PubMed Health⌕ Search

Biomedical subjects

Rikiya Onimaru

Publications and source records attributed to Rikiya Onimaru.

At least 19 recordsLinked to original sources

Uncertainty in treatment of head-and-neck tumors by use of intraoral mouthpiece and embedded fiducials.

PURPOSE: To reduce setup error and intrafractional movement in head-and-neck treatment, a real-time tumor tracking radiotherapy (RTRT) system was used with the aid of gold markers implanted in a mouthpiece. METHODS AND MATERIALS: Three 2-mm gold markers were implanted into a mouthpiece that had been custom made for each patient before the treatment planning process. Setup errors in the conventional immobilization system using the shell (manual setup) and in the RTRT system (RTRT setup) were compared. Eight patients with pharyngeal tumors were enrolled. RESULTS: The systematic setup errors were 1.8, 1.6, and 1.1 mm in the manual setup and 0.2, 0.3, and 0.3 mm in the RTRT setup in right-left, craniocaudal, and AP directions, respectively. Statistically significant differences were observed with respect to the variances in setup error (p <0.001). The systematic and random intrafractional errors were maintained within the ranges of 0.2-0.6 mm and 1.0-2.0 mm, respectively. The rotational systematic and random intrafractional errors were estimated to be 2.2-3.2 degrees and 1.5-1.6 degrees , respectively. CONCLUSIONS: The setup error and planning target volume margin can be significantly reduced using an RTRT system with a mouthpiece and three gold markers.

Adult↗

Speed and amplitude of lung tumor motion precisely detected in four-dimensional setup and in real-time tumor-tracking radiotherapy.

BACKGROUND: To reduce the uncertainty of registration for lung tumors, we have developed a four-dimensional (4D) setup system using a real-time tumor-tracking radiotherapy system. METHODS AND MATERIALS: During treatment planning and daily setup in the treatment room, the trajectory of the internal fiducial marker was recorded for 1 to 2 min at the rate of 30 times per second by the real-time tumor-tracking radiotherapy system. To maximize gating efficiency, the patient's position on the treatment couch was adjusted using the 4D setup system with fine on-line remote control of the treatment couch. RESULTS: The trajectory of the marker detected in the 4D setup system was well visualized and used for daily setup. Various degrees of interfractional and intrafractional changes in the absolute amplitude and speed of the internal marker were detected. Readjustments were necessary during each treatment session, prompted by baseline shifting of the tumor position. CONCLUSION: The 4D setup system was shown to be useful for reducing the uncertainty of tumor motion and for increasing the efficiency of gated irradiation. Considering the interfractional and intrafractional changes in speed and amplitude detected in this study, intercepting radiotherapy is the safe and cost-effective method for 4D radiotherapy using real-time tracking technology.

Dose Fractionation, Radiation↗

Hypofractionated radiotherapy boost for dose escalation as a treatment option for high-grade spinal cord astrocytic tumor.

PURPOSE: To retrospectively analyze the outcome of post-operative radiotherapy for spinal cord glioma with the emphasis on the hypofractionated radiotherapy boost for dose escalation as a treatment option for high-grade spinal cord astrocytic tumors. MATERIALS AND METHODS: Forty-one patients with spinal cord glioma received post-operative radiotherapy between 1979 and 2003. The median age was 34 years (range, 10-66 years). Median follow-up was 49 months (range, 5-291 months). There were 12 low-grade astrocytic tumors, 11 high-grade astrocytic tumors, 16 low-grade ependymal tumors and 2 high-grade ependymal tumors. Among 11 patients with high-grade astrocytic tumors, 5 with anaplastic astrocytoma and 1 with glioblastoma received hypofractionated radiotherapy boost for dose escalation. The median total dose of the conventional radiotherapy was 45.5 Gy in 19 fractions (range, 30.0-60.0 Gy). The median normalized total dose (using daily dose of 2.0 Gy and an alpha/ per thousandbeta ratio of 2.0) of the hypofractionated radiotherapy boost was 131 Gy2 (range, 85-249). RESULTS: The Kaplan-Meier survival rates at 10 years from the date of the first surgery were 64% for the entire group, 47% for the astrocytic tumors and 84% for the ependymal tumors, respectively (P=0.009). Among 11 patients with high-grade astrocytic tumors, the actuarial survival rate at 10 years was 35%. The actuarial survival rates at 10 years were 67% for those who received hypofractionated radiotherapy boost for dose escalation, and 20% for those who did not (P=0.47). DISCUSSION: The results for ependymal tumors and low-grade astrocytic tumors were comparable to those reported in the literature. Hypofractionated radiotherapy boost for dose escalation may help to prolong the survival of patients with high-grade astrocytic tumors.

