PubMed Health⌕ Search

Biomedical subjects

Ricardo M Carvalho

Publications and source records attributed to Ricardo M Carvalho.

At least 19 recordsLinked to original sources

Effect of simulated pulpal pressure on dentin permeability and adhesion of self-etch adhesives.

OBJECTIVES: Dentin bonds made with one-bottle etch-and-rinse and self-etch adhesives are affected by the formation of interfacial blisters, porosities and deterioration. The first objective of this study was to evaluate the fluid flow through resin-dentin interfaces created by self-etching adhesives applied to deep dentin using a replica technique and by directly measuring dentin permeability (P). The second objective was to examine the effect of intrapulpal pressure on the microtensile bond strength of these adhesives. METHODS: A fluid-transport model was used to measure the fluid permeability (%P) through different adhesives. Impressions of bonded dentin were taken with a polyvinylsiloxane impression material to monitor fluid transudation from the surface of the adhesive. Positive replicas were fabricated for SEM examination. Two groups of resin-bonded specimens (pulpal pressure versus no pulpal pressure) were created for microtensile bond strength evaluation. Adhesive application was performed under 0 cm H(2)O. Pulpal pressure group was submitted to 20 cm H(2)O of pulpal pressure during build-up procedures. RESULTS: Clearfil Protect Bond exhibited the lowest permeability and fewest numbers of fluid droplets over the surface of the bonded dentin. G-Bond and Clearfil-S3 Bond were more permeable than Clearfil Protect Bond. One Up Bond F was the most permeable adhesive. A highly significant correlation was observed between the relative permeability of these adhesives (%P) and the number of fluid droplets on the adhesive surfaces. The application of pulpal pressure significantly reduced bond strength. SIGNIFICANCE: Resin-dentin bonds created by contemporary self-etch adhesives are susceptible to fluid permeation induced by pulpal pressure. HEMA-based adhesives showed the largest reductions in bond strengths after pulpal pressure application.

Acid Etching, Dental↗

Effect of hygroscopic expansion on the push-out resistance of glass ionomer-based cements used for the luting of glass fiber posts.

This study examined the contribution of hygroscopic expansion of glass-ionomer (GIC) and resin modified glass-ionomer (RMGIC) luting cements to the push-out resistance of fiber posts. Glass fiber posts were luted to post spaces using different cements. Experimental specimens were stored in water, while control specimens were desiccated and stored in mineral oil to eliminate water from intraradicular dentinal tubules and/or the external environment that could have contributed to hygroscopic expansion of the cements. Thin slice push-out tests revealed no difference in retention strengths of resin composite cements that were stored in water or oil. Conversely, GIC and RMGIC cements exhibited increased retention strengths after water sorption. As unfavorable cavity geometry is taxing to dentin bond integrity in root canals, a strategy that relies on increasing the frictional resistance to post dislodgement via delayed hygroscopic expansion of glass-ionomer based materials may be a more pragmatic approach to fiber post retention.

Acrylic Resins↗

Water sorption/solubility of dental adhesive resins.

OBJECTIVES: This study evaluated the water sorption, solubility and kinetics of water diffusion in commercial and experimental resins that are formulated to be used as dentin and enamel bonding agents. METHODS: Four commercial adhesives were selected along with their solvent-monomer combination: the bonding resins were of Adper Scotchbond Multi-Purpose (MP) and Clearfil SE Bond (SE) systems, and the "one-bottle" systems, Adper Single Bond (SB) and Excite (EX). Five experimental methacrylate-based resins of known hydrophilicities (R1, R2, R3, R4 and R5) were used as reference materials. Specimen disks were prepared by dispensing the uncured resin into a mould (5.8mm x 0.8mm). After desiccation, the cured specimens were weighed and then stored in distilled water for evaluation of the water diffusion kinetics over a 28-day period. RESULTS: Resin composition and hydrophilicity (ranked by their Hoy's solubility parameters) influenced water sorption, solubility and water diffusion in both commercial and experimental dental resins. The most hydrophilic experimental resin, R5, showed the highest water sorption, solubility and water diffusion coefficient. Among the commercial adhesives, the solvated systems, SB and EX, showed water sorption, solubility and water diffusion coefficients significantly greater than those observed for the non-solvated systems, MP and SE (p<0.05). In general, the extent and rate of water sorption increased with the hydrophilicity of the resin blends. SIGNIFICANCE: The extensive amount of water sorption in the current hydrophilic dental resins is a cause of concern. This may affect the mechanical stability of these resins and favor the rapid and catastrophic degradation of resin-dentin bonds.

