Diffusion-tensor MR imaging in children with developmental delay: preliminary findings.

PURPOSE: To determine whether diffusion-tensor magnetic resonance (MR) imaging can depict abnormalities in patients with a diagnosis of developmental delay but structurally normal brain MR imaging results. MATERIALS AND METHODS: Twenty pediatric patients who received a diagnosis of developmental delay underwent brain MR examinations, including diffusion-tensor MR imaging. The MR findings in these patients were compared with those in 10 age-matched neurodevelopmentally healthy children. Diffusion constant (Dav) and anisotropy were measured bilaterally in regions of interest in the centrum semiovale, corona radiata, internal capsule, corpus callosum, and subcortical white matter of the frontal and parieto-occipital lobes. By using a one-tailed Student t test in the positive direction for Dav and in the negative direction for anisotropy and P <.05 to indicate a significant difference, the Dav and anisotropy values for children with developmental delay were compared with those for children who were neurodevelopmentally healthy. RESULTS: The children with developmental delay had significant increases in Dav in all measured structures (P, <.001 to <.03). Significant decreases in anisotropy were detected in all white matter fiber tracts studied (P, <.001 to <.03) except the posterior limb of the internal capsule. CONCLUSION: In the children with developmental delay, diffusion-tensor MR imaging depicted decreases in anisotropy and increases in Dav in the white matter fiber tracts, which appeared to be normal at conventional MR imaging.

Anisotropy↗

Atherosclerotic disease distribution in carotid and vertebrobasilar arteries: clinical experience in 100 patients undergoing fluoro-triggered 3D Gd-MRA.

PURPOSE: To determine how often three-dimensional gadolinium-enhanced magnetic resonance angiography (3D Gd-MRA) shows disease outside of the standard two-dimensional time-of-flight magnetic resonance angiography (2D TOF-MRA) imaging volume. MATERIALS AND METHODS: One hundred consecutive patients with known or suspected cerebrovascular disease were examined using fluoro-triggered 3D Gd-MRA with a 1.5 Tesla scanner. All vessel segments from the aortic arch to the circle of Willis were independently evaluated for the presence of occlusive disease, ulceration, aneurysm, and anatomic variations by two radiologists blinded to clinical information. Branch vessel and circle of Willis visibility were also assessed. Kappa statistics were calculated to determine interobserver agreement. RESULTS: Interobserver agreement for the degree of stenosis was good to excellent (kappa = 0.83-1.0). Disagreement was more frequent in the cases of mild stenoses and was less frequent for stenoses > or = 50%. In 38% of the patients, 3D Gd-MRA demonstrated either ulcerated plaques in carotid arteries (N = 14) or stenosis > or = 50% in great vessel (N = 20) and/or vertebral artery (N = 38) origins, none of which can be readily evaluated on standard TOF-MRA. CONCLUSION: Fluoro-triggered 3D Gd-MRA provides a comprehensive evaluation of the carotid arteries including all vessel segments from the aortic arch to the circle of Willis.

Adult↗

Fiber tracking using magnetic resonance diffusion tensor imaging and its applications to human brain development.

Diffusion tensor imaging is unique in its ability to noninvasively visualize white matter fiber tracts in the human brain in vivo. Diffusion is the incoherent motion of water molecules on a microscopic scale. This motion is itself dependent on the micro-structural environment that restricts the movement of the water molecules. In white matter fibers there is a pronounced directional dependence on diffusion. With white matter fiber tracking or tractography, projections among brain regions can be detected in the three-dimensional diffusion tensor dataset according to the directionality of the fibers. Examples of developmental changes in diffusion, tracking of major fiber tracts, and examples of how diffusion tensor tractography and functional magnetic resonance imaging can be combined are provided. These techniques are complimentary and allow both the identification of the eloquent areas of the brain involved in specific functional tasks, and the connections between them. The noninvasive nature of magnetic resonance imaging will allow these techniques to be used in both longitudinal developmental and diagnostic studies. An overview of the technique and preliminary applications are presented, along with its current limitations.

