PubMed Health⌕ Search

Biomedical subjects

Robbert M Maes

Publications and source records attributed to Robbert M Maes.

4 recordsLinked to original sources

Combined use of the intravascular blood-pool agent, gadomer, and carbon dioxide: a novel type of double-contrast magnetic resonance angiography (MRA).

PURPOSE: To evaluate the combined use of carbon dioxide (CO(2)) and a gadolinium-based blood-pool agent for magnetic resonance angiography (MRA). MATERIALS AND METHODS: After an initial intravenous injection of the blood-pool agent Gadomer (Schering AG, Germany), repeated transcatheter CO(2) injections were performed in the aorta and the renal arteries of two fully-anesthetized pigs. Real-time images were acquired using a true fast imaging with steady-state precession (FISP) sequence. RESULTS: During the CO(2) injections, the Gadomer-enhanced blood was totally replaced, resulting in an immediate, temporary, total signal loss in the vessel lumen. Susceptibility artifacts during the injections or catheter manipulations rarely occurred. CONCLUSION: Due to T1-shortening, the circulating blood-pool agent prevents flow artifacts during catheter manipulations because the steady-state is reached much earlier. Therefore, this double-contrast MRA method improves catheter conspicuity and might be helpful for guiding and controlling intravascular procedures during interventional MRI.

Animals↗

MR imaging-guided vascular procedures using CO2 as a contrast agent.

OBJECTIVE: The purpose of this study was to test the use of CO(2) as a black blood contrast agent for MR imaging-guided vascular procedures in an animal model. MATERIALS AND METHODS: Repeated intraarterial CO(2) injections were performed through a catheter located in the aorta and the renal arteries of three fully anesthetized pigs. Real-time images were acquired using a steady-state free precession sequence. RESULTS: During the CO(2) injections, the bright blood in the aorta and the main renal artery was totally replaced, and this procedure resulted in an immediate, statistically significant signal loss in the vessel lumen. In more peripheral vessels, CO(2) improved the vessel conspicuity substantially. Confirmation of vessel patency distal to the catheter tip position was possible. CONCLUSION: The use of carbon dioxide in combination with a bright blood MR imaging sequence improves vessel conspicuity and provides immediate information about blood flow distal to the catheter. This technique may be used to facilitate MR imaging-guided intravascular procedures.

Animals↗

Use of intra-articular carbon dioxide and air for MR arthrography: a feasibility study.

During animal experiments, carbon dioxide (CO(2)) and air were used as a novel contrast agent for direct magnetic resonance arthrography (MRAr). MRAr was performed after injection of CO(2) and air in the knee joints of two pigs. MR images of phantoms containing air, CO(2) and nitrogen were compared. After intra-articular injection, both present as a signal void on various sequences and permit sharp delineation of cartilage and other adjacent structures. Despite the potential for artefact generation, only a slight susceptibility artefact was seen after injection of CO(2) and air. In phantom experiments, air, CO(2) and nitrogen demonstrated identical slight regular susceptibility artefacts at the phantom margins. CO(2) MRAr can yield high contrast between cartilage, ligaments and synovium relative to the joint compartment. Therefore, this technique might be useful as an investigational method for the evaluation of cartilage surface lesions and possibly as an alternative contrast agent for clinical use.

Air↗

A new type of susceptibility-artefact-based magnetic resonance angiography: intra-arterial injection of superparamagnetic iron oxide particles (SPIO) A Resovist in combination with TrueFisp imaging: a feasibility study.

The goal of this study was to evaluate the use of super paramagnetic particles of iron oxide (SPIO) as a dark blood contrast agent, in combination with a bright blood steady-state free precession sequence for magnetic resonance angiography (MRA), in an animal model. The original concentration of the SPIO of 500 mmol Fe/l and dilutions to 250, 125, 60, 30, 10 and 5 mmol Fe/l were intra-arterially injected into the aorta of a pig. Then the dilution of 10 mmol Fe/l was chosen for repeated intra-arterial injections into two pigs. During these intra-arterial SPIO injections MR images were acquired with a 1.5 T scanner. Signal intensity measurements were performed in the aorta. The signal-to-noise ratio during SPIO bolus passage was significantly less than during baseline conditions (Fisher's F-ratio 159.8, p < 0.005) or the recovery signal-to-noise ratio (Fisher's F-ratio 144.6, p < 0.005). Also, confirmation of flow distal to the catheter-tip position was possible. The use of SPIO as a dark blood agent in combination with a bright blood MR imaging sequence is feasible. Temporary loss of intraluminal signal occurs due to local decrease of the signal because of induction of local inhomogeneities after mixture the present blood and SPIO solution. It provides immediate information about blood flow distal to the catheter and is a potentially useful to guide intravascular MR-interventional procedures.

Animals↗