PubMed Health⌕ Search

Biomedical subjects

Richard C Brunken

Publications and source records attributed to Richard C Brunken.

11 recordsLinked to original sources

A knowledge-based method for reducing attenuation artefacts caused by cardiac appliances in myocardial PET/CT.

Attenuation artefacts due to implanted cardiac defibrillator leads have previously been shown to adversely impact cardiac PET/CT imaging. In this study, the severity of the problem is characterized, and an image-based method is described which reduces the resulting artefact in PET. Automatic implantable cardioverter defibrillator (AICD) leads cause a moving-metal artefact in the CT sections from which the PET attenuation correction factors (ACFs) are derived. Fluoroscopic cine images were measured to demonstrate that the defibrillator's highly attenuating distal shocking coil moves rhythmically across distances on the order of 1 cm. Rhythmic motion of this magnitude was created in a phantom with a moving defibrillator lead. A CT study of the phantom showed that the artefact contained regions of incorrect, very high CT values and adjacent regions of incorrect, very low CT values. The study also showed that motion made the artefact more severe. A knowledge-based metal artefact reduction method (MAR) is described that reduces the magnitude of the error in the CT images, without use of the corrupted sinograms. The method modifies the corrupted image through a sequence of artefact detection procedures, morphological operations, adjustments of CT values and three-dimensional filtering. The method treats bone the same as metal. The artefact reduction method is shown to run in a few seconds, and is validated by applying it to a series of phantom studies in which reconstructed PET tracer distribution values are wrong by as much as 60% in regions near the CT artefact when MAR is not applied, but the errors are reduced to about 10% of expected values when MAR is applied. MAR changes PET image values by a few per cent in regions not close to the artefact. The changes can be larger in the vicinity of bone. In patient studies, the PET reconstruction without MAR sometimes results in anomalously high values in the infero-septal wall. Clinical performance of MAR is assessed by two physicians' inspection of images generated in 30 patients with and without MAR. Noticeable image differences are judged in 14 of 28 (50%) observations with AICD leads, and significant clinical impact is judged in 2 of 28 (7%) of those observations. A polar map analysis shows significant differences in 10 of 14 (71%) studies with AICD leads, and 0 of 16 (0%) studies without AICD leads. These results show that the MAR method is successful in reducing the magnitude of the metal artefact without incorrectly altering cases without metal artefact. In spite of profound changes to the CT image from the moving metal, the PET ACF in that study was changed by no more than 20%.

Artifacts↗

PET and PET/CT imaging: what clinicians need to know.

Positron emission tomography (PET), once the sole province of academic medical centers, is rapidly being adopted in daily clinical practice in community hospitals and outpatient centers. It can be especially useful in oncology, cardiology, and neurology. We provide an overview of the fundamentals of PET and PET with computed tomography (PET/CT) and discuss their current clinical utility.

Humans↗

Myocardial perfusion reserve in adults with cyanotic congenital heart disease.

