PubMed Health⌕ Search

Biomedical subjects

Ricardo J Cassella

Publications and source records attributed to Ricardo J Cassella.

7 recordsLinked to original sources

Multivariate optimization of a microwave-assisted leaching procedure using dilute acid solutions, for FAAS determination of Cu, Fe, Mn, and Zn in multivitamin/multimineral supplements.

This paper reports the development of a microwave-assisted procedure for leaching of copper, iron, manganese, and zinc from multivitamin/multimineral supplements by use of dilute acid before determination by flame atomic absorption spectrometry (FAAS). A Doehlert design was used to find optimum conditions for the procedure by use of response-surface methodology. Three variables (acid concentration in the leaching solution, irradiation time, and irradiation power) were used as factors in the optimization study for two acids, HCl and HNO(3). Final working conditions were established as a compromise between the optimum values for each analyte, taking into consideration the robustness of the procedure. The best leaching results were obtained with HNO(3) and the acid concentration, irradiation time, and irradiation power used were 0.70 mol L(-1), 15 min and 360 W, respectively. The accuracy of the optimized procedure was evaluated by comparison with a well-established closed-vessel microwave dissolution technique.

Acids↗

Distribution of copper in the vicinity of a deactivated mining site at Carajás in the Amazon region of Brazil.

In this work the re-fixation of mobilized copper (Cu) that was released from a deactivated pilot Cu ore dressing plant in the tropical rain forest at Southeastern Amazon (Carajás) was studied. Samples of top soils, decay leaf litter deposited on soils, roots and leaves of standing biomass were taken for the determination of Cu concentration in order to evaluate the distribution of it between different environmental compartments. In the sampling points near to the now extinct plant, total Cu concentrations in the soil reached an average value of 2140 microg g(-1) above the natural level of about 40 microg g(-1), being that bioavailable Cu estimated by DTPA method varied from 1.9 to 20.7% of this total. From the data was possible to calculate that the soil compartment is able to hold around 10 kg Cu/m(2) of ground. Roots of the standing biomass in that area hold around 17 g Cu/m(2), while the Cu content in leaves showed to be largely independent of the Cu level in the soil. Copper in the leaves was estimated as around 1g/m(2) of ground area. In turn, the decay leaf litter deposited on soil can hold about 1.6 g Cu/m(2). The terrestrial system surrounding the abandoned pilot plant demonstrated great buffer capacity to retain mobile Cu released by anthropogenic activities in the area.

Biomass↗

Determination of Cu, Fe, Mn and Zn by flame atomic absorption spectrometry in multivitamin/multimineral dosage forms or tablets after an acidic extraction.

This work presents the development of a methodology for the determination of Cu, Fe, Mn and Zn in samples of multivitamin/multimineral tablets, by flame atomic absorption spectrometry (FAAS), after extraction of the analytes with diluted hydrochloric acid solution. Several parameters that could influence the extraction process such as acid extraction solution concentration and nature, mixing mode (ultrasonic or magnetic stirring), extraction time and sample composition were evaluated. The obtained results showed that Fe, Mn and Zn were easily extracted with 1 mol/L HCl solution after 5 min of mixing with either ultrasonic or magnetic stirring for all studied samples. On the other hand, Cu extraction appeared to be more complex since it could only be extracted at the same conditions for silicate-free samples. For samples containing silicates the time of contact between solid sample and extraction solution presented remarkable influence, being necessary up to 12 h to achieve quantitative recovery with 1 mol/L HCl solution. The developed methodology was applied in the determination of Cu, Fe, Mn and Zn in seven commercially available multivitamin/multimineral tablets. The results obtained with the developed method were compared with those obtained after total digestion of samples using a closed-vessel microwave oven device.

Acids↗

On-line preconcentration and determination of Zn in natural water samples employing a styrene-divinylbenzene functionalized resin and flame atomic absorption spectrometry.

In this work, flame atomic absorption spectrometry (FAAS) was used as a detector for the determination of zinc in natural water samples with a flow-injection system coupled to solid-phase extraction (SPE). In order to promote the on-line preconcentration of zinc from samples a minicolumn packed with 35 mg of a styrene-divinylbenzene resin functionalized with (S)-2-[hydroxy-bis(4-vinylphenyl)methyl]pyrrolidine-1-carboxylic acid ethyl esther was utilized. The system operation was based on Zn(II) ion retention at pH 9.5 +/- 0.5 in such a minicolumn with analyte elution, at the back flush mode, with 1 mol L(-1) HCl directly to the FAAS nebulizer. The influence of the chemical (sample pH, buffer concentration, HCl eluent concentration and effect of the ionic strength) and flow (sample and eluent flow rates and preconcentration time) parameters that could affect the performance of the system were investigated as well as the possible interferents. At the optimum conditions, for 2 min of preconcentration time (9.9 ml of sample volume), the developed methodology presented a detection limit of 1.1 microg L(-1), a RSD of 3.5% at 10 microg L(-1) and an analytical throughput of 24 h(-1). Whereas, for 4 min of the preconcentration time (19.8 ml of sample volume) a detection limit of 0.98 microg L(-1), a RSD of 6.5% at 5 microg L(-1) and a sampling frequency of 13 h(-1) are reported.

