PubMed Health⌕ Search

Biomedical subjects

Robbert J Nijenhuis

Publications and source records attributed to Robbert J Nijenhuis.

8 recordsLinked to original sources

Magnetic resonance angiography and neuromonitoring to assess spinal cord blood supply in thoracic and thoracoabdominal aortic aneurysm surgery.

OBJECTIVE: Preoperative knowledge of the blood-supplying trajectory to the spinal cord is of interest, because spinal cord ischemia may occur during thoracic aortic aneurysm (TAA) and thoracoabdominal aortic aneurysm (TAAA) repair and possibly leads to paraplegia. The Adamkiewicz artery (AKA) is considered to be the most important blood supplier of the thoracolumbar spinal cord and has therefore been the focus in preoperative diagnostic imaging. However, in TAA(A) patients, the blood supply to the spinal cord may strongly depend on (intersegmental) collateral circulation, because many segmental arteries are occluded as a result of atherosclerosis. Therefore, the importance of preserving the segmental artery supplying the AKA (SA-AKA) is debated. Here it was investigated whether (1) the AKA and its segmental supplier can be imaged by using magnetic resonance (MR) angiography and (2) aortic cross-clamping of the SA-AKA influences intraoperative spinal cord function, monitored by motor evoked potentials (MEPs). METHODS: Preoperative MR angiography was performed to localize the SA-AKA and the AKA in 60 patients (19 TAA, 7 TAAA I, 18 TAAA II, 9 TAAA III, and 7 TAAA IV). Spinal cord function was monitored during surgery by using MEPs. When MEPs indicated critical ischemia, the SA-AKA was selectively reattached. To test whether aortic cross-clamping of the SA-AKA was associated with MEP decline, the Fisher statistical exactness test was applied. RESULTS: The AKA and SA-AKA could be localized in all 60 (100%) patients between vertebral levels T8 and L2 (72% left sided). In 44 (73%) patients, the SA-AKA was cross-clamped, which led in 32% (14/44) of cases to MEP decline. Reattachment of the preoperatively localized SA-AKA re-established MEPs and, thus, spinal cord function in 12 of 14 cases. When the SA-AKA was outside the area cross-clamped, the MEPs always remained stable. A significant association (P < .01) was found between the location of the SA-AKA relative to the aortic cross-clamps and the MEPs. CONCLUSIONS: The AKA can be localized before surgery in 100% of TAA(A) patients by using MR angiography. Location of the SA-AKA outside the cross-clamped aortic area is attended with stable MEPs. Interestingly, it was found that in most patients in whom the SA-AKA was cross-clamped, MEPs were not affected, thus indicating sufficient collateral blood supply to maintain spinal cord integrity. Nevertheless, preoperative knowledge of SA-AKA location is of importance, because in 32% of patients, spinal cord function was dependent on this supplier. Revascularization of the SA-AKA can thereby reverse spinal cord dysfunction.

Aged↗

The value of motor evoked potentials in reducing paraplegia during thoracoabdominal aneurysm repair.