Adolescent↗

The effect of tumor location and respiratory function on tumor movement estimated by real-time tracking radiotherapy (RTRT) system.

PURPOSE: The effects of tumor location and pulmonary function on the motion of fiducial markers near lung tumors were evaluated to deduce simple guidelines for determining the internal margin in radiotherapy without fiducial markers. METHODS AND MATERIALS: Pooled data collected by a real-time tumor-tracking radiotherapy system on 42 markers in 39 patients were analyzed. The pulmonary functions of all patients were assessed before radiotherapy. Using chest X-ray film, the position of the marker was expressed relative to the geometry of the unilateral lung. Posterior location meant the area of the posterior half of the lung in a lateral chest X-ray film, and caudal location meant the caudal half of the chest X-ray film; these categories were determined by measuring the distance between the marker and anatomic landmarks, including the apex, costophrenic angle, midline of spinal canal, lateral, anterior, and posterior boundary of the lung. RESULTS: Before the radiotherapy, 18 patients had obstructive respiratory dysfunction (ratio of forced expiratory volume in 1 s to forced vital capacity [FEV1.0/FVC] <70), 5 patients had constrictive dysfunction (percent vital capacity [%VC] <80), and 3 had mixed dysfunction. Means of FEV1.0/FVC and %VC were 97.0% and 66.5%, respectively. Median tumor movements in the x (left-right), y (anteroposterior), and z (craniocaudal) directions were 1.1 mm, 2.3 mm, and 5.4 mm, respectively. There was no significant correlation between respiratory function and magnitude of marker movement in any direction. Median marker movement in the z direction was 2.6 mm for the cranial location and 11.8 mm for the caudal location, respectively (p < 0.001). Median movement in the z direction was 11.8 mm for posterior location and 3.4 mm for anterior location, respectively (p < 0.01). CONCLUSIONS: Simple measurement of the relative location on plain chest X-ray film was related, but respiratory function test was not related, to the craniocaudal amplitude of the motion of the fiducial marker near lung tumors.

Adult↗

Insertion and fixation of fiducial markers for setup and tracking of lung tumors in radiotherapy.

PURPOSE: Internal 1.5-mm fiducial markers were used in real-time tumor-tracking radiotherapy (RT) for lung cancer. The fixation rate of the markers using the bronchial insertion technique, reliability of the setup using markers around the target volume, dislocation of the markers after real-time tumor-tracking RT, and long-term toxicity of marker insertion were investigated. METHODS AND MATERIALS: Between July 2000 and April 2004, 154 gold markers were inserted into 57 patients with peripheral lung cancer. The distances between the implanted markers in 198 measurements in 71 set-ups in 11 patients were measured using two sets of orthogonal diagnostic X-ray images of the real-time tumor-tracking RT system. The distance between the markers and the chest wall was also measured in a transaxial CT image on 186 occasions in 48 patients during treatment planning and during follow-up. The median treatment time was 6 days (range, 4-14 days). RESULTS: In 115 (75%) of the 154 inserted markers, the gold marker was detected throughout the treatment period. In 122 markers detected at CT planning, 115 (94%) were detected until the end of treatment. The variation in the distances between the implanted markers was within +/-2 mm in 95% and +/-1 mm in 80% during treatment. The variation in the distances between the implanted markers was >2 mm in at least one direction in 9% of the setups for which reexamination with a CT scan was indicated. The fixation rate in the left upper lobe was lower than in the other lobes. A statistically significant relationship was found between a shorter distance between the markers and the chest wall and the fixation rate, suggesting that the markers in the smaller bronchial lumens fixed better than those in the larger lumens. A learning curve among the endoscopists was suggested in the fixation rate. The distance between the markers and the chest wall changed significantly within a median of 44 days (range, 16-181 days) after treatment. CONCLUSION: The fixation of markers into the bronchial tree was useful for the setup for peripheral lung cancer and had an accuracy of +/-2 mm during the 1-2-week treatment period. The relationship between the markers and tumor can change significantly after 2 weeks, suggesting that adaptive four-dimensional RT is required.

Adult↗

Three-dimensional conformal setup (3D-CSU) of patients using the coordinate system provided by three internal fiducial markers and two orthogonal diagnostic X-ray systems in the treatment room.

