PubMed Health⌕ Search

Biomedical subjects

Robert A Gasser

Publications and source records attributed to Robert A Gasser.

9 recordsLinked to original sources

Fever in patients with mixed-species malaria.

BACKGROUND: Clinical symptoms of mixed-species malaria infections have been variously reported as both less severe and more severe than those of single-species infections. METHODS: Oral temperatures were taken from and blood slides were prepared for 2308 adults who presented at outpatient malaria clinics in Tak Province (Thailand) during May-August 1998, May-July 1999, and May-June 2001 with malaria infections diagnosed by 2 expert research microscopists, each of whom was blinded to the other's reports. RESULTS: In each year, temperatures of patients with mixed Plasmodium vivax-Plasmodium falciparum infections were higher than temperatures of patients with P. vivax or P. falciparum infections. In every mixed-species case, P. falciparum parasitemia was higher than P. vivax parasitemia, but patient temperature was not correlated with the parasitemia of either species or with the total parasitemia. CONCLUSIONS: Among adults who self-report to malaria clinics in western Thailand, patients with mixed P. vivax-P. falciparum infections have higher fevers than patients with single-species infections, a distinction that cannot be attributed to differences in parasitemia. This observation warrants more detailed investigations, spanning wider ranges of ages and transmission environments.

Adult↗

White blood cell counts and malaria.

White blood cells (WBCs) were counted in 4697 individuals who presented to outpatient malaria clinics in Maesod, Tak Province, Thailand, and Iquitos, Peru, between 28 May and 28 August 1998 and between 17 May and 9 July 1999. At each site and in each year, WBC counts in the Plasmodium falciparum-infected patients were lower than those in the Plasmodium vivax-infected patients, which, in turn, were lower than those in the uninfected patients. In Thailand, one-sixth of the P. falciparum-infected patients had WBC counts of <4000 cells/microL. Leukopenia may confound population studies that estimate parasite densities on the basis of an assumed WBC count of 8000 cells/microL. For instance, in the present study, use of this conventional approach would have overestimated average asexual parasite densities in the P. falciparum-infected patients in Thailand by nearly one-third.

Adolescent↗

Sources of variability in determining malaria parasite density by microscopy.

Enumeration of parasites by microscopic examination of blood smears is the only method available for quantifying parasitemia in infected blood. However, the sources and scale of error inherent in this technique have not been systematically investigated. Here we use data collected in outpatient clinics in Peru and Thailand to elucidate important sources of variation in parasite density measurements. We show that discrepancies between readings from two independent microscopists and multiple readings from a single microscopist are inversely related to the density of the infection. We present an example of how differences in reader technique, specifically the number of white blood cells counted, can contribute to the differences between readings. We discuss the implications of this analysis for field studies and clinical trials.

Animals↗

Hematologic and clinical indices of malaria in a semi-immune population of western Thailand.

This study examines hematologic profiles of persons with acute Plasmodium falciparum or P. vivax infection in Maesod on Thailand's western border with Myanmar compared with febrile, non-parasitemic persons also reporting to malaria clinics. Nine hundred seventy-nine subjects were malaria-negative, 414 were infected with P. falciparum, and 646 were infected with P. vivax. Persons with patent parasitemia tended to have significantly lower white blood cell, red blood cell, platelet, and hemoglobin levels than those who were malaria-negative. For the first time, a parallel trend in thrombocytopenia with parasitemia was found to be associated with both P. falciparum, and P. vivax infection. Using logistic regression, persons with platelet counts < 150,000/microL were 12-15 times more likely to have malaria than persons with platelet counts > or = 150,000/microL. This study supplements previous literature on the hematologic effects of malaria and helps define those alterations for a semi-immune population. Thrombocytopenia is identified as a key indicator of malaria in these febrile patients.

Adult↗

Rapid diagnostic testing for malaria.

Malaria rapid diagnostic devices (MRDD) have been developed with the hope that they would offer accurate, reliable, rapid, cheap and easily available alternatives to traditional methods of malaria diagnosis. The results from early malaria rapid diagnostic studies were quite promising, especially for detecting Plasmodium falciparum at densities of more than 100-500 parasites/microl. Despite the introduction of these devices over a decade ago, only a few target antigens have been introduced. Of greater concern, these devices have shown limitations in sensitivity, ability to differentiate species and robustness under field conditions in the tropics. Recent trials have revealed wide variability in sensitivity both within and between products. We review the recent trials assessing MRDD use for the diagnosis of P. falciparum and non-P. falciparum infections in endemic and non-endemic countries and describe the various aspects of these devices which need further improvement. High quality, accurate, rapid and affordable diagnostic tools are urgently needed now that new antimalarial regimens, characterized by higher cost and increased toxicity, have been introduced more widely in response to emerging multi-drug resistance.

