PubMed Health⌕ Search

Biomedical subjects

Rihard Trebse

Publications and source records attributed to Rihard Trebse.

5 recordsLinked to original sources

Survivorship and retrieval analysis of Sikomet metal-on-metal total hip replacements at a mean of seven years.

BACKGROUND: Second-generation metal-on-metal total hip replacements were introduced in the early 1990s with the aim of eliminating polyethylene wear and the resulting complications of osteolysis and aseptic loosening. The goal of the present study was to evaluate the intermediate-term results in a series of patients who were managed with one of these implants. METHODS: Between 1994 and 2002, we performed 640 total hip replacements in 591 patients with use of a Bicon-Plus cementless threaded cup with a polyethylene liner housing a metal inlay made of Sikomet low-carbon cobalt-chromium-molybdenum alloy that articulates with a Sikomet metal femoral head. Clinical and radiographic evaluation was performed retrospectively at a mean of 7.1 years postoperatively. Histologic analysis was performed on specimens retrieved from seventeen hips that were revised, and wear measurements were made for six hips that were revised. RESULTS: Thirty-four hips (thirty-four patients) were revised because of infection (six hips), aseptic loosening (twenty-three hips), pain without loosening (two hips), or other reasons (three hips). The survival rate of the prosthesis as a whole at ten years, with revision for any reason as the end point, was 0.91 (95% confidence interval, 0.88 to 0.95). The survival rate of the cup was 0.94 (95% confidence interval, 0.90 to 0.97), and that of the stem was 0.96 (95% confidence interval, 0.94 to 0.98). Linear or expansile osteolysis, or both, was observed on the radiographs of sixteen (64%) of the twenty-five hips that were revised because of aseptic loosening and/or pain. Histological analysis of pericapsular tissue was performed for seventeen of the twenty-five hips that were revised because of aseptic loosening and/or pain. Thirteen of these seventeen hips demonstrated a hypersensitivity-like reaction with aseptic inflammatory changes accompanied by moderate to extensive diffuse and perivascular infiltration of lymphocytes. In the six retrieved specimens that were subjected to wear analysis, the main wear mode was abrasive wear. The mean cumulative linear wear for the bearing was 31.3 microm, and the mean annual wear rate was 6.3 microm/yr. The mean clearance was 87.6 microm. CONCLUSIONS: After a mean duration of follow-up of seven years, aseptic loosening was the major reason for failure of Sikomet metal-on-metal prostheses. The histological findings and the prevalence of osteolysis suggest the possibility of a hypersensitivity-like immunological response to wear particles.

Adolescent↗

Dissociation of the metal inlay from the polyethylene liner in an uncemented threaded cup.

We describe a case of spontaneous dissociation of the metal inlay from the polyethylene cup of a sandwiched metal-on-metal total hip prosthesis manufactured from Co-28Cr-6Mo SM 21 alloy. The patient, a 51-year-old active woman, started to feel groin pain 50 months postoperatively. The pain progressed after a slight trauma and led to final revision after 66 months in situ. No signs of impingement were observed. The polyethylene cup showed an approximately 2 mm-deep groove in the superior wall, and the head was heavily worn on the lateral side. In addition to the typically observed abrasive wear patterns, several types of severe wear defects were noticed. Extensive metallosis and necrosis were observed histologically. This unusual case of substantial deformation of the head and the cup was presumed to have occurred as a result of the increased friction and consequent high wear of the metal head.

Arthroplasty, Replacement, Hip↗

Poor results from the isoelastic total hip replacement: 14-17-year follow-up of 149 cementless prostheses.

BACKGROUND: To overcome the mismatch between a stiff stem and the more elastic bone, the concept of isoelasticity was introduced in the 1970s. This concept was based on the assumption that the implant and the bone should deform as one unit to avoid stress shielding. The Robert Mathys (RM) cementless total hip replacement (THR) was one of the earliest isoelastic designs. PATIENTS AND METHODS: From 1984 to 1987, we performed 149 total hip replacements in 135 patients (92 women, mean age 47 (21-72) years) using third-generation Mathys isoelastic polyacetal stem with stainless-steel heads and polyethylene cementless acetabular cups. 11 patients died before revision or before the examination for this study, and 14 were lost to follow-up. Average follow-up time for the remaining 110 patients was 15 (14-17) years. RESULTS: To date, 69 hips (64 patients) have been revised, 5 due to infection. The 10-year survival rate for any reason was 70% (66-74). In the 46 remaining patients (53 hips), the average HHS was 80 (39-100) points. 13 of these were regarded as radiographic failures, with an average HHS of 75 points. INTERPRETATION: The performance of this prosthesis was unacceptably poor. Higher debris production and poor primary fixation are believed to be the main reason for the high failure rate.

Acetabulum↗

Fifty-one-year survival of a Judet polymethylmethacrylate hip prosthesis.

Revision arthroplasty of a Judet polymethylmethacrylate (PMMA) hip hemiprosthesis was performed 51 years after implantation. This makes it the first implant to have survived for longer than 50 years. No signs of aggressive osteolysis were found on histologic analysis, which confirms good tissue tolerance for PMMA. Judet's hip prosthesis did not follow the concept of low-friction arthroplasty; nevertheless, it represents an important step in the development of the hip prosthesis currently used.

Aged↗