PubMed Health⌕ Search

Biomedical subjects

Riccardo Iannaccone

Publications and source records attributed to Riccardo Iannaccone.

At least 19 recordsLinked to original sources

Polyp measurement and size categorisation by CT colonography: effect of observer experience in a multi-centre setting.

The extent measurement error on CT colonography influences polyp categorisation according to established management guidelines is studied using twenty-eight observers of varying experience to classify polyps seen at CT colonography as either 'medium' (maximal diameter 6-9 mm) or 'large' (maximal diameter 10 mm or larger). Comparison was then made with the reference diameter obtained in each patient via colonoscopy. The Bland-Altman method was used to assess agreement between observer measurements and colonoscopy, and differences in measurement and categorisation was assessed using Kruskal-Wallis and Chi-squared test statistics respectively. Observer measurements on average underestimated the diameter of polyps when compared to the reference value, by approximately 2-3 mm, irrespective of observer experience. Ninety-five percent limits of agreement were relatively wide for all observer groups, and had sufficient span to encompass different size categories for polyps. There were 167 polyp observations and 135 (81%) were correctly categorised. Of the 32 observations that were miscategorised, 5 (16%) were overestimations and 27 (84%) were underestimations (i.e. large polyps misclassified as medium). Caution should be exercised for polyps whose colonographic diameter is below but close to the 1-cm boundary threshold in order to avoid potential miscategorisation of advanced adenomas.

Chi-Square Distribution↗

CT colonography interpretation times: effect of reader experience, fatigue, and scan findings in a multi-centre setting.

Our purpose was to assess the effect of reader experience, fatigue, and scan findings on interpretation time for CT colonography. Nine radiologists (experienced in CT colonography); nine radiologists and ten technicians (both groups trained using 50 validated examinations) read 40 cases (50% abnormal) under controlled conditions. Individual interpretation times for each case were recorded, and differences between groups determined. Multi-level linear regression was used to investigate effect of scan category (normal or abnormal) and observer fatigue on interpretation times. Experienced radiologists (mean time 10.9 min, SD 5.2) reported significantly faster than less experienced radiologists and technicians; odds ratios of reporting times 1.4 (CI 1.1, 1.8) and 1.6 (1.3, 2.0), respectively (P<or=0.001). Experienced and less-experienced radiologists took longer to report abnormal cases; ratio 1.2 (CI 1.1,1.4, P<0.001) and 1.2 (1.0, 1.3, P=0.03), respectively. All groups took 70% as long to report the final five cases as they did with an initial five; ratio 0.7 (CI 0.6 to 0.8), P<0.001. For technicians only, accuracy increased with longer reporting times (P=0.04). Experienced radiologists report faster than do less-experienced observers and proportionally spend less time interpreting normal cases. Technicians who report more slowly are more accurate. All groups reported faster as the study period progressed.

Clinical Competence↗

Hepatic metastases: detection with multi-detector row CT, SPIO-enhanced MR imaging, and both techniques combined.

PURPOSE: To retrospectively compare the accuracy in detection of hepatic metastases among contrast material-enhanced multi-detector row computed tomography (CT) alone, superparamagnetic iron oxide (SPIO)-enhanced magnetic resonance (MR) imaging alone, and a combination of contrast-enhanced CT and SPIO-enhanced MR imaging. MATERIALS AND METHODS: The ethics committee did not require its approval or informed consent for this retrospective study, which was compliant with Declaration of Helsinki principles. Data in 38 patients (22 men, 16 women; mean age, 64.5 years; range, 35-78 years) suspected of having hepatic metastases who underwent both contrast-enhanced CT and SPIO-enhanced MR imaging were retrospectively analyzed. Twenty-one of the 38 patients had 61 metastases. Seventeen of the 61 metastases were confirmed histologically; the remaining 44 metastases were defined with imaging follow-up. At MR imaging, SPIO-enhanced heavily T1-weighted images, T2*-weighted gradient echo images, and T2-weighted fast spin-echo images were evaluated. Contrast-enhanced multi-detector row CT images obtained in the portal phase were evaluated. Four blinded observers independently reviewed CT images, MR images, and the combination of CT and MR images. Diagnostic accuracy was evaluated by using the alternative free-response receiver operating characteristic (AFROC) method. Sensitivities and positive predictive values were also analyzed with the Fisher protected least significant difference test and generalized estimating equations. RESULTS: The mean area under the AFROC curve for the combined approach (0.70) was significantly higher than that for SPIO-enhanced MR imaging alone (0.58, P < .05, Fisher protected least significant difference test), and there was no significant difference between each of them and that for contrast-enhanced CT alone (0.66). For all lesions, the mean sensitivity of combined imaging (0.59) was significantly higher than that of CT (0.48) or MR imaging (0.43) alone (P < .05, Fisher protected least significant difference test and generalized estimating equations). For all lesions, the mean positive predictive values were 0.82, 0.89, and 0.81, for combined MR and CT, CT alone, and MR alone, respectively. CONCLUSION: The addition of SPIO-enhanced MR imaging to contrast-enhanced multi-detector row CT (ie, combined analysis of SPIO-enhanced MR images and contrast-enhanced CT images) can improve sensitivity in the detection of hepatic metastases, although this improvement in sensitivity was not significant at AFROC analysis.

