Publications and source records attributed to Rizwan Ahmad.

9 recordsLinked to original sources

Enhanced resolution for EPR imaging by two-step deblurring.

The broad spectrum of spin probes used for electron paramagnetic resonance imaging (EPRI) result in poor spatial resolution of the reconstructed images. Conventional deconvolution procedures can enhance the resolution to some extent but obtaining high resolution EPR images is still a challenge. In this work, we have implemented and analyzed the performance of a postacquisition deblurring technique to enhance the spatial resolution of the EPR images. The technique consists of two steps; noniterative deconvolution followed by iterative deconvolution of the acquired projections which are then projected back using filtered backprojection (FBP) to reconstruct a high resolution image. Further, we have proposed an analogous technique for iterative reconstruction algorithms such as multiplicative simultaneous iterative reconstruction technique (MSIRT) which can be a method of choice for many applications. The performance of the suggested deblurring approach is evaluated using computer simulations and EPRI experiments. Results suggest that the proposed procedure is superior to the standard FBP and standard iterative reconstruction algorithms in terms of mean-square-error (MSE), spatial resolution, and visual judgment. Although the procedure is described for 2D imaging, it can be readily extended to 3D imaging.

Algorithms↗

Quasi Monte Carlo-based isotropic distribution of gradient directions for improved reconstruction quality of 3D EPR imaging.

In continuous wave (CW) electron paramagnetic resonance imaging (EPRI), high quality of reconstructed image along with fast and reliable data acquisition is highly desirable for many biological applications. An accurate representation of uniform distribution of projection data is necessary to ensure high reconstruction quality. The current techniques for data acquisition suffer from nonuniformities or local anisotropies in the distribution of projection data and present a poor approximation of a true uniform and isotropic distribution. In this work, we have implemented a technique based on Quasi-Monte Carlo method to acquire projections with more uniform and isotropic distribution of data over a 3D acquisition space. The proposed technique exhibits improvements in the reconstruction quality in terms of both mean-square-error and visual judgment. The effectiveness of the suggested technique is demonstrated using computer simulations and 3D EPRI experiments. The technique is robust and exhibits consistent performance for different object configurations and orientations.

Algorithms↗

Application of magnetic field over-modulation for improved EPR linewidth measurements using probes with Lorentzian lineshape.

Magnetic field modulation in CW electron paramagnetic resonance (EPR) is used for signal detection. However, it can also distort signal lineshape. In experiments where the linewidth information is of particular importance, small modulation amplitude is usually used to limit the lineshape distortion. The use of small modulation amplitude, however, results in low signal-to-noise ratio and therefore affects the precision of linewidth measurements. Recently, a new spectral simulation model has been developed enabling accurate fitting of modulation-broadened EPR spectra in liquids. Since the use of large modulation amplitude (over-modulation) can significantly enhance the EPR signal, the precision of linewidth measurements is therefore greatly improved. We investigated the over-modulation technique in EPR oximetry experiments using the oxygen-sensing probe lithium octa-n-butoxy-substitued naphthalocyanine (LiNc-BuO). Modulation amplitudes 2-18 times the intrinsic linewidth of the probe were applied to increase the spectral signal-to-noise ratio. The intrinsic linewidth of the probe at different oxygen concentrations was accurately extracted through curve fitting from the enhanced spectra. Thus, we demonstrated that the over-modulation model is also applicable to particulate oxygen-sensing probes such as LiNc-BuO and that the lineshape broadening induced by oxygen is separable from that induced by over-modulation. Therefore, the over-modulation technique can be used to enhance sensitivity and improve linewidth measurements for EPR oximetry with particulate oxygen-sensing probes with Lorentzian lineshape. It should be particularly useful for in vivo oxygen measurements, in which direct linewidth measurements may not be feasible due to inadequate signal-to-noise ratio.

Computer Simulation↗

Optimization of data acquisition for EPR imaging.

In electron paramagnetic resonance imaging (EPRI), long data acquisition time is one of the major problems limiting successful and useful biological EPRI experiments. Depending on the configuration (spatial distribution of paramagnetic species), information embedded in some objects can be characterized using a smaller number of projections, while others may require significantly larger number of projections to generate similar results. In order to optimize the acquisition process, it is therefore important to acquire a different number of projections for different objects. In this paper, a prediction scheme is demonstrated that can determine the number of projections required to achieve a preset reconstruction quality for a given object. After acquiring first few projections, corresponding partially filled k-space is analyzed. The complexity of data (to interpolate) in k-space is quantified and used to predict the number of required projections. All the projections are acquired using a mean-square difference-based adaptive acquisition technique that is also demonstrated in this work. The purpose of this non-uniform acquisition is to reduce redundancy in the acquired data which in turn decreases the number of projections required for the given object. It is also demonstrated that the performance of non-uniform acquisition is content dependant, and for certain configurations it may not be as effective as uniform acquisition in preserving signal from low intensity regions. The prediction scheme along with the non-uniform acquisition is tested using computer simulations, imaging of experimental phantoms, and in vivo imaging. Results indicate that the proposed method may save up to 50% of acquisition time. The techniques in this manuscript are described for 2D spatial imaging but can be extended to 3D imaging.

