PubMed Health⌕ Search

Biomedical subjects

Richard Johanson

Publications and source records attributed to Richard Johanson.

6 recordsLinked to original sources

Review of singleton fetal and neonatal deaths associated with cranial trauma and cephalic delivery during a national intrapartum-related confidential enquiry.

OBJECTIVE: To review delivery details of intrapartum-related fetal and neonatal deaths with singleton cephalic presentation and birthweight of 2500 g or more in which traumatic cranial or cervical spine injury or substantial difficulty at delivery of the head was a dominant feature. DESIGN: Review of freestyle summary reports and standard questionnaire responses submitted to the national secretariat for the Confidential Enquiry into Stillbirths and Death in Infancy (CESDI) during the 1994/1995 intrapartum-related mortality enquiry following regional multidisciplinary panel review. SETTING: United Kingdom. SAMPLE: Of the 873 cases of intrapartum-related deaths reported in the 1994-1995 national enquiry, 709 weighed more than 2499 g. REPORTS: from 181 (89 from 1994 and 92 from 1995) with a chance of meeting criteria for cranial or cervical trauma as significant contributors to death were examined in detail. Thirty-seven were judged to meet the criteria stated in the objectives (23 from 1994 and 14 from 1995) and form the basis for this review. METHODS: Electronic and hand search of CESDI records relating to intrapartum-related deaths. MAIN OUTCOME MEASURES: Intrapartum events and features of care. RESULTS: There was evidence of fetal compromise present before birth in 33 of the 37 (89%) study group cases reviewed. One delivery was performed vaginally without instrumentation, and in one there was no attempt at vaginal delivery before caesarean section (CS) in the second stage of labour. Twenty-four cases (65%) were delivered vaginally and 11 (30%) by CS after failure to deliver vaginally with instruments. A single instrument was used in six cases of vaginal delivery (four ventouse and two Kjelland's forceps). At least two separate attempts with different instruments were made in 24 cases. Overall, the ventouse was used in 27 cases and forceps in 29 cases. In six cases, three separate attempts were made with at least two different instruments, all of which included use of ventouse. The grade of operator was recorded in 27 cases. Of these, a consultant obstetrician was present at only one delivery and no consultant was recorded to have made the first attempt to deliver a baby. In six cases, shoulder dystocia was also reported. CONCLUSIONS: This study suggests a lower incidence of death from difficult cephalic delivery and cranial trauma than previously reported. The CESDI studies were believed to have achieved high levels of ascertainment for all intrapartum-related deaths from which the cases reported here were selected. Strictly applied entry criteria used in this study could have restricted the number of cases considered as could limited in vivo or postmortem investigations and lack of detailed autopsy. When cranial traumatic injury was observed, it was almost always associated with physical difficulty at delivery and the use of instruments. The use of ventouse as the primary or only instrument did not prevent this outcome. Some injuries occurred apparently without evidence of unreasonable force, but poorly judged persistence with attempts at vaginal delivery in the presence of failure to progress or signs of fetal compromise were the main contributory factor regardless of which instruments were used.

Apgar Score↗

A criterion audit of women's awareness of blood transfusion in pregnancy.

BACKGROUND: In the Confidential Enquiry into Maternal Deaths (CEMD) Report, the very high risk of mortality in women who refuse blood transfusions is highlighted. The objectives were to establish current knowledge about, and views of transfusion in our pregnant population and to establish the level of compliance with the set audit standard. METHOD: Questionnaire survey of 228 women, including both high and low risk pregnancies, attending ante-natal clinic between 2-9 May 2000 at the North Staffordshire Maternity Hospital, Stoke on Trent. RESULTS: The response rate was 100%. Only 43% were aware of the possible need for blood transfusion in pregnancy. If a blood transfusion was required, 92% stated that they would accept a blood transfusion in pregnancy. Four percent stated that they would not accept a transfusion because of religious reasons and risk of infection and the remaining four percent did not declare a reason. CONCLUSIONS: This short survey identified that 57% of women were not aware of the possible need for blood transfusion during pregnancy. There is a need for more information to be shared on this subject with all antenatal women. Women who would refuse a transfusion need to be identified at booking and be referred for counselling and a management plan made for pregnancy, labour and delivery.

Journal Article↗

Continuous versus interrupted perineal repair with standard or rapidly absorbed sutures after spontaneous vaginal birth: a randomised controlled trial.