In patients with cyanotic congenital heart disease (CCHD), a right-to-left shunt results in systemic hypoxemia. Systemic hypoxemia incites a compensatory erythrocytosis, which increases whole blood viscosity. We considered that these changes might adversely influence myocardial perfusion in CCHD patients. Basal and hyperemic (intravenous dipyridamole) perfusion measurements were obtained with [13N]ammonia positron emission tomographic imaging in left (LV) and right (RV) ventricular and septal myocardium in 14 adults with CCHD [age: 34.1 yr (SD 6.5)]; hematocrit: 62.2% (SD 4.8)] and 10 healthy controls [age: 34.1 yr (SD 6.5)]. In patients, basal perfusion measurements were higher in LV [0.77 (SD 0.24) vs. 0.55 ml x min(-1) x g(-1) (SD 0.09), P < 0.02], septum [0.71 (SD 0.16) vs. 0.49 ml x min(-1) x g(-1) (SD 0.09), P < 0.001], and RV [0.77 (SD 0.30) vs. 0.38 ml x min(-1) x g(-1) (SD 0.09), P < 0.001]. However, basal measurements normalized for the rate-pressure product were similar to those of controls. Calculated oxygen delivery relative to rate-pressure product was higher in the patients [2.2 (SD 0.8) vs. 1.6 (SD 0.4) x 10(-5) ml O2 x min(-1) x g tissue(-1) x (beats x mmHg)(-1) in the LV, P < 0.05, and 2.0 (SD 0.7) vs. 1.4 (SD 0.3) x 10(-5) ml O2 x min(-1) x g tissue(-1) x (beats x mmHg)(-1) in the septum, P < 0.01]. Hyperemic perfusion measurements in CCHD patients did not differ from controls [LV, 1.67 (SD 0.60) vs. 1.95 ml x min(-1) x g(-1) (SD 0.46); septum, 1.44 (SD 0.56) vs. 1.98 ml x min(-1) x g(-1) (SD 0.69); RV, 1.56 (SD 0.56) vs. 1.65 ml x min(-1) x g(-1) (SD 0.64), P = not significant], and coronary vascular resistances were comparable [LV, 55 (SD 25) vs. 48 mmHg x ml(-1) x g x min (SD 16); septum, 67 (SD 35) vs. 50 mmHg x ml(-1) x g x min (SD 21); RV, 59 (SD 26) vs. 61 mmHg x ml(-1) x g x min (SD 27), P = not significant]. These findings suggest that adult CCHD patients have remodeling of the coronary circulation to compensate for the rheologic changes attending chronic hypoxemia.

Adult↗

Prediction of death or myocardial infarction by exercise single photon emission computed tomography perfusion scintigraphy in patients who have had recent coronary artery stenting.

BACKGROUND: Although practice guidelines do not recommend routine exercise testing of patients after coronary stenting, several small studies have suggested that stress myocardial perfusion imaging can provide prognostic information about future adverse cardiac events. We sought to determine if exercise nuclear testing provides independent prognostic information in patients after coronary stenting. METHODS: We analyzed the outcomes of 370 patients who underwent dual isotope exercise nuclear scintigraphy at least 1 month after coronary stenting and had testing between April 1996 and May 2002. Patients were classified according to presence or absence of any ischemia. The primary endpoint was all-cause mortality or myocardial infarction (MI) during a median of 30 months (range 6-59) of follow-up. RESULTS: There were 86 patients (23%) who had ischemia. Major events--death or MI--occurred in 62 patients including 22 deaths. Among patients with no ischemia, the 30-month event rate was 9.1%, whereas among patients with ischemia, the event rate was 17.0% (P = .001). After adjusting for age, sex, standard cardiac risk factors, cardiac history, left ventricular ejection fraction, angiographic findings, procedural variables, exercise capacity, and heart-rate dynamics, the presence of scintigraphic evidence of ischemia predicted death or MI (adjusted hazard ratio 2.08, 95% CI 1.21-3.56, P = .008). The presence of ischemia similarly predicted events in asymptomatic patients (adjusted hazard ratio 2.19, 95% CI 1.17-4.11, P = .015). CONCLUSIONS: In patients with recent coronary stent placement, reversible nuclear perfusion defects independently predicted risk of death or MI.

Angioplasty, Balloon, Coronary↗

Do implanted pacemaker leads and ICD leads cause metal-related artifact in cardiac PET/CT?

UNLABELLED: Artifacts related to metallic implants are an established limitation of CT-based attenuation correction (CT-AC) in PET/CT. However, the impact of metallic components of pacemaker leads and implantable cardioverter defibrillator (ICD) leads on the accuracy of cardiac PET has not been evaluated. The goal of this study was to investigate the magnitude of artifacts related to pacing and defibrillation leads in both phantom and patient studies. METHODS: Images were acquired on a PET/CT scanner using CT-AC and were compared with those obtained on a dedicated PET scanner using transmission source-based attenuation correction. Phantoms consisting of pacemaker leads and ICD leads submerged in uniform background activity solution were imaged, and regions were analyzed to measure radionuclide concentrations at known lead locations relative to background. In addition, 15 cardiac 18F-FDG patients (having either pacing leads, defibrillation leads, or both) were imaged on both PET/CT and PET scanners. Images were visually and quantitatively assessed to determine whether artifact related to the implanted leads was present and, if so, its severity relative to surrounding myocardium. RESULTS: In phantom studies, artifacts caused by pacing lead electrodes were barely noticeable, but artifacts arising from highly radioopaque ICD shock coil electrodes were clearly apparent. In the patient studies, no artifacts from pacing leads were identified. However, significant artifact was observed in 50% of the patient studies with ICD leads. In the affected areas, local myocardial uptake in PET/CT images using CT-AC was, on average, 30% higher than that in the corresponding PET images. CONCLUSION: Although pacemaker leads do not appear to cause artifact in cardiac PET/CT images, ICD leads frequently do result in artifacts of sufficient magnitude to impact clinical image interpretation. Accordingly, software-based corrections in CT-AC algorithms appear necessary for accurate cardiac imaging with PET/CT.

