PubMed Health⌕ Search

Biomedical subjects

Risto Kostiainen

Publications and source records attributed to Risto Kostiainen.

At least 19 recordsLinked to original sources

Polycyclic aromatic hydrocarbon (PAH) metabolizing enzyme activities in human lung, and their inducibility by exposure to naphthalene, phenanthrene, pyrene, chrysene, and benzo(a)pyrene as shown in the rat lung and liver.

In order to survey changes and activities in the polycyclic aromatic hydrocarbon (PAH)-metabolizing enzymes implicated in lung cancer susceptibility studies, we investigated enzyme induction by 2-5-ring-sized 'biomarker' PAHs in rat liver and lung, and the activities in five human lung specimens. Naphthalene, phenanthrene, pyrene, chrysene, and benzo[a]pyrene (BaP) were administered to rats for 3 days (25-128 mg/kg/day) and the responses compared with those of model inducers. PAH treatment increased the CYP1A-catalyzed activity of pyrene 1-hydroxylation and 7-ethoxyresorufin O-deethylation in rat liver by up to 28- and 279-fold, and in rat lung by up to 22- and 51-fold, respectively. 1-Naphthol (hUGT1A6), 1-hydroxypyrene (hUGT1A6/1A9), and entacapone (hUGT1A9) are markers of PAH-glucuronidating human uridine diphosphate-glucuronosyltransferases (UGT). These activities increased up to 6.4-fold in rat liver and up to 1.9-fold in rat lung. NADPH:quinone oxidoreductase 1 (NQO1) and glutathione S-transferase activities increased up to 5.3- and 1.6-fold (liver), and up to 4.4- and 1.4-fold (lung), respectively. CYP1A showed the best liver-to-lung relationship (R (2 )=( )0.90). The inducing efficiency by PAHs differed extensively: control 60-fold), many times greater than the experimental (inducible/constitutive) variation in the rat. Kinetics of 1-hydroxypyrene glucuronidation showed two low-K (m) forms both in rat and human lung. Since the 2-4-ring PAHs (major constituents) were poor enzyme inducers, it appears that the PAH-metabolizing pathways are mainly induced by BaP-type minor constituents. Gene-environmental interactions which magnify polymorphic variability in pulmonary bioactivation/detoxification capacity probably play a key role in individual susceptibility to (or protection against) chemically induced lung cancer. Hence, human exposure to PAH mixtures with high content of BaP-type hydrocarbons confers a potentially higher health risk than PAH mixtures with low content of procarcinogens.

Animals↗

Evaluation of cocktail approach to standardise Caco-2 permeability experiments.

The purpose of this study was to investigate the suitability and reliability of n-in-one approach using FDA suggested compounds for standardising Caco-2 permeability experiments. Special attention was paid to the evaluation of rank order correlation and mechanistic insights of compound permeability. Transport studies with antipyrine, metoprolol, ketoprofen, verapamil, hydrochlorothiazide, ranitidine, mannitol and fluorescein were performed in 12- and 24-well formats, as single compounds and in cocktails under iso-pH 7.4 and pH-gradient (pH 5.5 vs. 7.4) conditions. Compounds were quantified using n-in-one LC/MS/MS analysis. The cocktail-dosing proved to be a feasible method to determine the permeability of the Caco-2 cell line and to introduce external standards for permeability tests. Even though sink conditions were lost in cocktail experiments for highly permeable compounds, the rank order of compound permeability and the classification to low and high permeability compounds remained unchanged between single and cocktail studies and permeability values of 12- and 24-well formats were directly comparable. Under pH-gradient conditions the margin between high and low permeability compounds was narrower due to the lower permeability (higher fraction of ionisation) of basic molecules. Of the compounds studied, antipyrine, metoprolol, hydrochlorothiazide and mannitol are suitable for evaluation and standardisation purposes of passive permeability, while fluorescein would function as paracellular marker under iso-pH 7.4. As efflux activity may vary between cell batches, verapamil is a useful marker for P-glycoprotein.

Biological Transport, Active↗

Prominent but reverse stereoselectivity in propranolol glucuronidation by human UDP-glucuronosyltransferases 1A9 and 1A10.