OBJECTIVE: Paraplegia after thoracoabdominal aortic aneurysm (TAAA) repair mainly occurs in patients with Crawford extent I and II. We assessed the impact of monitoring spinal cord integrity and the subsequent adjusted surgical maneuvers on neurologic outcome in repairs of type I and II TAAAs. METHODS: Surgical repair of TAAAs was performed in 112 consecutive patients with extent type I (n = 42) and type II (n = 70) aneurysms. The surgical protocol included cerebrospinal fluid drainage, moderate hypothermia, and left heart bypass with selective organ perfusion. Spinal cord function was assessed by means of monitoring motor evoked potentials (MEPs). Significant decreased MEPs always generated adjustments, including raising distal aortic and mean arterial pressure, reattachment of visible intercostal arteries, or endarterectomy of the excluded aortic segment with revascularization of back bleeding intercostal arteries. RESULTS: Motor evoked potential monitoring could be achieved in all patients. By maintaining a mean distal aortic pressure of 60 mm Hg, MEPs were adequate in 82% of patients. Increasing distal aortic pressure restored MEPs in all patients. In 19 patients (17%), MEPs decreased significantly during aortic cross-clamping because of critical spinal cord ischemia. MEPs returned in all patients after spinal cord blood flow was re-established except in three patients with type II TAAA in whom MEPs could not be restored, and absent MEPs at the end of the procedure corresponded with neurologic deficit. Delayed paraplegia developed in two patients owing to hemodynamic instability with insufficient mean arterial blood pressure to maintain adequate spinal cord perfusion. CONCLUSION: Monitoring MEPs is a highly reliable technique to assess spinal cord ischemia during TAAA repair. A surgical protocol including cerebrospinal fluid drainage, left heart bypass, and monitoring of MEPs can reduce the paraplegia rate significantly. Adjusted hemodynamic and surgical strategies induced by changes in MEPs could restore spinal cord ischemia in most patients, preventing early and late paraplegia in all type I patients. In type II patients, early paraplegia occurred in 4.2% and delayed neurologic deficit in 2.9%. Despite all available measures, complete prevention of paraplegia in type II aneurysms seems to be unrealistic.

Adult↗

Contrast-enhanced peripheral MR angiography using SENSE in multiple stations: feasibility study.

PURPOSE: To investigate if the use of parallel imaging is feasible and beneficial for peripheral contrast-enhanced magnetic resonance angiography (CE-MRA). MATERIALS AND METHODS: A total of 19 consecutive patients underwent peripheral CE-MRA using SENSE with two-fold reduction in the upper and lower leg stations. Conventional nonaccelerated imaging using constant level appearance (CLEAR) was used in the aortoiliac station. The findings were compared with those in a similar patient group that underwent peripheral CE-MR angiography using our standard imaging protocol without SENSE. Intraarterial digital subtraction angiography (IA-DSA) was used as the standard of reference. Lower extremity vessels were divided into anatomic segments (aortoiliac, upper legs, lower legs) for review. In each anatomic segment signal- and contrast-to-noise ratios (SNR, CNR), venous contamination, subjective image quality, as well as sensitivity and specificity, were determined for both patient groups. RESULTS: SNR and CNR improved significantly for the aortoiliac and upper leg segments (all P-values < or = 0.001). Small reductions were seen in the frequency of disturbing venous enhancement (P = not significant). There were no significant differences with regards to subjective image quality or diagnostic accuracy (all P > 0.3). Overall sensitivity and specificity in the SENSE group were 81% and 95%, respectively. For the non-SENSE group, these values were 79% and 96%, respectively. CONCLUSION: Preliminary results show that three-station peripheral CE-MRA using a full length peripheral arterial coil in combination with SENSE in the upper and lower leg stations is feasible and useful for further optimization of peripheral MRA. Using SENSE allows for routine, high-quality depiction of the entire peripheral vascular tree including the pedal arch. Higher SENSE factors are needed for further optimization.

Aged↗

Comparison of 0.5-M Gd-DTPA with 1.0-M gadobutrol for magnetic resonance angiography of the supplying arteries of the spinal cord in thoracoabdominal aortic aneurysm patients.

PURPOSE: To prospectively compare 0.5-M gadopentetate dimeglumine (Gd-DTPA) with 1.0-M gadobutrol for contrast-enhanced magnetic resonance angiography (CE-MRA) of the blood supplying arteries of the spinal cord in patients referred for open surgical repair of a thoracoabdominal aortic aneurysm (TAAA). MATERIALS AND METHODS: A total of 11 patients with a TAAA underwent two three-dimensional CE-MRA exams of the aorta, segmental arteries (SAs), artery of Adamkiewicz (AKA), and anterior spinal artery (ASA). Imaging was performed on two separate occasions using Gd-DTPA and gadobutrol as contrast agents at 0.3 mmol/kg. Images were evaluated by measuring signal-to-noise (SNR) and contrast-to-noise (CNR) ratios and were judged for different image quality criteria by two blinded observers. RESULTS: In all patients both CE-MRA exams were of sufficient image quality to detect the AKA and ASA. No significant differences in SNR and CNR were observed between the two contrast agents. According to the observers, no significant differences in subjective image quality were found. CONCLUSIONS: Using both contrast agents it was possible to visualize the ultrasmall spinal cord arteries in all cases. The use of the 1.0-M contrast agent did not improve image quality of CE-MRA images of the blood supplying arteries of the spinal cord compared to the 0.5-M contrast agent.

