PubMed Health⌕ Search

Biomedical subjects

Robert A Reed

Publications and source records attributed to Robert A Reed.

At least 19 recordsLinked to original sources

Evaluation of hydroperoxides in common pharmaceutical excipients.

While the physical properties of pharmaceutical excipients have been well characterized, impurities that may influence the chemical stability of formulated drug product have not been well studied. In this work, the hydroperoxide (HPO) impurity levels of common pharmaceutical excipients are measured and presented for both soluble and insoluble excipients. Povidone, polysorbate 80 (PS80), polyethylene glycol (PEG) 400, and hydroxypropyl cellulose (HPC) were found to contain substantial concentrations of HPOs with significant lot-to-lot and manufacturer-to-manufacturer variation. Much lower HPO levels were found in the common fillers, like microcrystalline cellulose and lactose, and in high molecular weight PEG, medium chain glyceride (MCG), and poloxamer. The findings are discussed within the context of HPO-mediated oxidation and formulating drug substance sensitive to oxidation. Of the four excipients with substantial HPO levels, povidone, PEG 400, and HPC contain a mixture of hydrogen peroxide and organic HPOs while PS80 contains predominantly organic HPOs. The implications of these findings are discussed with respect to the known manufacturing processes and chemistry of HPO reactivity and degradation kinetics. Defining critical HPO limits for excipients should be driven by the chemistry of a specific drug substance or product and can only be defined within this context.

Cellulose↗

Identification of impurities in ivermectin bulk material by mass spectrometry and NMR.

The identification and characterization of four process impurities in bulk ivermectin and four process impurities in bulk avermectin, using a combination of MS and NMR, are discussed herein. These process impurities were shown to be 24-demethyl H2B1a, 3'-demethyl H2B1a, 3''-demethyl H2B1a and 24a-hydroxy B2a isomer. The impurities were shown to be process impurities and are present in avermectin bulk also.

Drug Contamination↗

Polysorbate 80 UV/vis spectral and chromatographic characteristics--defining boundary conditions for use of the surfactant in dissolution analysis.

Polysorbate 80 is used in the pharmaceutical industry as an additive to enhance the solubility of non-polar compounds in formulation design and during dissolution analysis. In this paper we present the spectroscopic and chromatographic characteristics for a series of commercially available sources of this non-ionic surfactant. The large UV/vis absorbance and broad chromatographic elution of Polysorbate 80 often makes it difficult to accurately quantitate pharmaceutically active compounds in solutions where the surfactant is present. Boundary conditions have been established where analytical interferences can be avoided in spectrophotometric analysis by choice of analysis wavelength and solution concentrations. Chromatographic method development is also presented enabling the removal of Polysorbate interference in instances where spectroscopic interference is too great.

Chromatography, High Pressure Liquid↗

Detection and quantification of low-molecular-weight aldehydes in pharmaceutical excipients by headspace gas chromatography.

The adverse effect of reactive chemical residues on the quality of drug products has necessitated the determination of low-molecular-weight aldehydes in pharmaceutical excipients. An analytical methodology for the detection of trace amounts of C1-C8 aliphatic aldehydes and benzaldehyde in excipients is described. The proposed procedure is based on the derivatization of aldehydes in aqueous solution with O-2,3,4,5,6-(pentafluorobenzyl) hydroxylamine hydrochloride (PFBHA), followed by static headspace gas chromatographic (SHS-GC) analysis of PFBHA aldehyde oximes with negative chemical ionization (NCI) MS detection. The method developed was demonstrated to be simple, selective, sensitive, and was successfully applied to the screening of aldehydes at sub-microg/g levels in over 30 typical excipients. The most abundant aldehydes found in the samples were formaldehyde and acetaldehyde, for which a rapid and reliable routine quantification method by readily available SHS-GC instrumentation coupled with flame-ionization detection was also developed and validated.

Aldehydes↗

Evaluation of solution oxygenation requirements for azonitrile-based oxidative forced degradation studies of pharmaceutical compounds.

AIBN and ACVA oxidative forced degradation models are examined for two drug molecules whose predominant oxidation chemistries arise from different reaction mechanisms (i.e., free radical vs. nucleophilic). Stress was conducted under a variety of initiator concentrations, and under ambient and pressurized oxygen atmospheres. In each case examined, the azonitrile initiator solutions served as a good predictive model of the major oxidative degradation products observed in pharmaceutical formulations. At low to moderate inititator concentrations, the degradation product distributions and degree of reactivity were similar for samples stored in ambient and pressurized oxygen environments. These results are rationalized with reference to the oxygen consumption kinetics of AIBN and ACVA solutions as a function of initiator concentration. The data suggests that ambient air provides sufficient oxygen to enable chain propagation of peroxy radicals in azonitrile solutions of concentrations appropriate to the forced degradation of pharmaceutical compounds.

Acetonitriles↗

Nucleophilic group transfer reactivity for fibric acid derived drug molecules.