PURPOSE: To test the accuracy of a system for correcting for the rotational error of the clinical target volume (CTV) without having to reposition the patient using three fiducial markers and two orthogonal fluoroscopic images. We call this system "three-dimensional conformal setup" (3D-CSU). METHODS AND MATERIALS: Three 2.0-mm gold markers are inserted into or adjacent to the CTV. On the treatment couch, the actual positions of the three markers are calculated based on two orthogonal fluoroscopies crossing at the isocenter of the linear accelerator. Discrepancy of the actual coordinates of gravity center of three markers from its planned coordinates is calculated. Translational setup error is corrected by adjustment of the treatment couch. The rotation angles (alpha, beta, gamma) of the coordinates of the actual CTV relative to the planned CTV are calculated around the lateral (x), craniocaudal (y), and anteroposterior (z) axes of the planned CTV. The angles of the gantry head, collimator, and treatment couch of the linear accelerator are adjusted according to the rotation of the actual coordinates of the tumor in relation to the planned coordinates. We have measured the accuracy of 3D-CSU using a static cubic phantom. RESULTS: The gravity center of the phantom was corrected within 0.9 +/- 0.3 mm (mean +/- SD), 0.4 +/- 0.2 mm, and 0.6 +/- 0.2 mm for the rotation of the phantom from 0-30 degrees around the x, y, and z axes, respectively, every 5 degrees. Dose distribution was shown to be consistent with the planned dose distribution every 10 degrees of the rotation from 0-30 degrees. The mean rotational error after 3D-CSU was -0.4 +/- 0.4 (mean +/- SD), -0.2 +/- 0.4, and 0.0 +/- 0.5 degrees around the x, y, and z axis, respectively, for the rotation from 0-90 degrees. CONCLUSIONS: Phantom studies showed that 3D-CSU is useful for performing rotational correction of the target volume without correcting the position of the patient on the treatment couch. The 3D-CSU will be clinically useful for tumors in structures such as paraspinal diseases and prostate cancers not subject to large internal organ motion.

Humans↗

Hypofractionated stereotactic radiotherapy alone without whole-brain irradiation for patients with solitary and oligo brain metastasis using noninvasive fixation of the skull.

PURPOSE: To evaluate the efficacy and toxicity of hypofractionated stereotactic radiotherapy (HSRT) using noninvasive fixation of the skull on solitary or oligo brain metastatic patients as an alternative to stereotactic radiosurgery (SRS) using invasive fixation. PATIENTS AND METHODS: The subjects were 87 patients who had 4 or fewer brain metastases (50 solitary, 37 oligometastases). Treatment was conducted on 159 metastases by using a linac-based stereotactic system. The median isocentric dose was 35 Gy in 4 fractions. Whole-brain irradiation was not applied as an initial treatment. For the salvage treatment of metachronous brain metastases, repeat HSRT or whole-brain irradiation was applied. RESULTS: The actuarial 1-year local tumor control rate was 81%. Treatment-related complications were observed in 4 patients in the early period (<3 months) and in 2 patients in the late period. The median survival period was 8.7 months. Metachronous brain metastases occurred in 30 patients, and none of the 18 patients who were eligible for salvage HSRT refused to receive it again. CONCLUSIONS: Hypofractionated stereotactic radiotherapy achieved tumor control and survival equivalent to those of SRS reported in the literature. The results suggested that HSRT could be an alternative for solitary or oligo brain metastatic patients with less toxicity and less invasiveness compared to SRS.

Actuarial Analysis↗

Feasibility of insertion/implantation of 2.0-mm-diameter gold internal fiducial markers for precise setup and real-time tumor tracking in radiotherapy.

PURPOSE: To examine the feasibility and reliability of insertion of internal fiducial markers into various organs for precise setup and real-time tumor tracking in radiotherapy (RT). MATERIALS AND METHODS: Equipment and techniques for the insertion of 2.0-mm-diameter gold markers into or near the tumor were developed for spinal/paraspinal lesions, prostate tumors, and liver and lung tumors. Three markers were used to adjust the center of the mass of the target volume to the planned position in spinal/paraspinal lesions and prostate tumors (the three-marker method). The feasibility of the marker insertion and the stability of the position of markers were tested using stopping rules in the clinical protocol (i.e., the procedure was abandoned if 2 of 3 or 3 of 6 patients experienced marker dropping or migration). After the evaluation of the feasibility, the stability of the marker positions was monitored in those patients who entered the dose-escalation study. RESULTS: Each of the following was shown to be feasible: bronchoscopic insertion for the peripheral lung; image-guided transcutaneous insertion for the liver; cystoscopic and image-guided percutaneous insertion for the prostate; and surgical implantation for spinal/paraspinal lesions. Transcutaneous insertion of markers for spinal/paraspinal lesions and bronchoscopic insertion for central lung lesions were abandoned. Overall, marker implantation was successful and was used for real-time tumor tracking in RT in 90 (90%) of 100 lesions. No serious complications related to the marker insertion were noted for any of the 100 lesions. Using three markers surgically implanted into the vertebral bone, the mean +/- standard deviation in distance among the three markers was within 0.2 +/- 0.6 mm (range -1.4 to 0.8) through the treatment period of 30 days. The distance between the three markers gradually decreased during RT in five of six prostate cancers, consistent with a mean rate of volume regression of 9.3% (range 0.015-13%) in 10 days. CONCLUSIONS: Internal 2.0-mm-diameter gold markers can be safely inserted into various organs for real-time tumor tracking in RT using the prescribed equipment and techniques. The three-marker method has been shown to be a useful technique for precise setup for spinal/paraspinal lesions and prostate tumors.

