PubMed Health⌕ Search

Biomedical subjects

Richard B Thompson

Publications and source records attributed to Richard B Thompson.

At least 19 recordsLinked to original sources

Measuring picomolar intracellular exchangeable zinc in PC-12 cells using a ratiometric fluorescence biosensor.

Zinc plays both physiological and pathological roles in biology, making it of increasing interest. To date, intracellular free zinc has been measured in cell types supplemented with or enriched in zinc, such as hippocampal neurons. Here we quantitatively image intracellular exchangeable zinc in an ordinary resting cell culture line (PC-12), using an excitation ratiometric fluorescent biosensor based on carbonic anhydrase (CA). Human CA II has a K d of 4 pM for zinc and suffers no interference from millimolar calcium or magnesium ions. The CA-based biosensor was readily introduced into the cell by a novel approach: fusing a transactivator of transcription (TAT)-derived cell penetrating peptide to the CA molecule and adding it to the cells. Our results indicate that the resting concentration is approximately 5-10 pM in cytoplasm and nucleus. Interestingly, the tetrakis(2-pyridylmethyl)ethylenediamine (TPEN)-Zn complex and TPEN are both apoptogenic for this cell line.

Animals↗

Synaptic release of zinc from brain slices: factors governing release, imaging, and accurate calculation of concentration.

Cerebrocortical neurons that store and release zinc synaptically are widely recognized as critical in maintenance of cortical excitability and in certain forms of brain injury and disease. Through the last 20 years, this synaptic release has been observed directly or indirectly and reported in more than a score of publications from over a dozen laboratories in eight countries. However, the concentration of zinc released synaptically has not been established with final certainty. In the present work we have considered six aspects of the methods for studying release that can affect the magnitude of zinc release, the imaging of the release, and the calculated concentration of released zinc. We present original data on four of the issues and review published data on two others. We show that common errors can cause up to a 3000-fold underestimation of the concentration of released zinc. The results should help bring consistency to the study of synaptic release of zinc.

Animals↗

Partial field-of-view spiral phase-contrast imaging using complex difference processing.

Rapid flow imaging was achieved with a partial field of view (pFOV) spiral motion-encoded technique. The FOV and the acquisition time were reduced by a factor of 2 by undersampling k-space. The pFOV spiral k-space trajectory aliased signals from outside a circular ring whose radius was inversely proportional to the distance between adjacent spirals in k-space. In this study the FOV was adjusted so that all of the moving spins were located inside the inner half circle of the full FOV. Complex subtraction of two differentially flow-encoded images was used to remove the spurious phase sources and provide an accurate measurement of flow. The complex subtraction process also serves to eliminate aliasing artifacts that are generated by static tissue from outside the reduced FOV. Experiments in a flow phantom and volunteers showed that the flow estimates obtained by pFOV spiral motion encoding are in good agreement with the estimates reconstructed using complex difference processing.

Adult↗

Cardiorespiratory-resolved magnetic resonance imaging: measuring respiratory modulation of cardiac function.

A technique for cardiac- and respiratory-resolved MRI is described. A retrospectively gated-segmented acquisition scheme similar to that used in conventional cine cardiac imaging was used to collect image data that spanned both the cardiac and respiratory cycles. Raw k-space data were regridded in a cardiorespiratory phase space to allow image reconstruction at target cardiac and respiratory phases. The approach can be applied with various k-space trajectories and pulse sequences, and was implemented in this study with both a Cartesian steady-state free precession (SSFP) sequence and a radial phase-contrast (PC) pulse sequence. Free-breathing short-axis SSFP images of the heart were reconstructed at multiple respiratory and cardiac phases to illustrate separation of cardiac and respiratory motion without artifacts. A respiratory-resolved radial PC experiment was used to quantify the volumetric flow rates in the inferior vena cava (IVC), pulmonary artery (PA), and aorta (Ao) in five free-breathing normal volunteers and a positive-pressure ventilated dog. Total flow (ml/min) in each vessel was quantified as a function of respiratory phase (peak/minimum output = 1.85 +/- 0.29 (IVC), 1.36 +/- 0.15 (PA), 1.24 +/- 0.09 (Ao)). Peak flow occurred during inspiration for the IVC and PA, and during expiration for the Ao, and there was a complete pattern reversal for the positive-pressure ventilated dog.