Adult↗

Hemodynamic characterization of focal hepatic lesions: role of ferucarbotran-enhanced dynamic MR imaging using T2-weighted multishot spin-echo echo-planar sequence.

PURPOSE: To investigate the role of ferucarbotran-enhanced dynamic MR imaging using multishot spin-echo echo-planar sequence in the evaluation of hemodynamics of focal hepatic lesions. MATERIALS AND METHODS: Sixty-three focal hepatic lesions (24 benign and 39 malignant) from 53 consecutive patients who underwent both ferucarbotran-enhanced MR imaging and dynamic computed tomography (CT) were included in this study. MR imaging was performed with a 1.5-T scanner with a phased-array coil. T2-weighted multishot spin-echo echo-planar sequences (TR/TE = 1714-2813/80 msec) were obtained during a single breathhold before and 15, 60, 120, 180, and 600 seconds after intravenous injection of ferucarbotran. The enhancement patterns of lesions were classified into three categories by a study coordinator on the basis of dynamic CT images as hypervascular, hypovascular, and hemangioma type. The study coordinator created mean contrast-to-noise ratio of lesions vs. time curves for each enhancement pattern for quantitative analyses. Moreover, three radiologists separately and blindly reviewed MR images, and then assigned three confidence scores for the three enhancement patterns to each lesion. Sensitivity, specificity, and receiver operating characteristic analyses were performed. RESULTS: Quantitative analyses showed characteristic enhancement curves for each enhancement pattern. Mean sensitivities/specificities were 0.816/0.882, 0.897/0.863, and 0.800/0.989 for hypervascular, hypovascular, and hemangioma types, respectively. Mean areas under the receiver operating characteristic curve were 0.886 for hypervascular type and 0.913 for hypovascular type. CONCLUSION: Ferucarbotran-enhanced dynamic MR imaging can be used to successfully characterize the hemodynamics of focal hepatic lesions.

Adult↗

Multinodular focal fatty infiltration of the liver: atypical imaging findings on delayed T1-weighted Gd-BOPTA-enhanced liver-specific MR images.

We report a case of pathologically confirmed multinodular focal fatty infiltration. MRI was performed after bolus injection of gadobenate dimeglumine (Gd-BOPTA, MultiHance; Bracco, Milan, Italy), a liver-specific paramagnetic, gadolinium (Gd)-based MR contrast agent that concomitantly enables the acquisition of a standard dynamic phase with timing strategies similar to those used for other extracellular fluid contrast agents, followed by a delayed T1-weighted liver-specific phase (the so-called hepatobiliary phase). In the present case, multiple rounded areas of fatty infiltration, although confidently diagnosed using chemical shift sequences due to a significant signal intensity reduction on out-of-phase images, were unexpectedly hypointense during the delayed liver-specific phase of Gd-BOPTA. Reduced Gd-BOPTA concentration during the liver-specific phase is generally correlated with liver malignancy. Since such lesions can be prospectively mistaken for metastatic disease, we performed a hepatic biopsy to establish a definitive diagnosis. Our empirical observations suggest that Gd-BOPTA uptake may be impaired in fatty infiltrated liver tissue. Because at present there is no report evaluating the kinetics of Gd-BOPTA in fatty liver, further studies are needed to specifically investigate this issue.

