Publications and source records attributed to Richard D Oleschuk.

13 recordsLinked to original sources

Chemical force titrations of antigen- and antibody-modified poly(methylmethacrylate).

Poly(methylmethacrylate) (PMMA) is a versatile polymer that displays desirable properties for development of cheap and disposable microfluidic devices for sensing biomolecular interactions. Atomic force microscopy (AFM) and chemical force titrations were used to determine the efficacy of surface modifications made to accommodate protein-substrate linkage. AFM images show the effects on surface morphology of carboxylated-, amine-, hCG antigen- and anti-hCG antibody-modified PMMA substrates. Confocal microscopy was used to determine the fluorescent intensity of labeled antibody species on the PMMA substrate, confirming the success of surface antigen/antibody immobilization. Surface pK(1/2) value for carboxylic acid and amine species grafted on PMMA were determined. When carboxylic acid or amine-terminated tips were titrated against PMMA samples terminated with the hCG antigen and anti-hCG antibody, peaks appeared in the force titration curve consistent with the pI range of the antigen or antibody species. Strong adhesive forces were present at pH values above 7.0 when the antigen was present on the PMMA substrate, and these were attributed to hydrophobic interactions between the antigen and the alkane "linker" chain attaching the amine or carboxylate group to the AFM tip. Such hydrophobic interactions were not observed with the carboxylic acid or amine/antibody combinations suggesting that the surface-linked antibody was more resistant to denaturation under higher pH. The results demonstrated the feasibility of using AFM approaches for interrogating protein grafting strategies in the fabrication of PMMA-based microsystems.

Antibodies↗

Lectin affinity chromatography using porous polymer monolith assisted nanoelectrospray MS/MS.

An affinity porous polymer monolith is utilized as a nanoelectrospray emitter as well as an online affinity capture column for the preconcentration of glycans. Porous polymer monolith (PPM) assisted electrospray provides a facile methodology for coupling microfluidics to mass spectrometry that is sheathless and with zero dead volume. Affinity PPM was photopolymerized using glycidyl methacrylate/ethylene dimethacrylate utilizing different porogenic solvents based on aliphatic alcohols to provide PPMs with a variety of pore sizes. The use of longer alkyl chain alcohols decreased the pore size of the formed PPM as indicated by the higher flow back pressure generated. The effect of the pore size on the stability of the electrospray was tested showing higher stability of the TIC with lower pore size. A lectin, namely Concanavaline A, was immobilized on glycidyl methacrylate/ethylene dimethacrylate using the Schiff base method to provide an affinity monolith for high mannose glycans. The amount of the lectin immobilized was studied as a function of the porogenic solvent used in the polymerization. The glycopeptides of the glycoprotein Ribonuclease B was preconcentrated on the affinity PPM sprayer and detected by tandem MS.

Chromatography, Affinity↗

Capillary electrophoresis absorption detection using fiber-loop ring-down spectroscopy.

The application of phase-shift, fiber-loop, ring-down spectroscopy (PS-FLRDS) as an on-line detector for capillary electrophoresis (CE) of biomolecules is demonstrated. CE was conducted using a custom-designed capillary/fiber interface coupled to an absorption detector, which is based on the ring-down of an optical signal in a closed fiber waveguide loop. The ring-down times were obtained by measuring the phase difference between intensity modulated light entering and exiting the fiber loop. The incorporation of a microlens to enhance transmission through the sample gap led to an improvement of the sensitivity by up to 80% compared to the square-cut fiber and a reduction in the detection limit. The performance of the PS-FLRDS absorption technique as an online detector was characterized by flow injection through a capillary. Good repeatability and linear response were obtained, and the detection limit using the lensed fiber/capillary interface system was determined to be alpha(min) = 1.6 cm(-1) for an absorption path of approximately 30 microm. PS-FLRDS coupled to CE was also applied to the analysis of human serum albumin (HSA) by using a NIR dye as a noncovalent label. The excess free dye and the dye/protein complex were resolved. The labeling coefficient was determined to be approximately 6, and good repeatability of peak areas (RSD = 8.7%) was obtained for the analysis of HSA. Furthermore, an excellent linear response (R2 > 0.99) was obtained between the peak areas and concentrations of HSA. The detection limit of labeled HSA was determined to be 1.67 microM.

Electrophoresis, Capillary↗

Fabrication of porous polymer monoliths in polymeric microfluidic chips as an electrospray emitter for direct coupling to mass spectrometry.

