PubMed Health⌕ Search

Biomedical subjects

Reza Razavi

Publications and source records attributed to Reza Razavi.

13 recordsLinked to original sources

Cardiac magnetic resonance imaging after stage I Norwood operation for hypoplastic left heart syndrome.

BACKGROUND: After the Norwood operation, a patient's suitability for proceeding to a bidirectional cavopulmonary connection (BCPC) is assessed by a combination of echocardiography and diagnostic cardiac catheterization. In this study, we describe the results of 37 patients who underwent cardiovascular magnetic resonance (MR) assessment before BCPC. METHODS AND RESULTS: Cardiovascular MR and echocardiography were performed in 37 infants with hypoplastic left heart syndrome before BCPC, and the findings were compared with surgical findings. MR assessment of ventricular function and valvar regurgitation were compared with echocardiography. MR exhibited high sensitivity and specificity for identification of neoaortic (sensitivity 86%, specificity 97%) and left pulmonary artery (sensitivity 100%, specificity 94%) obstruction. Echocardiography exhibited poor sensitivity for identification of vascular stenosis. The mean right ventricular ejection fraction calculated from the MR data was 50+/-10%. There was general agreement between MR and echocardiographic measures of ventricular function, although patients with good function on echocardiography demonstrated a wide range of ejection fractions. There was good agreement between MR and echocardiography for identification of valvar regurgitation. CONCLUSIONS: Cardiovascular MR can be used to define ventricular and valvar function and vascular anatomy in infants with hypoplastic left heart syndrome after the Norwood operation. We have shown how this information can be used to plan the BCPC and identify any revisions or additional valvar surgery.

Aorta↗

Dynamic three-dimensional undersampled data reconstruction employing temporal registration.

Dynamic 3D imaging is needed for many applications such as imaging of the heart, joints, and abdomen. For these, the contrast and resolution that magnetic resonance imaging (MRI) offers are desirable. Unfortunately, the long acquisition time of MRI limits its application. Several techniques have been proposed to shorten the scan time by undersampling the k-space. To recover the missing data they make assumptions about the object's motion, restricting it in space, spatial frequency, temporal frequency, or a combination of space and temporal frequency. These assumptions limit the applicability of each technique. In this work we propose a reconstruction technique based on a weaker complementary assumption that restricts the motion in time. The technique exploits the redundancy of information in the object domain by predicting time frames from frames where there is little motion. The proposed method is well suited for several applications, in particular for cardiac imaging, considering that the heart remains relatively still during an important fraction of the cardiac cycle, or joint imaging where the motion can easily be controlled. This paper presents the new technique and the results of applying it to knee and cardiac imaging. The results show that the new technique can effectively reconstruct dynamic images acquired with an undersampling factor of 5. The resulting images suffer from little temporal and spatial blurring, significantly better than a sliding window reconstruction. An important attraction of the technique is that it combines reconstruction and registration, thus providing not only the 3D images but also its motion quantification. The method can be adapted to non-Cartesian k-space trajectories and nonuniform undersampling patterns.

Algorithms↗

A system for real-time XMR guided cardiovascular intervention.

The hybrid magnetic resonance (MR)/X-ray suite (XMR) is a recently introduced imaging solution that provides new possibilities for guidance of cardiovascular catheterization procedures. We have previously described and validated a technique based on optical tracking to register MR and X-ray images obtained from the sliding table XMR configuration. The aim of our recent work was to extend our technique by providing an improved calibration stage, real-time guidance during cardiovascular catheterization procedures, and further off-line analysis for mapping cardiac electrical data to patient anatomy. Specially designed optical trackers and a dedicated calibration object have resulted in a single calibration step that can be efficiently checked and updated before each procedure. An X-ray distortion model has been implemented that allows for distortion correction for arbitrary c-arm orientations. During procedures, the guidance system provides a real-time combined MR/X-ray image display consisting of live X-ray images with registered recently acquired MR derived anatomy. It is also possible to reconstruct the location of catheters seen during X-ray imaging in the MR derived patient anatomy. We have applied our registration technique to 13 cardiovascular catheterization procedures. Our system has been used for the real-time guidance of ten radiofrequency ablations and one aortic stent implantation. We demonstrate the real-time guidance using two exemplar cases. In a further two cases we show how off-line analysis of registered image data, acquired during electrophysiology study procedures, has been used to map cardiac electrical measurements to patient anatomy for two different types of mapping catheters. The cardiologists that have used the guidance system suggest that real-time XMR guidance could have substantial value in difficult interventional and electrophysiological procedures, potentially reducing procedure time and delivered radiation dose. Also, the ability to map measured electrical data to patient specific anatomy provides improved visualization and a path to investigation of cardiac electromechanical models.