BACKGROUND: Trauma to the perineum is a serious and frequent problem after childbirth, with about 350000 women each year in the UK needing sutures for perineal injury after spontaneous vaginal delivery, and many millions more worldwide. We compared the continuous technique of perineal repair with the interrupted method, and the more rapidly absorbed polyglactin 910 suture material with the standard polyglactin 910 material. METHODS: 1542 women who had a spontaneous vaginal delivery with a second-degree perineal tear or episiotomy were randomly allocated to either the continuous (n=771) or interrupted (771) suturing method, and to either the more rapidly absorbed polyglactin 910 suture material (772) or standard polyglactin 910 material (770). Primary outcomes were pain 10 days after delivery and superficial dyspareunia 3 months postpartum. Analysis was by intention to treat. FINDINGS: At day 10, three women had dropped out of the study. Significantly fewer women reported pain at 10 days with the continuous technique than with the interrupted method (204/770 [26.5%] vs 338/769 [44.0%], odds ratio 0.47, 95% CI 0.38-0.58, p<0.0001). Occurrence of pain did not differ significantly between groups assigned the more rapidly absorbed material or standard material (256/769 [33.3%] vs 286/770 [37.1%], 0.84, 0.68-1.04, p=0.10). Women reported no difference in superficial dyspareunia at 3 months for the continuous vs the interrupted method (98/581 [16.9%] vs 102/593 [17.2%], 0.98, 0.72-1.33, p=0.88) or the more rapidly absorbed versus standard material (105/586 [17.9%] vs 95/588 [16.2%], 1.13, 0.84-1.54, p=0.42). Suture removal was done less with the more rapidly absorbed material than with standard suture material (22/769 [3%] vs 98/770 [13%], p<0.0001), and with the continuous versus interrupted method (24/770 [3%] vs 96/769 [12%], p<0.0001). INTERPRETATION: A simple and widely practicable continuous repair technique can prevent one woman in six from having pain at 10 days. Also, the more rapidly absorbed polyglactin 910 material obviates need for suture removal up to 3 months postpartum for one in ten women sutured.

Adult↗

MOET: Bangladesh--an initial experience.

OBJECTIVES: To summarize the quantitative and qualitative immediate assessments of the Managing Obstetric Emergencies and Trauma (MOET) course and to examine the individual changes in score obtained for each of the scenarios. METHODS: Students' knowledge before and after the course was evaluated with a standardized comprehensive questionnaire. RESULTS: All candidates showed an improvement in postcourse, compared to precourse, scores. In the individual score analysis only one scenario showed a non-significant change. The majority of other scenarios showed highly significant improvement between the two scores. CONCLUSION: This paper summarises the development of the first MOET course to be run outside the UK. It demonstrates the reliability of the model-based scenario foundation with a highly significant improvement in knowledge about obstetric emergency management. Further evaluation of longer term practice changes is now required.

Clinical Competence↗

Achieving sustainable quality in maternity services - using audit of incontinence and dyspareunia to identify shortfalls in meeting standards.

BACKGROUND: Some complications of childbirth (for example, faecal incontinence) are a source of social embarrassment for women, and are often under reported. Therefore, it was felt important to determine levels of complications (against established standards) and to consider obstetric measures aimed at reducing them. METHODS: Clinical information was collected on 1036 primiparous women delivering at North and South Staffordshire Acute and Community Trusts over a 5-month period in 1997. A questionnaire was sent to 970 women which included self-assessment of levels of incontinence and dyspareunia prior to pregnancy, at 6 weeks post delivery and 9 to 14 months post delivery. RESULTS: The response rate was 48%(470/970). Relatively high levels of obstetric interventions were found. In addition, the rates of instrumental deliveries differed between the two hospitals. The highest rates of postnatal symptoms had occurred at 6 weeks, but for many women problems were still present at the time of the survey. At 9-14 months high rates of dyspareunia (29%(102/347)) and urinary incontinence (35%(133/382)) were reported. Seventeen women (4%) complained of faecal incontinence at this time. Similar rates of urinary incontinence and dyspareunia were seen regardless of mode of delivery. CONCLUSION: Further work should be undertaken to reduce the obstetric interventions, especially instrumental deliveries. Improvements in a number of areas of care should be undertaken, including improved patient information, improved professional communication and improved professional recognition and management of third degree tears. It is likely that these measures would lead to a reduction in incontinence and dyspareunia after childbirth.

Journal Article↗