Flame Ionization↗

Direct determination of arsenic and antimony in naphtha by electrothermal atomic absorption spectrometry with microemulsion sample introduction and iridium permanent modifier.

This paper reports the determination of arsenic and antimony in naphtha by employing electrothermal atomic absorption spectrometry (ETAAS) as the analytical technique. In order to promote the direct determination of the analytes in the very volatile naphtha, the formation of a microemulsion with different surfactants (Triton X-100 and Brij-35) and different chemical modification strategies were tested. The results indicated that Triton X-100 is the best emulsification agent for naphtha in both As and Sb determination when it is employed at a concentration of 1% w/v in the microemulsion. Under these conditions, the microemulsion was stabile for at least 2 h. By using Brij-35 it was possible to achieve good stability only in the first 15 min. Among all chemical modification approaches investigated (Ir permanent modifier, W-Ir permanent modifier, and Pd modifier), the Ir permanent modifier provided better sensitivity for both analytes and allowed a higher pyrolysis temperature, which decreased the background signals at lower levels. Under the best conditions established in this work, an RSD of 4.6% (20 microg L(-1)) and a detection limit of 2.7 microg L(-1) were observed for arsenic. For antimony, an RSD of 4.0% (20 microg L(-1)) and a detection limit of 2.5 microg L(-1) were obtained. The accuracy of the procedure was assessed by analyzing spiked samples of naphtha from different origins.

Journal Article↗

On-line solid phase extraction with polyurethane foam: trace level spectrophotometric determination of iron in natural waters and biological materials.

This paper reports the development of a simple and accurate on-line procedure for preconcentration and determination of dissolved iron in waters and biological materials using unloaded polyether-type polyurethane foam as solid extractor. In the developed flow injection system, the analyte was preconcentrated from acidic aqueous medium as iron-thiocyanate complex with post-elution with ascorbic acid solution and spectrophotometric measurement with 1,10-phenanthroline as colorimetric reagent. In order to improve the performance of the system several chemical and flow variables were investigated as well as the effect caused by the presence of possible interferents. The method was validated by the analysis of two certified reference materials. Application of the methodology was carried out by the determination of dissolved iron content in eight natural water samples with different characteristics. The results were compared with those obtained by electrothermal atomic absorption spectrometry (ETAAS) and no statistical difference was observed. The detection limit was 0.75 microgram l-1 and the RSD was 1.2% for 2 min preconcentration time. At this condition, a productivity of 20 samples h-1 was achieved. Increasing the preconcentration time up to 3 min, a detection limit of 0.45 microgram l-1, an RSD of 1.5% and an analytical throughput of 15 h-1 were verified.

Automation↗

Flow injection/atomic absorption spectrometric determination of zineb in commercial formulations of pesticide based on slurry sampling.

This paper reports on a new strategy for the slurry sampling determination of dithiocarbamate pesticide zineb [[ethylenebis(dithiocarbamato)]zinc] employing a FIA system with a flame atomic absorption spectrometry detector. In the flow system, an on-line alkaline hydrolysis of the pesticide is performed, allowing the release of Zn(II) ions to the solution, which are easily detected by a flame AAS technique. Several parameters that could affect the performance of the analytical methodology were studied, such as the concentration of NH3(aq) used in the hydrolysis step, the effect of the presence of Triton X-100 on the sensitivity and precision, and the FIA parameters (carrier flow rate and mixing coil volume). Under optimized conditions, aqueous slurries containing 2.5 to 25 microg ml(-1) zineb provided good linear calibration fits. From the obtained data, a detection limit (3sigma) of 1.0 microg ml(-1) zineb was found and a repeatability of 2.7% was obtained from 12 measurements of a slurry containing 2.5 microg m(-1) zineb. On the other hand, a precision (reproducibility) of 7.8% was achieved from three determinations of a sample containing 128 mg g(-1) of the pesticide. Also, the developed system provides a sampling frequency of 72 h(-1).

Flow Injection Analysis↗