Comparison of zotarolimus-eluting and sirolimus-eluting stents in patients with native coronary artery disease: a randomized controlled trial.

OBJECTIVES: This trial examined the relative clinical efficacy, angiographic outcomes, and safety of zotarolimus-eluting coronary stents (ZES) with a phosphorylcholine polymer versus sirolimus-eluting stents (SES). BACKGROUND: Whether a cobalt-based alloy stent coated with the novel antiproliferative agent, zotarolimus, and a phosphorylcholine polymer may provide similar angiographic and clinical benefit compared with SES is undetermined. METHODS: A prospective, multicenter, 3:1 randomized trial was conducted to evaluate the safety and efficacy of ZES (n = 323) relative to SES (n = 113) in 436 patients undergoing elective percutaneous revascularization of de novo native coronary lesions with reference vessel diameters between 2.5 mm and 3.5 mm and lesion length > or =14 mm and < or =27 mm. The primary end point was 8-month angiographic in-segment late lumen loss. RESULTS: Angiographic in-segment late lumen loss was significantly higher among patients treated with ZES compared with SES (0.34 +/- 0.44 mm vs. 0.13 +/- 0.32 mm, respectively; p < 0.001). In-hospital major adverse cardiac events were significantly lower among patients treated with ZES (0.6% vs. 3.5%, p = 0.04). In-segment binary angiographic restenosis was also higher in the ZES cohort (11.7% vs. 4.3%, p = 0.04). Total (clinically and non-clinically driven) target lesion revascularization rates at 9 months were 9.8% and 3.5% for the ZES and SES groups, respectively (p = 0.04). However, neither clinically driven target lesion revascularization (6.3% zotarolimus vs. 3.5% sirolimus, p = 0.34) nor target vessel failure (12.0% zotarolimus vs. 11.5% sirolimus, p = 1.0) differed significantly. CONCLUSIONS: Compared with SES, treatment with a phosphorylcholine polymer-based ZES is associated with significantly higher late lumen loss and binary restenosis at 8-month angiographic follow-up. (The Endeavor III CR; http://clinicaltrials.gov/ct/show/NCT00265668?order=1?).

Aged↗

A meta-analysis of randomized controlled trials of intracoronary gamma- and beta-radiation therapy for in-stent restenosis.

We assessed the effectiveness of intracoronary brachytherapy and compared treatment effects for the two radiation sources as well as the performance of the procedure in saphenous vein grafts (SVG) and native coronary arteries. Five randomized controlled trials comparing intracoronary brachytherapy with placebo involving a total of 1310 patients were reviewed for a meta-analysis. Risk differences (RD) for major adverse cardiac events (MACE), target vessel revascularization, target lesion revascularization, and angiographic binary restenosis at 6-12 months were computed, and a meta-regression analysis of MACE was performed. For MACE, the RD was 0.19 (95% confidence interval [CI], 0.09%-0.29%; P value, 0.00); there was significant between-study variance of 0.2395. In univariate meta-regression analyses, diabetes was a significant factor for the between-study variance (P value, 0.000). In multivariate meta-regression analyses adjusted for diabetes and lesion length, neither gamma-radiation source nor SVG was a significant factor for the between-study variance (P value, 0.675 and 0.433, respectively); the adjusted between-study variance was 0.000. Intra-coronary brachytherapy is effective compared with placebo at mid-term follow up. Neither procedure in SVG (gamma radiation) nor difference in radiation source (beta or gamma) in native coronary arteries was a significant factor in brachytherapy effectiveness compared to placebo.

Beta Particles↗

Safety and efficacy of the 2.25-mm sirolimus-eluting Bx Velocity stent in the treatment of patients with de novo native coronary artery lesions: the SIRIUS 2.25 trial.