Adenocarcinoma↗

Tumor location, cirrhosis, and surgical history contribute to tumor movement in the liver, as measured during stereotactic irradiation using a real-time tumor-tracking radiotherapy system.

PURPOSE: To investigate the three-dimensional (3D) intrafractional motion of liver tumors during real-time tumor-tracking radiotherapy (RTRT). MATERIALS AND METHODS: The data of 20 patients with liver tumors were analyzed. Before treatment, a 2-mm gold marker was implanted near the tumor. The RTRT system used fluoroscopy image processor units to determine the 3D position of the implanted marker. A linear accelerator was triggered to irradiate the tumor only when the marker was located within a permitted region. The automatically recorded tumor-motion data were analyzed to determine the amplitude of the tumor motion, curve shape of the tumor motion, treatment efficiency, frequency of movement, and hysteresis. Each of the following clinical factors was evaluated to determine its contribution to the amplitude of movement: tumor position, existence of cirrhosis, surgical history, tumor volume, and distance between the isocenter and the marker. RESULTS: The average amplitude of tumor motion in the 20 patients was 4 +/- 4 mm (range 1-12), 9 +/- 5 mm (range 2-19), and 5 +/- 3 mm (range 2-12) in the left-right, craniocaudal, and anterior-posterior (AP) direction, respectively. The tumor motion of the right lobe was significantly larger than that of the left lobe in the left-right and AP directions (p = 0.01). The tumor motion of the patients with liver cirrhosis was significantly larger than that of the patients without liver cirrhosis in the left-right and AP directions (p < 0.004). The tumor motion of the patients who had received partial hepatectomy was significantly smaller than that of the patients who had no history of any operation on the liver in the left-right and AP directions (p < 0.03). Thus, three of the five clinical factors examined (i.e., tumor position in the liver, cirrhosis, and history of surgery on the liver) significantly affected the tumor motion of the liver in the transaxial direction during stereotactic irradiation. Frequency analysis revealed that for 9 (45%) of the 20 tumors, the cardiac beat caused measurable motion. The 3D trajectory of the tumor showed hysteresis for 4 (20%) of the 20 tumors. The average treatment efficiency of RTRT was 40%. CONCLUSIONS: Tumor location, cirrhosis, and history of surgery on the liver all had an impact on the intrafractional tumor motion of the liver in the transaxial direction. This finding should be helpful in determining the smallest possible margin in individual cases of radiotherapy for liver malignancy.

Computer Systems↗

Tolerance of organs at risk in small-volume, hypofractionated, image-guided radiotherapy for primary and metastatic lung cancers.