Absorption↗

Activation of gelatinolytic/collagenolytic activity in dentin by self-etching adhesives.

Mild acids are known to activate dentin matrix metalloproteinase (MMPs). All self-etching dental adhesives are acidic (pH 1.5-2.7) and may activate dentin MMPs. The purpose of this study was to compare the ability of several all-in-one adhesives to activate gelatinolytic and collagenolytic activities in powdered mineralized dentin. Powdered dentin made from human teeth was mixed with all-in-one adhesives (Clearfil Tri-S Bond, G-Bond, Adper Prompt L-Pop) or a self-etching primer (Clearfil SE Bond primer) for varying times and then the reaction was stopped by extracting the adhesives using acetone. Fresh untreated mineralized dentin powder had a gelatinolytic activity of 3.31 +/- 0.39 relative fluorescent units (RFU) per mg dry weight (24 h) that increased, over storage time, to 87.5 RFU mg(-1) (24 h) after 6-8 wk. When fresh powder was treated with acidic Tri-S Bond, the gelatinolytic activity increased from 3.24 +/- 0.70 RFU mg(-1) to > 112.5 RFU mg(-1) (24 h) after 20 min and then remained unchanged. Monomers with lower pH values produced less activity. There was a significant, direct correlation between gelatinolytic activity and pH, with Tri-S giving the highest activity. Coating dentin powder with Tri-S resin prevented fluorescent substrates from gaining access to the enzyme, even though it activated the enzyme. In conclusion, self-etch adhesives may activate latent MMP and increase the activity to near-maximum levels and contribute to the degradation of resin-dentin bonds over time.

Adhesives↗

A new technique for assessing hybrid layer interfacial micromorphology and integrity: two-photon laser microscopy.

PURPOSE: This study describes a two-photon laser fluorescence microscopy technique developed to evaluate the interfacial micromorphology of the hybrid layer in bonded restorations. MATERIALS AND METHODS: Micropermeability of the hybrid layer was characterized by means of simultaneously contrasting a dye-containing adhesive with a differently colored dye placed into the pulp chamber and allowed to diffuse toward the different-colored hybrid layer. A fluorescent red dye (rhodamine B) was incorporated into a commercial dentin bonding agent. Class I preparations (margins in enamel) were made on extracted human third molars. The teeth were restored using conventional methods: bonding agent, composite, finishing, and polishing. An aqueous solution of a yellow/green dye (fluorescein) was then placed into the pulp chamber for 3 h, allowing time to diffuse toward the different-colored bonded interface. The teeth were then embedded, sectioned, and microscopically analyzed using two-photon laser microscopy at 40X magnification. RESULTS: Subsurface fluorescent imaging using this technique enabled interfacial micromorphology to be characterized at submicrometer resolution and provided high-contrast images. The quality of surrounding structures and potential presence of gaps were also precisely assessed. CONCLUSION: Two-photon laser microscopy provided high quality, high-resolution images of the bonded interface and surrounding areas, allowing accurate qualitative and quantitative analysis of the structure and integrity of the hybrid layer.

Bisphenol A-Glycidyl Methacrylate↗

Bond strength of resin-based restorations polymerized with different light-curing sources.