Smaller reference vessel diameter is a recognized determinant of in-stent restenosis. The SIRIUS 2.25 trial was a prospective, nonrandomized study including 100 patients (mean age 63.4 years; 64% men, 40% with diabetes mellitus) assessing the safety and efficacy of the 2.25-mm sirolimus-eluting Bx Velocity stent in patients with de novo native coronary lesions. Using propensity score matching for gender, diabetes mellitus, left anterior descending artery target vessel, lesion length, and reference vessel diameter, the outcomes were compared with historical control groups (angioplasty and Palmaz-Schatz stent arms from the STRESS/BENESTENT I/II trials and the Bx Velocity bare metal stent arm from the RAVEL and SIRIUS trials having a reference vessel diameter <3 mm). Use of the 2.25-mm sirolimus-eluting Bx Velocity stent was associated with a high rate of procedural success (97%) and a low rate of in-hospital major adverse cardiac events (2%). The primary end point, 6-month in-lesion binary angiographic restenosis, occurred less frequently in patients treated with the 2.25-mm sirolimus-eluting Bx Velocity stent than in each of 3 historical controls (16.9% vs 30.6%, p = 0.12; 36.5%, p <0.001; 45.9%, p <0.001, respectively). This translated into lower rates of 6-month target lesion revascularization in the 2.25-mm sirolimus-eluting Bx Velocity stent group (4.0% vs 15.0% in each of 3 control groups, p = 0.01 to <0.001). By multivariate analysis, in-lesion binary restenosis was predicted by multiple implanted stents (odds ratio 10.4, p = 0.002). Four of 13 patients who developed restenosis (30.8%) had a diffuse pattern of restenosis. In the long lesion tertile (mean lesion length 19.5 mm), the in-lesion binary restenosis rate was 27.6%. In conclusion, use of the 2.25-mm sirolimus-eluting Bx Velocity stent was safe and provided favorable 6-month clinical outcomes. Use of multiple stents (in longer lesions) was an independent predictor of in-lesion restenosis.

Angioplasty, Balloon, Coronary↗

Randomized, double-blind, multicenter study of the Endeavor zotarolimus-eluting phosphorylcholine-encapsulated stent for treatment of native coronary artery lesions: clinical and angiographic results of the ENDEAVOR II trial.

BACKGROUND: The use of the Endeavor stent might reduce restenosis and stent thrombosis at 9 months. METHODS AND RESULTS: Patients (n = 1197) treated for single coronary artery stenosis were enrolled in a prospective, randomized, double-blind study and randomly assigned to receive the Endeavor zotarolimus-eluting phosphorylcholine polymer-coated stent (n = 598) or the same bare metal stent but without the drug or the polymer coating (n = 599). The 2 groups were well matched in baseline characteristics. Diabetes was present in 20.1% of patients; the mean reference vessel diameter was 2.75 mm; and the mean lesion length was 14.2 mm. The primary end point of target vessel failure at 9 months was reduced from 15.1% with the bare metal stent to 7.9% with the Endeavor (P = 0.0001), and the rate of major adverse cardiac events was reduced from 14.4% with the bare metal stent to 7.3% with the Endeavor (P = 0.0001). Target lesion revascularization was 4.6% with Endeavor compared with 11.8% with the bare metal stent (P = 0.0001). The rate of stent thrombosis was 0.5% with the Endeavor, which was not significantly different from 1.2% with the bare metal stent. In 531 patients submitted to angiographic follow-up, late loss was reduced from 1.03 +/- 0.58 to 0.61 +/- 0.46 (P < 0.001) in stent and from 0.72 +/- 0.61 to 0.36 +/- 0.46 (P < 0.001) in segment. The rate of in-segment restenosis was reduced from 35.0% to 13.2% with Endeavor (P < 0.0001). There was no excessive edge stenosis, aneurysm formation, or late acquired malapposition by intravascular ultrasound imaging. Differences in clinical outcome were maintained at 12 and 24 months (P < 0.0001). CONCLUSIONS: Compared with bare metal stents, the Endeavor stent is safe and reduces the rates of clinical and angiographic restenosis at 9, 12, and 24 months.

Aged↗

Periprocedural and late consequences of overlapping Cypher sirolimus-eluting stents: pooled analysis of five clinical trials.