Adult↗

Real-time magnetic resonance imaging-guided stenting of aortic coarctation with commercially available catheter devices in Swine.

BACKGROUND: Real-time MR imaging (rtMRI) is now technically capable of guiding catheter-based cardiovascular interventions. Compared with x-ray, rtMRI offers superior tissue imaging in any orientation without ionizing radiation. Translation to clinical trials has awaited the availability of clinical-grade catheter devices that are both MRI visible and safe. We report a preclinical safety and feasibility study of rtMRI-guided stenting in a porcine model of aortic coarctation using only commercially available catheter devices. METHOD AND RESULTS: Coarctation stenting was performed wholly under rtMRI guidance in 13 swine. rtMRI permitted procedure planning, device tracking, and accurate stent deployment. "Active" guidewires, incorporating MRI antennas, improved device visualization compared with unmodified "passive" nitinol guidewires and shortened procedure time (26+/-11 versus 106+/-42 minutes; P=0.008). Follow-up catheterization and necropsy showed accurate stent deployment, durable gradient reduction, and appropriate neointimal formation. MRI immediately identified aortic rupture when oversized devices were tested. CONCLUSIONS: This experience demonstrates preclinical safety and feasibility of rtMRI-guided aortic coarctation stenting using commercially available catheter devices. Patients may benefit from rtMRI in the future because of combined device and tissue imaging, freedom from ionizing radiation, and the ability to identify serious complications promptly.

Animals↗

DsRed as a highly sensitive, selective, and reversible fluorescence-based biosensor for both Cu(+) and Cu(2+) ions.

The wild type form of Red fluorescent protein (DsRed), an intrinsically fluorescent protein found in tropical corals, is found to be highly selective, reversible and sensitive for both Cu(+) and Cu(2+), with a nanomolar detection limit. The selectivity towards these ions is retained even in the presence of other heavy metal ions. The K(d) values for monovalent and divalent copper, based on single binding isotherms, are 450 and 540 nM, respectively. The wild type DsRed sensitivity to Cu(2+) (below 1 ppb) is seven orders of magnitude better than that of the related wild type Green Fluorescent protein (GFP), and it is even 40 times more sensitive than engineered mutants of GFP. Potential binding sites have been proposed, based on amino acid sequences for copper binding and the distance from the chromophore, with the aid of computer modeling.

Biosensing Techniques↗

Real-time magnetic resonance-guided endovascular repair of experimental abdominal aortic aneurysm in swine.

OBJECTIVES: This study tested the hypotheses that endografts can be visualized and navigated in vivo solely under real-time magnetic resonance imaging (rtMRI) guidance to repair experimental abdominal aortic aneurysms (AAA) in swine, and that MRI can provide immediate assessment of endograft apposition and aneurysm exclusion. BACKGROUND: Endovascular repair for AAA is limited by endoleak caused by inflow or outflow malapposition. The ability of rtMRI to image soft tissue and flow may improve on X-ray guidance of this procedure. METHODS: Infrarenal AAA was created in swine by balloon overstretch. We used one passive commercial endograft, imaged based on metal-induced MRI artifacts, and several types of homemade active endografts, incorporating MRI receiver coils (antennae). Custom interactive rtMRI features included color coding the catheter-antenna signals individually, simultaneous multislice imaging, and real-time three-dimensional rendering. RESULTS: Eleven repairs were performed solely using rtMRI, simultaneously depicting the device and soft-tissue pathology during endograft deployment. Active devices proved most useful. Intraprocedural MRI provided anatomic confirmation of stent strut apposition and functional corroboration of aneurysm exclusion and restoration of laminar flow in successful cases. In two cases, there was clear evidence of contrast accumulation in the aneurysm sac, denoting endoleak. CONCLUSIONS: Endovascular AAA repair is feasible under rtMRI guidance. Active endografts facilitate device visualization and complement the soft tissue contrast afforded by MRI for precise positioning and deployment. Magnetic resonance imaging also permits immediate post-procedural anatomic and functional evaluation of successful aneurysm exclusion.

