PubMed Health⌕ Search

Biomedical subjects

Rick C Sasso

Publications and source records attributed to Rick C Sasso.

20 records · Page 2Linked to original sources

The Bryan Cervical Disc: wear properties and early clinical results.

BACKGROUND CONTEXT: The rationale for motion preservation by disc replacement after anterior cervical discectomy is to diminish long-term morbidity secondary to adjacent segment degeneration. However, these disc prostheses will be subject to wear and its possible adverse consequences. PURPOSE: Assess the in vitro and in vivo wear properties of the Bryan Cervical Disc and the early clinical results. STUDY DESIGN: In vitro mechanical testing, caprine animal model and prospective European human trial. OUTCOME MEASURE: In vitro mechanical testing used American Society for Testing and Materials standards to measure wear rates and debris. Caprine results were analyzed by histopathologic analysis by a blinded veterinary pathologist. Clinical outcomes were measured by Odoms's criteria, independent radiologic analysis and Short Form-36. METHODS: In vitro wear testing in cervical spine simulator for up to 40 M cycles. Wear rates were determined and particles analyzed microscopically. The in vivo inflammatory response was studied in goats that had discectomy at C4-C5. They were sacrificed between 3 and 12 months and histopathologically were compared with controls who had fusions with titanium plates. A prospective clinical trial of 136 patients with minimum 1-year follow-up was analyzed using validated questionnaires and radiographs. RESULTS: In vitro wear averaged approximately 1.76% by weight at 10 M cycles and 18% at 40 M cycles. Wear debris were present in the periprosthetic tissues in 4 of 11 animals without inflammatory response. The early clinical results were satisfactory in over 90% of patients. CONCLUSION: The in vivo and in vitro wear properties are satisfactory for the expected duration of life of the prosthesis. The early clinical results are satisfactory and equal to fusion.

Animals↗

Percutaneous computer-assisted translaminar facet screw: an initial human cadaveric study.

BACKGROUND CONTEXT: Translaminar facet screws are a minimally invasive technique for posterior lumbar fixation with good success rates. Computer-assisted image navigation using virtual fluoroscopy allows multiple simultaneous screens in various planes to plan and drive spinal instrumentation. PURPOSE: This study evaluates the percutaneous placement of translaminar facet screws with the use of virtual fluoroscopy as an image guidance technique. STUDY DESIGN/SETTING: A human cadaveric study was performed with a percutaneous reference frame applied to the iliac crest. Ten translaminar facet screws were placed bilaterally at five levels. Anteroposterior and lateral images were used to navigate 4.0-mm screws through a percutaneous portal under virtual fluoroscopy. METHODS: An axial computed tomographic scan through the instrumented levels was obtained after the screws were placed. Screws were graded on entry, course through the lamina, and terminus. A grading system was devised to grade the course through the lamina. RESULTS: All 10 screw-entry points were judged optimal at the spinous process laminar junction. There were five Grade I breeches with less than 1/2 the screw through the lamina, and five Grade 0 screw placements with the screw contained completely within the lamina. The termination point was acceptable in five screws. The screws that began on the right and terminated on the left were all found to have grade II breakouts. No screws placed the spinal canal or exiting nerve root at risk. CONCLUSIONS: Virtual fluoroscopy provides significant assistance in percutaneous placement of translaminar facet screws and results in safe position of entry, lamina course, and terminus.

Bone Screws↗