OBJECTIVES: The purpose of this research was to determine the relative safety and efficacy of multiple (> or =2) overlapping Cypher sirolimus-eluting stents (SES) (Johnson & Johnson, New Brunswick, New Jersey). BACKGROUND: Overlapping coronary stents are common. The periprocedural and late clinical and angiographic consequences of overlapped coronary stents are not clearly defined, particularly for drug-eluting stents. METHODS: All patients enrolled into five clinical trials of the SES were analyzed. Three of these trials were prospective randomized comparisons of the SES to the bare-metal stent (BMS), and two were prospective non-randomized trials of SES-treated patients with historical controls. All clinical and angiographic outcomes in overlap-stent-treated patients were compared by stent type and with single-stent-treated patients for the same stent device. RESULTS: In all, 575 patients with stent overlap (337 SES, 238 BMS) and 1,162 patients with single stents (697 SES, 465 BMS) were analyzed. Stent overlap was associated with a greater late lumen loss in stent and more frequent angiographic restenosis regardless of stent type. Among overlap-stent-treated patients, the SES provided similar magnitude of restenosis benefit as observed for single-stent-treated patients. Overlapped SES was not associated with an increase in myocardial infarction. CONCLUSIONS: The strategy of SES overlap, when required, is both safe and efficacious in reducing restenosis with no increase in the incidence of myocardial infarction or major adverse cardiovascular events, when compared with a bare metal coronary stent prosthesis.

Angioplasty, Balloon, Coronary↗

Sirolimus-eluting stents at two years: a pooled analysis of SIRIUS, E-SIRIUS, and C-SIRIUS with emphasis on late revascularizations and stent thromboses.

Prospective follow-up at 2 years was obtained for 98.7% of the pooled 1,510 patients enrolled in SIRIUS, E-SIRIUS and C-SIRIUS, 3 randomized controlled trials that compared sirolimus-eluting stents (SESs) with bare metal stents (BMSs) to treat long stenoses in small coronary arteries. By 720 days, clinically driven target lesion revascularizations were performed in 5.7% of patients with SESs versus 22.6% of patients with BMSs (risk ratio 0.25, 95% confidence interval 0.18 to 0.35, p <0.001). Of these, late target lesion revascularization (from 271 to 720 days) was performed in 12 patients who received SESs (1.6%) compared with 37 patients with BMSs (4.9%) (risk ratio 0.32, 0.17 to 0.61, p <0.001). Stent thromboses occurred in 7 of 758 patients with SESs (0.9%, 4 subacute, 3 late) and 5 of 752 patients with BMSs (0.7%, 1 subacute, 4 late) (risk ratio 1.39, 95% confidence interval 0.44 to 4.36, p = 0.774). The Kaplan-Meier estimate of freedom from major cardiac adverse events was 89.3% for patients with SESs versus 73.4% for patients with BMSs (p <0.001). This analysis demonstrates the sustained efficacy and safety of sirolimus-eluting stents at 2 years, characterized by a persistent significant benefit in freedom from repeat revascularization compared with BMSs and a low risk of late stent thrombosis, not different from BMSs.

Coronary Artery Disease↗

The fate of patients with clinical recurrence after sirolimus-eluting stent implantation (a two-year follow-up analysis from the SIRIUS trial).

Although clinical outcomes after sirolimus-eluting stents (SESs) have been previously described ("primary" success rates), the fate of patients whose SES implantation fail and who require ischemia-driven target lesion revascularization is poorly understood. The SIRIUS trial is a prospective, randomized, clinical trial that includes 533 evaluable patients with SESs. Twenty-two of these patients had adjudicated ischemia-driven target lesion revascularization (4.1%) within the first year of follow-up and comprised the study population of this analysis. Of these patients, 11 (50%) had diabetes, and restenotic lesions were focal and located at the proximal stent edge in 91% and 73% of patients, respectively. Restenosis was treated with bare metal stent implantation, balloon dilatation, or intravascular brachytherapy in 82%, 13.5%, and 4.5% of patients, respectively. At 1-year follow-up after the first recurrence (2-year follow-up after the index procedure), only 5 of these patients (23%) required a second repeat revascularization procedure. Risk factors for a second recurrence after treatment of SES restenosis were female gender, long lesions that required long stents at the index procedure, and an early first recurrence. In conclusion, SES failure treated with traditional percutaneous coronary intervention yielded good outcome at 1-year follow-up (secondary failure rate only 23%), perhaps due to the focal nature of the SES restenotic lesion. Future studies should evaluate other methods, including drug-eluting stents, to further optimize the outcome of treatment of SES failures.