Propranolol is a nonselective beta-adrenergic blocker used as a racemic mixture in the treatment of hypertension, cardiac arrhythmias, and angina pectoris. For study of the stereoselective glucuronidation of this drug, the two propranolol glucuronide diastereomers were biosynthesized, purified, and characterized. A screen of 15 recombinant human UDP-glucuronosyltransferases (UGTs) indicated that only a few isoforms catalyze propranolol glucuronidation. Analysis of UGT2B4 and UGT2B7 revealed no significant stereoselectivity, but these two enzymes differed in glucuronidation kinetics. The glucuronidation kinetics of R-propranolol by UGT2B4 exhibited a sigmoid curve, whereas the glucuronidation of the same substrate by UGT2B7 was inhibited by substrate concentrations above 1 mM. Among the UGTs of subfamily 1A, UGT1A9 and UGT1A10 displayed high and, surprisingly, opposite stereoselectivity in the glucuronidation of propranolol enantiomers. UGT1A9 glucuronidated S-propranolol much faster than R-propranolol, whereas UGT1A10 exhibited the opposite enantiomer preference. Nonetheless, the Km values for the two enantiomers, both for UGT1A9 and for UGT1A10, were in the same range, suggesting similar affinities for the two enantiomers. Unlike UGT1A9, the expression of UGT1A10 is extrahepatic. Hence, the reverse stereoselectivity of these two UGTs may signify specific differences in the glucuronidation of propranolol enantiomers between intestine and liver microsomes. Subsequent experiments confirmed this hypothesis: human liver microsomes glucuronidated S-propranolol faster than R-propranolol, whereas human intestine microsomes glucuronidated S-propranolol faster. These findings suggest a contribution of intestinal UGTs to drug metabolism, at least for UGT1A10 substrates.

Adrenergic beta-Antagonists↗

Gas chromatography-microchip atmospheric pressure chemical ionization-mass spectrometry.

An atmospheric pressure chemical ionization (APCI) microchip is presented for combining a gas chromatograph (GC) to a mass spectrometer (MS). The chip includes capillary insertion channel, stopper, vaporizer channel, nozzle and nebulizer gas inlet fabricated on the silicon wafer, and a platinum heater sputtered on a glass wafer. These two wafers are joined by anodic bonding creating a two-dimensional version of an APCI microchip. The sample from GC is directed via heated transfer line capillary to the vaporizer channel of the APCI chip. The etched nozzle forms narrow sample plume, which is ionized by an external corona discharge needle, and the ions are analyzed by a mass spectrometer. The GC-microchip APCI-MS combination provides an efficient method for qualitative and quantitative analysis. The spectra produced by microchip APCI show intensive protonated molecule and some fragmentation products as in classical chemical ionization for structure elucidation. In quantitative analysis the GC-microchip APCI-MS showed good linearity (r(2) = 0.9989) and repeatability (relative standard deviation 4.4%). The limits of detection with signal-to-noise ratio of three were between 0.5 and 2 micromol/L with MS mode using selected ion monitoring and 0.05 micromol/L with MS/MS using multiple reaction monitoring.

Anisoles↗

Capillary liquid chromatography-microchip atmospheric pressure chemical ionization-mass spectrometry.

A miniaturized nebulizer chip for capillary liquid chromatography-atmospheric pressure chemical ionization-mass spectrometry (capillary LC-microchip APCI-MS) is presented. The APCI chip consists of two wafers, a silicon wafer and a Pyrex glass wafer. The silicon wafer has a DRIE etched through-wafer nebulizer gas inlet, an edge capillary insertion channel, a stopper, a vaporizer channel and a nozzle. The platinum heater electrode and pads for electrical connection were patterned on to the Pyrex glass wafer. The two wafers were joined by anodic bonding, creating a microchip version of an APCI-source. The sample inlet capillary from an LC column is directly connected to the vaporizer channel of the APCI chip. The etched nozzle in the microchip forms a narrow sample plume, which is ionized by an external corona needle, and the formed ions are analyzed by a mass spectrometer. The nebulizer chip enables for the first time the use of low flow rate separation techniques with APCI-MS. The performance of capillary LC-microchip APCI-MS was tested with selected neurosteroids. The capillary LC-microchip APCI-MS provides quantitative repeatability and good linearity. The limits of detection (LOD) with a signal-to-noise ratio (S/N) of 3 in MS/MS mode for the selected neurosteroids were 20-1000 fmol (10-500 nmol l(-1)). LODs (S/N = 3) with commercial macro APCI with the same compounds using the same MS were about 10 times higher. Fast heat transfer allows the use of the optimized temperature for each compound during an LC run. The microchip APCI-source provides a convenient and easy method to combine capillary LC to any API-MS equipped with an APCI source. The advantages and potentials of the microchip APCI also make it a very attractive interface in microfluidic APCI-MS.