Coupling of polymeric microfluidic devices to mass spectrometry is reported using porous polymer monoliths (PPM) as nanoelectrospray emitters. Lauryl acrylate-co-ethylene dimethacrylate porous polymer monolith was photopatterned for 5 mm at the end of the channel of microfluidic devices fabricated from three different polymeric substrate materials, including the following: poly(dimethylsiloxane) (PDMS), poly(methyl methacrylate) (PMMA), and cyclic olefin copolymer (COC). Spraying directly from the end of the chip removes any dead volume associated with inserted emitters or transfer lines, and the presence of multiple pathways in the PPM prevents the clogging of the channels, which is a common problem in conventional nanospray emitters. Spraying from a microfluidic channel having a PPM emitter produced a substantial increase in TIC stability and increased sensitivity by as much as 70x compared to spraying from an open end chip with no PPM. The performance of PPM emitter in COC, PMMA, and PDMS chips was compared in terms of stability and reproducibility of the electrospray. COC chips showed the highest reproducibility in terms of chip-to-chip performance, which can be attributed to the ease and reproducibility of the PPM formation due to the favorable optical and chemical properties of COC. We have further tested the performance of the COC chips by constant infusion of poly(propylene glycol) solution at organic content ranging from 10 to 90% methanol and at flow rates ranging from 50 to 1000 nL/min, showing optimum spraying conditions (RSD < 5%) at 50-70% organic content and at flow rates from 100 to 500 nL/min. The PPM sprayer was also used for protein preconcentration and desalting prior to mass spectrometric detection, and results were comparable with a chip spraying from an electrospray tip.

Microfluidics↗

Fabrication and characterization of poly(methylmethacrylate) microfluidic devices bonded using surface modifications and solvents.

The fabrication of polymer microchips allows inexpensive, durable, high-throughput and disposable devices to be made. Poly(methylmethacrylate) (PMMA) microchips have been fabricated by hot embossing microstructures into the substrate followed by bonding a cover plate. Different surface modifications have been examined to enhance substrate and cover plate adhesion, including: air plasma treatment, and both acid catalyzed hydrolysis and aminolysis of the acrylate to yield carboxyl and amine-terminated PMMA surfaces. Unmodified PMMA surfaces were also studied. The substrate and cover plate adhesion strengths were found to increase with the hydrophilicity of the PMMA surface and reached a peak at 600 kN m(-2) for plasma treated PMMA. A solvent assisted system has also been designed to soften less than 50 nm of the surface of PMMA during bonding, while still maintaining microchannel integrity. The extent to which both surface modifications and solvent treatment affected the adhesion of the substrate to the cover plate was examined using nanoindentation methods. The solvent bonding system greatly increased the adhesion strengths for both unmodified and modified PMMA, with a maximum adhesion force of 5500 kN m(-2) achieved for unmodified PMMA substrates. The bond strength decreased with increasing surface hydrophilicity after solvent bonding, a trend that was opposite to what was observed for non-solvent thermal bonding.

Equipment Design↗

Chemical force titrations of amine- and sulfonic acid-modified poly(dimethylsiloxane).

Chemical force titrations-measurements of the adhesive interaction between a pair of suitably chemically modified atomic force microscopy (AFM) tip and sample surfaces as a function of pH-have been carried out for various combinations of silanol, amine, carboxylic acid, and sulfonic acid functional groups on both tip and sample. The primary surface material studied was poly(dimethylsiloxane) (PDMS). Surface modification was carried out using a plasma oxidation process to form silanol sites; further modification with amine or sulfonic acid sites was carried out by reaction of the silanol sites with the appropriate trialkoxysilane derivative. AFM tips were also modified using trialkoxysilane compounds. In the cases of tip/sample combinations with the same functional group on each, surface pK(1/2) values could be determined. In several "mixed" tip/sample combinations, a peak appeared in the titration curve midway between the surface pK(1/2) values of the tip and sample, consistent with an ionic H-bonding model for the interactions. The amine/sulfonic acid pair showed more complex behavior; the amine-terminated tip/sulfonic acid-terminated PDMS surface force titration curve consisted of two peaks centered at pH 4 and pH 8. Reversing the tip/sample pair resulted in the peak positions being shifted upward by 1.0 pH unit. The peak appearing at lower pH is assigned to electrostatic interactions between the two oppositely charged surfaces, whereas the higher pH peak is believed to arise due to ionic H-bonding interactions. AFM images show the effects on surface patterning of amine- and sulfonic acid-modified PDMS surfaces that have undergone two different oxidation methods (air plasma oxidation and Tesla coil oxidation). The surface morphologies of freshly prepared and 24 h aged air plasma oxidized PDMS are also discussed in this study.

Journal Article↗

An evaluation of the performance of porous polymer monolith assisted electrospray.