PURPOSE: To evaluate the influence of different light-curing units on microtensile bond strength of resin composite restorations. MATERIALS AND METHODS: Standardized Class I preparations (6.0 x 4.5 mm, 2.5 mm deep) were made in extracted human third molars after abrading the cusps. Resin was inserted in bulk using a 3M ESPE restorative system [Adper Single Bond (DBA)/ Filtek Z250 (RC)]. Both materials were polymerized using different light-curing units: QTH at 540 mW/cm(2) (XL 3000, 3M ESPE); LED at 750 mW/cm(2) (Elipar FreeLight2, 3M ESPE); PAC at 2130 mW/cm(2) (Arc Light II, Air Techniques). Nine different light combinations were developed to polymerize both DBA and RC: QTH/QTH; QTH/LED; QTH/PAC; LED/LED; LED/QTH; LED/PAC; PAC/PAC; PAC/QTH; PAC/LED. Restored teeth were stored in distilled water for 24 h at 37 degrees C and then sectioned, yielding stick-shaped specimens with a bonded area of approximately 0.9 mm(2). Specimens were assessed in a testing machine at a crosshead speed of 1 mm/min. The results were analyzed using two-way ANOVA and Tukey's test at a pre-set alpha = 0.05. RESULTS: The combinations PAC/QTH and QTH/QTH presented the highest bond strength values, and LED/QTH the lowest (p < 0.05). Significantly lower values were observed in combinations when the LED light was used to polymerize DBA compared to QTH and PAC lights, irrespective of the light source used to polymerize RC (p < 0.05). Same light combinations presented similar bond strength values. CONCLUSIONS: Different light sources influence restoration bond strength. Bond strength is more dependent on the light source used for DBA than for curing RC.

Bisphenol A-Glycidyl Methacrylate↗

Effect of resin hydrophilicity and temperature on water sorption of dental adhesive resins.

This study examined the effects of copolymer hydrophilicity and temperature on water sorption and solubility characteristics of five copolymer blends of increasing degree of hydrophilicity using gravimetric measurements. Six resin disks (15 mm in diameter x 1 mm in thickness) were prepared from each copolymer blend and were stored in deionised water at 23, 37 and 55 degrees C. Water sorption and solubility of the resin disks were measured before and after water immersion and desiccation. Multiple regression analysis of water sorption was performed on two independent variables, copolymer hydrophilicity and temperature. Maximum water sorption increased significantly with Hoy's total cohesive energy density (delta(t)), Hoy's solubility parameter for polar forces (delta(p)) and hydrogen bonding (delta(h)), but was not influenced by temperature. However, a significant positive relationship was observed between diffusion coefficients (obtained using Fick's law of diffusion) and temperature. The water absorption activation energy was 10 kJ/mol for the most hydrophilic copolymer blend R5 and 35-51 kJ/mol for copolymer blends R1-R4. The positive relationship between maximum water uptake and copolymer hydrophilicity suggests that water molecules diffuse through the polymer matrices by binding successively to the polar sites via hydrogen bonding. Such water sorption may determine the durability of resin-dentine bonds.

Adhesives↗

Bond angle effects on microtensile bonds: laboratory and FEA comparison.

OBJECTIVE: To test the hypothesis that there is a reduction in bond strength when a microtensile load is applied to adhesive junctions prepared at 10, 20 and 30 degrees to the usual perpendicular interface. To evaluate the effect of bond angle and adhesive layer thickness on stress levels within the adhesive joint utilizing FEA. METHODS: Twenty-four non-carious third molars were selected, occlusal enamel removed and polished perpendicular to the long axis of the tooth. The Clearfil SE Bond and Single Bond were applied on the dentin. A 4 mm resin restoration, Z 100, was built up. The teeth were sectioned at 10 degrees, 20 degrees and 30 degrees to the bonding interface (n = 3). The control (n = 3) group had all cuts parallel to the tooth longitudinal axis (0 degrees bond angle). The bond values were calculated in MPa and Two-Way ANOVA and Tukey test applied. FEA was performed (1 mm/side square specimens) to obtain the maximum principal stress (MPS) in the microtensile-model for each bond angle and for varying adhesive thickness from 20 microm to 200 microm for each group. RESULTS: The bond strength results diminish as the angle on the interface increased (P<0.05) for Clearfil SE Bond between 0 (control) and 30 degrees, and for Single Bond between 0 (control) and 10, 20, and 30 degrees. The hypothesis can be fully accepted for Single Bond and partially accepted for Clearfil SE Bond. For the FEA, there was a trend toward decreasing MPS as the bond angle increased, while the MPS for each angled group increased with adhesive layer thickness. SIGNIFICANCE: The MPS results for angled interfaces, exhibited the same trend as the lab values. FEA results indicated an MPS increase with increased adhesive thickness.