Blood Vessel Prosthesis Implantation↗

Two-year outcomes after sirolimus-eluting stent implantation: results from the Sirolimus-Eluting Stent in de Novo Native Coronary Lesions (SIRIUS) trial.

OBJECTIVES: The purpose of this study was to examine the two-year clinical outcomes in patients enrolled in the Sirolimus-Eluting Stent in De Novo Native Coronary Lesions (SIRIUS) study. BACKGROUND: The SIRIUS study was a double-blinded randomized study which demonstrated that sirolimus-eluting stents (SES) significantly improved angiographic results (at 8 months) and clinical outcomes (at 9 and 12 months) compared with bare-metal stents (BMS). METHODS: Patients with de novo native coronary artery lesions randomized to either SES (533 patients) or control BMS (525 patients) were followed for two years. RESULTS: Between one and two years, there were infrequent additional clinical events that were equally distributed between the sirolimus and control groups. After two years, target lesion revascularization was 5.8% and 21.3% in SES and control patients, respectively (p < 0.001), and major adverse cardiovascular events and target vessel failure rates were 10.1% versus 24.4% and 12.0% versus 26.7%, respectively (p < 0.0001 for both). There were no differences in death, myocardial infarction, and stent thrombosis between the two groups. CONCLUSIONS: Clinical outcomes two years after implantation of SES continue to demonstrate significant reduction in the need for repeat target lesion (and vessel) revascularization compared with BMS without evidence for either disproportionate late restenosis or late stent thrombosis.

Coronary Angiography↗

Sirolimus-eluting stents vs vascular brachytherapy for in-stent restenosis within bare-metal stents: the SISR randomized trial.

CONTEXT: Although vascular brachytherapy is the only approved therapy for restenosis following bare-metal stent implantation, drug-eluting stents are now being used. Data on the relative merits of each are limited. OBJECTIVE: To determine the safety and efficacy of the sirolimus-eluting stent compared with vascular brachytherapy for the treatment of patients with restenosis within a bare-metal stent. DESIGN, SETTING, AND PATIENTS: Prospective, multicenter, randomized trial of 384 patients with in-stent restenosis who were enrolled between February 2003 and July 2004 at 26 academic and community medical centers. Data presented represent all follow-up as of June 30, 2005. INTERVENTIONS: Vascular brachytherapy (n = 125) or the sirolimus-eluting stent (n = 259). MAIN OUTCOME MEASURE: Target vessel failure (cardiac death, myocardial infarction, or target vessel revascularization) at 9 months postprocedure. RESULTS: Baseline patient characteristics were well matched. Lesion length was similar between vascular brachytherapy and sirolimus-eluting stent patients (mean [SD], 16.76 [8.55] mm vs 17.22 [7.97] mm, respectively; P = .61). Procedural success was 99.2% (124/125) in the vascular brachytherapy group and 97.3% (250/257) in the sirolimus-eluting stent group (P = .28). The rate of target vessel failure was 21.6% (27/125) with vascular brachytherapy and 12.4% (32/259) with the sirolimus-eluting stent (relative risk [RR], 1.7; 95% confidence interval [CI], 1.1-2.8; P = .02). Target lesion revascularization was required in 19.2% (24/125) of the vascular brachytherapy group and 8.5% (22/259) of the sirolimus-eluting stent group (RR, 2.3 [95% CI, 1.3-3.9]; P = .004). At follow-up angiography, the rate of binary angiographic restenosis for the analysis segment was 29.5% (31/105) for the vascular brachytherapy group and 19.8% (45/227) for the sirolimus-eluting stent group (RR, 1.5 [95% CI, 1.0-2.2]; P = .07). Compared with the vascular brachytherapy group, minimal lumen diameter was larger in the sirolimus-eluting stent group at 6-month follow-up (mean [SD], 1.52 [0.63] mm vs 1.80 [0.63] mm; P<.001), reflecting greater net lumen gain in the analysis segment (0.68 [0.60] vs 1.0 [0.61] mm; P<.001) due to stenting and no edge restenosis. CONCLUSION: Sirolimus-eluting stents result in superior clinical and angiographic outcomes compared with vascular brachytherapy for the treatment of restenosis within a bare-metal stent. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT00231257.