Anisotropy↗

Quantitative evaluation of susceptibility and shielding effects of nitinol, platinum, cobalt-alloy, and stainless steel stents.

The purpose of this study is to quantitatively estimate the shielding and susceptibility effects of commonly used metallic stents on MR signal. Two experiments were performed using a 3D gradient echo sequence with short TE to image a stent phantom: 1) short TR and high flip angle (contrast enhanced MRA parameters), and 2) long TR (TR >> T(1)) and low flip angle. The factor characterizing susceptibility effects was estimated from the signal phase of the first experiment, and then the factor characterizing the shielding effects was derived from the second experiment. Susceptibility induced signal loss was negligible (<1%) for nonstainless-steel (nitinol, platinum, and cobalt-alloy) stents and totally destructive (100%) for the stainless steel stent. Signal loss due to RF shielding was 31-62% for nitinol stents, 14-50% for platinum stents, 50-77% for the cobalt-alloy stents (undetermined for the stainless steel stent), varied with stent orientation, diameter, and wall geometry. In summary, stents made of nitinol, platinum, and cobalt-alloy have negligible susceptibility effects but stents made of stainless steel may have complete dephasing. All stents have substantial shielding effects, which vary with composition, geometry, and orientation. Large platinum stents may have the smallest artifacts and are the best suited for postinterventional MR imaging.

Alloys↗

A teaching tool in spinal anesthesia.

The purpose of the present study was to develop and evaluate a new model for teaching spinal anesthesia to nurse anesthesia students. The new teaching tool was evaluated to determine if the use of a spinal model allowing visual combined with the haptic sense was more effective than the traditional spinal model using primarily the haptic sense. Specifically, was there a difference in the number of successful passes, the amount of time taken for each spinal attempt, and the number of participants who reached 90% proficiency when comparing the use of both spinal models? Data analysis using a paired t test and Wilcoxon signed rank test revealed that the number of successes, amount of time needed to complete 1 needle pass, and point at which 90% proficiency was reached with the newly designed model were significantly greater than with the traditional model. The present study demonstrated that significant differences exist between participants who used both visual and haptic sense and participants who used primarily the haptic sense when performing spinal anesthesia. Findings of this study will be used to provide information that may be used to change the current curriculum for the training of nurse anesthesia students in spinal anesthetic procedures.

Anesthesia, Spinal↗

New developments in high-throughput resequencing and variation detection using high density microarrays.

We developed a high-throughput method for resequencing for single nucleotide polymorphism (SNP) discovery using high-density microarrays. Over the two-year course of this study a number of improvements in sample preparation methods, hybridization assay, array handling, and analysis method were developed and implemented. DNA from 40 unrelated individuals of three different ethnic origins was amplified, labeled, and hybridized to arrays designed with probes representing genomic, coding, and regulatory regions. Protocol improvements including the use of long PCR and semi-automation reduced labeling and fragmentation costs by 33%. Automation improvements include the development of a scanner autoloader for arrays, a faster array wash station, and a linked laboratory tracking and data management system. Validation of a smaller feature size, 20 x 24 microns, allowed the simultaneous screening of 30-kb sense and 30-kb antisense DNA on each microarray, increasing throughput to 1.4 Mb per day per two laboratory personnel. More than 15,000 SNPs were identified in 8.3 Mb of the human genome using high-density resequencing and variation detection arrays (microarrays).

Automation↗

k-space interpretation of the Rose Model: noise limitation on the detectable resolution in MRI.