Artifacts↗

Ischemic and viable myocardium in patients with non-Q-wave or Q-wave myocardial infarction and left ventricular dysfunction: a clinical study using positron emission tomography, echocardiography, and electrocardiography.

OBJECTIVES: We investigated whether patients with non-Q-wave myocardial infarction (NQMI) have more ischemic viable myocardium (IVM) than patients with Q-wave myocardial infarction (QMI). BACKGROUND: Non-Q-wave myocardial infarction is associated with higher incidences of cardiac events than QMI, suggesting more myocardium at risk in NQMI. METHODS: To identify myocardial ischemia, hibernation, and scar, the resting and stress (82)rubidium perfusion and F-18 fluorodeoxyglucose metabolic positron emission tomographic imaging (PET) was performed in 64 consecutive patients with NQMI (n = 21) or QMI (n = 43). Echocardiography was performed for assessment of left ventricular function and wall motion index (WMI). The relationships between PET, echocardiographic, and electrocardiographic findings were analyzed. RESULTS: There were no significant differences in left ventricular ejection fraction (LVEF) between NQMI and QMI groups (28 +/- 10% vs. 25 +/- 11%, p > 0.05). Ischemic and viable myocardium was more common in NQMI than in QMI (91% vs. 61%, p < 0.05). The total amount of IVM was significantly higher in NQMI than in QMI (6.5 +/- 5.2 vs. 2.9 +/- 2.8 segments, p < 0.001). Neither the number of Q waves, residual ST-segment depression of >or=0.5 mm or elevation of >or=1 mm, nor LVEF and WMI were significant predictors for IVM. Wall motion index correlated with scar segments (r = 0.54, p < 0.001) and LVEF (r = -0.67, p < 0.001). CONCLUSIONS: Ischemic and viable myocardium is common in patients with NQMI and left ventricular dysfunction, suggesting that aggressive approaches should be taken to salvage the myocardium at risk in such patients.

Case-Control Studies↗

PET abnormalities in patients with nonischemic cardiomyopathy.

BACKGROUND: The abnormalities in dilated cardiomyopathy (DCM) are generally considered diffuse and to affect the left ventricle in a global manner. However, regional wall motion abnormalities and metabolic defects may also occur to varying, but unclear degrees. QRS width and metabolic defects on positron emission tomography (PET) correlate with survival. We sought to ascertain the prevalence of regional defects in DCM by multiple imaging modalities and to establish the relationship between QRS width and these defects. METHODS: In consecutive patients with advanced nonischemic DCM, undergoing cardiac transplant evaluation, we reviewed multiple imaging modalities (PET, 2-dimensional echocardiography, and radionuclide ventriculography) to quantify the incidence of regional metabolic and wall motion abnormalities and correlate them with clinical and electrocardiographic parameters. RESULTS: Of 44 patients studied, PET imaging revealed scar in 91% of patients, with a mean of 25 +/- 18% of the left ventricle involved, predominantly in the distribution of the left anterior descending artery. Regional wall motion abnormalities occurred in 51% of patients who underwent echocardiography and 59% of patients who underwent nuclear scintigraphy (with only 70% concordance). QRS duration on the surface electrocardiogram correlated positively with the degree of scarring (r=.52, P=.0007). CONCLUSIONS: The presence of scar (matched perfusion and metabolic defects) on PET scanning in patients with advanced DCM is not always indicative of coronary disease. Thus coronary angiography is usually required to define the etiology of systolic dysfunction. The extent of scar correlates with QRS duration. This may have implications for the application of cardiac resynchronization therapy.