A novel electrospray interface, which has distinct advantages over conventional pulled silica emitters, has been developed. This novel interface can be easily fabricated by forming a porous polymer monolith (PPM) at the end of a fused-silica capillary that facilitates a stable electrospray over a wide range of flow rates with only a modest increase in back-pressure. A comparison was made between the PPM-assisted electrospray and a commercial nanosprayer in terms of sensitivity, stability and robustness. A PPM-filled electrospray tip produced a day-to-day signal variation of 23% relative standard deviation (RSD) over a 3-day period when spraying a 1.0 microM test peptide solution. Furthermore, three different capillaries fabricated by the same process produced a signal variation of 17% RSD, indicating that the fabrication process shows good reproducibility. The multiple flow paths of the PPM function to split the flow and reduce clogging. Even following the accumulation of debris after prolonged use, a stable spray could still be generated with the PPM-filled capillary while the commercial nanosprayer ceased to function properly. In terms of sensitivity, PPM-assisted electrospray showed an enhancement in sensitivity at infusion flow rates between 100 to 1000 nL/min while commercial nanosprayers performed slightly better at flow rates below 100 nL/min. A sample purification step can be combined with the PPM-assisted sprayer, using the PPM as a stationary phase to desalt and preconcentrate samples prior to mass spectrometric detection.

Journal Article↗

Porous polymer monolith assisted electrospray from a glass microdevice.

The coupling of a lab-on-a-chip microfluidic device to a nanoelectrospray ionization mass spectrometer has the potential to automate many routine analytical procedures and produce a powerful analytical tool. However, past coupling strategies have relied on complex manufacturing steps including drilling and etching the device to attach a capillary or building a nanospray emitter directly into the device. This study shows that a nanospray emitter can be easily fabricated using a porous polymer monolith (PPM) at the end of a glass microdevice. These devices are able to obtain a stable electrospray at a variety of flow rates (50-500 nL/min) but optimal results are obtained at lower flow rates (50-100 nL/min) compatible with electroosmotic flow processes. The PPM is photo-patterned so that it can be placed in any position within the channel of the device with no dead volume. The porous character and the hydrophobic nature of the PPM both aid in development of a stable electrospray process. Total ion current traces for the constant infusion of leucine-enkephalin and PPG show relative standard errors as low as 4%, and produce mass spectra with good signal-to-noise (S/N 43) from only 2 fmol of material. In addition, multiple experiments in a given day show good repeatability with variability as low as 13%, and the multiple flow paths inherent in the PPM limit sprayer clogging.

Journal Article↗

Phase-shift fiber-loop ring-down spectroscopy.

Fiber-loop ring-down spectroscopy (FLRDS) is a recently developed absorption spectroscopic technique suitable for very small liquid samples. It is based on measurements of the optical decay constant of laser intensity in a loop made of optical waveguide material. This decay constant changes as small liquid samples containing absorbing species are introduced into the loop. In this report, it is demonstrated that one can also obtain the optical decay constant using a continuous wave laser beam that is intensity modulated and then coupled into an optical fiber loop. The inherent exponential decay in the fiber loop introduces a phase shift of the light emitted from the loop with respect to the pumping beam. By measuring this phase shift, one can readily determine the concentration of the analyte introduced between the two fiber ends and a model is established to describe the relationship. It is demonstrated that this technique, dubbed phase-shift fiber-loop ring-down spectroscopy (PS-FLRDS), is well suited as an absorption detector for any flow system in which the optical absorption path is limited by the instrument architecture. By measuring the phase angle as a function of concentration of 1,1'-diethyl-4,4'-dicarbocyanine iodide in dimethyl sulfoxide, the detection limit was determined as approximately 6 microM for a 30-40-microm absorption path. A temporal resolution of approximately 100 ms was demonstrated by a rapid displacement of the solutions between the two fiber ends. Proof-of-principle use of the PS-FLRDS detection in capillary flow systems using a commercial four-way microcross established that the alignment of the fiber and the capillary can be made simple and effective, while retaining both a low detection limit and a fast response.

Journal Article↗

Porous polymer monolith assisted electrospray.

Coupling low-flow analytical separation instrumentation such as capillary electrophoresis, capillary electrochromatography, nano-HPLC, and microfluidic-based devices with electrospray ionization mass spectrometry has yielded powerful analytical tools. However, conventional coupling methodologies such as nanospray suffer from limitations including poor conductive coating robustness, constant clogging, complicated fabrication processes, and incompatibility with large flow rate regimes. This study demonstrates that robust nanospray emitters can be fabricated through the formation and utilization of a porous polymer monolith (PPM) at the end of a fused-silica capillary. Stable electrosprays can be produced from capillaries (75-100-microm i.d.) at a variety of flow rates (50-1000 nL/min) without the need to taper the capillaries by etching or pulling. The PPM is photopatterned to be present only near the capillary exit aperture using conditions that generate pore sizes similar to those seen with nanospray tips. The porous nature of the PPM aids in developing a stable electrospray generating a single clearly visible Taylor cone at relatively high flow rates while at low flow rates (<100 nL/min) a mist, presumably from multiple small Taylor cones, develops. The hydrophobic nature of the PPM should limit problems with band broadening associated with droplet spreading at the capillary exit, while the multiple flow paths inherent in the PPM minimize clogging problems associated with conventional nanospray emitters. Total ion current traces for a constant infusion of standard PPG and cytochrome c solutions are very stable with deviations ranging from only 3 to 8%. The PPM-assisted electrospray produces mass spectra with excellent signal-to-noise ratios from only a few femtomoles of material.

