PubMed Health⌕ Search

Biomedical subjects

Richard C Lanza

Publications and source records attributed to Richard C Lanza.

2 recordsLinked to original sources

Sub-millimeter technetium-99m calibration sources.

PURPOSE: Small animal radioscintigraphic imaging systems aim to achieve sub-millimeter resolution. At the present time, sub-millimeter calibration sources that can be placed at will within an imaged volume are not readily available. We have developed a method for producing technetium-99m (Tc-99m) sources in less than 15 minutes with readily available reagents. PROCEDURES: Tc-99m pertechnetate [TcO(4)](-) was incubated with 45 microm to 106 microm diameter spherical anion exchange beads, washed, and mounted as desired for instrument calibration. RESULTS: The procedure yields spherical sources having between 6.8 microCi to 11.1 microCi of Tc-99m per source. This work shows that dual imaging of these sources using white light and radioscintigraphy permits measurement of system performance with high precision. CONCLUSION: Easily prepared, sub-millimeter Tc-99m spherical calibration sources are described, and it is demonstrated that such sources are useful for measuring the resolution and sensitivity of radioscintigraphic systems, such as those designed for small animal imaging.

Journal Article↗

Coded aperture nuclear scintigraphy: a novel small animal imaging technique.

We introduce and demonstrate the utility of coded aperture (CA) nuclear scintigraphy for imaging small animals. CA imaging uses multiple pinholes in a carefully designed mask pattern, mounted on a conventional gamma camera. System performance was assessed using point sources and phantoms, while several animal experiments were performed to test the usefulness of the imaging system in vivo, with commonly used radiopharmaceuticals. The sensitivity of the CA system for 99mTc was 4.2 x 10(3) cps/Bq (9400 cpm/microCi), compared to 4.4 x 10(4) cps/Bq (990 cpm/microCi) for a conventional collimator system. The system resolution was 1.7 mm, as compared to 4-6 mm for the conventional imaging system (using a high-sensitivity low-energy collimator). Animal imaging demonstrated artifact-free imaging with superior resolution and image quality compared to conventional collimator images in several mouse and rat models. We conclude that: (a) CA imaging is a useful nuclear imaging technique for small animal imaging. The advantage in signal-to-noise can be traded to achieve higher resolution, decreased dose or reduced imaging time. (b) CA imaging works best for images where activity is concentrated in small volumes; a low count outline may be better demonstrated using conventional collimator imaging. Thus, CA imaging should be viewed as a technique to complement rather than replace traditional nuclear imaging methods. (c) CA hardware and software can be readily adapted to existing gamma cameras, making their implementation a relatively inexpensive retrofit to most systems.

Animals↗