PubMed Health⌕ Search

Biomedical subjects

Richard W Yee

Publications and source records attributed to Richard W Yee.

13 recordsLinked to original sources

Excimer laser exacerbation of Avellino corneal dystrophy.

We review the clinical, histopathological, and ultrastructural findings and DNA phenotyping of a patient with Avellino corneal dystrophy exacerbated by laser in situ keratomileusis. The findings are reported and interpreted in the context of a literature review. The case highlights the possible difficulty of recognizing subtle dystrophic findings, as well as the importance of avoiding refractive surgical intervention in patients with Avellino corneal dystrophy to avoid exacerbation of dystrophic deposits in the cornea and subsequent reduction in vision.

Adult↗

The zebrafish cornea: structure and development.

PURPOSE: To evaluate the zebrafish as a model for the studies of corneal development and disease. METHODS: Zebrafish embryos and larvae at various stages of development were used for documenting corneal morphogenesis and differentiation. Corneal samples were collected from embryos, larvae, and adult zebrafish for histologic and electron microscopy analysis. Expression patterns of corneal polypeptides were investigated by immunostaining of sections. RESULTS: The zebrafish cornea develops rapidly during embryogenesis, so that its three major layers, the epithelium, the stroma, and the endothelium, are well formed by day 3 postfertilization. The subsequent steps of corneal differentiation, such as the thickening of the corneal stroma, proceed relatively slowly. Several polypeptides are highly enriched in the epithelium or the stroma of the larval and adult zebrafish cornea and are excellent markers of corneal differentiation. CONCLUSIONS: Development and differentiation of the zebrafish cornea are easily accessible to analysis. Anatomic and ultrastructural characterization of the zebrafish cornea demonstrates many similarities to the human cornea and provides the basis for the use of the zebrafish model both to analyze the basic genetic mechanisms of corneal development and to study the causes of corneal disease.

Animals↗

Recurrence of chromosome 10 Thiel-Behnke corneal dystrophy (CDB2) after excimer laser phototherapeutic keratectomy or penetrating keratoplasty.

PURPOSE: To evaluate the recurrence of Thiel-Behnke dystrophy (linked to the 10 q23-q24 locus) after phototherapeutic keratectomy or penetrating keratoplasty. METHODS: This is a retrospective study of 4 patients (8 eyes) who underwent phototherapeutic keratectomy and 1 patient (2 eyes) who underwent penetrating keratoplasty. Best corrected visual acuity was assessed, and biomicroscopic examinations for evidence of recurrent dystrophy were documented and photographed. The location, lesion distribution, and lesion pattern of any recurrence was noted. RESULTS: Follow-up ranged from 8 months to 25 years (mean +/- SD 9.7 +/- 7.97 years). All 10 eyes showed biomicroscopic evidence of central recurrence. Six eyes showed an intermediate zone of honeycomb opacities as well as a peripheral zone of focal and geographic lesions. Despite the high incidence of recurrence, functional central visual acuity was maintained. All eyes maintained functional best corrected visual acuity (ranging from 20/25 to 20/80) despite the postoperative recurrence. CONCLUSION: Recurrence of Thiel-Behnke corneal dystrophy is extremely high after either phototherapeutic keratectomy or penetrating keratoplasty. Despite the high incidence of recurrence, the central cornea is the last to be affected. The peripheral-to-central progression of the lesions points to an epithelial origin for the pathogenesis of the dystrophy. Phototherapeutic keratectomy in the treatment of Thiel-Behnke corneal dystrophy offers a safe and effective treatment modality, providing patients up to 8 years of improved vision ranging from 8 months to 8 years (mean +/- SD 3.7 +/- 2.7 years) and delaying or circumventing the need for more invasive intraocular surgical intervention.

Aged↗

A randomized, investigator- masked clinical trial comparing the efficacy and safety of gatifloxacin 0.3% administered BID versus QID for the treatment BID versus QID for the treatment of acute bacterial conjunctivitis of acute bacterial conjunctivitis.