Adult↗

Assessment of two 3D MDCT colonography protocols for observation of colorectal polyps.

OBJECTIVE: The objective of our study was to assess the value of two-way interpretation (i.e., from rectum to cecum and vice versa) compared with one-way interpretation (i.e., from rectum to cecum only) in terms of polyp detection and interpretation time on MDCT colonography. MATERIALS AND METHODS: Fifty consecutive patients underwent both CT colonography and conventional colonoscopy. Three radiologists independently analyzed the CT colonographic examinations of each patient using a primary 3D method. All examinations were analyzed using two techniques: navigation from rectum to cecum only (one-way) and navigation from rectum to cecum and vice versa (two-way). Sensitivity and positive predictive value were calculated on both a per-polyp basis and a per-patient basis. Alternative free-response receiver operating characteristic (ROC) curve analysis was estimated, and image interpretation time was documented. RESULTS: One hundred fifty-five polyps were depicted in 45 patients by colonoscopy. The mean sensitivity of CT colonography for polyp detection with two-way (88.4%) was significantly superior to that with one-way (78.1%) (p < 0.01). The mean positive predictive value of each observer with one-way was 66.7%, whereas that with two-way was 65.8%. The mean area under the alternative free-response ROC curve (A(z) value) with two-way (0.827) was higher than that with one-way (0.816), but there was not a statistically significant difference. The average interpretation time of each observer with two-way (39 min) was statistically significantly longer than that with one-way (25 min) (p < 0.01). CONCLUSION: When using a primary 3D interpretation technique at CT colonography, complete 3D navigation from rectum to cecum and from cecum to rectum is mandatory to maximize polyp detection. The image interpretation time for two-way interpretation is statistically significantly longer than that with one-way interpretation.

Adult↗

Peliosis hepatis: spectrum of imaging findings.

OBJECTIVE: It is important to recognize the imaging characteristics of peliosis hepatis because peliotic lesions may mimic several different types of focal hepatic lesions CONCLUSION: We illustrate the spectrum of imaging findings of peliosis hepatis, including sonography, CT, MR, and angiography.

Adult↗

T staging of gastric cancer: role of multi-detector row CT.

PURPOSE: To evaluate retrospectively the accuracy of multi-detector row computed tomography (CT) in the assessment of serosal invasion in patients with gastric cancer. MATERIALS AND METHODS: The Ethics Committee does not require approval or informed consent for retrospective studies. Forty-one consecutive patients (24 men, 17 women; mean age, 68 years) with gastric cancer were included in this study. All patients were given 600 mL of tap water to drink and were positioned prone or supine on the scanning table. The detector row configuration included four detector rows, a section thickness of 1.25 mm, a pitch of 6, and a reconstruction interval of 0.63 mm. Transverse and multiplanar reconstruction images were simultaneously evaluated by two independent observers to assess the depth of tumor invasion in the gastric wall (ie, T stage). T staging at multi-detector row CT was compared with T staging at histologic evaluation (reference standard), which was performed by means of surgical or histologic examination of the resected specimen. We also calculated the sensitivity, specificity, and accuracy of multi-detector row CT for each observer in the assessment of serosal invasion. RESULTS: Analysis of interobserver agreement showed substantial or almost perfect agreement (nonweighted kappa value of 0.78 and weighted kappa value of 0.85). Correct assessment of gastric wall invasion was 80% and 85% for observers 1 and 2, respectively. The sensitivity, specificity, and accuracy of multi-detector row CT in the assessment of serosal invasion were 90%, 95%, and 93%, respectively, for observer 1 and 80%, 97%, and 93%, respectively, for observer 2. Overstaging occurred in six patients, and understaging occurred in five patients. All understaged tumors were scirrhous subtype gastric cancer. CONCLUSION: Multi-detector row CT scanning of patients with gastric cancer gave 93% accuracy in the assessment of serosal invasion in patients with gastric cancer.

Adult↗

Hepatocellular carcinoma: role of unenhanced and delayed phase multi-detector row helical CT in patients with cirrhosis.