PURPOSE: To determine the organ at risk and the maximum tolerated dose (MTD) of radiation that could be delivered to lung cancer using small-volume, image-guided radiotherapy (IGRT) using hypofractionated, coplanar, and noncoplanar multiple fields. MATERIALS AND METHODS: Patients with measurable lung cancer (except small-cell lung cancer) 6 cm or less in diameter for whom surgery was not indicated were eligible for this study. Internal target volume was determined using averaged CT under normal breathing, and for patients with large respiratory motion, using two additional CT scans with breath-holding at the expiratory and inspiratory phases in the same table position. Patients were localized at the isocenter after three-dimensional treatment planning. Their setup was corrected by comparing two linacographies that were orthogonal at the isocenter with corresponding digitally reconstructed images. Megavoltage X-rays using noncoplanar multiple static ports or arcs were used to cover the parenchymal tumor mass. Prophylactic nodal irradiation was not performed. The radiation dose was started at 60 Gy in 8 fractions over 2 weeks (60 Gy/8 Fr/2 weeks) for peripheral lesions 3.0 cm or less, and at 48 Gy/8 Fr/2 weeks at the isocenter for central lesions or tumors more than 3.0 cm at their greatest dimension. RESULTS: Fifty-seven lesions in 45 patients were treated. Tumor size ranged from 0.6 to 6.0 cm, with a median of 2.6 cm. Using the starting dose, 1 patient with a central lesion died of a radiation-induced ulcer in the esophagus after receiving 48 Gy/8 Fr at isocenter. Although the contour of esophagus received 80% or less of the prescribed dose in the planning, recontouring of esophagus in retrospective review revealed that 1 cc of esophagus might have received 42.5 Gy, with the maximum dose of 50.5 Gy. One patient with a peripheral lesion experienced Grade 2 pain at the internal chest wall or visceral pleura after receiving 54 Gy/8 Fr. No adverse respiratory reaction was noted in the symptoms or respiratory function tests. The 3-year local control rate was 80.4% +/- 7.1% (a standard error) with a median follow-up period of 17 months for survivors. Because of the Grade 5 toxicity, we have halted this Phase I/II study and are planning to rearrange the protocol setting accordingly. The 3-year local control rate was 69.6 +/- 10.6% for patients who received 48 Gy and 100% for patients who received 60 Gy (p = 0.0442). CONCLUSIONS: Small-volume IGRT using 60 Gy in eight fractions is highly effective for the local control of lung tumors, but MTD has not been determined in this study. The organs at risk are extrapleural organs such as the esophagus and internal chest wall/visceral pleura rather than the pulmonary parenchyma in the present protocol setting. Consideration of the uncertainty in the contouring of normal structures is critically important, as is uncertainty in setup of patients and internal organ in the high-dose hypofractionated IGRT.

Adult↗

Management of vestibular schwannoma by fractionated stereotactic radiotherapy and associated cerebrospinal fluid malabsorption.

OBJECT: The goal of this study was to investigate outcomes in patients with vestibular schwannoma (VS) who were treated with fractionated stereotactic radiotherapy (SRT). METHODS: One hundred one patients with VS were treated with fractionated SRT at a radiation level of 40 to 50 Gy administered in 20 to 25 fractions over a 5- to 6-week period. The median tumor size in these patients was 19 mm (range 3-40 mm), and 27 tumors were larger than 25 mm. Patients were consistently followed up using magnetic resonance imaging every 6 months for 5 years in principle. The median follow-up period was 45 months. The actuarial 5-year rate of tumor control (no growth > 2 mm and no requirement for salvage surgery) was 91.4% (95% confidence interval 85.2-97.6%). Three patients with progressive tumors underwent salvage tumor resection. The actuarial 5-year rate of useful hearing preservation (Gardner-Robertson Class I or II) was 71%. The observed complications of fractionated SRT included transient facial nerve palsy (4% of patients), trigeminal neuropathy (14% of patients), and balance disturbance (17% of patients). No new permanent facial weakness occurred after fractionated SRT. Eleven patients (11%) who had progressive communicating hydrocephalus (cerebrospinal fluid malabsorption) and no evidence of tumor growth after fractionated SRT required a shunt. The symptoms of this type of hydrocephalus were similar to those of normal-pressure hydrocephalus and occurred 4 to 20 months (median 12 months) after fractionated SRT. The mean size (+/- standard deviation) of tumors causing symptomatic hydrocephalus (25.5 +/- 7.8 mm) was significantly larger than that of other tumors (18.2 +/- 8.7 mm) (p = 0.011). Only four of the 72 patients with tumors smaller than 25 mm in maximum diameter received a shunt. CONCLUSIONS: Fractionated SRT resulted in an excellent tumor control rate, even for relatively large tumors, and produced a high rate of hearing preservation that was comparable to the best results of single-fraction radiosurgery. The progression of communicating hydrocephalus should be monitored closely, particularly in patients harboring a large VS.

Adolescent↗

Focal fractionated radiotherapy for intramedullary spinal arteriovenous malformations: 10-year experience.

OBJECT: Radiosurgical treatment of spinal arteriovenous malformations (AVMs) is becoming a practical therapeutic option as methodology improves, but no comparative study has yet been published on focal fractionated radiotherapy. The authors report their experience with conventional and hypofractionated radiotherapy for spinal AVM. METHODS: Candidates for this study were patients who experienced symptoms due to an intramedullary AVM but were ineligible for embolization or surgery. Of 21 patients with spinal AVMs, 10 cases in a 10-year period met this criterion. Angiography and contrast-enhanced computerized tomography scanning were used for treatment planning in all cases. Fractionated radiotherapy was performed using a linear accelerator, extracranial immobilization system, and frequent orthogonal linacographic verification. The starting radiation dose was 32 Gy in two, 36 Gy in three, and 40 Gy in two patients, in a regimen involving 1.8 to 2-Gy daily fractions; this was recently changed to a hypofractionation schedule of 30 Gy (in eight sessions) in one and 20 Gy (in four sessions) in two patients. RESULTS: The follow-up period ranged from 26 to 124 months (median of 49 months). There were no hemorrhages nor any adverse reactions attributable to irradiation. Of the seven patients who consented to undergo follow-up angiography, the nidus size decreased in five, but complete obliteration did not occur in any patient. CONCLUSIONS: Because no patient experienced adverse effects, the maximum tolerable radiation dose for the spinal cord associated with an AVM could not be identified, although it presumably is higher than those administered. The lack of rebleeding in patients in whom complete angiographic occlusion was absent suggests that the natural history of spinal AVMs may be less aggressive than previously reported.