PURPOSE: To compare the efficacy and safety of To compare the efficacy and safety of gatifloxacin ophthalmic solution 0.3% (Zymar) administered BID versus QID in patients with acute bacterial conjunctivitis. METHODS: In a randomized, investigator-masked clinical trial, patients diagnosed with bacterial conjunctivitis (based on signs and symptoms) received gatifloxacin either BID or QID for 5 days. Visits were scheduled at day 0, day 3, and day 5. Conjunctival cultures were taken at each visit. The clinical cure rate at day 5 was determined for the entire patient population (primary endpoint). Additionally, clinical cure at day 5 was evaluated for a population of patients defined a priori (per protocol) as being culture positive at baseline and with no substantial protocol deviations. Safety was determined through recording of adverse events. Minimal inhibitory concentrations (MIC) and susceptibility of isolates to gatifloxacin were determined using a broth dilution method. RESULTS: Patient characteristics in both the BID and QID groups (N = 104) were similar in terms NN of baseline demographics and disposition. The clinical cure rate on day 5 in the entire, intentto-treat (ITT) population was 86.5% (45/52) in the gatifloxacin BID group and 71.2% (37/52) in the gatifloxacin QID group (95% CI: [-0.03, 30.80]; p = 0.096). In both treatment groups, 5/52 patients (9.6%) reported adverse events. The most common adverse event was conjunctivitis. No serious adverse events were reported. In the a priori-defined per-protocol (PP) population, the clinical cure rate on day 5 was 95.5% (21/22) in the gatifloxacin BID group and 85.7% (18/21) in the gatifloxacin QID group (95% CI: [-7.57, 21.05]; p = 0.294). At baseline, 96.1% (98/102) of the isolates were susceptible to gatifloxacin. The overall MIC(90) (mean +/- standard error of the mean) was 0.5 +/- 1.3 microg/mL. CONCLUSION: In this study, gatifloxacin 0.3% administered BID was as effective and as safe as gatifloxacin 0.3% administered QID for 5 days for the treatment of bacterial conjunctivitis.

Acute Disease↗

Update on laser subepithelial keratectomy (LASEK).

PURPOSE OF REVIEW: This study reviews current concepts in laser subepithelial keratectomy (LASEK), variations in LASEK techniques, the role of pharmacology in LASEK, and optimizing outcomes in LASEK. RECENT FINDINGS: Recent studies continue to support the use of LASEK over that of LASIK in the correction of refractive error. In addition, the advent of pharmacological/biologic intervention, improved algorithms, and wavefront technology have expanded the armamentarium available to ophthalmologists in the maximization of LASEK outcomes. SUMMARY: LASEK offers an excellent profile in terms of both final outcome (uncorrected visual acuity) and safety (best corrected visual acuity). Untoward effects of LASEK are readily prevented/treated with a variety of agents. Postoperative pain can be ameliorated using topical and oral analgesia. Infection can be most effectively addressed with the fourth generation of fluoroquinolones. Haze may be treated or prevented using numerous remedies namely autologous serum, steroids, ascorbic acid, mitomycin-c, and NSAIDS. Wavefront combined with LASEK rather than with LASIK may offer the best refractive outcome.

Humans↗

Cleavage of corneal basement membrane components by ethanol exposure in laser-assisted subepithelial keratectomy.

PURPOSE: To determine the anatomic cleavage plane after exposure to 20% ethanol for approximately 20 to 25 seconds to create an epithelial flap in laser-assisted subepithelial keratectomy (LASEK). SETTING: Ocular Surface Research & Education Foundation, Miami, Florida, and Hermann Eye Center Refractive Surgery Center, Houston, Texas, USA. METHODS: Immunofluorescence staining using monoclonal antibodies against laminin 5, collagen VII, and integrins beta(1) and beta(4) was performed to determine the anatomic location of the cleavage plane in an epithelial flap created by 20-second exposure to 20% ethanol in cadaver eyes and in epithelial flaps obtained from LASEK patients. RESULTS: Immunofluorescence staining to laminin 5 and integrin beta(4) was patchy in the lifted flap and the remaining corneal basement membrane. Immunostaining to collagen VII, the main component of anchoring fibrils, remained exclusively in the corneal bed. Immunostaining to integrin beta(1), present in the pericellular location of all epithelial cell layers, remained exclusively in the epithelial flap. This finding was consistent in cadaver corneas and LASEK epithelial flaps. CONCLUSIONS: The cleavage plane of the ethanol-induced corneal epithelial flap is located between the lamina lucida and the lamina densa of the basement membrane, where integrin beta(4) interacts with laminin 5 to form hemidesmosomes.