Atmospheric Pressure↗

Fractionation of polyphenols in hawthorn into polymeric procyanidins, phenolic acids and flavonoids prior to high-performance liquid chromatographic analysis.

Polymeric procyanidins, phenolic carboxylic acids and flavonoids of hawthorn (Crataegus laevigata) were fractionated prior to HPLC analysis using column chromatography and solid-phase extraction (SPE). The flavonoid fraction also contained (-)-epicatechin. The three groups of phenolics, each with clearly different UV spectra, were examined by means of high-performance liquid chromatography-diode array detection (HPLC-DAD) analysis. The average repeatability of the method (RSD) was in the range of 8-13% for chlorogenic acid, (-)-epicatechin and hyperoside. The polymeric procyanidins of hawthorn flowers consisted mainly of (-)-epicatechin subunits, and their mean degree of polymerization (DP) was 22.2. The HPLC methods developed can be used for the qualitative and quantitative analysis of different phenolic compounds in hawthorn plant material and their extracts.

Chemical Fractionation↗

Metabolite profile of sibutramine in human urine: a liquid chromatography-electrospray ionization mass spectrometric study.

We present a detailed experimental approach to detection and subsequent structural characterization of unknown metabolites of sibutramine, using liquid chromatography-mass spectrometric techniques. The full-, precursor ion, and constant neutral loss scan modes of a triple quadrupole mass spectrometer were used for screening sibutramine metabolites in human urine. The structural assessment of unknown metabolites was based on MSn ion trap mass spectrometric analysis and comparison of MSn spectra between the standards and compounds detected. Two phase-I (M1 and M2) and eight phase-II (M3-M6) metabolites of sibutramine were found in human urine. Metabolites M1 and M2, which were found as minor metabolites, originated from N-demethylation of sibutramine. Carbamoyl glucuronides formed from metabolites M1, M2, and their hydroxylated analogs were the main metabolites of sibutramine and were characterized by tandem mass spectrometric analysis and by the chemical modification of their structure. We demonstrate the usefulness of the chemical derivatization approach for estimation of the site of glucuronidation and propose the formation of hydroxylated regioisomers of metabolites M4 and M6.

Adult↗

Desorption electrospray ionization mass spectrometry for the analysis of pharmaceuticals and metabolites.

The performance of desorption electrospray ionization (DESI) in the analysis of a group of pharmaceuticals and their glucuronic acid conjugates is reported. The suitability of different sprayer solvents and different surfaces was examined. In the positive ion mode, water/methanol/trifluoroacetic acid performed best, whereas, in the negative ion mode, water/methanol/ammonium hydroxide was found to be the most suitable spray solvent. Of the surfaces investigated, polymethylmethacrylate (PMMA) was found to give the best performance in terms of sensitivity. Spray solution flow rate and the distance of the sprayer tip from the surface were also found to have significant effects on the signal intensity. Analytes with basic groups efficiently formed the corresponding protonated molecules in the positive ion mode, whereas acidic analytes, such as the glucuronic acid conjugates, formed intense signals due to the deprotonated molecules in the negative ion mode. Ionization of neutral compounds was less efficient and in many cases it was achieved through adduct formation with simple anions or cations.

Molecular Structure↗

Feasibility of different mass spectrometric techniques and programs for automated metabolite profiling of tramadol in human urine.