Algorithms↗

Automated on-the-fly detection and correction procedure for EPR imaging data acquisition.

Fast and reliable data acquisition is a major requirement for successful and useful biological electron paramagnetic resonance imaging (EPRI) experiments. Even a technologically advanced and professionally supervised EPRI system can exhibit instabilities initiated by perturbations such as animal motion, microphonics, and temperature changes. As a result, part of an acquired data set may become corrupted with excessive noise and distortions, which in turn may degrade the quality of the reconstructed image. In this work an automated scheme to monitor the system performance and stability over the course of an experiment is demonstrated. This method ensures that the quality of the acquired data is maintained during the experiment. For this purpose, four parameters including noise content and integration of each acquired projection are quantified and measured against those of the zero-gradient (ZG) projection, which is set as a quality benchmark. Projections with parameter values that differ substantially from the expected values are identified as damaged and consequently are reacquired. Therefore, the proposed technique not only effectively monitors the quality of acquisition, it also saves a substantial amount of acquisition time because it eliminates the necessity of repeating the entire experiment in cases in which only a small fraction of the data are corrupted.

Algorithms↗

Concomitant presence of subtypes of left coronary artery disease.

OBJECTIVE: To study the risk profile associated with surgical revascularization for mixed left main and left main equivalent diseases. METHODS AND RESULTS: Retrospective analysis of medical records of patients who underwent CABG from January 1997 and December 2002 were studied. 210 patients were included of which 30.5% (64) had left main, 49.5% (104) had left main equivalent and 20% (42) had mixed type of stenotic disease. The mixed type left coronary disease was associated with very high post-operative mortality. The factors associated with mortality were degree of left main artery stenosis, cardiopulmonary bypass pump time, no. of packed cell units transfused during surgery, post-operative low cardiac output, re-exploration of chest and no. of days spent as intubated. Low cardiac output, chest re-exploration and no. of days intubated were independently associated with mortality. CONCLUSIONS: "Mixed left main and left main equivalent disease" makes a large proportion of left sided CAD. It is a unique subtype associated with very high risk, and it should be treated with extra caution. Characterization of its risk profile should be done with larger studies to improve the outcome.

Aged↗

Flow cytometric analysis of aneuploidy and S-phase fraction in chronic myeloid leukemia patients: role in early detection of accelerated phase.

We studied S-phase fraction (SPF) and aneuploidy in peripheral blood leucocytes of patients with chronic myeloid leukemia (CML) in chronic phase (CML-CP, n=41), accelerated phase (CML-AP, n=6), and control subjects (n=12) with an aim to find out their role in early detection of accelerated phase. The SPF and aneuploidy were studied through flow-cytometry using LT-Mod. Fit software. Mean SPF value in CML-AP (9.28+/-3.46%) and in CML-CP (4.76+/-2.30%) were significantly higher than in normal controls (0.28+/-0.21%), (P<0.005, P<0.001). CML-CP patients having higher SPF (>7%) converted to accelerated phase within 18 months of follow-up while those with lower SPF (<7%) did not. Aneuploidy was present in 34.14% of CML-CP and all patients of CML-AP whereas no control subjects showed aneuploidy. Among CML-CP patients having SPF >7%, 86% developed aneuploidy during follow-up as compared to 18.50% of CML-CP with less than 7% SPF. We conclude that peripheral blood SPF and aneuploidy could be important parameters for prediction of evolution to accelerated phase in CML patients.

Adult↗

Peripheral blood leucocytes ornithine decarboxylase activity in chronic myeloid leukemia patients: prognostic and therapeutic implications.

Leukocytes ornithine decarboxylase (ODC) activity was measured in normal individuals and in patients with chronic myeloid leukemia (CML) in chronic phase (CML-CP) as well as in accelerated phase (CML-AP), with an aim to examine the role of ODC activity in prognostic evaluation of CML patients. Our results showed that ODC activity was significantly higher in CML-CP (41.02+/-25.57nmol/h per 10(7) cells, P<0.005) and CML-AP (67.71+/-44.42nmol/h per 10(7) cells, P<0.001) patients than in normal subjects (3.12+/-1.34nmol/h per 10(7) cells). Furthermore, patients with CML-AP showed higher ODC activity than CML-CP patients (P<0.005). Patients with CML-CP who converted to accelerated phase within 24 months had higher ODC activity (84.58+/-12.81nmol/h per 10(7) cells) than patients who did not convert to accelerated phase (31.13+/-18.24nmol/h per 10(7) cells). The high value of ODC activity was also associated with less clinico-hematological response. We suggest that ODC activity reflects the neoplastic proliferative activity in CML patients and may serve as an additional prognostic marker.

Adolescent↗