Angioplasty↗

Invasive human magnetic resonance imaging: feasibility during revascularization in a combined XMR suite.

We tested the feasibility and safety of invasive magnetic resonance imaging (MRI) during peripheral angioplasty. Real-time MRI can image soft tissue and may potentially guide therapeutic procedures without ionizing radiation or nephrotoxic contrast. MRI-guided diagnostic catheterization has been described recently, but safe and conspicuous catheter devices are not widely available. An active guidewire, which serves as an MRI receiver antenna, might be useful to guide catheterization or even to image atheroma. We describe a combined interventional suite offering both X-ray fluoroscopy and real-time MRI. We used a 0.030'' active guidewire receiver coil for invasive MRI after X-ray lesion traversal in patients undergoing percutaneous iliofemoral artery revascularization. Intravascular MRI was compared with noninvasive MRI, X-ray angiography, and intravascular ultrasound (IVUS). Seven eligible patients consented to participate, but three were excluded because of lengthy revascularization procedures. Four remaining patients safely underwent combined X-ray fluoroscopy and real-time magnetic resonance imaging (XMR) transport, continuous monitoring, and all imaging modalities. There was no device dislodgment, contamination or evidence of heating. The intravascular MRI coil was well visualized except at the tip, but did not provide superior mural imaging compared with IVUS. Therefore, because an adequate safety and workflow experience was obtained, enrollment was terminated after only four subjects. Invasive MRI is feasible and apparently safe during peripheral angioplasty. Patients can safely be transported and monitored in an XMR interventional suite. An active quarter-wavelength guidewire coil does not provide superior imaging compared with IVUS, but provides satisfactory guidewire visualization. These tools may prove useful for advanced therapeutic procedures in the future.

Aged↗

Catheter-mediated subselective intracoronary gene delivery to the rabbit heart: introduction of a novel method.

BACKGROUND: Recent studies suggest that gene therapy using replication-deficient adenoviruses will benefit treatment of cardiovascular diseases including heart failure. A persistent hurdle is the effective and reproducible delivery of a transgene to the myocardium with minimal iatrogenic morbidity. In this study, we sought to design a relatively non-invasive percutaneous gene delivery system that would maximize cardiac transgene expression and minimize mortality after intracoronary adenovirus injection. METHODS: Adult rabbits received a left circumflex coronary artery (LCx) infusion of 5x10(11) total viral particles of an adenovirus containing the marker transgene beta-galactosidase (Adeno-betaGal) via either a continuous infusion method utilizing an oxygenated, normothermic, physiologic pH Krebs solution driven by a Langendorff apparatus (n=12) or a timed bolus and set concentration at a constant infusion rate to the LCx (n=12). Six rabbits underwent global transgene delivery via an invasive method involving intraventricular delivery and aortic root cross-clamping. The efficacy of transgene expression via these three distinct delivery methods was determined in the left ventricle at 5 days by histological staining and colorimetric quantification assay. RESULTS: While the open-chest, aortic cross-clamping method provides the highest level of gene expression throughout the heart, the morbidity of this procedure is clinically prohibitive. Percutaneous LCx delivery of Adeno-betaGal using the Langendorff apparatus was associated with the lowest morbidity and mortality while still supporting significant myocardial gene expression. CONCLUSIONS: Percutaneous delivery of an adenovirus solution using a continuous infusion of oxygenated Krebs solution via a Langendorff apparatus appears to be a gene delivery modality offering the best compromise of gene expression and clinical utility to maximize any potential therapeutic outcome.

Adenoviridae↗

Variability of metabolite yield using STEAM or PRESS sequences in vivo at 3.0 T, illustrated with myo-inositol.