The purpose of the study was to determine the advantages of different mass spectrometric instruments and commercially available metabolite identification programs for metabolite profiling. Metabolism of tramadol hydrochloride and the excretion of it and its metabolites into human urine were used as a test case because the metabolism of tramadol is extensive and well known. Accurate mass measurements were carried out with a quadrupole time-of-flight mass spectrometer (Q-TOF) equipped with a LockSpray dual-electrospray ionization source. A triple quadrupole mass spectrometer (QqQ) was applied for full scan, product ion scan, precursor ion scan and neutral loss scan measurements and an ion trap instrument for full scan and product ion measurements. The performance of two metabolite identification programs was tested. The results showed that metabolite programs are time-saving tools but not yet capable of fully automated metabolite profiling. Detection of non-expected metabolites, especially at low concentrations in a complex matrix, is still almost impossible. With low-resolution instruments urine samples proved to be challenging even in a search for expected metabolites. Many false-positive hits were obtained with the automated searching and manual evaluation of the resulting data was required. False positives were avoided by using the higher mass accuracy Q-TOF. Automated programs were useful for constructing product ion methods, but the time-consuming interpretation of mass spectra was done manually. High-quality MS/MS spectra acquired on the QqQ instrument were used for confirmation of the tramadol metabolites. Although the ion trap instrument is of undisputable benefit in MS(n), the low mass cutoff of the ion trap made the identification of tramadol metabolites difficult. Some previously unreported metabolites of tramadol were found in the tramadol urine sample, and their identification was based solely on LC/MS and LC/MS/MS measurements.

Adult↗

New surfaces for desorption electrospray ionization mass spectrometry: porous silicon and ultra-thin layer chromatography plates.

The performance of nanoporous silicon (pSi) and ultra-thin layer chromatography (UTLC) plates as surfaces for desorption electrospray ionization (DESI) was compared with that of polymethyl methacrylate (PMMA) and polytetrafluoroethylene (PTFE), both popular surfaces in previous DESI studies. The limits of detection (LODs) and other analytical characteristics for six different test compounds were determined using all four surfaces. The LODs for the compounds were in the fmol-pmol (pg-ng) range. The LODs with the pSi surface were further improved for each of the compounds when heat was applied to the surface during sample application which gave LODs as low as or lower than those achieved with PMMA and PTFE. The UTLC plates were successfully used as a rapid means of chromatographic separation prior to DESI-MS analysis. Another advantage achieved using the newer pSi and UTLC surfaces was increased speed of analysis, associated with drying of solution-phase samples. This took place immediately at the UTLC surface and it could be achieved rapidly by gently heating the pSi surface. The presence of salts in the sample did not cause suppression of the analyte signal with any of the surfaces.

Acetylcholine↗

Minimum proton affinity for efficient ionization with atmospheric pressure desorption/ionization on silicon mass spectrometry.

We performed a systematic study using a set of compounds with different proton affinities (PAs) on the ionization in atmospheric pressure desorption/ionization on silicon mass spectrometry (AP-DIOS-MS). The compounds studied included various aromatic molecules of different sizes. The PAs of these compounds were calculated using ab initio and hybrid density functional theory calculations at the B3LYP/6-31G(d) level of theory. We observed that only compounds with relatively high PAs above a threshold value of 920-950 kJ/mol were efficiently ionized as protonated molecules under AP-DIOS conditions and produced very clean mass spectra.

Adsorption↗

Characterization of SU-8 for electrokinetic microfluidic applications.

The characterization of SU-8 microchannels for electrokinetic microfluidic applications is reported. The electroosmotic (EO) mobility in SU-8 microchannels was determined with respect to pH and ionic strength by the current monitoring method. Extensive electroosmotic flow (EOF), equal to that for glass microchannels, was observed at pH > or =4. The highest EO mobility was detected at pH > or =7 and was of the order of 5.8 x 10(-4) cm(2) V(-1) s(-1) in 10 mM phosphate buffer. At pH < or =3 the electroosmotic flow was shown to reverse towards the anode and to reach a magnitude of 1.8 x 10(-4) cm(2) V(-1) s(-1) in 10 mM phosphate buffer (pH 2). Also the zeta-potential on the SU-8 surface was determined, employing lithographically defined SU-8 microparticles for which a similar pH dependence was observed. SU-8 microchannels were shown to perform repeateably from day to day and no aging effects were observed in long-term use.