Antibodies, Monoclonal↗

Exclusion of the human collagen type XVII (COL17A1) gene as the cause of Thiel-Behnke corneal dystrophy (CDB2) on chromosome 10q23-q25.

PURPOSE: Determination of the gene causing Thiel-Behnke Corneal Dystrophy (CDB2) would have important clinical implications. Previous studies in our laboratory have suggested that the COL17A1 gene may be the cause of Thiel-Behnke Corneal Dystrophy (CDB2) on Chromosome 10q23-q25. METHODS: We evaluated a five-generation family with CDB2 mapped to chromosome 10. Many of these family members were diagnosed by slit-lamp microscopy. In addition, genomic DNA was isolated and purified from peripheral blood samples. The COL17A1 gene was screened for possible disease causing mutations by PCR and DNA sequencing analysis. RESULTS: No disease-causing mutations were found in any of the 56 exons of the COL17A1 gene or in any of the flanking intron/exon junctions. CONCLUSIONS: Mutations in the coding sequence of the human collagen XVII (COL17A1) gene are not the cause of CDB2.

Adenine↗

Comparison of the relative toxicity of travoprost 0.004% without benzalkonium chloride and latanoprost 0.005% in an immortalized human cornea epithelial cell culture system.

The purpose of this study was to compare the relative toxicity of a new topical ophthalmic glaucoma medication, travoprost 0.004% without benzalkonium chloride (BAK), with that of commercially available latanoprost 0.005% (preserved with 0.02% BAK) in immortalized human corneal epithelial cells (HCEs). Tissue culture plates (96 well) containing HCEs were divided into 6 groups. Two groups served as negative controls (70% methanol and gentamicin). Another 2 groups--1 in corneal epithelial culture media and the other in a hydroxypropyl (HP)-Guargellable lubricant eyedrop--served as live controls. The travoprost 0.004% without BAK and latanoprost 0.005% groups were exposed to 100 microL of the undiluted solutions. Cells were incubated for 25 min at 37 degree C. A live/dead assay was used to measure the effects of travoprost without BAK and of latanoprost on HCEs compared to 70% methanol and culture medium. Between the 2 glaucoma medications tested, travoprost 0.004% preserved without BAK showed significantly less toxicity on HCEs than did latanoprost 0.005%. This difference may have ramifications in terms of tolerability for patients who use these topical glaucoma drugs on a long-term basis.

Antihypertensive Agents↗

Computer vision syndrome: a review.

As computers become part of our everyday life, more and more people are experiencing a variety of ocular symptoms related to computer use. These include eyestrain, tired eyes, irritation, redness, blurred vision, and double vision, collectively referred to as computer vision syndrome. This article describes both the characteristics and treatment modalities that are available at this time. Computer vision syndrome symptoms may be the cause of ocular (ocular-surface abnormalities or accommodative spasms) and/or extraocular (ergonomic) etiologies. However, the major contributor to computer vision syndrome symptoms by far appears to be dry eye. The visual effects of various display characteristics such as lighting, glare, display quality, refresh rates, and radiation are also discussed. Treatment requires a multidirectional approach combining ocular therapy with adjustment of the workstation. Proper lighting, anti-glare filters, ergonomic positioning of computer monitor and regular work breaks may help improve visual comfort. Lubricating eye drops and special computer glasses help relieve ocular surface-related symptoms. More work needs to be done to specifically define the processes that cause computer vision syndrome and to develop and improve effective treatments that successfully address these causes.

Asthenopia↗

Laser epithelial keratomileusis for myopia with the autonomous laser.

