PubMed Health⌕ Search

Biomedical subjects

Richard G Smith

Publications and source records attributed to Richard G Smith.

10 recordsLinked to original sources

Pediatric bridge to heart transplantation: application of the Berlin Heart, Medos and Thoratec ventricular assist devices.

BACKGROUND: Bridge to transplantation (BTT) is an accepted option when a donor heart is not available. Extensive clinical study has been done with BTT in the adult population, but comparatively fewer data are available in the pediatric population with regard to pulsatile devices. METHODS: Ten pediatric patients are presented, all of whom underwent BTT or recovery with pneumatic paracorporeal systems. The Berlin Heart bi-ventricular assist device (BVAD) was utilized in 1 patient, the Medos VAD in 4 patients (1 left ventricular assist device [LVAD], 3 BVADs) and the Thoratec VAD in 5 patients (3 BVADs, 2 LVADs). The pediatric population consisted of 3 females and 7 males. Mean age of the population was 7.4 years, weight 25 kg and body surface area (BSA) 0.88 m(2). Etiology for heart failure consisted of 4 viral, 3 congenital and 3 idiopathic cardiomyopathies. Before implant, all patients had evidence of progressive cardiac failure despite inotropic support, and 2 patients had been on extracorporeal membrane oxygenation (ECMO). Mean duration on the device was 34.3 days (8 to 107 days). RESULTS: Two patients suffered stroke and recovered without sequelae. Two patients died of ischemic stroke and 1 of sepsis. Seven patients survived (6 transplanted and 1 weaned) for a survival rate of 70% compared with survival for ECMO as BTT, which was 40% to 50%. All survivors had complications related to bleeding, thromboembolic events and infections. CONCLUSIONS: The Thoratec VAD can be placed in small patients with large hearts that can accommodate the available cannulas. The Berlin Heart and the Medos VAD have a selection of ventricles with small stroke volumes. All 3 systems can be used successfully in the pediatric population as BTT with better survival than with ECMO.

Adolescent↗

CardioWest total artificial heart in a moribund adolescent with left ventricular thrombi.

Bridge to transplant is a well-known strategy to enable patients with congestive heart failure to live until transplant. A 15-year-old boy with Beckers' muscular dystrophy and cardiomyopathy was accepted for heart transplantation. He suffered a cardiac arrest and was placed on extracorporeal membrane oxygenator. A paracorporeal biventricular assist device and a total artificial heart were considered for bridge to transplant. A CardioWest total artificial heart was chosen because of the patient's size. Multiple left ventricular thrombi were identified at the time of the ventriculectomy. The patient did well with the total artificial heart was transplanted and discharged home. The unknown presence of significant left ventricular thrombi raises the question of outcome with a paracorporeal ventricular assist device.

Adolescent↗

Cardiac replacement with a total artificial heart as a bridge to transplantation.

BACKGROUND: The CardioWest Total Artificial Heart orthotopically replaces both native cardiac ventricles and all cardiac valves, thus eliminating problems commonly seen in the bridge to transplantation with left ventricular and biventricular assist devices, such as right heart failure, valvular regurgitation, cardiac arrhythmias, ventricular clots, intraventricular communications, and low blood flows. METHODS: We conducted a nonrandomized, prospective study in five centers with the use of historical controls. The purpose was to assess the safety and efficacy of the CardioWest Total Artificial Heart in transplant-eligible patients at risk for imminent death from irreversible biventricular cardiac failure. The primary end points included the rates of survival to heart transplantation and of survival after transplantation. RESULTS: Eighty-one patients received the artificial-heart device. The rate of survival to transplantation was 79 percent (95 percent confidence interval, 68 to 87 percent). Of the 35 control patients who met the same entry criteria but did not receive the artificial heart, 46 percent survived to transplantation (P<0.001). Overall, the one-year survival rate among the patients who received the artificial heart was 70 percent, as compared with 31 percent among the controls (P<0.001). One-year and five-year survival rates after transplantation among patients who had received a total artificial heart as a bridge to transplantation were 86 and 64 percent. CONCLUSIONS: Implantation of the total artificial heart improved the rate of survival to cardiac transplantation and survival after transplantation. This device prevents death in critically ill patients who have irreversible biventricular failure and are candidates for cardiac transplantation.

Critical Illness↗

Total artificial heart bridge to transplantation: a 9-year experience with 62 patients.