PURPOSE: To determine, by using multi-detector row helical computed tomography (CT), the added value of obtaining unenhanced and delayed phase scans in addition to biphasic (hepatic arterial and portal venous phases) scans in the detection of hepatocellular carcinoma (HCC) in patients with cirrhosis. MATERIALS AND METHODS: Local ethical committee approval and patient consent were obtained. One hundred ninety-five patients (129 men, 66 women; mean age, 61 years; age range, 39-78 years) with 250 HCCs underwent multi-detector row helical CT of the liver. A quadruple-phase protocol that included unenhanced, hepatic arterial, portal venous, and delayed phases was performed. Analysis of images from hepatic arterial and portal venous phases combined, hepatic arterial and portal venous phases with the unenhanced phase, hepatic arterial and portal venous phases with the delayed phase, and all phases combined was performed separately by three independent radiologists. Relative sensitivity, positive predictive value, and area under the receiver operating characteristic curve (A(z)) were calculated for each reading session. RESULTS: Mean sensitivity and positive predictive values, respectively, for HCC detection were 88.8% (666 of 750 readings) and 97.8% (666 of 681 readings) for the combined hepatic arterial and portal venous phases, 89.2% (669 of 750 readings) and 97.8% (669 of 684 readings) for hepatic arterial and portal venous phases with the unenhanced phase, 92.8% (696 of 750 readings) and 97.3% (696 of 715 readings) for hepatic arterial and portal venous phases with the delayed phase, and 92.8% (696 of 750 readings) and 97.3% (696 of 715 readings) for all four phases combined. The reading sessions in which delayed phase images were available for interpretation showed significantly (P < .05) superior sensitivity and A(z) values. CONCLUSION: Unenhanced phase images are not effective for HCC detection. Because of the significant increase in HCC detection, a delayed phase can be a useful adjunct to biphasic CT in patients at risk for developing HCC.

Adult↗

Colorectal polyps: detection with low-dose multi-detector row helical CT colonography versus two sequential colonoscopies.

PURPOSE: To prospectively evaluate the diagnostic accuracy of low-radiation-dose computed tomographic (CT) colonography for detection of colorectal polyps by using two sequential colonoscopies, with the second colonoscopy as the reference standard. MATERIALS AND METHODS: The study was local ethics committee approved, and all patients gave written informed consent. Colonographic images were acquired by using a low-dose multi-detector row CT protocol (effective milliampere-second setting, 10 mAs). Three observers interpreted the CT colonographic data separately and independently by using a two-dimensional technique. Initial conventional colonoscopy was performed by an endoscopist unaware of the CT colonographic findings. Second colonoscopy performed within 2 weeks by a colonoscopist aware of both the CT colonographic and the initial colonoscopic findings served as the reference standard. The sensitivities of CT colonography and initial colonoscopy were calculated on a per-polyp and a per-patient basis. Specificities and positive and negative predictive values also were calculated on a per-patient basis. RESULTS: Eighty-eight patients underwent CT colonography and initial conventional colonoscopy on the same day. Per-polyp sensitivities were 62% and 83% for CT colonography and initial colonoscopy, respectively. Sensitivities for detection of polyps 6 mm in diameter or larger were 86% and 84% for CT colonography and initial colonoscopy, respectively. Initial colonoscopy failed to depict 16 polyps, six of which were correctly detected with CT colonography. For identification of patients with polyps 6 mm in diameter or larger, CT colonography and initial colonoscopy, respectively, had sensitivities of 84% and 90%, specificities of 82% and 100%, positive predictive values of 70% and 100%, and negative predictive values of 91% and 95%. CONCLUSION: Low-dose CT colonography compares favorably with colonoscopy for detection of colorectal polyps 6 mm in diameter or larger, with markedly decreased performance for detection of polyps 5 mm in diameter or smaller.

Aged↗

MR appearances of radiofrequency thermal ablation region: histopathologic correlation with dog liver models and an autopsy case.

