PubMed Health⌕ Search

Biomedical subjects

Richard Henthorn

Publications and source records attributed to Richard Henthorn.

2 recordsLinked to original sources

Azimilide decreases recurrent ventricular tachyarrhythmias in patients with implantable cardioverter defibrillators.

OBJECTIVES: This study evaluated the effects of azimilide dihydrochloride (AZ) on anti-tachycardia pacing (ATP) and shock-terminated events in patients with implantable cardioverter defibrillators (ICDs). BACKGROUND: Animal studies have shown the effectiveness of AZ for therapy of supraventricular and ventricular tachycardia (VT). Azimilide dihydrochloride was investigated as adjunctive treatment for reducing the frequency of VT and, thus, the need for ICD therapies, including ATP and cardioversion/defibrillation (ICD shocks) in patients with inducible monomorphic VT. METHODS: A total of 172 patients were randomized to daily treatment with placebo, 35 mg, 75 mg, or 125 mg of oral AZ in this dose-ranging pilot study of patients with ICDs. The majority of patients had a history of documented remote myocardial infarction and congestive heart failure New York Heart Association class II or III. RESULTS: The frequency of appropriate shocks and ATP were significantly decreased among AZ-treated patients compared with placebo patients. The incidence of ICD therapies per patient-year among the placebo group was 36, and it was 10, 12, and 9 among 35 mg, 75 mg, and 125 mg AZ patients, respectively (hazard ratio = 0.31, p = 0.0001). Azimilide dihydrochloride was generally well tolerated and did not affect left ventricular ejection fraction or minimal energy requirements for defibrillation or pacing. CONCLUSIONS: Azimilide dihydrochloride may be a safe and effective drug for reducing the frequency of VT and ventricular fibrillation in patients with implanted ICDs.

Aged↗

Development of the implanted devices adjustment scale.

Advances in microelectronics have resulted in exponential growth in the number of implanted medical devices. Most people do well adjusting to their devices, but others show signs of depression and/or anxiety. The Implanted Device Adjustment Scale (IDAS) was developed to measure how well a person is adjusting to an implanted device. First, a pool of items was generated and reviewed by 2 panels of clinicians and psychometricians for content validity. The revised version was then administered to a small sample that provided information about problematic items. Finally, a convenience sample of 45 persons (66% males) with implanted devices (18 pacemakers only, 37 cardioverter/defibrillators) completed the revised IDAS twice. After deleting weak items, the Cronbach alpha was 0.90. No age, gender, or device differences were found. Test-retest reliability was 0.92. The IDAS may be useful to evaluate how well a person is adjusting to her/his device. This may lead to more timely and appropriate interventions to improve outcomes.

Adaptation, Psychological↗