Bisphenol A-Glycidyl Methacrylate↗

Water content and apparent stiffness of non-caries versus caries-affected human dentin.

Caries-affected dentin contains less mineral and more water than surrounding normal dentin. Such dentin should be less stiff and should shrink more than normal dentin when dried. The purpose of this study was to test the relationships between the stiffness, shrinkage, and water content of caries-affected versus normal dentin. Extracted human carious third molars were stained with caries-detector dye and the occlusal surfaces ground down until only caries-affected dentin remained, surrounded by normal dentin. Dentin disks were prepared from these crowns placed in a aluminum well positioned under a modified thermal mechanical analyzer. Changes in specimen height and stiffness were measured following drying or static loading in both caries-affected and surrounding normal dentin. Core samples of these two types of dentin were used to gravimetrically measure water content. Two-way ANOVA and regression analysis was used to test the relationship between shrinkage versus water content, stiffness versus water content, and stiffness versus shrinkage. Caries-affected dentin was found to be less stiff and contained more water than normal dentin (p < 0.05). Regression analysis revealed highly significant inverse relationships between stiffness and water content, and stiffness and shrinkage (p < 0.0005).

Dental Caries↗

A challenge to the conventional wisdom that simultaneous etching and resin infiltration always occurs in self-etch adhesives.

This study provided morphological evidence that discrepancies between the depth of demineralisation and the depth of resin infiltration can occur in some mild self-etch adhesives. Sound dentine specimens derived from extracted human third molars were bonded with 5 one-step and 5 two-step self-etch adhesives. One millimeter thick slabs containing the resin-dentine interfaces were immersed in 50 wt% aqueous ammoniacal silver nitrate and processed for TEM examination. A zone of partially etched but uninfiltrated dentine was identified beneath the hybrid layers in the milder versions of both one-step and two-step self-etch adhesives. This zone was characterised by the occurrence of silver deposits along the interfibrillar spaces of mineralised collagen fibrils. The silver infiltrated interfibrillar spaces were clearly identified from the one-step self-etch adhesives Xeno III, iBond, Brush&Bond and the experimental adhesive, and were thinner and only occasionally observed in the two-step self-etch adhesives Clearfil SE Bond and Clearfil Protect Bond. The more aggressive one-step and two-step adhesives that exhibit more abrupt transitions from completely demineralised to mineralised dentin were devoid of these silver-infiltrated interfibrillar spaces beneath the hybrid layers. Incomplete resin infiltration observed in some self-etch adhesives may be caused by the reduced etching potential of the acidic monomers toward the base of hybrid layers, or the presence of acidic but non-polymerisable hydrolytic adhesive components, creating potential sites for the degradation of the bonded created by these self-etch adhesives.

Acid Etching, Dental↗

Effects of resin hydrophilicity on water sorption and changes in modulus of elasticity.