Aged↗

Zotarolimus (ABT-578) eluting stents.

Drug-eluting stents have revolutionized the field of interventional cardiology and have provided a significant innovation for preventing coronary artery restenosis. Polymer coatings that deliver anti-proliferative drugs to the vessel wall are key components of these revolutionary medical devices. This article focuses on the development of stents which elute the potent anti-proliferative agent, zotarolimus, from a synthetic phosphorylcholine-based polymer known for its biocompatible profile. Zotarolimus is the first drug developed specifically for local delivery from stents for the prevention of restenosis and has been tested extensively to support this indication. Clinical experience with the PC polymer is also extensive, since more than 120,000 patients have been implanted to date with stents containing this non-thrombogenic coating. This review provides background on pre-clinical studies with zotarolimus, on the development of the biocompatible PC polymer and on the clinical trials conducted using two stent platforms which deliver this drug to patients with coronary artery disease.

Coronary Restenosis↗

Platelet glycoprotein IIb/IIIa receptor inhibition as adjunctive treatment during saphenous vein graft stenting: differential effects after randomization to occlusion or filter-based embolic protection.

AIMS: Although embolic protection devices reduce complications during saphenous vein graft (SVG) stenting, adverse events still occur in approximately 10% of patients. IIb/IIIa antagonists have not been proven effective during SVG intervention. We hypothesized that adjunctive use of these agents might enhance the efficacy of embolic protection devices. METHODS AND RESULTS: In the prospective, multicentre FilterWire EX Randomized Evaluation trial, 651 patients undergoing SVG stenting were randomized to either filter-based FilterWire EX or balloon occlusion/aspiration GuardWire embolic protection devices. IIb/IIIa inhibitor use was at the discretion of the investigator, with randomization stratified by intended use. Patients pre-selected for IIb/IIIa inhibitor use (n = 345) had higher baseline risk, with increased 30-day major adverse cardiac events (MACE, 13.0 vs. 8.0%, P = 0.03). GuardWire assigned patients treated with IIb/IIIa inhibitors had higher 30-day MACE compared with those not treated with IIb/IIIa inhibitors (16.0 vs. 6.3%, P = 0.007). In contrast, MACE in high-risk FilterWire patients treated with IIb/IIIa inhibitors were similar to their lower risk, untreated counterparts (9.9 vs. 9.5%, P = 0.89). Multivariable analysis detected a borderline significant (P = 0.056) interaction for lower MACE between FilterWire and IIb/IIIa inhibitor use. Adjustment by the propensity to use IIb/IIIa inhibitors resulted in a significant (P = 0.023) interaction for lower MACE rates. IIb/IIIa inhibition in conjunction with FilterWire was associated with less abrupt closure, no reflow, or distal embolization. CONCLUSION: IIb/IIIa antagonists may improve procedural outcome during SVG stenting in high risk patients, utilizing filter-based embolic protection devices.

Aged↗

Six-month outcomes after percutaneous intervention for lesions in aortocoronary saphenous vein grafts using distal protection devices: results from the FIRE trial.