Noise limitation on the detected spatial resolution, described by the Rose Model, is well known in X-ray imaging and routinely used in designing X-ray imaging protocols. The purpose of this article is to revisit the Rose Model in the context of MRI where image data are acquired in the spatial frequency domain. A k-space signal-to-noise ratio (kSNR) is introduced to measure the relative signal and noise powers in a circular annulus in k-space. It is found that the kSNR diminishes rapidly with k-space radius. The Rose criterion that the voxel SNR approximately 4 is translated to kSNR cutoff values was tested using theoretical derivation and experimental histogram analysis. Experiments demonstrate that data acquisition beyond this cutoff k-space radius adds little or no information to the image. In order to reduce the noise limit on spatial resolution, the signal strength must be improved through means such as increasing the coil sensitivity, contrast enhancement, and signal averaging. This finding implies that the optimal k-space volume to be sampled or the optimal scan time in MRI should be matched to the relative SNR level.

Magnetic Resonance Imaging↗

Automatic selection of mask and arterial phase images for temporally resolved MR digital subtraction angiography.

For time-resolved background-subtracted contrast-enhanced magnetic resonance angiography, the bright and sparse arterial signal allows unique identification of contrast bolus arrival in the arteries. This article presents an automatic filtering algorithm using such arterial characterization for selecting arterial phase images and mask images to generate an optimal summary arteriogram. A paired double-blinded comparison demonstrated that this automatic algorithm is as effective as the manual process.

Adult↗

Cerebral activation during vagus nerve stimulation: a functional MR study.

PURPOSE: To study the short-term effects of vagus nerve stimulation (VNS) on brain activation and cerebral blood flow by using functional magnetic resonance imaging (fMRI). METHODS: Five patients (three women, two men; mean age, 35.4 years) who were treated for medically refractory epilepsy with VNS, underwent fMRI. All patients had a nonfocal brain MRI. The VNS was set at 30 Hz, 0.5-2.0 mA for intervals of activation of 30 s on and 30 s off, during which the fMRI was performed. Statistical parametric mapping (SPM) was used to determine significant areas of activation or inhibition during vagal nerve stimulation (p < 0.05). RESULTS: VNS-induced activation was detected in the thalami bilaterally (left more than right), insular cortices bilaterally, ipsilateral basal ganglia and postcentral gyri, right posterior superior temporal gyrus, and inferomedial occipital gyri (left more than right). The most robust activation was seen in the thalami (left more than right) and insular cortices. CONCLUSIONS: VNS-induced thalamic and insular cortical activation during fMRI suggests that these areas may play a role in modulating cerebral cortical activity, and the observed decrease in seizure frequency in patients who are given VNS may be a consequence of this increased activation.

Adult↗

Bolus arterial-venous transit in the lower extremity and venous contamination in bolus chase three-dimensional magnetic resonance angiography.

RATIONALE AND OBJECTIVES: To investigate the phenomena and causes for undesired venous signal in the distal station of bolus chase 3D MRA. METHODS: Consecutive patients (in 8 months) undergoing peripheral MRA consisting of 2D projection MRA of the tibial trifurcation and 3D bolus chase MRA were retrospectively evaluated. Venous contamination in mid-calf in bolus chase 3D MRA was correlated to the arterial phase duration, the time between the contrast bolus arrival and venous return measured on time resolved 2D images. Statistical analyses were performed to identify the clinical parameters indicative of venous contamination. RESULTS: The arterial phase durations at the mid-calf were 49 +/- 8 seconds on 101 legs without venous signal in the bolus chase 3D MRA, 35 +/- 9 seconds on 13 legs with moderate venous signal, and 20 +/- 4 seconds on 40 legs with substantial venous signal; the differences were significant among different venous signal levels (P < 0.001 for all pairs). Legs with cellulitis had shorter arterial phase and more venous contamination than legs without cellulitis (P < 0.05). Patients with myocardial infarction had longer arterial phase and less venous contamination than patients without myocardial infarction (P < 0.01). CONCLUSION: Venous signal in the distal calf station of bolus chase 3D peripheral MRA is caused by fast arterial-venous transit. It is worse in legs with cellulitis and less in patients with a history of myocardial infarction.

Aged↗

Postprocessing techniques for time-resolved contrast-enhanced MR angiography.