Animals↗

Devices for rapid diagnosis of Malaria: evaluation of prototype assays that detect Plasmodium falciparum histidine-rich protein 2 and a Plasmodium vivax-specific antigen.

The ParaSight F test was developed as a pioneer industry effort in the large-scale, process-controlled production of a device for the rapid diagnosis of malaria. This device performed well in field settings but was limited to the detection of a single malaria species, Plasmodium falciparum. The ParaSight F+V assay advanced upon the ParaSight F test format by incorporating a monoclonal antibody directed against a proprietary Plasmodium vivax-specific antigen, in addition to the antibody directed against P. falciparum histidine-rich protein 2, which was used in the ParaSight F assay. The modified assay was developed to add the capability to detect P. falciparum and P. vivax in a single-test-strip format. The present study evaluated three distinct ParaSight F+V prototypes with samples from symptomatic patients in regions of Thailand and Peru where malaria is endemic. Over a 2-year enrollment period (1998 and 1999), a total of 4,894 patients consented to participation in the study. Compared with the results for duplicate microscopic examinations of Giemsa-stained blood smears as the reference diagnostic standard, each successive prototype showed substantial improvement in performance. The final ParaSight F+V prototype, evaluated in 1999, had an overall sensitivity for detection of asexual P. falciparum parasites of 98%. The sensitivity of the device was 100% for P. falciparum densities of >500 parasites/ micro l, with a sensitivity of 83% for parasite densities of </=500/ micro l. The specificity for the exclusion of P. falciparum was 93%. For P. vivax, the overall sensitivity was 87% for the final 1999 prototype. The sensitivities calculated for different levels of P. vivax parasitemia were 99% for parasite densities of >5,000/ micro l, 92% for parasite densities of 1,001 to 5,000/ micro l, 94% for parasite densities of 501 to 1,000/ micro l, and 55% for parasite densities of 1 to 500/ micro l. The specificity for the exclusion of P. vivax was 87%. The areas under the receiver operating characteristic curves for the diagnostic performance of the assay for the detection of P. falciparum and P. vivax were 0.8907 and 0.8522, respectively. These findings indicate that assays for rapid diagnosis have the potential to enhance diagnostic capabilities in those instances in which skilled microscopy is not readily available.

Animals↗

Rapid diagnostic devices for malaria: field evaluation of a new prototype immunochromatographic assay for the detection of Plasmodium falciparum and non-falciparum Plasmodium.

The NOW ICT Malaria P.f./P.v. for Whole Blood (Binax, Inc., Portland, ME) is a new malaria rapid diagnostic device that represents a technical advance over previous assays, such as ICT Malaria P.f./P.v. and ICT Malaria P.f.. We evaluated this device in March 2001 in symptomatic patients at malaria clinics in Maesod, Thailand. Microscopic examination of Giemsa-stained blood smears was the reference standard. In 246 patients, microscopy showed 32 (13.0%) infected with Plasmodium falciparum, 63 (25.6%) with P. vivax, 6 (2.4%) with mixed infections of P. falciparum and P. vivax, 5 (2.0%) with P. malariae, and 140 (56.9%) negative. Sensitivity for P. falciparum was 100% and specificity was 96.2% (200 of 208; 95% confidence interval [CI] = 92-98). For P. vivax, sensitivity was 87.3% (55 of 63; 95% CI = 77-93) and specificity was 97.7% (173 of 177; 95% CI = 95-99), but all the four false-positive results were microscopically positive for P. malariae; thus, specificity for non-falciparum Plasmodium was 100%. These results suggest improved performance over NOW ICT predecessors.

Adult↗

Dependence of malaria detection and species diagnosis by microscopy on parasite density.

Giemsa-stained blood smears from each of 2,190 patients from Thai government-operated clinics on the Thailand-Myanmar border were independently examined by the on-duty microscopists at the clinics and by 2-3 research microscopists, each blinded to the clinics' and each other's reports. Using a strictly defined protocol, a consensus reference-standard blood smear interpretation for each sample was produced by the research microscopists. This result was compared with the clinic's diagnostic interpretation for the corresponding sample with respect to detection of parasitemia and diagnosis of infecting species. Reference-standard results reported parasitemia in 13.2% of the samples reported negative by the clinic. Reference-standard results were negative in 24.3% of the samples reported parasite-positive by the clinic. For samples in which both the reference-standard result and the clinic result reported parasitemia, species identification differed for 13.7% of the samples. The likelihood of parasite detection and correct diagnosis at the clinic varied in accordance with the reference-standard estimates of parasite density.

Adolescent↗