BACKGROUND: The filter-based FilterWire EX (Boston Scientific, Natick, MA) embolic protection system and the GuardWire (Medtronic, Santa Rosa, CA) balloon occlusion and aspiration device have been previously shown to reduce periprocedural complication rates of percutaneous coronary intervention for saphenous vein graft (SVG) disease and are considered the standard of care in this setting. The late clinical course after treatment with these devices has not been reported. METHODS: In the FIRE trial, 651 patients undergoing SVG intervention were randomized to either the FilterWire EX or GuardWire. Six-month rates of the primary end point (composite major adverse cardiac events [MACE]) and its components (death, myocardial infarction [MI], or target vessel revascularization) were studied. RESULTS: MACE at 30 days occurred in 9.9% of patients randomized to the FilterWire EX compared with 11.6% with the GuardWire, P = .53. By 6 months, MACE had increased to 19.3% and 21.9% in FilterWire EX and GuardWire groups, respectively, (relative risk 0.88, 95% CI 0.65-1.19; P = .44). All-cause 6-month mortality in the entire population was 3.5% (3.0% with FilterWire EX vs 4.1% with GuardWire, P = .53, with all deaths occurring after hospital discharge). MI occurred in 12.0% of patients at 6 months (12.1% vs 11.9% with the FilterWire EX and GuardWire, respectively, P = .99), and target vessel revascularization was required in 9.1% (8.2% vs 10.0%, respectively, P = .42). CONCLUSIONS: SVG intervention with the FilterWire EX and GuardWire distal protection devices resulted in similar outcomes at 6 months, although the clinical course after hospital discharge was not benign, with significant rates of death, MI, and repeat intervention.

Aged↗

The use of invasive cardiac procedures after acute myocardial infarction in long-term dialysis patients.

BACKGROUND: Dialysis patients have an excessive risk of cardiovascular death after myocardial infarction (MI). Underutilization of cardiac therapies may partially explain this risk, but whether patients on maintenance dialysis have differential rates of coronary angiography or revascularization during admission for MI compared with patients not on dialysis and whether these differences are explained by the presence of comorbid illness were uncertain. METHODS: We analyzed 154,692 patients with a primary diagnosis of MI in the 2001 National Inpatient Sample, and we compared procedure use in patients on long-term dialysis, patients with non-dialysis-dependent chronic kidney disease (CKD), or normal renal function. RESULTS: Dialysis patients and patients with dialysis-independent CKD were significantly less likely to undergo coronary angiography than patients with normal renal function (39% and 34% vs 56%). They were also less likely to undergo coronary revascularization (19% and 23% vs 41%) or to have a coronary intervention after diagnostic angiography (46% and 62% vs 70%). After adjustment, these differences remained, with a lower likelihood of angiography (42% and 45% vs 56%), revascularization (22% and 31% vs 41%), or coronary intervention after diagnostic angiography (52% and 66% vs 70%). CONCLUSIONS: Despite a high mortality rate after MI, patients on dialysis are markedly less likely than patients with dialysis-independent CKD or normal renal function to undergo diagnostic angiography or coronary revascularization after admission for MI. Additional studies to determine how these disparities are related to mortality are warranted.

Aged↗

Remodeling characteristics of minimally diseased coronary arteries are consistent along the length of the artery.

Using a method that creates anatomically correct, 3-dimensional arterial reconstructions, 55 minimally diseased coronary arteries from 40 patients were studied. Homogenous remodeling characteristics along the entire length of the artery were observed in 48 arteries (87%). In the aggregate, arteries exhibited compensatory expansive remodeling. Individually, the full spectrum of compensatory expansive remodeling (60%), excessive expansive remodeling (21%), and constrictive remodeling (19%) was observed across arteries. Each artery was consistent in its remodeling characteristics from proximal to distal portions of the artery, and the remodeling pattern of each artery was independent within the same patient.

Adult↗

Humanitarian Use Devices/Humanitarian Device Exemptions in cardiovascular medicine.