PURPOSE: To describe the refractive outcome, objective clinical data, and subjective patient experiences after laser epithelial keratomileusis (LASEK) at 1, 3, and 6 months after surgery. METHODS: This was a retrospective, nonrandomized, comparative study of 58 LASEK-treated eyes (36 patients) with myopia (with and without astigmatism) between -1.50 and -14.75 D (mean -7.80 +/- 2.90 D, median -7.90 D). Refractive surgery was performed using the Alcon Summit Autonomous LADAR Vision excimer laser. Manifest refraction, best-spectacle and uncorrected Snellen visual acuity, stability of refraction, and corneal haze were evaluated before surgery and up to 6 months after surgery. A group of randomly selected LASIK-treated eyes were compared at each time point. RESULTS: Patients who opted for monovision (n=12) were excluded. In the emmetropia targeted eyes (n=46), 45%, 83%, 85%, and 89% achieved 20/40 or better uncorrected Snellen visual acuity (UCVA) at 1 day, 1 week, 2 weeks, and 1 month respectively. At 6 months, 73% (n=28) of eyes treated achieved UCVA 20/20 with 97% achieving 20/40 or better (mean, -0.51 D). At 3 and 6 months, 71% (n=46) and 68% (n=28) were within +/- 0.50 D of emmetropia. The percentage of eyes that achieved UCVA 20/40 or better at 6 months was 97% (n=28). Visually significant corneal haze was evident in two LASEK-treated patients (four eyes) at 6 months. No eyes lost two or more lines of best spectacle-corrected Snellen visual acuity. CONCLUSIONS: Preliminary data suggest that LASEK appears to be a safe, effective, and comparable alternative to LASIK, even for higher amounts of myopia. A prospective, randomized clinical trial is needed to better define the role of LASEK as it compares to other refractive procedures, specifically LASIK and PRK.

Adult↗

Electron microscopy of surface smoothness of porcine corneas and acrylic plates with four brands of excimer laser.

PURPOSE: This study compares ablation smoothness patterns produced on four different excimer laser devices available for photorefractive surgery. METHODS: VISX calibration plastic and porcine cornea were ablated with standard -3.00-D, -6.00-D, and -9.00-D settings using four different excimer lasers: VISX S2 Smooth Scan, Nidek EC-5000, Autonomous Ladar Vision System, and Bausch and Lomb Technolas. Electron microscopy and laser interferometry were used for qualitative evaluation of the ablated surfaces. Corneal ablation surface smoothness was graded by ten independent observers. Calibration plastic ablated surfaces were evaluated quantitatively for smoothness by laser interferometry. RESULTS: The independent observer assessment of corneal ablation surface smoothness demonstrated that the Autonomous small spot Gaussian profile laser produced the smoothest ablation surfaces, followed by the other broad beam lasers. In comparing ablation smoothness among various refractive powers (-9.00 D, -6.00 D, and -3.00 D), a trend was observed that indicated a correlation of higher refractive settings with decreasing surface smoothness. However, this trend was not statistically significant. The quantitative laser interferometry measurements supported the independent observer ranking of the Autonomous flying small spot ablation profile as the smoothest. However, there were differences between the laser interferometry smoothness rankings and independent observer smoothness rankings. CONCLUSION: There were significant differences in ablation surface smoothness among the four excimer lasers tested.

Animals↗

Prediction of corneal haze using an ablation depth/corneal thickness ratio after laser epithelial keratomileusis.

PURPOSE: To investigate the usefulness of ablation depth/corneal thickness (AD/CT) ratio to predict corneal haze after laser epithelial keratomileusis (LASEK) using a retrospective, comparative, interventional case series. METHODS: Fifty patients (90 eyes; mean age 40.9 years) with myopia, hyperopia, and/or astigmatism underwent bilateral or unilateral LASEK for correction of refractive error. After epithelial flaps were created using an 18% alcohol solution, bilateral or unilateral LASEK was performed using the Alcon Autonomous LADARVision 4000 excimer laser. Visual acuity (best spectacle-corrected and uncorrected) and refractive error were measured before and after LASEK. Corneas were assessed by two independent evaluators under a slit-lamp biomicroscope with broad tangential illumination. The relative haze scale was quantitated: 0 (clear), 0.5+ (trace), 1+ (mild), 2+ (moderate), 3+ (marked), and 4+ (severe). RESULTS: Mean preoperative spherical equivalent refraction was -5.46 +/- 3.74 D (range -12.375 to +5.00 D), mean ablation depth was 93.04 +/- 45.03 microm (range 21.2 to 207.2 microm), and mean AD/CT ratio was 0.18 +/- 0.09 (range 0.04 to 0.41). Of 90 eyes, 40 eyes had a higher ablation depth (AD/CT ratio > 0.18) and 50 eyes had a lower ablation depth (AD/CT ratio < 0.18); 92.5% of eyes in the higher ratio group developed clinically significant haze (1+ or greater). In the lower ratio group, 94% of eyes developed no more than 1+ corneal haze, if any. CONCLUSION: The ablation depth/corneal thickness ratio is useful for predicting corneal haze after LASEK. An AD/CT ratio of 0.18 or more suggests that patients have a high risk of developing clinically significant haze (1+ or more) after LASEK.

Adult↗