectories that are densely sampled at the center and more sparsely sampled in the periphery. However, spiral and radial trajectories offer inherent self-calibrating characteristics because of their densely sampled center. At no additional cost in acquisition time and with no modification in scanning protocols, in vivo coil sensitivity maps may be extracted from the densely sampled central region of k-space. This work demonstrates the feasibility of self-calibrated spiral and radial parallel imaging using a previously described iterative non-Cartesian sensitivity encoding algorithm.

Algorithms↗

Free-breathing 3D steady-state free precession coronary MR angiography with radial k-space sampling: comparison with cartesian k-space sampling and cartesian gradient-echo coronary MR angiography--pilot study.

The authors compared radial steady-state free precession (SSFP) coronary magnetic resonance (MR) angiography, cartesian k-space sampling SSFP coronary MR angiography, and gradient-echo coronary MR angiography in 16 healthy adults and four pilot study patients. Standard gradient-echo MR imaging with a T2 preparatory pulse and cartesian k-space sampling was the reference technique. Image quality was compared by using subjective motion artifact level and objective contrast-to-noise ratio and vessel sharpness. Radial SSFP, compared with cartesian SSFP and gradient-echo MR angiography, resulted in reduced motion artifacts and superior vessel sharpness. Cartesian SSFP resulted in increased motion artifacts (P <.05). Contrast-to-noise ratio with radial SSFP was lower than that with cartesian SSFP and similar to that with the reference technique. Radial SSFP coronary MR angiography appears preferable because of improved definition of vessel borders.

Adult↗

Comparison of aortic elasticity determined by cardiovascular magnetic resonance imaging in obese versus lean adults.

The vascular properties of large vessels in the obese have not been adequately studied. We used cardiovascular magnetic resonance imaging to quantify the cross-sectional area and elastic properties of the ascending thoracic and abdominal aorta in 21 clinically healthy obese young adult men and 25 men who were age-matched lean controls. Obese subjects had greater maximal cross-sectional area of the ascending thoracic aorta (984 +/- 252 vs 786 +/- 109 mm(2), p <0.01) and of the abdominal aorta (415 +/- 71 vs 374 +/- 51 mm(2), p <0.05). When indexed for height the differences persisted, but when indexed for body surface area, a significant difference between groups was found only for the maximal abdominal aortic cross-sectional area. The obese subjects also had decreased abdominal aortic elasticity, characterized by 24% lower compliance (0.0017 +/- 0.0004 vs 0.0021 +/- 0.0005 mm(2)/kPa/mm, p <0.01), 22% higher stiffness index beta (6.0 +/- 1.5 vs 4.9 +/- 0.7, p <0.005), and 41% greater pressure-strain elastic modulus (72 +/- 25 vs 51 +/- 9, p <0.005). At the ascending thoracic aorta, only the pressure-strain elastic modulus was different between obese and lean subjects (85 +/- 42 vs 65 +/- 26 kPa, respectively; p <0.05), corresponding to a 31% difference-but arterial compliance and stiffness index were not significantly different between groups. In clinically healthy young adult obese men, obesity is associated with increased cross-sectional aortic area and decreased aortic elasticity.

Adult↗

Coronary magnetic resonance angiography.

Coronary magnetic resonance angiography (CMRA) is a technique in clinical evolution. Current clinical applications include assessment for coronary anomalies, aneurysms, bypass graft patency, and, in experienced centers, the exclusion of proximal and multivessel coronary artery disease (CAD). As local expertise increases and more extensive multicenter data become available, additional applications will be established. CMRA promises to supplement and in some cases obviate the need for X-ray contrast angiography, and to expand our understanding of the pathophysiology of CAD.

Coronary Aneurysm↗

Fast interactive real-time magnetic resonance imaging of cardiac masses using spiral gradient echo and radial steady-state free precession sequences.

RATIONALE AND OBJECTIVES: Cardiac and respiratory controlled MR-imaging is the gold standard for imaging of cardiac masses. However, this technique may be limited in patients with dyspnoe or arrhythmia. The aim of this study was the evaluation of an interactive MR-approach for the detection and localization of cardiac masses. METHODS: Interactive real-time spiral gradient-echo (spiralGE) and radial steady-state-free-precession (radialSSFP) MR-imaging was performed during free-breathing and without cardiac triggering in 15 patients with 14 intracardiac or paracardiac masses. Standard cardiac triggered segmented k-space breath-hold steady-state-free-precession cine MR-imaging was used as the reference MR-imaging technique. Two groups of investigators blinded to clinical data were ask to rank image quality and to identify cardiac masses on real-time MR-images. RESULTS: Image quality was superior using radialSSFP when compared with spiralGE. Using radialSSFP all masses were correctly detected while 6 of 14 masses were missed on spiralGE. Mean real-time MR-imaging time was less than 3 minutes for both techniques. CONCLUSION: Interactive real-time radialSSFP MR-imaging allows for accurate and fast detection of cardiac masses without the need of cardiac or respiratory triggering.

Female↗

Quantitative assessment of left ventricular function with interactive real-time spiral and radial MR imaging.

An interactive real-time spiral gradient-echo and an interactive real-time radial steady-state free precession sequence were investigated for the quantitative assessment of left ventricular function. Data were acquired in 18 patients without electrocardiographic triggering and breath holding. With the interactive real-time spiral gradient-echo sequence, significant underestimation of endocardial and epicardial volumes was demonstrated; with the interactive real-time radial steady-state free precession sequence, excellent agreement was shown with standard cardiac-triggered segmented k-space breath-hold steady-state free precession MR imaging. Interactive real-time radial steady-state free precession imaging allows accurate quantitative assessment of left ventricular volumes.