The Second Dartmouth Device Development Symposium held in October 2004 brought together leaders from the medical device community, including clinical investigators, senior representatives from the US Food and Drug Administration, large and small device manufacturers, and representatives from the financial community to examine difficult issues confronting device development. The role of the Humanitarian Use Device/Humanitarian Device Exemption (HUD/HDE) pathway in the development of new cardiovascular devices was discussed in this forum. The HUD/HDE pathway was created by Congress to facilitate the availability of medical devices for "orphan" indications, ie, those affecting <4000 individuals within the United States each year. The HUD/HDE pathway streamlines the approval process and permits less well-characterized devices to enter the market. HDE approval focuses primarily on issues of safety and scientific soundness and does not require demonstration of efficacy. In the 7 years since the first device was approved in 1997, a total of 35 HDEs have been granted (23 devices, 6 diagnostic tests). As the costs to gain regulatory approval for commonly used devices increase, companies often seek alternative ways to gain market access, including the HUD/HDE pathway. For a given device, there may be multiple legitimate and distinct indications, including indications that meet the HUD criteria. Companies must choose how and when to pursue each of these indications. The consensus of symposium participants was for the HUD/HDE pathway to be reserved for true orphan indications and not be viewed strategically as part of the clinical development plan to access a large market.

Altruism↗

Robustness of late lumen loss in discriminating drug-eluting stents across variable observational and randomized trials.

BACKGROUND: Binary angiographic and clinical restenosis rates can vary widely between clinical studies, even for the same stent, influenced heavily by case-mix covariates that differ among observational and randomized trials intended to assess a given stent system. We hypothesized that mean in-stent late loss might be a more stable estimator of restenosis propensity across such studies. METHODS AND RESULTS: In 46 trials of drug-eluting and bare-metal stenting, increasing mean late loss was associated with higher target lesion revascularization (TLR) rates (P<0.001). When the class of bare-metal stents was compared with the class of effective drug-eluting stents, late loss was more discriminating than TLR as measured by the high intraclass correlation coefficient (rho) (late loss, rho=0.71 versus TLR, rho=0.22; 95% CI of difference=0.33, 0.65). When the individual drug-eluting stents and bare-metal stents were compared, late loss was a better discriminator than TLR (0.68 versus 0.19; 95% CI of difference=0.24, 0.60). Greater adjustments of study covariates are needed to stabilize assessments of TLR compared with late loss because of greater influence of reference vessel diameter on TLR than on in-stent late loss. Optimization of late loss with the use of a novel method of standardization according to diabetes prevalence and mean lesion length resulted in minor adjustments in late loss (<0.08 mm for 90% of reported trials) and an ordered array of mean late loss values for the stent systems studied. CONCLUSIONS: Late loss is more reliable than restenosis rates for discriminating restenosis propensity between new drug-eluting stent platforms across studies and might be the optimum end point for evaluating drug-eluting stents in early, nonrandomized studies.

Blood Vessel Prosthesis Implantation↗

A blinded, randomized, placebo-controlled trial of percutaneous laser myocardial revascularization to improve angina symptoms in patients with severe coronary disease.

OBJECTIVES: This study was a randomized, patient- and evaluator-blinded, placebo-controlled trial in patients treated using percutaneous myocardial laser revascularization. BACKGROUND: Previous studies using similar therapies have been confounded by placebo bias. METHODS: A total of 298 patients with severe angina were randomly assigned to receive low-dose or high-dose myocardial laser channels or no laser channels, blinded as a sham procedure. The primary end point was the change in exercise duration from baseline examination to six months. RESULTS: The incidence of 30-day death, stroke, myocardial infarction, coronary revascularization, or left ventricular perforation occurred in two patients in the placebo, eight patients in the low-dose, and four patients in the high-dose groups (p = 0.12); 30-day myocardial infarction incidence was higher in patients receiving either low-dose or high-dose laser (nine patients) compared with placebo (no patients, p = 0.03). At six months, there were no differences in the change in exercise duration between those receiving a sham (28.0 s, n = 100), low-dose laser (33.2 s, n = 98), or high-dose laser (28.0 s, n = 98, p = 0.94) procedure. There were also no differences in the proportion of patients improving to better than Canadian Cardiovascular Society class III angina symptoms at six months. The follow-up visual summed stress single-photon-emission computed tomography scores were not significantly different from baseline in any group and were no different between groups. The modest improvement in angina symptoms assessed by the Seattle Angina Questionnaire also was not statistically different among the arms. CONCLUSIONS: Treatment with percutaneous myocardial laser revascularization provides no benefit beyond that of a similar sham procedure in patients blinded to their treatment status.

Angina Pectoris↗