The purpose of this study was to improve dynamic two-dimensional projection magnetic resonance digital subtraction angiography by using remasking and filtering postprocessing techniques. Four methods were evaluated in 50 patients: default mask subtraction, remasked subtraction, filtering based on the SD, and linear filtering. The results demonstrated that postprocessing techniques such as linear filtering can reduce background motion artifacts and improve arterial contrast-to-noise ratio.

Adult↗

Peripheral vascular disease: combined 3D bolus chase and dynamic 2D MR angiography compared with x-ray angiography for treatment planning.

PURPOSE: To compare combined three-dimensional (3D) and two-dimensional (2D) contrast material-enhanced magnetic resonance (MR) angiography with x-ray angiography for planning treatment of peripheral vascular disease. MATERIALS AND METHODS: Three radiologists retrospectively reviewed the pretreatment x-ray angiographic and MR angiographic studies obtained in 30 consecutive patients: 15 patients (15 limbs) evaluated for limb salvage and 15 patients (20 limbs) evaluated because of claudication. MR angiography included acquisition of 2D contrast-enhanced MR digital subtraction angiograms of the area from the adductor canal to the feet and 3D spoiled gradient-recalled-echo bolus chase MR angiograms obtained in three stations from the aorta to the middle portion of the calf. Each reader reviewed the x-ray and MR angiograms to determine the inflow and outflow segments for a hypothetical bypass graft placement. RESULTS: The three readers selected identical segments for inflow at MR angiography and x-ray angiography in 32, 32, and 35 of the 35 limbs evaluated (mean percentages of agreement [95% CI ]: 91% [77%, 98%], 91% [77%, 98%], and 95% [90%, 100%], respectively). The readers selected identical segments for outflow in 32, 32, and 34 of the 35 limbs evaluated (mean percentages of agreement [95% CI]: 91% [77%, 98%], 91% [77%, 98%], and 97% [85%, 100%], respectively). CONCLUSION: Preliminary data support the combining of 2D MR digital subtraction angiography with 3D bolus chase MR angiography to extend the utility of 3D MR angiography in treatment planning to include patients being evaluated for limb salvage, as well as those being evaluated for claudication.

Adult↗

Contrast material travel times in patients undergoing peripheral MR angiography.

PURPOSE: To retrospectively review time-resolved two-dimensional projection magnetic resonance (MR) angiographic data to characterize the passage of gadolinium-based contrast material down the leg arteries in patients undergoing peripheral MR angiography. MATERIALS AND METHODS: Data of 87 consecutive standardized peripheral MR angiographic examinations were retrospectively reviewed to determine contrast material arrival times to the common femoral artery (CFA), the popliteal and tibial arteries, and the corresponding veins. Travel times were correlated with clinical data obtained with retrospective chart review and predictive multiparameter models developed with stepwise linear regression. RESULTS: The mean travel time of contrast material to the CFA was 24 seconds +/- 6 (SD), with additional 5 seconds +/- 2 to reach the popliteal artery and 7 seconds +/- 4 to reach the ankle artery. The mean time window of arterial enhancement was 49 seconds +/- 10 in the pelvis, 45 seconds +/- 10 in the thigh, and 35 seconds +/- 14 in the calf. The travel time to CFA was correlated with aortic aneurysm (r = 0.41; P <.001), increasing age (r = 0.31; P =.003), male sex (r = 0.3; P =.005), myocardial infarction (r = 0.26; P =.016), and type 2 diabetes mellitus (r = -0.22; P =.041). Predicted travel time to CFA was 10.6 seconds, plus 0.143 seconds times patient age, plus 4.8 seconds if aneurysm was present, plus 3.8 seconds if male sex, plus 2.8 seconds if history of myocardial infarction. CONCLUSION: Contrast material injected intravenously traveled rapidly down the peripheral arteries at approximately 6 seconds per station, but a long arterial phase time window allowed bolus-chase peripheral MR angiography to function with slower table stepping. Patient-to-patient variations in contrast material kinetics may be anticipated on the basis of age, sex, and clinical parameters.

Adult↗