BACKGROUND: The SynCardia CardioWest total artificial heart (CardioWest TAH) is a biventricular, orthotopic, pneumatic, pulsatile blood pump driven by an external console. For each ventricle, the length of the blood-flow path is shorter and the inflow and outflow valves are larger than in any other bridge-to-transplant device, resulting in greater blood flow at smaller pre-load. Such a device should be optimal for bridging transplant candidates who have biventricular failure and for whom all other therapies have failed. METHODS: From January 1, 1993, to April 1, 2002, we prospectively studied 62 consecutive CardioWest TAH implant recipients to document safety and efficacy in bridge to transplantation. We used multisystem monitoring and multidrug therapy for anti-coagulation in 58 patients starting September 1, 1994. RESULTS: Before implantation, patients were critically ill with biventricular heart failure. Mortality in this group from the time of implantation until transplantation was 23%. Causes of death during device support included multi-organ failure (6), sepsis (3), and valve entrapment (2). Forty-eight patients underwent transplantation (77%). Forty-two survived to hospital discharge (68% of the total, 88% of those undergoing transplantation). Adverse events included bleeding (20%), device malfunction (5%), fit complications (3%), mediastinal infections (5%), visceral embolus (1.6%), and stroke during support (1.6%). The linearized stroke rate was 0.068 events per patient-year. CONCLUSIONS: Sixty-eight percent of critically ill transplant candidates for whom medical therapy failed were bridged to transplantation with the CardioWest TAH and survived long-term. Most deaths that occurred during device support were related to pre-implant problems. Infection and stroke were rare events. Therefore, we recommend the CardioWest TAH as the biventricular bridge-to-transplant device of choice.

Adolescent↗

Total artificial hearts: bridge to transplantation.

The CardioWest TAH was created and initially tested at the same time as the Thoratec, Novacor, and HeartMate devices. It was designed as a permanent artificial heart and was the first-ever mechanical circulatory device to be used as destination therapy. Twenty years have passed since that early experience. Pneumatic technology is still current and being developed as in existing or new implantable Thoratec VADs the pneumatic HeartMate, and the Abiomed BVS 5000 pumps. Portable pneumatic drivers have been available since 1982, and in recent times have allowed discharge to home of substantial numbers of patients, thus reducing the length of hospital stays and making mechanical device support less expensive to society and more tolerable to patients. Within months, a portable driver for the CardioWest will be available. The documented benefits of the CardioWest TAH include rescue of: critically ill patients with advanced heart failure; patients with biventricular failure especially those with significant right heart failure, elevated pulmonary vascular resistance, or pulmonary edema; patients with renal or hepatic failure secondary to low cardiac output; patients with massive myocardial damage such as those with post-\infarction VSD or irreversible cardiac graft rejection; patients with mechanical valves or native valve disease; and patients with intractable arrhythmias and heart failure. High device outputs with restoration of normal filling pressures result in high perfusion pressures that have led to dramatic recoveries, convalescence, and return to levels of activity compatible with normal life. The average device output with the CardioWest TAH is higher than any other approved or investigational device. The reason for this resides in design simplicity this device has the shortest and largest inflow pathway. Stroke, in the authors' own series, is rare with a linearized rate of 0.068 events per patient year. If the experiences of La Pitie and the University of Arizona are combined, there has been one stroke in 25 patient years (0.04 events/patient year). Serious infections have been rare (12% of patients). No clinical mediastinitis has occurred. Drivelines have healed in tightly and never caused an "ascending" infection. There has not been a case of device endocarditis. Using a broad definition of bleeding, including takeback reoperation for bleeding, bleeding more than 8 units in the first postoperative 24 hours or 5 units over any other 48-hour period, a 25% to 36% incidence has been documented. No cases of fatal exsanguination have resulted, as there have been with the HeartMate. The incidence of bleeding as an adverse event is about 17% lower than the rate reported for the HeartMate VE LVAD, and it is about the same as that reported for Novacor and for Thoratec. Implantation of this device is relatively easy and often done (with attending help) by the authors' residents. If one follows the guidelines for fitting the device, and takes the recommended advice for implantation, hemostasis is excellent and restoration of immediate cardiac function with high flows is nearly automatic. Use of a neopericardium of 0.1 mm EPTFE at the time of implantation assures atraumatic and relatively quick re-entry for transplantation and prevents the normal inflammatory mediastinal reaction that might be desirable in a destination application. In selected patients the CardioWest TAH is the device of choice for bridge to transplantation. When a portable driver becomes available, out of hospital management of CardioWest TAH patients will be feasible and consideration of use of this device for longer term applications, (e.g., "destination therapy,") will be reasonable. A wearable driver, even smaller than a portable, will improve quality of life and expand the patient population that may be therapeutically served with this system. In short, the CardioWest TAH has come nearly full circle. It was first used as a destination device. It has since been used as a bridge to transplantation in nearly 200 patients as the Jarvik-7/Symbion TAH and, since 1993, in over 225 patients as CardioWest. The results have improved with time. Thromboembolism and infection rates have been competitive with currently available devices. Device reliability and durability have been excellent. Survival rates have been very high in a group of perhaps the sickest patients to be supported with any pulsatile device. Pneumatic technology has improved with portability and miniaturization, and there is reason to believe that it will become even better. Application of modern manufacturing techniques to this very simple device raises the possibility of significant manufacturing cost reduction, in an era of prohibitive cost for other devices. All of this establishes the CardioWest as a valuable device for any program that is seriously interested in end-stage heart disease and a likely device for permanent use in appropriately selected patients.