Aged↗

Accuracy of semiautomated analysis of 3D contrast-enhanced magnetic resonance angiography for detection and quantification of aortoiliac stenoses.

OBJECTIVES: We sought to compare reproducibility and accuracy of semiautomated stenosis detection and quantification in 3D contrast-enhanced magnetic resonance angiography (CE-MRA) images with conventional evaluation of 3D CE-MRA in patients with peripheral arterial disease (PAD) by using intra-arterial digital subtraction angiography (IA-DSA) as standard of reference. METHODS: Twenty-five patients with PAD underwent CE-MRA and IA-DSA. Three blinded observers independently evaluated CE-MRA datasets for stenoses in the aortoiliac region using semiautomated computer analysis. Semiautomated measurements were compared with conventional measurements of stenosis on CE-MRA datasets, as measured by 3 other independent observers blinded to all other measurements. Interobserver agreement was quantified using kappa (kappa) and intraclass correlation coefficients (ICCs). Sensitivity and specificity were determined for both semiautomated and conventional measurements. RESULTS: Semiautomated measurements were successful in 124 of the 125 arterial segments. The sensitivity of semiautomated measurements was 89% for all observers; specificity varied between 87% and 89%. For conventional measurements of CE-MRA, sensitivity varied between 79% and 86%; specificity was between 86% and 96%. There was good interobserver agreement between all readers for semiautomated measurements (combined kappa for all 3 observers together = 0.78; ICC = 0.82), as well as for conventional measurements (combined kappa = 0.70; and ICC = 0.83). Differences between ICCs, combined kappa values, and accuracy of both measurements were not significant (all P > 0.05). CONCLUSION: Semiautomated analysis of aortoiliac 3D CE-MRA has the same high accuracy for detection and quantification of stenoses as conventional readings of CE-MRA.

Aged↗

Spinal cord feeding arteries at MR angiography for thoracoscopic spinal surgery: feasibility study and implications for surgical approach.

PURPOSE: To prospectively investigate the feasibility of contrast material-enhanced magnetic resonance (MR) angiography for visualization of the spinal vasculature in patients referred for video-assisted thoracoscopic surgical treatment of a thoracic herniated disk and to prospectively assess the influence of preoperative imaging of the spinal vasculature on the choice of surgical approach. MATERIALS AND METHODS: Eight patients (three men and five women; mean age, 58 years; range, 42-83 years) with a thoracic herniated disk underwent contrast-enhanced MR angiography of the thoracoabdominal aorta and posterior branches. Imaging was performed with three-dimensional first-pass contrast-enhanced MR angiographic technique and a triple dose of gadolinium-based contrast agent. Images were analyzed by two observers in consensus to localize the Adamkiewicz artery (AKA) and its connections to the aorta and the anterior spinal artery (ASA). This information was used to determine any change in surgical approach. RESULTS: In all eight patients, the AKA, the ASA, and the connections with the aorta were identified. The AKA originated between T9 and L2 in all patients and derived from the left side of the aorta in 75% (six of eight) of the patients. In three patients in whom the AKA was observed on the left side, the surgical approach was changed to the right side to preserve spinal cord integrity. CONCLUSION: Preoperative imaging of the AKA is feasible with contrast-enhanced MR angiography. Contrast-enhanced MR angiography can be used to image the main feeding arteries of the spinal cord in patients undergoing thoracoscopic spinal surgery, and results can be used to change the side of surgical approach.