Adolescent↗

Calculation of rotational setup error using the real-time tracking radiation therapy (RTRT) system and its application to the treatment of spinal schwannoma.

PURPOSE: The efficacy of a prototypic fluoroscopic real-time tracking radiation therapy (RTRT) system using three gold markers (2 mm in diameter) for estimating translational error, rotational setup error, and the dose to normal structures was tested in 5 patients with spinal schwannoma and a phantom. METHODS AND MATERIALS: Translational error was calculated by comparing the actual position of the marker closest to the tumor to its planned position, and the rotational setup error was calculated using the three markers around the target. Theoretically, the actual coordinates can be adjusted to the planning coordinates by sequential rotation of gamma degrees around the z axis, beta degrees around the y axis, and alpha degrees around the x axis, in this order. We measured the accuracy of the rotational calculation using a phantom. Five patients with spinal schwannoma located at a minimum of 1-5 mm from the spinal cord were treated with RTRT. Three markers were inserted percutaneously into the paravertebral deep muscle in 3 patients and surgically into two consecutive vertebral bones in two other patients. RESULTS: In the phantom study, the discrepancies between the actual and calculated rotational error were -0.1 +/- 0.5 degrees. The random error of rotation was 5.9, 4.6, and 3.1 degrees for alpha, beta, and gamma, respectively. The systematic error was 7.1, 6.6, and 3.0 degrees for alpha, beta, and gamma, respectively. The mean rotational setup error (0.2 +/- 2.2, -1.3 +/- 2.9, and -1.3 +/- 1.7 degrees for alpha, beta, and gamma, respectively) in 2 patients for whom surgical marker implantation was used was significantly smaller than that in 3 patients for whom percutaneous insertion was used (6.0 +/- 8.2, 2.7 +/- 5.9, and -2.1 +/- 4.6 degrees for alpha, beta, and gamma). Random translational setup error was significantly reduced by the RTRT setup (p < 0.0001). Systematic setup error was significantly reduced by the RTRT setup only in patients who received surgical implantation of the marker (p < 0.0001). The maximum dose to the spinal cord was estimated to be 40.6-50.3 Gy after consideration of the rotational setup error, vs. a planned maximum dose of 22.4-51.6 Gy. CONCLUSION: The RTRT system employing three internal fiducial markers is useful to reduce translational setup error and to estimate the dose to the normal structures in consideration of the rotational setup error. Surgical implantation of the marker to the vertebral bone was shown to be sufficiently rigid for the calculation of the rotational setup error. Fractionated radiotherapy for spinal schwannoma using the RTRT system may well be an alternative or supplement to surgical treatment.

Adolescent↗

Real-time tumor-tracking radiation therapy for lung carcinoma by the aid of insertion of a gold marker using bronchofiberscopy.

BACKGROUND: The authors developed fluoroscopic real-time tumor-tracking radiation therapy (RTRT) by insertion of a gold marker using bronchofiberscopy to reduce uncertainties in organ motion and set-up error in external radiotherapy for moving tumors. The purpose of the current study was to evaluate RTRT's feasibility in lung carcinoma treatment. METHODS: The three-dimensional position of a 1.0-2.0 mm gold marker in or near the tumor was detected by two sets of fluoroscopies every 0.03 seconds. The treatment beam was gated to irradiate the tumor only when the position of the marker coincided with its planned position using the RTRT system. Bronchofiberscopic equipment for insertion of the marker into the lung tumor was developed and used for 20 lung tumors in 18 patients. Patients were given high dose hypofractionated focal irradiation (35-48 Gy in 4-8 fractions in 4-10 days) with a planning target volume margin of 5 mm for the tumor. RESULTS: The markers were successfully inserted and maintained at the inserted position during and after the radiotherapy in 14 (88%) of 16 peripheral-type lung tumors and in none of four central-type lung tumors, indicating that this method of RTRT was not feasible for central-type lung tumors. Tracking of the marker was successfully performed in 1 of 2 tumors with a 1.0 mm marker and in all of 12 tumors with a 1.5-2.0 mm marker. On the whole, 13 (65%) of the 20 tumors were successfully treated with RTRT. Local tumor control was achieved and maintained for all 12 patients (13 tumors), who were treated with RTRT, with a median followup of 9 months (range, 5-15). Localized radiation pneumonitis was found radiographically at the lung volume that was irradiated with about 20 Gy, without symptoms in all but one patient. CONCLUSIONS: The insertion of a gold marker into or near peripheral-type lung tumors using bronchofiberscopy is a feasible and safe technique. Excellent initial response and low incidence of clinical complications suggest that the high dose hypofractionated focal irradiation using the RTRT system can be a good local treatment for peripheral-type lung tumors.