Anticoagulants↗

Dynamic changes in reinforcer effectiveness: theoretical, methodological, and practical implications for applied research.

Reinforcers lose their effectiveness when they are presented repeatedly. Traditionally, this loss of effectiveness has been labeled satiation. However, recent evidence suggests that habituation provides a more accurate and useful description. The characteristics of behavior undergoing satiation differ for different stimuli (e.g., food, water), and these characteristics have not been identified for the noningestive reinforcers often used by applied behavior analysts (e.g., praise, attention). As a result, the term satiation provides little guidance for either maintaining or reducing the effectiveness of reinforcers. In contrast, the characteristics of behavior undergoing habituation are well known and are relatively general across species and stimuli. These characteristics provide specific and novel guidance about how to maintain or reduce the effectiveness of a reinforcer. In addition, habituation may lead to a better understanding of several puzzling phenomena in the conditioning literature (e.g., extinction, behavioral contrast), and it may provide a more precise and accurate description of the dynamics of many different types of behavior.

Animals↗

A multiple-schedule evaluation of immediate and subsequent effects of fixed-time food presentation on automatically maintained mouthing.

The purpose of this study was to evaluate the immediate and subsequent effects of fixed-time (FT) food presentations on mouthing. The effects of FT food presentations were analyzed within a three-component multiple schedule in which baseline conditions were implemented during the first and third components and treatment conditions were implemented during the second component. Results indicated that FT food reduced mouthing and that levels of mouthing during post-FT components were reliably lower than pre-FT components. Behavioral mechanisms responsible for treatment effects are discussed.

Behavior Therapy↗

Purification of anti-MUC1 antibodies by peptide mimotope affinity chromatography using peptides derived from a polyvalent phage display library.

A polyvalent, lytic phage display system (T7Select415-1b) displaying a random peptide library has been investigated for its ability to discover novel mimotopes reactive with the therapeutic monoclonal antibody C595. Sequence analysis of enriched phage lead to the identification of a predominant sequence RNREAPRGKICS, and two other consensus sequences RXXP and RXP. The novel synthetic peptide RNREAPRGKICS was linked to beaded agarose and the performance as a mimotope affinity chromatography matrix evaluated. Antibody purified using the novel matrix was found to be of higher specific reactivity than antibody purified using the conventional epitope matrix (peptide APDTRPAPG). The RNREAPRGKICS peptide binding to C595 demonstrated a higher equilibrium association constant (K(A)=0.75 x 10(6)) than the epitope peptide (K(A)=0.16 x 10(6)). Circular dichroism showed that the novel peptide had a more highly ordered structure at 4 degrees C and room temperature, than the epitope peptide.

Amino Acid Sequence↗

Identification of environmental determinants of behavior disorders through functional analysis of precursor behaviors.

Experimental analysis procedures have been shown to be effective means for identifying the environmental determinants of problem behaviors. A potential limitation of these procedures is that it is necessary to produce and document patterns in the occurrence of the problem behavior during the assessment. In the case of severe behavior disorders, this may place the participant or therapist at such risk as to preclude the analysis. The current study arranged experimental analysis contingencies for precursor behaviors that had been observed to reliably precede the occurrence of problem behaviors targeted for reduction. For each of the 4 participants, it was possible to infer the maintaining variables for problem behaviors based on the outcomes of precursor analysis. These results suggest that the current procedures represent a promising alternative method for reducing risk during functional analysis of problem behaviors.

Adult↗

Availability of dental appointments for young children in King County, Washington: implications for access to care.

PURPOSE: The purpose of this study was to determine the proportion of dental offices in King County willing to provide a new appointment to young children and young children on Medicaid. METHODS: A simulated parent phone call was made to 508 randomly chosen dental offices in King County. Of these, 291 offices provided preventive dental care to children. Data were collected on: (1) youngest age seen (options ranged from less than 1 to older than 5 years); (2) whether Medicaid was accepted; and (3) time to first available appointment. RESULTS: In King County, more than 99% of dental offices providing care to children would see new patients 5 years of age or older, but only 15% of these offices would accept 5-year-olds on Medicaid. Nine percent of dental offices accepted patients younger than 1 for a new preventive visit, but just 3% accepted Medicaid-insured children in this age group. CONCLUSIONS: Adhering to recommendations for early initiation of dental care is difficult, given the limited availability of dental appointments for young and Medicaid-insured children.

Appointments and Schedules↗