RATIONALE AND OBJECTIVES: The purpose of this study was to evaluate the utility of magnetic resonance (MR) imaging for indicating the extent of true tissue necrosis of the liver after radiofrequency (RF) ablation in comparison with histopathologic findings in dog models and an autopsy case. MATERIALS AND METHODS: RF ablation of the liver parenchyma was performed on three dogs under general anesthesia. MR appearances of the RF-ablated regions on T1-weighted fast-low angle shot (FLASH; repetition time/echo time [TR/TE]/flip angle: 120/3.8/70),T2-weighted turbo spin echo (3000/80/echo train = 25) and contrast-enhanced T1-weighted images were compared with histopathologic findings. An autopsy case with hepatocellular carcinoma was also enrolled in this study. RESULTS: All ablated regions showed three zones on T1-weighted FLASH images: a central zone with low intensity, a broad hyperintense middle zone, and a surrounding hypointense band. The central and middle zones corresponded to the degrees of coagulation necrosis observed during histopathologic examination, whereas no viable cells were seen in these zones during the microscopic examination using nicotinamide adenine dinucleotide diaphorase stain. The surrounding hypointense band corresponded to sinusoidal congestion in the acute phase and to fibrotic change in the subacute phase. CONCLUSION: MR imaging using the FLASH sequence can accurately determine the extent of the necrotic area after RF ablation.

Aged↗

Computed tomographic colonography without cathartic preparation for the detection of colorectal polyps.

BACKGROUND AND AIMS: We prospectively compared the performance of low-dose multidetector computed tomographic colonography (CTC) without cathartic preparation with that of colonoscopy for the detection of colorectal polyps. METHODS: A total of 203 patients underwent low-dose CTC without cathartic preparation followed by colonoscopy. Before CTC, fecal tagging was achieved by adding diatrizoate meglumine and diatrizoate sodium to regular meals. No subtraction of tagged feces was performed. Colonoscopy was performed 3-7 days after CTC. Three readers interpreted the CTC examinations separately and independently using a primary 2-dimensional approach using multiplanar reconstructions and 3-dimensional images for further characterization. Colonoscopy with segmental unblinding was used as reference standard. The sensitivity of CTC was calculated both on a per-polyp and a per-patient basis. For the latter, specificity, positive predictive values, and negative predictive values were also calculated. RESULTS: CTC had an average sensitivity of 95.5% (95% confidence interval [CI], 92.1%-99%) for the identification of colorectal polyps > or =8 mm. With regard to per-patient analysis, CTC yielded an average sensitivity of 89.9% (95% CI, 86%-93.7%), an average specificity of 92.2% (95% CI, 89.5%-94.9%), an average positive predictive value of 88% (95% CI, 83.3%-91.5%), and an average negative predictive value of 93.5% (95% CI, 90.9%-96%). Interobserver agreement was high on a per-polyp basis (kappa statistic range, .61-.74) and high to excellent on a per-patient basis (kappa statistic range, .79-.91). CONCLUSIONS: Low-dose multidetector CTC without cathartic preparation compares favorably with colonoscopy for the detection of colorectal polyps.

Adult↗

Focal liver lesions in the cirrhotic patient: multislice spiral CT evaluation.

Imaging of the cirrhotic patient is a very difficult task due to the several morphologic and structural alterations that occur in the hepatic parenchyma. The presence of areas of fibrosis and regenerative nodules, often associated with haemodynamic alterations due to the portal hypertension, can make the identification of hepatocellular carcinoma very difficult or, in many cases, simulate the presence of tumour. Despite the use of state-of-the-art equipment and optimised study protocols, computed tomography (CT) has poor sensitivity for the detection of hepatocellular carcinoma. The present article illustrates the spiral CT findings that most often can be found in the evaluation of cirrhotic patients. In particular, the authors illustrate the CT patterns of regenerative nodules, dysplastic nodules, hepatocellular carcinomas and of all lesions that may mimic hepatocellular carcinoma.

Carcinoma, Hepatocellular↗

Hepatocellular carcinoma: detection with triple-phase multi-detector row helical CT in patients with chronic hepatitis.