Adult↗

Importance of ischemic and viable myocardium for patients with chronic ischemic mitral regurgitation and left ventricular dysfunction.

The objective of this investigation is to determine the importance of ischemic viable myocardium for clinical outcomes in patients with severe chronic ischemic mitral regurgitation and severe left ventricular dysfunction undergoing surgical correction of mitral regurgitation. The study included 54 patients with left ventricular ejection fraction of 27 +/- 9%. Positron emission tomography was performed preoperatively for the identification of ischemic viable myocardium. The patients with a large amount of ischemic viable myocardium (> or =5 segments) had significantly lower 6-month mortality rates than those with less viable myocardium (0 to 4 segments) after the surgery.

Cause of Death↗

Mutual information-based multimodality registration of cardiac ultrasound and SPECT images: a preliminary investigation.

BACKGROUND: Ultrasound (US) and single photon emission computed tomography (SPECT) are the two most commonly prescribed procedures for diagnosing coronary artery disease (CAD). We have demonstrated the feasibility of multimodality registration of two-dimensional (2D) and three-dimensional (3D) cardiac US images with cardiac SPECT images with an aim to simultaneously present the complementary anatomical and perfusion information from the two modalities. We have also tested the clinicians' assessment of the clinical adequacy of the registered images. METHODS AND RESULTS: We have demonstrated temporal and spatial registration for nine sets of cardiac US and SPECT cine loops covering the entire cardiac cycle. Temporal alignment was performed by interpolation of existing SPECT images at cardiac phases corresponding to available US images. Spatial registration was performed in 3D image space using a mutual information-based approach. Experts from echocardiography and nuclear medicine determined the clinical utility of the registration by rating each registration on a scale of 1 to 5, a rating of 3 or above indicating clinical utility. 2DUS-SPECT registration (five cases) received an average rating of 4.2, whereas 3DUS-SPECT registration (four cases) received an average rating of 2.85. By one-sample t test, the overall evaluations (mean 3.58) were greater than the pre-specified clinical cut-off of 3 with p < 0.05, indicating likelihood of clinical utility. CONCLUSION: Our method demonstrates the feasibility of registering cardiac US and SPECT images in their present as well as possible future forms. Such registration has the potential to provide a more accurate and powerful tool for diagnosing CAD.

Clinical Protocols↗

Does chronic ST segment elevation following Q wave myocardial infarction exclude tissue viability?

PURPOSE: Electrocardiographic (ECG) ST segment elevation lasting 2 or more weeks following Q wave myocardial infarction has been associated with 'ventricular aneurysm' and absence of tissue viability. Regional systolic dysfunction may reflect either viable myocardium or scar. Positron emission-tomographic (PET) imaging can distinguish viable from nonviable tissue. We hypothesized that patients with chronic ST segment elevation after Q wave infarction might demonstrate salvageable myocardium in the infarct region. METHODS: The ECGs of 1,229 sequential patients undergoing PET scans for viability assessment were reviewed by an electrocardiographer to identify individuals with chronic anteroseptal Q wave infarctions with persistent ST segment elevation exceeding 1 mV. Patients with QRS duration longer than 0.14 ms or rhythm other than sinus were excluded. Viability was considered present if either a reversible stress-induced perfusion defect (ischemia) or a resting perfusion-metabolism mismatch (hibernation) was identified. RESULTS: Anteroseptal ECG Q wave infarction was identified in 132 subjects (74% male, age 61 +/- 12 years). Chronic ST segment elevation was present in 84 subjects (64%) and absent in 48. Baseline clinical characteristics and left ventricular systolic function were similar in both groups. 63% of those with and 56% of those without chronic ST elevation had viable myocardium. No relationship was noted between chronic ST segment elevation and the presence or absence of myocardial viability. CONCLUSIONS: Chronic ST segment elevation after anteroseptal Q wave myocardial infarction does not exclude myocardial viability in the 'infarct zone'. Evaluation of residual tissue viability is indicated to assess the benefit of revascularization in patients with Q wave infarction and chronic ST segment elevation.

Aged↗