UNLABELLED: As acidic monomers of self-etching adhesives are incorporated into dental adhesives at high concentrations, the adhesive becomes more hydrophilic. Water sorption by polymers causes plasticization and lowers mechanical properties. The purpose of this study was to compare the water sorption and modulus of elasticity (E) of five experimental neat resins (EX) of increasing hydrophilicity, as ranked by their Hoy's solubility parameters and five commercial resins. METHODS: After measuring the initial modulus of all resin disks by biaxial flexure, half the specimens were stored in hexadecane and the rest were stored in water. Repeated measurements of stiffness were made for 3 days. Water sorption and solubility measurements were made in a parallel experiment. RESULTS: None of the specimens stored in oil showed any significant decrease in modulus. All resins stored in water exhibited a time-dependent decrease in modulus that was proportional to their degree of water sorption. Water sorption of EX was proportional to Hoy's solubility parameter for polar forces (delta(p)) with increasing polarity resulting in higher sorption. The least hydrophilic resin absorbed 0.55 wt% water and showed a 15% decrease in modulus after 3 days. The most hydrophilic experimental resin absorbed 12.8 wt% water and showed a 73% modulus decrease during the same period. The commercial resins absorbed between 5% and 12% water that was associated with a 19-42% reduction in modulus over 3 days.

Absorption↗

Solvent and water retention in dental adhesive blends after evaporation.

This study examined the extent of organic solvent and water retention in comonomer blends with different hydrophilicity (Hoy's solubility parameter for hydrogen bonding, delta(h)) after solvent evaporation, and the extent of tracer penetration in polymerised films prepared from these resins. For each comonomer blend, adhesive/solvent mixtures were prepared by addition of (1) 50 wt% acetone, (2) 50 wt% ethanol, (3) 30 wt% acetone and 20 wt% water and (4) 30 wt% ethanol and 20 wt% water. The mixtures were placed in glass wells and evaporated for 30-60s for acetone-based resins, and 60-120 s for ethanol-based resins. The weight of the comonomer mixtures was measured before and after solvent evaporation. Resin films were prepared for transmission electron microscopy (TEM) after immersion in ammonical silver nitrate. The percentages of solvent and water retained in the comonomer mixtures, and between the acetone and ethanol groups were measured gravimetrically and were statistically compared. In comonomer-organic solvent mixtures, the percentage of solvent retained in acetone and ethanol-based mixtures increased significantly with hydrophilicity of the comonomer blends (P < 0.05). In resin-organic solvent-water mixtures, significantly more solvent and water were retained in the ethanol-based mixtures (P < 0.0001), when compared to acetone-based mixtures after 60s of air-drying. TEM revealed residual water being trapped as droplets in resin films containing acetone and water. Water-filled channels were seen along the film periphery of all groups and throughout the entire resin films containing ethanol and water. The addition of water to comonomer-ethanol mixtures results in increased retention of both ethanol and water because both solvents can hydrogen bond to the monomers.

Absorption↗

Critical appraisal: adhesive-composite incompatibility, part I.

Apart from some questions related to the repairability of resin composite restorations, dentists have always assumed that methacrylate-based resins are compatible with each other. For example, there is no clinically relevant problem in using a microfilled composite to laminate a Class IV restoration made with a hybrid composite, even if they are not of the same brand or manufacturer. In the context of adhesive systems, we have always believed that resin composites, regardless of their type or composition, bond well to all types of bonding agents. However, unexpected debonding of self-cured, core buildup composites that had been bonded with single-bottle adhesive systems was reported about 5 years ago. Subsequent studies demonstrated that there were, indeed, compatibility problems between simplified adhesive systems and self- or dual-cured resin composites. Apparently, when such combinations are used, reduced bond strengths and subsequent failures at the resin-adhesive interface can occur because of adverse reactions between the acidic resin monomers, an integral part of the simplified adhesive systems, and the chemicals involved in the polymerization mechanism of the self- or dual-cured composites, particularly the basic tertiary amines. At least one research group has expanded the information on this issue by further investigating the mechanisms involved in this phenomenon. This group demonstrated that not only adverse chemical reactions but also the permeability of such simplified systems contribute to the compromised bonding. This issue has profound clinical implications in view of the wide use of self- and dual-cured composites as core buildup materials and in the bonding of indirect restorations and endodontic posts. Some of the most representative studies of this group are described in this Critical Appraisal. Part II will appear in the next issue of the Journal.