Nanotechnology↗

Microchip-based capillary electrochromatography using packed beds.

Integration of a packed column onto a microchip for performance of capillary electrochromatography (CEC) is described. The quartz device incorporated a cross-injector, and a double weir trapping design for formation of 1, 2 and 5 mm long CEC columns. Three fluorescent dyes were baseline-resolved with plate numbers of 330,(330,000 plates/m; height equivalent to a theoretical plate, H = 3.0 microm) for BODIPY 493/503, 360 (360,000 plates/m; H = 2.8 microm) for rhodamine 123 and 244 (244,000 plates/m; H = 4.1 microm) for acridine orange (AO) with 500 V applied on a 1 mm long column. The 2 mm column yielded approximately 1.8 times more theoretical plates than did the 1 mm column, when operated at the same flow rate. Van Deemter plots were obtained for the three column lengths, showing increased plate height for the 5 mm length. A 2 mm column gave peak height and area relative standard deviation (RSD) values of 2.5 and 3.3%, respectively, as averages for the three dyes (n = 15). The RSD for the dye retention times was 1% (n = 6) over one day, and 3% (n = 30) over five days. Indirect fluorescence detection of thiourea and of amino acids was possible using a neutral indicator dye (BODIPY 493/503), with a detection limit of 10 microM for amino acids.

Arginine↗

Surface characterization using chemical force microscopy and the flow performance of modified polydimethylsiloxane for microfluidic device applications.

The widespread interest in micro total analysis systems has resulted in efforts to develop devices in cheaper polymer materials such as polydimethylsiloxane (PDMS) as an alternative to expensive glass and silicon devices. We describe the oxidation of the PDMS surface to form ionizable groups using a discharge from a Tesla coil and subsequent chemical modification to augment electroosmotic flow (EOF) within the microfluidic devices. The flow performance of oxidized, amine-modified and unmodified PDMS materials has been determined and directly compared to conventional glass devices. Exact PDMS replicas of glass substrates were prepared using a novel two step micromolding protocol. Chemical force microscopy has been utilized to monitor and measure the efficacy of surface modification yielding information about the acid/base properties of the modified and unmodified surfaces. Results with different substrate materials correlates well with expected flow modifications as a result of surface modification. Oxidized PDMS devices were found to support faster EOF (twice that of native PDMS) similar to glass while those derivatized with 3-aminopropyl triethoxysilane (APTES) showed slower flow rates compared to native PDMS substrates as a result of masking surface charge. Results demonstrate that the surface of PDMS microdevices can be manipulated to control EOF characteristics using a facile surface derivatization methodology allowing surfaces to be tailored for specific microfluidic applications and characterized with chemical force microscopy.

Dimethylpolysiloxanes↗

An integrated solid-phase extraction system for sub-picomolar detection.

A microchip structure etched on a glass substrate for packed column solid-phase extraction (SPE) and capillary electrochromatography (CEC) is described. A 200 microm long, octadecylsilane (ODS) packed column was secured using two different approaches: solvent lock or polymer entrapment. The former method was utilized for SPE while the latter approach was applied for CEC. In SPE, the ODS packed chamber gave a detection limit of 70 fM for a nonpolar BODIPY (493/503) dye when concentrated for 3 min at an electroosmotic flow rate of 4.14 nL/min, compared to 30 pM for this detector without the SPE step. SPE beds showed reproducible, linear calibration curves (R(2) = 0.9989) between 1 and 100 pM BODIPY at fixed preconcentration times. Breakthrough curves for the 330 pL (ODS-packed) bed indicated a capacity for BODIPY dye of 8.1 x 10(-14) mmol, or 0.25 mmol dye per liter of bed. The ODS-chamber could also be used to analyze dilute amino acid and peptide solutions. In the CEC format, two neutral dyes (BODIPY and acridine orange) were baseline-separated in an isocratic run with a theoretical plate count of 84 (420 000 plates/m) and a reduced plate height of about 1. A labeled peptide was also analyzed by CEC, using the acidic eluent (84% acetonitrile, and 26% aqueous trifluoroacetic acid (0.05%)) preferred for peptide separations on ODS-coated silica particles.

Acridine Orange↗