PURPOSE: To evaluate whether the use of two arterial phase image acquisition series, when combined with portal venous phase imaging at multi-detector row helical computed tomography (CT), would be superior enough to use of a single arterial phase image acquisition series to warrant the increased radiation dose. MATERIALS AND METHODS: Multi-detector row CT was performed in 77 patients with 140 foci of hepatocellular carcinoma (HCC). A triple-phase protocol that included an early arterial phase, a late arterial phase, and a portal venous phase was performed. Images were analyzed separately by three radiologists to document the presence and number of HCC nodules. Separate reading sessions were performed for images from the early arterial phase, images from the late arterial phase, images from both arterial phases combined, and images from all three phases. Sensitivity and positive predictive values were calculated for each reading session. RESULTS: The average sensitivity and positive predictive values, respectively, for the detection of HCC were 48.5% and 96.4% for early arterial phase images, 87.1% and 94.0% for late arterial phase images, 87.1% and 94.0% for images from both arterial phases, and 88.5% and 93.4% for images from all three phases. Analysis of images from both arterial phases together yielded no improvement in either sensitivity or positive predictive value compared with analysis of late arterial phase images alone. Analysis of the combination of late arterial and portal venous phase images resulted in the highest sensitivity value. CONCLUSION: The acquisition of images during two arterial contrast phases does not provide additional benefit over timed conventional biphasic CT technique.

Aged↗

Detection of colorectal lesions: lower-dose multi-detector row helical CT colonography compared with conventional colonoscopy.

PURPOSE: To compare the performance of lower-dose multi-detector row helical computed tomographic (CT) colonography with that of conventional colonoscopy in the detection of colorectal lesions. MATERIALS AND METHODS: One hundred fifty-eight patients underwent multi-detector row helical CT colonography (beam collimation, 4 x 2.5 mm; table feed, 17.5 mm/sec; voltage, 140 kV; and effective dose, 10 mAs) followed by conventional colonoscopy. Conventional colonoscopy served as the reference standard. Two radiologists interpreted CT colonographic images to assess the presence of polyps or carcinomas. Sensitivity was calculated on both a per-polyp and a per-patient basis. In the latter, specificity and positive and negative predictive values were also calculated. Weighted CT dose index was calculated on the basis of measurements obtained in a standard body phantom. Effective dose was estimated by using commercially available software. RESULTS: CT colonography correctly depicted all 22 carcinomas (sensitivity, 100%) and 52 of 74 polyps (sensitivity, 70.3%). Sensitivity for detection was 100% in all 13 polyps 10 mm or larger in diameter, 83.3% in 20 of 24 polyps 6-9 mm, and 51.3% in 19 of 37 lesions 5 mm or smaller. With regard to the per-patient analysis, CT colonography had a sensitivity of 96.0%, a specificity of 96.6%, a positive predictive value of 94.1%, and a negative predictive value of 97.7%. The total weighted CT dose index for combined prone and supine acquisitions was 2.74 mGy. The simulated effective doses for complete CT colonography were 1.8 mSv in men and 2.4 mSv in women. CONCLUSION: Lower-dose multi-detector row helical CT colonography ensures substantial dose reduction while maintaining excellent sensitivity for detection of colorectal carcinomas and polyps larger than 6 mm in diameter.

Aged↗

Contrast-enhanced computed tomographic colonography in the follow-up of colorectal cancer patients: a feasibility study.

The aim of our study was to assess whether contrast-enhanced CT colonography is a feasible alternative to both conventional colonoscopy and liver ultrasonography in the follow-up program of colorectal cancer patients. Thirty-five patients, surgically treated for colorectal cancer, underwent a follow-up program that included physical examination, carcinoembryonic antigen serum assay, conventional colonoscopy, liver ultrasonography, and chest X-ray. For these patients, we added a yearly contrast-enhanced CT colonography. All CT examinations were performed with a high-resolution protocol using a multidetector spiral CT scanner (Siemens, Erlangen, Germany) prior to and after the administration of 130 ml of i.v. contrast material. Images were directly analyzed on a dedicated workstation by two radiologists to determine colonic evaluation, visualization of colonic anastomosis, presence of polyps, and extra-colonic findings. Colonic evaluation was judged as optimal in 91.7% of all colonic segments. All mechanical surgical anastomoses were visualized with CT colonography. There was no evidence of anastomotic recurrence. Seven polyps were detected in five different patients with CT colonography, with two false-positive and no false-negative examinations. Three liver metastases and two basal pulmonary nodules were also identified. Contrast-enhanced CT colonography is a feasible alternative to both conventional colonoscopy and liver ultrasonography in the follow-up of patients operated on for colorectal cancer.

Adenocarcinoma↗