Adult↗

Use of a three-station phased array coil to improve peripheral contrast-enhanced magnetic resonance angiography.

PURPOSE: To explore the imaging capabilities of a new commercially available, three-station, 129-cm long, 12-element phased array coil for contrast-enhanced magnetic resonance angiography (CE-MRA) in patients with symptomatic peripheral arterial occlusive disease. MATERIALS AND METHODS: Nineteen patients, referred for peripheral CE-MRA, were evaluated using the new three-station coil. For each station four coil elements (two anterior and two posterior to the patient) were used. The expected improvements in signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were used to improve spatial resolution and increase anatomic coverage for the distal two stations compared to our previous protocol. Images obtained in the 19 patients imaged with the new coil were compared to those of the last 19 patients scanned without the use of the new coil. Differences in image quality before vs. after the availability of the new coil were compared in terms of SNR and CNR, subjective interpretability score (SIS), degree of venous enhancement, and anatomic coverage. Images were interpreted by two experienced observers, blinded for imaging technique and each other's results. RESULTS: Use of the coil enabled acquisition of high resolution peripheral vasculature images in all cases and allowed for substantially smaller voxel sizes (thighs: 5.3 vs. 8.4 mm(3) [-37%]; legs: 1.8 vs. 8.0 mm3 [-78%]) and much shorter acquisition durations in the aortoiliac and thigh stations (aortoiliac: 16 vs. 27 seconds [-41%]; thighs: 11 vs. 23 seconds [-52%]). Acquisition duration in the leg station was prolonged (68 vs. 29 seconds [+134%]). SNR and CNR were significantly higher only in the aortoiliac station using the three-station coil (both: P < 0.001). There were no significant differences in SIS for the aortoiliac and thigh stations (aortoiliac station: observer 1: P = 0.16, observer 2: P = 0.19; thigh station: both observers: P = 0.27). Images acquired with the new coil had significantly higher SIS for the leg station (both observers: P = 0.004). There were no significant differences in venous enhancement between the two protocols for any of the stations (all P > 0.11). In 12/12 (100%) requested cases the entire pedal arch was depicted using the new coil, whereas this was not possible with the old protocol. CONCLUSION: The new three-station dedicated peripheral vascular coil allows for much higher resolution imaging in the thigh and leg stations with greater anatomic coverage and substantially improves peripheral MRA quality of the lower leg vasculature.

Adult↗

Motion of the distal renal artery during three-dimensional contrast-enhanced breath-hold MRA.

PURPOSE: To study the potential detrimental effects of renal motion on breath-hold three-dimensional contrast-enhanced (CE) magnetic resonance angiography (MRA). MATERIALS AND METHODS: A computer model simulating linear motion was applied to MRA pulse sequences. Subsequently, to study whether renal motion was present, 24 patients being evaluated for possible renovascular hypertension underwent a breath-hold nonenhanced single slice two-dimensional dynamic turbo field-echo magnetic resonance imaging (MRI) scan with a typical duration of 32 seconds. This sequence was followed by breath-hold three-dimensional CE renal MRA. CE-MRA images were evaluated by two independent observers. RESULTS: The computer model revealed linear renal motion to cause artifacts. The severity of these artifacts correlated with velocity. Significant (P < 0.001) near linear cranial motion of the kidneys and diaphragm during a sustained breath-hold was found for the right kidney, left kidney, right diaphragm, and left diaphragm (0.26 +/- 0.21 mm/second, 0.25 +/- 0.23 mm/second, 0.43 +/- 0.43 mm/second, and 0.29 +/- 0.33 mm/second [mean +/- SD], respectively). CE-MRA images showed artifacts of the distal renal artery that corroborated the computer model findings. CONCLUSION: The observed cranial motion of the kidneys during a breath-hold adversely affects distal renal artery image quality on three-dimensional CE-MRA and jeopardizes reliable clinical evaluation. Shortening scan time may be beneficial for decreasing image degradation caused by this phenomenon.

Adult↗