Using as an example the myo-inositol (mI) band at approximately 3.6 ppm in the proton spectrum from brain, an evaluation is presented that highlights the difficulties of quantifying metabolites with strongly coupled spins with either STEAM or PRESS and demonstrates some advantages of prospective sequence analysis when measuring their concentrations. The analysis emphasizes the variation in coupled-spin signal yield and lineshape, compared with that of uncoupled singlets such as N-acetylaspartate, a variation that differs from one metabolite spin system to another. This difference in variation between a target metabolite (e.g., mI) and its contaminating background metabolites (e.g., glutamate and taurine, etc.) is shown to provide in certain circumstances a substantial reduction in background contamination (both metabolite and macromolecule) while maintaining sufficient signal-to-noise ratio for precise quantification. For example, sequence times are demonstrated, both for STEAM and for PRESS, that, relative to the short echo-time sequences typical in the literature, enhance the signal to metabolite background of the 3.6-ppm band of mI by factors of 1.7 and 1.3, respectively, essentially eliminate the macromolecular baseline, and yet in vivo retain an S/N approximately 10 in both cases.

Brain↗

Measurement of skeletal muscle perfusion during postischemic reactive hyperemia using contrast-enhanced MRI with a step-input function.

The regional distribution of skeletal muscle blood flow was measured during postischemic reactive hyperemia using Gd-DTPA contrast-enhanced (CE) MRI. The release of an occlusive thigh cuff was used to deliver a step-input of contrast concentration that was coincident with the onset of reactive hyperemia. A first-order tracer kinetic equation was used to estimate the unidirectional influx constant, Ki (ml/100 g/min), and the distribution volume of Gd-DTPA in the tissue, v(e), from T1-weighted images acquired with saturation recovery (SR) steady-state free precession (SSFP) and spoiled gradient-echo (SPGR) protocols. The capillary permeability surface (PS) area increased significantly during reactive hyperemia, which facilitated rapid extraction of Gd-DTPA during the first pass. Regional muscle group studies from 11 normal volunteers yielded blood flow (Ki) values of 108.3 +/- 34.1 ml/100 g/min in the gastrocnemius, 184.3 +/- 41.3 ml/100 g/min in the soleus, and 122.4 +/- 34.4 ml/100 g/min in the tibialis anterior. The distribution volumes (v(e)) in the corresponding muscle groups were respectively 8.3% +/- 2.1%, 9.3% +/- 1.9%, and 7.9% +/- 1.8% from the kinetic model, and 8.8% +/- 2.4%, 9.1% +/- 1.9%, and 7.2% +/- 1.4% from tissue relaxometry studies. Bulk blood flow studies in the same volunteers using phase-contrast velocimetry (popliteal artery) yielded significantly lower flow values, but with a correlation coefficient R2 = 0.62 and P = 0.004.

Algorithms↗

Studying zinc biology with fluorescence: ain't we got fun?

Zinc has emerged as a metal ion of substantial interest in biology and medicine, especially in neuroscience, gene transcription, the immune response, and mammalian reproduction. Fueling these advances in understanding has been the development of new fluorescence-based indicator systems for zinc with unprecedented sensitivity and selectivity. This review summarizes recent progress in the development of fluorescence-based sensors and biosensors for zinc, with a view to evaluating their suitability for use with biologically derived specimens, especially in vivo and in situ.

Animals↗

Functional assessment of myoblast transplantation for cardiac repair with magnetic resonance imaging.

BACKGROUND: Contraction of transplanted myoblasts and their effects on function and remodeling after myocardial infarction remain controversial. AIM: We used magnetic resonance imaging (MRI) to study wall thickening and left ventricular (LV) function and geometry after myoblast transplantation. METHODS AND RESULTS: Three weeks after cryo-infarction rabbits were randomized to receive an injection of approximately 2 x 10(8) myoblasts (n=8) or medium (n=9) into the scar. Cine MRI and contrast enhanced (ce) MRI images were acquired before injection (baseline) and 4 weeks later (endpoint). Regional wall thickening was measured at the site of transmural hyperenhancement. In the control group, regional wall thickening decreased to -15.3+/-8.6% at baseline, which further decreased to -18.3+/-5.7% at endpoint. Further, end-diastolic volume increased from 3.96+/-0.27 to 5.00+/-0.46 ml and end-systolic volume from 2.23+/-0.19 to 2.96+/-0.30 ml (both P<0.05 vs. baseline), which was accompanied by increased LV wall volumes (P<0.05 vs. baseline). In contrast, myoblast transplantation increased regional wall thickening from -11.9+/-15.9% at baseline to 26.9+/-17.0% (P<0.05 vs. control), which resulted in significantly improved two-dimensional ejection fractions at the infarct level and prevented the increase in end-diastolic and end-systolic volumes and wall volume. CONCLUSION: Intracardiac myoblast transplantation after myocardial infarction improves regional wall thickening and prevents progressive left ventricular remodeling.