Cardiac Catheterization↗

MR coronary angiography and late-enhancement myocardial MR in children who underwent arterial switch surgery for transposition of great arteries.

PURPOSE: To prospectively evaluate the feasibility of magnetic resonance (MR) coronary artery imaging and to define myocardial damage with late-enhancement myocardial MR imaging in children who underwent arterial switch surgery for transposition of the great arteries. MATERIALS AND METHODS: The local research ethics committee approved this study, and the subjects and/or a parent or guardian gave informed consent. Sixteen asymptomatic subjects who had undergone arterial switch surgery for transposition of the great arteries were studied (mean age, 10.8 years +/- 1.3; 11 male subjects, five female subjects). MR coronary angiography, late-enhancement MR imaging, global ventricular function, and regional wall motion were assessed. Fifteen children were awake during imaging; one was imaged with the use of general anesthetic. RESULTS: In 23 (72%) of 32 coronary arteries imaged, diagnostic-quality images of the coronary ostium and proximal coronary artery course were acquired; this increased to 100% in subjects older than 11 years. No coronary ostial stenoses were seen. In all subjects, the proximal course of the coronary arteries was visualized. Two subendocardial viability defects were detected, which corresponded to known compromise of the artery that supplied that territory at the time of surgery. Global left and right ventricular function were preserved, with no regional wall abnormalities. CONCLUSION: Diagnostic-quality MR coronary angiography is feasible in subjects who have undergone arterial switch surgery for transposition of the great arteries, with no unexpected areas of myocardial infarction detected.

Adolescent↗

Accelerating cardiac cine 3D imaging using k-t BLAST.

By exploiting spatiotemporal correlations in cardiac acquisitions using k-t BLAST, gated cine 3D acquisitions of the heart were accelerated by a net factor of 4.3, making single breathhold acquisitions possible. Sparse sampling of k-t space along a sheared grid pattern was implemented into a cine 3D SSFP sequence. The acquisition of low-resolution training data, which was required to resolve aliasing in the k-t BLAST method, was either interleaved into the sampling process or obtained in a separate prescan to allow for shorter breathhold durations in patients with heart disease. Volumetric datasets covering the heart with 20 slices at a spatial resolution of 2 x 2 x 5 mm3 were recorded with 20 cardiac phases in a total breathhold duration of 25-27 sec, or 18 sec if partial Fourier sampling was additionally employed. The feasibility of the method was demonstrated on healthy volunteers and on patients. The comparison of endocardial area derived from single slices of the 3D dataset with values extracted from separate single-slice acquisitions showed no significant differences. By shortening the acquisition substantially, k-t BLAST may greatly facilitate volumetric imaging of the heart for evaluation of regional wall motion and the assessment of ventricular volume and ejection fraction.

Computer Simulation↗

Catheter tracking and visualization using 19F nuclear magnetic resonance.

This work presents an investigation into catheter visualization and localization using 19F nuclear magnetic resonance (NMR) in conjunction with proton imaging. For this purpose, the imaging capabilities of a standard system were extended to allow for 19F excitation and signal detection. Two modes of operation were implemented: 1) a real-time tracking mode that provides tip tracking and automatic slice position updates interleaved with real-time, interactive proton imaging; and 2) a non-real-time catheter length visualization mode in which the entire length of a catheter can be assessed. Initial phantom experiments were conducted with the use of an angiographic balloon catheter filled with the blood substitute perfluorooctylbromide (PFOB). Using limited bandwidth excitation centered at the resonances of the CF2 groups of PFOB, we found that sufficient signal could be received to facilitate tip tracking during catheter motion and length visualization for various catheter configurations. The present approach is considered a promising alternative to existing methods, which either are associated with safety concerns (if active markers are employed) or suffer from insufficient, direction-dependent contrast (if passive visualization is used). Furthermore, our approach enables visualization of the entire length of the catheter. The proposed method provides a safe technique that, unlike electrical or optical devices, does not require modification of commercially available catheters.