Adult↗

Small-volume image-guided radiotherapy using hypofractionated, coplanar, and noncoplanar multiple fields for patients with inoperable Stage I nonsmall cell lung carcinomas.

BACKGROUND: Occasionally, medically compromised and/or elderly patients with nonsmall cell lung carcinomas (NSCLCs) cannot be treated surgically. We investigated small-volume hypofractionated image-guided radiotherapy (IGRT) without the need for breath control in patients with inoperable Stage I NSCLCs. METHODS: Between September 1996 and September 1999, 22 patients with Stage I NSCLCs, including 19 males and 3 females, were treated with IGRT. Among these patients, there were 13 Stage IA and 9 Stage IB tumors. The tumors ranged in size from 14.2 to 58.5 mm, with a median size of 26.7 mm. Of the 22 patients, 19 were unfit for surgical treatment due to poor pulmonary function, complications, and/or advanced age and 3 refused surgery. Computed tomographic scans (CT) of the primary tumor were taken during three respiratory phases and they were analyzed to determine the planning target volume, which included only the primary tumor with allowances for respiratory movement. The radiation doses administered at the edge of the moving tumor during normal breathing were 80% of the prescribed dose, either 48 or 60 Gy given in eight fractions over 2 weeks. Clinical evaluation, chest CT scan, and pulmonary function tests were performed before irradiation and at regular intervals for the post-IGRT follow-up. The median follow-up period was 24 months (range, 2-44 months; mean, 21.8 months) (at least 24 months for survivors). RESULTS: Of 17 tumors assessed at the initial follow-up 2-6 months after treatment (5 complete responses, 11 partial responses, and 1 progressive disease), 16 (94%) were controlled locally. One local recurrence was observed during the follow-up. The lung carcinoma-specific survival rate at 1 year was 94% and the 1-year actuarial recurrence-free survival rate was 71%. The lung carcinoma-specific survival rate at 2 years was 73% and the 2-year actuarial recurrence-free survival rate was 67%. The treatment was well tolerated and no major side effects were observed. Localized radiation pneumonitis was observed in all patients who were examined by CT scan, but the patients were asymptomatic. Parameters of pulmonary function, including vital capacity, total lung capacity, and diffusion capacity for carbon monoxide, decreased very little or not at all, indicating that IGRT rarely deteriorated pulmonary functions. CONCLUSIONS: Small-volume hypofractionated IGRT without breath control is a feasible and beneficial method for the curative treatment of patients with Stage I NSCLCs. It has the potential of a high local tumor control rate and low morbidity.

Aged↗

Three-dimensional intrafractional movement of prostate measured during real-time tumor-tracking radiotherapy in supine and prone treatment positions.

PURPOSE: To quantify three-dimensional (3D) movement of the prostate gland with the patient in the supine and prone positions and to analyze the movement frequency for each treatment position. METHODS AND MATERIALS: The real-time tumor-tracking radiotherapy (RTRT) system was developed to identify the 3D position of a 2-mm gold marker implanted in the prostate 30 times/s using two sets of fluoroscopic images. The linear accelerator was triggered to irradiate the tumor only when the gold marker was located within the region of the planned coordinates relative to the isocenter. Ten patients with prostate cancer treated with RTRT were the subjects of this study. The coordinates of the gold marker were recorded every 0.033 s during RTRT in the supine treatment position for 2 min. The patient was then moved to the prone position, and the marker was tracked for 2 min to acquire data regarding movement in this position. Measurements were taken 5 times for each patient (once a week); a total of 50 sets for the 10 patients was analyzed. The raw data from the RTRT system were filtered to reduce system noise, and the amplitude of movement was then calculated. The discrete Fourier transform of the unfiltered data was performed for the frequency analysis of prostate movement. RESULTS: No apparent difference in movement was found among individuals. The amplitude of 3D movement was 0.1-2.7 mm in the supine and 0.4-24 mm in the prone positions. The amplitude in the supine position was statistically smaller in all directions than that in the prone position (p < 0.0001). The amplitude in the craniocaudal and AP directions was larger than in the left-right direction in the prone position (p < 0.0001). No characteristic movement frequency was detected in the supine position. The respiratory frequency was detected for all patients regarding movement in the craniocaudal and AP directions in the prone position. The results of the frequency analysis suggest that prostate movement is affected by the respiratory cycle and is influenced by bowel movement in the prone position. CONCLUSION: The results of this study have confirmed that internal organ motion is less frequent in the supine position than in the prone position in the treatment of prostate cancer. RTRT would be useful in reducing uncertainty due to the effects of the respiratory cycle, especially in the prone position.