Animals↗

Intracardiac transplantation of a mixed population of bone marrow cells improves both regional systolic contractility and diastolic relaxation.

BACKGROUND: Pre-clinical and clinical studies suggest that transplantation of bone marrow-derived stem cells can improve global cardiac function. However, no quantitative assessment of regional systolic contraction and correlation with phenotype has been made. Therefore, we used our model of cryoinfarcted rabbit myocardium for intracardiac transplantation of a mixed population of bone marrow-derived cells and assessed both regional function and myogenic conversion of the cells. METHODS: Nineteen New Zealand white rabbits underwent cryoinjury of the left ventricle. Autologous bone marrow (BM) cells were expanded in vitro. After 2 weeks, either 1 x 10(8) mixed BM-derived progenitor cells (BM group, n = 11) or vehicle (control group, n = 8) were injected into the cryoinjured region. Regional systolic function was measured using micromanometry and sonomicrometry before and 4 weeks after cell injection; cell phenotype was evaluated histologically. RESULTS: All animals in the BM group significantly improved both systolic shortening (0.11 +/- 0.7 vs -0.05 +/- 0.05 mm in the control group, p < 0.05) and regional stroke work when compared with control (9.6 +/- 2.4 vs -1.2 +/- 1.2 mm . mm Hg, p < 0.003). In addition, the BM group had improved global diastolic function, as measured by minimum dP/dt and end-diastolic pressure. On histologic assessment, BM cells differentiated toward a myogenic phenotype. CONCLUSIONS: Transplanting a mixed population of marrow-derived cells that can adopt a myogenic phenotype improves regional contractility and diastolic relaxation after myocardial infarction.

Animals↗

A Gbetagamma inhibitor reduces intimal hyperplasia in aortocoronary saphenous vein grafts.

OBJECTIVE: Approximately 50% of aortocoronary saphenous vein grafts are occluded 10 years after coronary revascularization surgery. Intimal hyperplasia, a critical component in saphenous vein graft failure, is defined by vascular smooth muscle cell proliferation, which is mediated in part by betagamma subunits of heterotrimeric G proteins (G(betagamma)) and downstream effectors such as mitogen-activated protein kinases. A peptide consisting of the carboxyl-terminus of the beta-adrenergic receptor kinase (betaARKct) binds G(betagamma), thereby inhibiting G(betagamma) signaling. Utilizing a recombinant adenovirus containing the coding sequence for the betaARKct peptide (AdbetaARKct), this study investigates whether treatment of the vein graft with AdbetaARKct reduces intimal hyperplasia in a large animal model of aortocoronary saphenous vein graft intimal hyperplasia. METHODS: Twenty-seven dogs (27-32 kg) underwent aortocoronary bypass grafting to the left anterior descending artery using autologous saphenous vein. Vein grafts were treated with saline (n = 8), an empty adenovirus (n = 8), or AdbetaARKct (n = 8). A subset of dogs (n = 3) were sacrificed on postoperative day 7 and betaARKct expression confirmed by Northern blotting. RESULTS: Arteriograms performed on postoperative day 90 confirmed that saphenous vein grafts were patent. At postoperative day 90, AdbetaARKct-treated grafts demonstrated reduced intimal area compared to empty virus and saline treated animals (P < .05). Additionally, AdbetaARKct treatment of isolated vascular smooth muscle cells in vitro inhibited mitogen-activated protein kinase activation and decreased overall vascular smooth muscle cell proliferation. CONCLUSION: This study demonstrates that betaARKct expression in aortocoronary saphenous vein grafts reduces intimal hyperplasia and decreases vascular smooth muscle cell proliferation in vitro via inhibition of G(betagamma)-mediated mitogen-activated protein kinase activation. Modulation of G(betagamma) via betaARKct may represent a novel therapy to reduce intimal hyperplasia and saphenous vein graft failure.

Animals↗

Analysis of allosteric signal transduction mechanisms in an engineered fluorescent maltose biosensor.