Catheterization↗

Cardiac anatomy revisited.

In tomorrow's world of clinical medicine, students will increasingly be confronted by anatomic displays reconstructed from tomographically derived images. These images all display the structure of the various organs in anatomical orientation, this being determined in time-honoured fashion by describing the individual in the 'anatomical position', standing upright and facing the observer. It follows from this approach that all adjectives used to describe the organs should be related to the three orthogonal planes of the body. Unfortunately, at present this convention is not followed for the heart, even though most students are taught that the so-called 'right chambers' are, in reality, in front of their 'left' counterparts. Rigorous analysis of the tomographic images already available, along with comparison with dissected hearts displayed in attitudinally correct orientation, calls into question this continuing tendency to describe the heart in terms of its own orthogonal axes, but with the organ positioned on its apex, so that the chambers can artefactually be visualized with the right atrium and right ventricle in right-sided position. Although adequate for describing functional aspects, such as 'right-to-left' shunting across intracardiac communications, this convention falls short when used to describe the position of the artery that supplies the diaphragmatic surface of the heart. Currently known as the 'posterior descending artery', in reality it is positioned inferiorly, and its blockage produces inferior myocardial infarction. In this review, we extend the concept of describing cardiac structure in attitudinally correct orientation, showing also how access to tomographic images clarifies many aspects of cardiac structure previously considered mysterious and arcane. We use images prepared using new techniques such as magnetic resonance imaging and computerized tomography, and compare them with dissection of the heart made in time-honoured fashion, along with cartoons to illustrate contentious topics. We argue that there is much to gain by describing the components of the heart as seen in the anatomical position, along with all other organs and structures in the body. We recognize, nonetheless, that such changes will take many years to be put into practice, if at all.

Aorta↗

Cardiac catheterisation guided by MRI in children and adults with congenital heart disease.

BACKGROUND: Fluoroscopically guided cardiac catheterisation is an essential tool for diagnosis and treatment of congenital heart disease. Drawbacks include poor soft tissue visualisation and exposure to radiation. We describe the first 16 cases of a novel method of cardiac catheterisation guided by MRI with radiographic support. METHODS: In our cardiac catheterisation laboratory, we combine magnetic resonance and radiographic imaging facilities. We used MRI to measure flow and morphology, and real-time MRI sequences to visualise balloon angiographic catheters. 12 patients underwent diagnostic cardiac catheterisation, two had interventional cardiac catheterisations, and for two patients, MRI was used to plan radiofrequency ablation for treatment of tachyarrhythmias. FINDINGS: In 14 patients, some or all of the cardiac catheterisation was guided by MRI. In two patients undergoing radiofrequency ablation, catheters were manipulated with use of fluoroscopic guidance and outcome was assessed with MRI. All patients received lower amounts of radiation than controls. There was some discrepancy between pulmonary vascular resistance calculated by flow derived from MRI and the traditional Fick method. We were able to superimpose fluoroscopic images of electro physiology electrode catheters on the three dimensional MRI of the cardiac anatomy. INTERPRETATION: We have shown that cardiac catheterisation guided by MRI is safe and practical in a clinical setting, allows better soft tissue visualisation, provides more pertinent physiological information, and results in lower radiation exposure than do fluoroscopically guided procedures. MRI guidance could become the method of choice for diagnostic cardiac catheterisation in patients with congenital heart disease, and an important tool in interventional cardiac catheterisation and radiofrequency ablation.

Adult↗

Myocardial delineation via registration in a polar coordinate system.

RATIONALE AND OBJECTIVES: Cardiovascular disease is the number one cause of premature death in the western world. Analysis of cardiac function provides clinically useful diagnostic and prognostic information; however, manual analysis of function via delineation is prohibitively time consuming. This article describes a technique for analysis of dynamic magnetic resonance images of the left ventricle using a non-rigid registration algorithm. A manually delineated contour of a single phase was propagated through the dynamic sequence. MATERIALS AND METHODS: Short-axis cine magnetic resonance images were resampled into polar coordinates before all the time frames were aligned using a non-rigid registration algorithm. The technique was tested on 10 patient data sets, a total of 1,052 images were analyzed. RESULTS: Results of this approach were investigated and compared with manual delineation at all phases in the cardiac cycle, and with registration performed in a Cartesian coordinate system. The results correlated very well with manually delineated contours. CONCLUSION: A novel approach to the registration and subsequent delineation of cardiac magnetic resonance images has been introduced. For the endocardium, the polar resampling technique correlated well with manual delineation, and better than for images registered without radial resampling in a Cartesian coordinate system. For the epicardium, the difference was not as apparent with both techniques correlating well.