Journal Article↗

Rapid simultaneous determination of metabolic clearance of multiple compounds catalyzed in vitro by recombinant human UDP-glucuronosyltransferases.

The purpose of this study was to test the applicability of n-in-one (cocktail) incubations in the determination of intrinsic clearance (Cl(int)) as the slope of the linear portion of the Michaelis-Menten curve (velocity V vs. substrate concentration [S]) where substrate concentrations were low. A rapid, sensitive, and selective liquid chromatography tandem mass spectrometry (LC/MS/MS) method was developed for the analysis of samples produced by single-substrate and n-in-one (seven substrates: entacapone, 17beta-estriol, umbelliferone, 4-methylumbelliferone, tolcapone, hydroxyquinoline, and paracetamol) incubations conducted in 96-well plates with different recombinant UDP-glucuronosyltransferases (UGTs). The Cl(int) values obtained with n-in-one incubations were compared with those obtained in single-compound incubations and with V(max)/K(m) values determined by estimating the enzyme kinetic parameters V(max) and K(m) from the Michaelis-Menten curve. When substrate concentrations were well below their K(m) values, Cl(int) values determined as the slope of the linear part of the Michaelis-Menten fitting correlated well with the values determined as V(max)/K(m) ratios from the Michaelis-Menten curve. The correlation between Cl(int) values determined in single-substrate and n-in-one incubations was high as well. Together, the n-in-one incubations, the determination of Cl(int) values as the slope of the linear part of the Michaelis-Menten fitting, and LC/MS/MS as an analytical method proved to be effective approaches for increasing throughput in the first-phase screening of metabolic properties.

Catechols↗

Analysis of small molecules by ultra thin-layer chromatography-atmospheric pressure matrix-assisted laser desorption/ionization mass spectrometry.

The feasibility of ultra thin-layer chromatography atmospheric pressure matrix-assisted laser desorption ionization mass spectrometry (UTLC-AP-MALDI-MS) has been studied in the analysis of small molecules. Because of a thinner adsorbent layer, the monolithic UTLC plates provide 10-100 times better sensitivity in MALDI analysis than conventional high performance thin-layer chromatography (HPTLC) plates. The limits of detection down to a low picomole range are demonstrated by UTLC-AP-MALDI-MS. Other advantages of UTLC over HPTLC include faster separations and lower solvent consumption. The performances of AP-MALDI-MS and vacuum MALDI-MS have been compared in the analysis of small drug molecules directly from the UTLC plates. The desorption from the irregular surface of UTLC plates with an external AP-MALDI ion source combined with an ion trap instrument provides clearly less variation in measurements of m/z values when compared with a vacuum MALDI-time-of-flight (TOF) instrument. The performance of the UTLC-AP-MALDI-MS method has been applied successfully to the purity analysis of synthesis products produced by solid-phase parallel synthesis method.

Atmospheric Pressure↗

Kinetic characterization of the 1A subfamily of recombinant human UDP-glucuronosyltransferases.

The initial glucuronidation rates were determined for eight recombinant human UDP-glucuronosyltransferases (UGTs) of the 1A subfamily, and the bisubstrate kinetics and inhibition patterns were analyzed. At low substrate concentrations, the reactions followed general ternary complex kinetics, whereas at higher concentrations of both substrates, the reactions were mostly characterized by ternary complex kinetics with substrate inhibition. The glucuronidation of entacapone by UGT1A9 was inhibited by 1-naphthol in a competitive fashion, with respect to entacapone, and an uncompetitive fashion, with respect to UDP-glucuronic acid (UDPGA). Its inhibition by UDP, on the other hand, was noncompetitive with respect to entacapone and competitive with respect to UDPGA. These inhibition patterns are compatible with a compulsory ordered bi bi mechanism in which UDPGA is the first-binding substrate. Despite the identical primary structure of the C-terminal halves of the UGT1A isoforms, there were marked differences in the respective K(m) values for UDPGA, ranging from 52 microM for UGT1A6 to 1256 microM for UGT1A8. Relative specificity constants were calculated for the eight UGT1A isoforms with 1-hydroxypyrene, 4-nitrophenol, scopoletin, 4-methylumbelliferone, and entacapone as aglycone substrates. The results demonstrated that seven of the UGT1A isoforms are capable of conjugating phenolic substrates with similar highest k(cat) values, and UGT1A4 has a lower relative turnover rate. The highest specificity constants were obtained for 1-hydroxypyrene, even with UGT1A6, which has been regarded as a specific isoform for small planar phenols. A k(cat) value of 1.9 s(-1) was calculated for the glucuronidation of scopoletin by purified UGT1A9.