We previously reported the construction of a family of reagentless fluorescent biosensor proteins by the structure-based design of conjugation sites for a single, environmentally sensitive small molecule dye, thus providing a mechanism for the transduction of ligand-induced conformational changes into a macroscopic fluorescence observable. Here we investigate the microscopic mechanisms that may be responsible for the macroscopic fluorescent changes in such Fluorescent Allosteric Signal Transduction (FAST) proteins. As case studies, we selected three individual cysteine mutations (F92C, D95C, and S233C) of Escherichia coli maltose binding protein (MBP) covalently labeled with a single small molecule fluorescent probe, N-((2-iodoacetoxy)ethyl)-N-methyl)amino-7-nitrobenz-2-oxa-1,3-diazole (NBD), each giving rise to a robust FAST protein with a distinct maltose-dependent fluorescence response. The fluorescence emission intensity, anisotropy, lifetime, and iodide-dependent fluorescence quenching were determined for each conjugate in the presence and absence of maltose. Structure-derived solvent accessible surface areas of the three FAST proteins are consistent with experimentally observed quenching data. The D95C protein exhibits the largest fluorescence change upon maltose binding. This mutant was selected for further characterization, and residues surrounding the fluorophore coupling site were mutagenized. Analysis of the resulting mutant FAST proteins suggests that specific hydrogen-bonding interactions between the fluorophore molecule and two tyrosine side-chains, Tyr171 and Tyr176, in the open state but not the closed, are responsible for the dramatic fluorescence response of this construct. Taken together these results provide insights that can be used in future design cycles to construct fluorescent biosensors that optimize signaling by engineering specific hydrogen bonds between a fluorophore and protein.

Allosteric Site↗

Cardioprotective effects of erythropoietin in the reperfused ischemic heart: a potential role for cardiac fibroblasts.

Erythropoietin has recently been shown to have effects beyond hematopoiesis such as prevention of neuronal and cardiac apoptosis secondary to ischemia. In this study, we evaluated the in vivo protective potential of erythropoietin in the reperfused rabbit heart following ventricular ischemia. We show that "preconditioning" with erythropoietin activates cell survival pathways in myocardial tissue in vivo and adult rabbit cardiac fibroblasts in vitro. These pathways, activated by erythropoietin in both whole hearts and cardiac fibroblasts, are also activated acutely by ischemia/reperfusion injury. Moreover, in vivo studies indicate that erythropoietin treatment either prior to or during ischemia significantly enhances cardiac function and recovery, including left ventricular contractility, following myocardial ischemia/reperfusion. Our data indicate that a contributing in vivo cellular mechanism of this protection is mitigation of myocardial cell apoptosis. This results in decreased infarct size as evidenced by area at risk studies following in vivo ischemia/reperfusion injury, translating into more viable myocardium and less ventricular dysfunction. Therefore, erythropoietin treatment may offer novel protection against ischemic heart disease and may act, at least in part, by direct action on cardiac fibroblasts and myocytes to alter survival and ventricular remodeling.

Animals↗

Flow-gated phase-contrast MRI using radial acquisitions.

Phase-contrast (PC) MRI is a noninvasive method for imaging blood and tissue velocity. PC experiments are typically segmented into many cardiac cycles in order to obtain sufficient spatial and temporal resolution, and thus require a gating signal to properly combine the data from multiple cardiac cycles. Although the surface electrode ECG is the gating waveform of choice for cardiovascular MRI, alternative gating methods are required for fetal cardiac imaging (due to the unavailability of fetal ECG signals) and for cases of ECG contamination via the strong magnetic fields within the MR scanner. This study demonstrates the feasibility of using imaging data from flow-encoded MRI experiments to derive times for cardiac gating. An undersampled radial k-space acquisition method is used to measure an image-derived flow-gating waveform in real-time, from which the gating times are derived. These gating times are used to reconstruct a conventional gated-segmented image series by combining the real-time data from multiple heartbeats. Flow-gated PC experiments were performed on five normal volunteers with slice prescriptions in four anatomic regions. The standard deviation (SD) of the difference between the flow-gating and ECG gating times ranged from 5 ms to 12 ms.

Aorta↗