Fluoroscopy↗

Registration accuracy and possible migration of internal fiducial gold marker implanted in prostate and liver treated with real-time tumor-tracking radiation therapy (RTRT).

BACKGROUND AND PURPOSE: We have developed a linear accelerator synchronized with a fluoroscopic real-time tumor-tracking system to reduce errors due to setup and organ motion. In the real-time tumor-tracking radiation therapy (RTRT) system, the accuracy of tumor tracking depends on the registration of the marker's coordinates. The registration accuracy and possible migration of the internal fiducial gold marker implanted into prostate and liver was investigated. MATERIALS AND METHODS: Internal fiducial gold markers were implanted in 14 patients with prostate cancer and four patients with liver tumors. Computed tomography (CT) was carried out as a part of treatment planning in the 18 patients. A total of 72 follow-up CT scans were taken. We calculated the relative relationship between the coordinates of the center of mass (CM) of the organs and those of the marker. The discrepancy in the CM coordinates during a follow-up CT compared to those recorded during the planning CT was used to study possible marker migration. RESULTS: The standard deviation (SD) of interobserver variations in the CM coordinates was within 2.0 and 0.4 mm for the organ and the marker, respectively, in seven observers. Assuming that organs do not shrink, grow, or rotate, the maximum SD of migration error in each direction was estimated to be less than 2.5 and 2.0 mm for liver and prostate, respectively. There was no correlation between the marker position and the time after implantation. CONCLUSION: The degree of possible migration of the internal fiducial marker was within the limits of accuracy of the CT measurement. Most of the marker movement can be attributed to the measurement uncertainty, which also influences registration in actual treatment planning. Thus, even with the gold marker and RTRT system, a planning target volume margin should be used to account for registration uncertainty.

Carcinoma, Hepatocellular↗

Three-dimensional conformal radiotherapy for astrocytic tumors involving the eloquent area in children and young adults.

PURPOSE: Although a gross total removal of astrocytic tumors offers a favorable prognosis, it is often difficult to achieve in the eloquent area of the brain. This study was conducted to investigate the possible gain of three-dimensional conformal radiotherapy (3DCRT) for astrocytic tumors located in the eloquent area in children and young adults. MATERIALS AND METHODS: Twenty patients with astrocytic tumors received the radiotherapy. The median age was 17 years, ranging from 4 to 30 years. Fourteen low-grade tumors (seven pilocytic and seven diffuse), and six high-grade tumors (five anaplastic, one malignant pilocytic) were included. Tumors were located at the thalamus/hypothalamus in 12 cases, optic tract in one case, and the deep cerebral/cerebellar hemisphere in seven cases. A specific fixation device was used for 3DCRT. Forty-six Gy for low-grade tumors and 54 Gy for high-grade astrocytomas with 1.8-2.0 Gy per fraction were in principle employed as the standard regimen. Nominal radiotherapy fields ranged from 2.0 x 2.0 to 15.0 x 11.0 cm2. The median follow-up period was 42 months, ranging from 3 to 108 months. RESULTS: The actuarial survival rate at 5 years was 68% +/- 13% for all patients. The actuarial survival rate for low-grade glioma was 79% +/- 14% at 5 years and 50% +/- 20% at 3 years for high-grade glioma. The actual progression-free survival rate was 83% +/- 11% at 5 years for low-grade glioma and 50% +/- 20% for high-grade glioma. A complete response was obtained in three (21%) of 14 patients with low-grade astrocytic tumors. Two patients with low-grade tumors and four of six with high-grade tumors died due to tumor progression with infield relapse but not marginal relapse. Twelve survivors with low-grade tumors showed no signs of relapse and no neurological, hormonal, or cognitive deterioration after radiotherapy and were able to attend their school or continue with a full-time job. CONCLUSIONS: 3DCRT is safe and effective for low-grade astrocytic tumors located in the eloquent area in children and young adults.

Adolescent↗