Journal Article↗

Adhesive-composite incompatibility, part II.

Apart from some questions related to the repairability of resin composite restorations, dentists have always assumed that methacrylate-based resins are compatible with each other. For example, there is no clinically relevant problem in using a microfilled composite to laminate a Class IV restoration made with a hybrid composite, even if they are not of the same brand or manufacturer. In the context of adhesive systems, we have always believed that resin composites, regardless of their type or composition, bond well to all types of bonding agents. However, unexpected debonding of self-cured, core buildup composites that had been bonded with single-bottle adhesive systems was reported about 5 years ago. Subsequent studies demonstrated that there were, indeed, compatibility problems between simplified adhesive systems and self- or dual-cured resin composites. Apparently, when such combinations are used, reduced bond strengths and subsequent failures at the resin-adhesive interface can occur because of adverse reactions between the acidic resin monomers, an integral part of the simplified adhesive systems, and the chemicals involved in the polymerization mechanism of the self- or dual-cured composites, particularly the basic tertiary amines.

Journal Article↗

Pit and fissure sealing. Bonding of bulk-cured, low-filled, light-curing resins to bacteria-contaminated uncut enamel in high c-factor cavities.

PURPOSE: To examine the ultrastructure of bonding to occlusal enamel fissures using phosphoric acid etching in combination with a pit and fissure sealant (Clinpro Sealant), a total-etch single-bottle adhesive (One-Step) followed by the fissure sealant, and two single-step self-etch adhesives (Adper Prompt and Xeno III) followed by the fissure sealant. METHODS: Sections of bonded enamel fissures retrieved from specimens bonded in vivo were polished, and rinsed with phosphoric acid to bring surfaces into relief. They were examined, first under non-dehydrated conditions with field emission-environmental SEM, to evaluate the marginal integrity of the bonds. The same specimens were then re-examined under dehydrated conditions with conventional SEM to capture more detailed ultrastructural features. Extent of resin penetration into etched enamel was further evaluated by TEM examination of sections taken from undemineralized unstained bonded specimens. These sections were further examined after HCl demineralization and staining. RESULTS: All occlusal fissure walls examined were lined with remnant aprismatic enamel. Full penetration of resins into the bottom of the fissures, and gap-free interfaces were not observed in any of the specimens, irrespective of whether total-etch or self-etch adhesives were used with the sealant. Phosphoric acid did not penetrate well into the fissures and although hybridization of the etched aprismatic enamel was observed with or without the use of the total-etch adhesive, etching was inconsistent and gaps were frequently observed. Entrapment of bacteria within the fissure walls was frequently seen. The more aggressive self-etch adhesive Adper Prompt created etching in aprismatic enamel that approached that of phosphoric acid etching. The moderately aggressive self-etch adhesive Xeno III produced 1 mm thick hybrid layers in the aprismatic enamel fissure wall.

Acid Etching, Dental↗

Durability of resin-dentin bonds related to water and oil storage.

PURPOSE: To evaluate the long-term effects of etching time, adhesive system and storage condition on resin bond strength to dentin. METHODS: Twenty-five extracted human third molars had a flat dentin surface exposed. Two total-etch adhesives, Single Bond (SB) and One-Step (OS), and one self-etching adhesive system, Clearfil Liner Bond 2V (CL), were used. The adhesives were bonded to dentin according to their respective manufacturer's instructions. Additional groups of SB and OS systems were created, in which the phosphoric acid etching time was doubled (30 seconds). After bonding, build-up crowns were constructed incrementally with Z250 resin composite and the teeth were stored for 24 hours in distilled water at 37 degrees C. The teeth were serially and vertically sectioned to obtain several bonded beams with approximately 0.8 mm2 of cross-sectional area. Beams were tested in microtensile (0.6 mm/minute) either immediately (control) or after storage for 6 months or 1 year in either distilled water or mineral oil. Data were analyzed by ANOVA and Tukey's multiple comparison tests. RESULTS: Significant reductions (P< 0.05) in bond strength were observed after both long-term storage periods in water for all the materials, regardless of the etching time for SB and OS. Bond strengths were either preserved or increased in specimens stored in oil.