Catalysis↗

Biosynthesis of dobutamine monoglucuronides and glucuronidation of dobutamine by recombinant human UDP-glucuronosyltransferases.

Selected aspects of dobutamine glucuronidation were studied in detail. There are potentially four sites at which dobutamine can be conjugated to glucuronic acid. Three of the four dobutamine monoglucuronides that can be formed were enzymatically synthesized using pig liver microsomes, isolated, and characterized by tandem mass spectrometry, and (1)H and (13)C NMR spectroscopy. Analysis of dobutamine glucuronidation by liver microsomes from various sources revealed large variability in the ratios of the three regioisomers. Interestingly, catecholic dobutamine meta-O-glucuronide, by far the major product synthesized with human liver microsomes, was only a minor product for rat liver microsomes. Rabbit liver microsomes yielded diglucuronides, in addition to monoglucuronides. Activities of individual recombinant human UDP-glucuronosyltransferases (UGTs) were investigated, and the results suggested that dobutamine glucuronidation in the human liver is mainly carried out by UGTs 2B7 and 1A9. Among the extrahepatic UGTs, the formation of monoglucuronides, mainly catecholic meta-O-glucuronide, by UGTs 1A7 and 1A8 was similar to that by 1A9, whereas UGT1A10 also efficiently catalyzed the formation of catecholic dobutamine para-O-glucuronide.

Adrenergic beta-Agonists↗

Fabrication of enclosed SU-8 tips for electrospray ionization-mass spectrometry.

We describe a novel electrospray tip design for MS which is fabricated completely out of SU-8 photoepoxy. A three-layer SU-8 fabrication process provides fully enclosed channels and tips. The tip shape and alignment of all SU-8 layers is done lithographically and is therefore very accurate. Fabrication process enables easy integration of additional fluidic functions on the same chip. Separation channels can be made with exactly the same process. Fluidic inlets are made in SU-8 during the fabrication process and no drilling or other postprocessing is needed. Channels have been fabricated and tested in the size range of 10 microm x 10 microm-50 microm x 200 microm. Mass spectrometric performance of the tips has been demonstrated with both pressure-driven flow and EOF. SU-8 microtips have been shown to produce stable electrospray with EOF in a timescale of tens of minutes. With pressure driven flow stable spray is maintained for hours. Taylor cone was shown to be small in volume and well defined even with the largest channel cross section. The spray was also shown to be well directed with our tip design.

Epoxy Resins↗

Analysis of amphetamines and fentanyls by atmospheric pressure desorption/ionization on silicon mass spectrometry and matrix-assisted laser desorption/ionization mass spectrometry and its application to forensic analysis of drug seizures.

The suitability of atmospheric pressure desorption/ionization on silicon mass spectrometry (AP-DIOS-MS) and matrix-assisted laser desorption ionization mass spectrometry (AP-MALDI-MS) for the identification of amphetamines and fentanyls in forensic samples was studied. With both ionization techniques, the mass spectra recorded showed abundant protonated molecules, and the background did not disturb the analysis. The use of tandem mass spectrometry (MS/MS) allowed unambiguous identification of the amphetamines and fentanyls. AP-DIOS-MS/MS and AP-MALDI-MS/MS were also successfully applied to the identification of authentic compounds from drug seizures. Common diluents and tablet materials did not disturb the analysis and compounds were unequivocally identified. The limits of detection (LODs) for amphetamines and fentanyls with AP-DIOS-MS/MS were 1-3 pmol, indicating excellent sensitivity of the method. The LODs with AP-MALDI-MS/MS were about 5-10 times higher.

Amphetamines↗