Adult↗

Age and sex distribution of subclinical aortic atherosclerosis: a magnetic resonance imaging examination of the Framingham Heart Study.

Autopsy data demonstrate a correlation between subclinical aortic atherosclerosis and cardiovascular disease. Therefore, noninvasive cardiovascular magnetic resonance (CMR) of subclinical atherosclerosis may provide a novel measure of cardiovascular risk, but it has not been applied to an asymptomatic population-based cohort to establish age- and sex-specific normative data. Participants in the Framingham Heart Study offspring cohort who were free of clinically apparent coronary disease were randomly sampled from strata of sex, quartiles of age, and quintiles of Framingham Coronary Risk Score. Subjects (n=318, aged 60+/-9 years, range 36 to 78 years, 51% women) underwent ECG-gated T2-weighted black-blood thoracoabdominal aortic CMR scanning. CMR evidence of aortic atherosclerosis was noted in 38% of the women and 41% of the men. Plaque prevalence and all measures of plaque burden increased with age group and were greater in the abdomen than in the thorax for both sexes and across all age groups. In addition, the Framingham Coronary Risk Score was significantly correlated with all plaque prevalence and burden measures for women but only for men after age adjustment. These noninvasive CMR data extend the prior autopsy-based prevalence estimates of subclinical atherosclerosis and may help to lay the foundation for future studies of risk stratification and treatment of affected individuals.

Adult↗

Coronary magnetic resonance angiography for assessment of the stent lumen: a phantom study.

PURPOSE: To evaluate the feasibility of visualizing the stent lumen using coronary magnetic resonance angiography in vitro. MATERIAL AND METHODS: Nineteen different coronary stents were implanted in plastic tubes with an inner diameter of 3 mm. The tubes were positioned in a plastic container filled with gel and included in a closed flow circuit (constant flow 18 cm/sec). The magnetic resonance images were obtained with a dual inversion fast spin-echo sequence. For intraluminal stent imaging, subtraction images were calculated from scans with and without flow. Subsequently, intraluminal signal properties were objectively assessed and compared. RESULTS: As a function of the stent type, various degrees of in-stent signal attenuation were observed. Tantalum stents demonstrated minimal intraluminal signal attenuation. For nitinol stents, the stent lumen could be identified, but the intraluminal signal was markedly reduced. Steel stents resulted in the most pronounced intraluminal signal voids. CONCLUSIONS: With the present technique, radiofrequency penetration into the stents is strongly influenced by the stent material. Thesefindings may have important implicationsforfuture stent design and stent imaging strategies.

Blood Vessel Prosthesis Implantation↗

Real-time motion correction in navigator-gated free-breathing double-oblique submillimeter 3D right coronary artery magnetic resonance angiography.

RATIONALE AND OBJECTIVES: The purpose of this study was the investigation of the impact of real-time adaptive motion correction on image quality in navigator-gated, free-breathing, double-oblique three-dimensional (3D) submillimeter right coronary magnetic resonance angiography (MRA). MATERIALS AND METHODS: Free-breathing 3D right coronary MRA with real-time navigator technology was performed in 10 healthy adult subjects with an in-plane spatial resolution of 700 x 700 microm. Identical double-oblique coronary MR-angiograms were performed with navigator gating alone and combined navigator gating and real-time adaptive motion correction. Quantitative objective parameters of contrast-to-noise ratio (CNR) and vessel sharpness and subjective image quality scores were compared. RESULTS: Superior vessel sharpness, increased CNR, and superior image quality scores were found with combined navigator gating and real-time adaptive motion correction (vs. navigator gating alone; P < 0.01 for all comparisons). CONCLUSION: Real-time adaptive motion correction objectively and subjectively improves image quality in 3D navigator-gated free-breathing double-oblique submillimeter right coronary MRA.

Adult↗

Navigator-gated free-breathing three-dimensional balanced fast field echo (TrueFISP) coronary magnetic resonance angiography.

RATIONALE AND OBJECTIVES: Recent developments of MR imaging equipment enabled high-quality steady state-free-precession (Balanced FFE, True-FISP) MR-imaging with a substantial 'T2 like' contrast, resulting in a high signal intensity of the blood-pool without the application of exogenous contrast agents. It is hypothesized that Balanced-FFE may be valuable for contrast enhancement in 3D free-breathing coronary MRA. MATERIALS AND METHODS: Navigator-gated free-breathing cardiac triggered coronary MRA was performed in 10 healthy adult subjects and three patients with radiograph defined coronary artery disease using a segmented k-space 3D Balanced FFE imaging sequence. RESULTS: High contrast-to-noise ratio between the blood-pool and the myocardium (29 +/- 8) and long segment visualization of both coronary arteries could be obtained in about 5 minutes during free breathing using the present navigator-gated Balanced-FFE coronary MRA approach. First patient results demonstrated successful display of coronary artery stenoses. CONCLUSION: Balanced FFE offers a potential alternative for endogenous contrast enhancement in navigator-gated free-breathing 3D coronary MRA. The obtained results together with the relatively short scanning time warrant further studies in larger patient collectives.

Adult↗