Acrylic Resins↗

Microhardness of acid-treated and resin infiltrated human dentine.

OBJECTIVE: The aim is to determine if superficial or deep dentine microhardness (MH) is affected by different chemical dentine pre-treatments performed for resin bonding. METHODS: Dentine discs of superficial (SD) and deep dentine (DD) were obtained by transversally sectioning the crowns of human third molars. Knoop MH was measured after different treatments: (1) polished up to 4000 grit, (2) polished and etched (37% ortophosphoric acid for 15 s), (3) resin (Single Bond -SB-) infiltrated dentine after acid etching, (4) polished, etched and treated with 5% NaOCl for 2 min, (5) resin infiltrated (SB) after etching and NaOCl treatment. For resin infiltrated surfaces care was taken in order to remove the excess adhesive layer, and obtain infiltrated dentine, by measuring thickness of the sample before resin infiltration and polishing after resin infiltration until obtaining the initial thickness of the sample. Indentations (n=20) were performed on moist surfaces with a standard Knoop MH tester (20 g, 5 s). Data were expressed in Knoop Hardness Numbers (KHN) and analysed by ANOVA and multiple comparisons (P<0.05). RESULTS: Dentine KHN decreased on both SD and DD after acid etching. NaOCl treatment after acid etching did not affect MH on SD, but KHN of DD was lowered. Resin infiltration increased KHN but did not recover the initial MH values in both SD and DD. CONCLUSIONS: Treating dentine with either H3PO4 or NaOCl caused marked reduction of its surface hardness and subsequent resin infiltration was not capable to restore it.

Acid Etching, Dental↗

Effects of solvents on the early stage stiffening rate of demineralized dentin matrix.

OBJECTIVES: To monitor the stiffening rate of demineralized dentin matrix at the early stages after exposure to different neat solvents. METHODS: Dentin beams approximately 0.8x0.7x8.0 mm were obtained from human third molars. After covering their ends with resin composite, the middle exposed length of 4.0mm (gauge-length) was demineralized in 0.5 M EDTA (pH 7.0) for 7 days. The specimens were gripped by a testing machine, pre-loaded to 10 g and cyclically stressed in tension to 5% strain, for 30 repeated cycles (total 20 min) at 0.6 mm/min while immersed in water (control). Then, water was replaced by either 100% acetone, methanol, ethanol, propanol, HEMA or air and the specimens subjected to the same cyclic protocol. The maximum apparent modulus of elasticity (E(Max)) was calculated for every cycle, plotted as a function of time and subjected to regression analysis. Stiffening rate was calculated as changes in E (min). Regression analysis examined the relationship between E and time for each solvent. Data were analyzed by one-way ANOVA and Student-Newman-Keuls test at alpha=0.05. RESULTS: Regression analysis showed that E increased significantly with time in all water-free solvents (R2=0.8-0.99). Stiffening rate was higher for acetone (0.9 MPa/min) and ethanol (0.8 MPa/min), intermediate for air (0.7 MPa/min), methanol (0.6 MPa/min) and propanol (0.5 MPa/min), lower for HEMA (0.2 MPa/min) and practically none for water (0.07 MPa/min) with p<0.05. CONCLUSIONS: The solvent-induced stiffening rate of demineralized dentin matrix is both time and solvent-dependent. The ability of solvents to promptly stiffen the demineralized dentin matrix may be important in maintaining the resin-infiltrated matrix expanded during the solvent evaporation stage of resin bonding.

1-Propanol↗