Richard Y Chiao

Publications and source records attributed to Richard Y Chiao.

3 recordsLinked to original sources

Coded excitation for diagnostic ultrasound: a system developer's perspective.

Resolution and penetration are primary criteria for clinical image quality. Conventionally, high bandwidth for resolution was achieved with a short pulse, which results in a tradeoff between resolution and penetration. Coded excitation extends the bounds of this tradeoff by increasing signal-to-noise ratio (SNR) through appropriate coding on transmit and decoding on receive. Although used for about 50 years in radar, coded excitation was successfully introduced into commercial ultrasound scanners only within the last 5 years. This delay is at least partly due to practical implementation issues particular to diagnostic ultrasound, which are the focus of this paper. After reviewing the basics of biphase and chirp coding, we present simulation results to quantify tradeoffs between penetration and resolution under frequency-dependent attenuation, dynamic focusing, and nonlinear propagation. Next we compare chirp and Golay code performance with respect to image quality and system requirements, then we show clinical images that illustrate the current applications of coded excitation in B-mode, harmonic, and flow imaging.

Computer Simulation↗

Echogenicity variations from porcine blood I: the "bright collapsing ring" under pulsatile flow.

The temporal and radial variations of the echogenicity from porcine blood were investigated using a linear M12L transducer with a GE LOGIQ 700 Expert system. The "bright collapsing ring" (BRCR) phenomenon, a bright echogenic ring converging from the periphery to the center of the tube wall and eventually collapsing during a pulsatile cycle in cross-sectional B-mode images, was observed from porcine blood in a mock flow loop within a 0.95-cm diameter tube under certain flow conditions. The BRCR phenomenon from porcine blood was stronger as the peak speed was increased from 10 to 25 cm/s, and the mean echogenicity and the "black hole" (BLH) phenomenon, a central echo-poor zone surrounded by a bright hyperechoic zone, became weaker. As stroke rate was increased from 20 to 60 beats/min (bpm), both the BRCR and the BLH phenomena became weaker. These two phenomena were observed at three transmitting frequencies (9, 11 and 13 MHz). As hematocrit was increased from 12 to 45%, the BRCR phenomenon became more apparent. The nonlinear behavior of backscatter as a function of hematocrit reaching a maximum at hematocrit of 10 approximately 20% was observed near the tube wall, but it changed at the center of the tube, indicating the importance of hemodynamics on the ultrasonic backscatter from flowing blood. The combined effects of shear rate and acceleration on red blood cell aggregation are suggested as a possible mechanism for these phenomena.

Animals↗

Echogenicity variations from porcine blood II: the "bright ring" under oscillatory flow.

Echogenicity variations from porcine blood were observed in a mock flow loop under pulsatile flow in a series of experiments (Paeng et al. 2004). In this paper, oscillatory flow was generated to further investigate the cyclic and radial variation of blood echogenicity and its origin and mechanisms by several parameters, including stroke volume, stroke rate, mean steady flow and transducer angle, using a GE LOGIQ 700 Expert system. The echogenicity at the center of the tube was enhanced during acceleration and lower during deceleration, and the expansion and collapse of the "bright ring" was observed twice per cycle. The "black hole," a central echo-poor zone surrounded by a hyperechoic zone, was barely observable under oscillatory flow, and these patterns differed from those under pulsatile flow. The cyclic and radial variation of echogenicity under oscillatory flow was affected by such hemodynamic parameters as stroke volume, stroke rate and mean steady flow. It was suggested that rouleaux might be aligned at an angle of about 25 degrees relative to the tube axis during the acceleration phase, based on the experimental results reaching a maximum of the echogenicity variation at a transducer angle of 25 degrees. Radial distribution of rouleaux alignments was proposed to be another important factor to blood echogenicity variation, in addition to combined effects of shear rate and flow acceleration on erythrocyte aggregation and blood echogenicity. The weak cyclic variation of echogenicity was also observed from the porcine erythrocyte suspensions under pure oscillatory flow, but not under pulsatile flow. It is postulated that the echogenicity variations from erythrocyte suspensions are from red cell deformation.

Animals↗