Algorithms↗

Registration and tracking to integrate X-ray and MR images in an XMR facility.

We describe a registration and tracking technique to integrate cardiac X-ray images and cardiac magnetic resonance (MR) images acquired from a combined X-ray and MR interventional suite (XMR). Optical tracking is used to determine the transformation matrices relating MR image coordinates and X-ray image coordinates. Calibration of X-ray projection geometry and tracking of the X-ray C-arm and table enable three-dimensional (3-D) reconstruction of vessel centerlines and catheters from bi-plane X-ray views. We can, therefore, combine single X-ray projection images with registered projection MR images from a volume acquisition, and we can also display 3-D reconstructions of catheters within a 3-D or multi-slice MR volume. Registration errors were assessed using phantom experiments. Errors in the combined projection images (two-dimensional target registration error--TRE) were found to be 2.4 to 4.2 mm, and the errors in the integrated volume representation (3-D TRE) were found to be 4.6 to 5.1 mm. These errors are clinically acceptable for alignment of images of the great vessels and the chambers of the heart. Results are shown for two patients. The first involves overlay of a catheter used for invasive pressure measurements on an MR volume that provides anatomical context. The second involves overlay of invasive electrode catheters (including a basket catheter) on a tagged MR volume in order to relate electrophysiology to myocardial motion in a patient with an arrhythmia. Visual assessment of these results suggests the errors were of a similar magnitude to those obtained in the phantom measurements.

Adolescent↗

ICER reverses tumorigenesis of rat prostate tumor cells without affecting cell growth.

BACKGROUND: Inducible cAMP early repressor (ICER) is an important mediator of cAMP antiproliferative activity that acts as a putative tumor suppressor gene product. ICER is a transcriptional repressor that negatively regulates cAMP-mediated gene expression. Here, we report the effect of ectopically increasing the expression of ICER on in vitro and in vivo proliferation of the highly metastatic and androgen-insensitive AT6.3 rat prostate cells. METHODS: The proliferative potential of stable AT6.3 cell clones expressing ICER was studied by cell counts, thymidine incorporation, flow cytometry, colony formation in soft agar, and growth in immunodeficient nude mice. RESULTS: cAMP inhibits the growth of AT6.3 cells. ICER mRNA and protein levels were markedly induced by cAMP in AT6.3 cells. Forced expression of ICER in AT6.3 cells did not affect cell growth, thymidine incorporation, or the cell cycle. However, these ICER-bearing AT6.3 cells were rendered unable to grow in soft agar or to form tumors in nude mice. CONCLUSION: These results show that ICER specifically affects the tumorigenicity of prostate cancer cell without affecting their growth. Therefore, the manipulation of ICER expression could be used for the treatment of androgen-insensitive prostate tumors without causing undesirable toxicity to the cells.

8-Bromo Cyclic Adenosine Monophosphate↗

A study of the motion and deformation of the heart due to respiration.

This paper describes a quantitative assessment of respiratory motion of the heart and the construction of a model of respiratory motion. Three-dimensional magnetic resonance scans were acquired on eight normal volunteers and ten patients. The volunteers were imaged at multiple positions in the breathing cycle between full exhalation and full inhalation while holding their breath. The exhalation volume was segmented and used as a template to which the other volumes were registered using an intensity-based rigid registration algorithm followed by nonrigid registration. The patients were imaged at inhale and exhale only. The registration results were validated by visual assessment and consistency measurements indicating subvoxel registration accuracy. For all subjects, we assessed the nonrigid motion of the heart at the right coronary artery, right atrium, and left ventricle. We show that the rigid-body motion of the heart is primarily in the craniocaudal direction with smaller displacements in the right-left and anterior-posterior directions; this is in agreement with previous studies. Deformation was greatest for the free wall of the right atrium and the left ventricle; typical deformations were 3-4 mm with deformations of up to 7 mm observed in some subjects. Using the registration results, landmarks on the template surface were mapped to their correct positions through the breathing cycle. Principal component analysis produced a statistical model of the motion and deformation of the heart. We discuss how this model could be used to assist motion correction.

Adult↗