A novel group transfer reaction is reported in which a drug molecule undergoes a thermally induced 2-methyl-2-yl-propionic acid group transfer from one drug molecule to the carboxylic acid functional group of another. The resulting product, the 2-carboxy isopropyl ester of the parent compound, can itself participate in further reactions to yield a series of homologous products. The structural requirements and solvent dependence of this reactivity were investigated, and the resulting implications for the reaction mechanism were discussed. The experimental data is consistent with solvent-assisted nucleophilic substitution reaction mechanism, where the solvent is a small molecule or a second drug molecule. Hydrogen bonding appears to play an important role in both intramolecular activation of the leaving group, as well as intermolecular interaction with the attacking nucleophile. The reactivity is found to be intrinsic to the 2-arenoxy-2-methylpropionic acid structure, which is common to the extended class of fibrate PPAR drug molecules, suggesting that the potential for this reactivity exists for many of these drug molecules as well.

Chemical Phenomena↗

A novel peroxy radical based oxidative stressing system for ranking the oxidizability of drug substances.

A novel oxidative stressing system is described which generates high levels of peroxy radicals in solution at room temperature, without the use of azonitrile initiators. The oxidative stressing system is composed of a 10% solution of Tween 80 in water to which FeCl3 x 6H2O is added. The Tween 80 acts as a solubilizing agent for drug compounds, and also contains substantial amounts of organic hydroperoxides. It is shown that the Fe III/ Fe II couple operates on the hydroperoxide concentration to effectively generate new peroxy radicals, which then propagate in the Tween 80 solution. Key features of the Tween 80/Fe III system are investigated, and the oxidizability of seven known compounds and ten developmental compounds are examined. Relative reaction rates span a 300-fold range, from benzoic acid (nonreactive, defined as <0.5% reacted per day) to Vitamin D3 (7% reacted per hour). Oxidizability "rankings" thus generated are shown to agree well with azonitrile initiated oxidative stress. The potential for general correlations between this type of oxidizability data and actual oxidative performance in LFC and solid oral dosage forms is discussed.

Chlorides↗

Profiling of medium chain glycerides used in pharmaceutical formulation development by reversed-phase HPLC.

Medium chain length (C8, C10) mono-, di- and triacylglycerols (MCGs) are used in pharmaceutical formulation development of poorly soluble compounds, as a means to increase their oral bioavailability. The ratios of C8 and C10 fatty acid components along with the ratio of monoglycerides, diglycerides and triglycerides can significantly impact overall solubilizing characteristics both in vitro and in vivo. Existing literature methods either do not have the desired selectivity or simplicity to adequately characterize these MCGs. A reversed-phase HPLC method has been developed utilizing a Waters Symmetry C18 (150 mm x 4.6 mm, 3.5 microm particle size) column with a gradient of acetonitrile and water. The effluent was monitored using a UV detector at 220 nm and relative response factors were determined for all components with available standards to allow for accurate quantitation. The RP-HPLC method was optimized for selectivity, sensitivity and efficiency and was successfully applied to the characterization of commercial samples yielding superior sensitivity and ease of preparation compared to existing compendial methods.

Chemistry, Pharmaceutical↗

Mechanism of the solution oxidation of rofecoxib under alkaline conditions.

PURPOSE: The rapid oxidation of rofecoxib under alkaline conditions has been previously reported. The oxidation was reported to involve gamma-lactone ring opening to an alcohol, which further oxidized to a dicarboxyclic acid. The oxidation was suspected to be mediated by peroxy radicals. This work further investigates the mechanism of oxidation under the alkaline solution conditions. METHODS: The pH dependence of the oxidation reaction was determined in 50% acetonitrile/50% aqueous phosphate buffer (pH 9-12). The oxidation reaction products were also examined at early timepoints (from 40 s to several minutes) with only 5% water content. The evolution of hydrogen peroxide by the oxidation reaction was quantitatively followed by reaction with triphenylphosphine (TPP) and high-pressure liquid chromatography determination of the resultant triphenylphosphine oxideformed. Rofecoxib was exposed to the alkaline pH conditions in the presence of formaldehyde, and the primary reaction product was isolated and characterized by liquid chromatography-mass spectrometry and proton 1D, heteronuclear multiple quantum coherence (HMQC), gradient heteronuclear multiple bond correlation (gHMBC), and carbon 1D nuclear magnetic resonance techniques. Transient reaction products were examined for hydroperoxide groups by reaction with TPP. RESULTS: The oxidation reaction occurs only near pH 11 and above. In the presence of excess formaldehyde, oxidation products are no longer observed but a new product is observed in which two formaldehyde molecules have added to the methylene carbon atom of the gamma-lactone ring. The evolution of hydrogen peroxide corresponds quantitatively to the molar amount of the (minor) aldehyde oxidation product formed. It is demonstrated that the rofecoxib anhydride species is actually the primary product of the oxidation reaction. The existence of a transient hydroperoxide species is shown by reaction with TPP and concomitant conversion to a previously identified alcohol. CONCLUSIONS: The oxidation of rofecoxib under these high pH conditions is mediated by rofecoxib enolate ion formation. The enolate ion reacts with either formaldehyde or dissolved oxygen at the C5 position. In the case of oxygen, a transient hydroperoxide species is formed. The major and minor products of the oxidation derive from competitive routes of decomposition of this hydroperoxide. The major route involves a second enolate ion formation, which decomposes with heterolytic cleavage of the RO-OH bond to give the rofeocoxib anhydride and hydroxide ion. The anhydride is rapidly hydrolyzed under the alkaline conditions to give the observed rofecoxib dicarboxylate product. The minor hydroxy-furanone product is formed from hydroxide ion attack on the hydroperoxide intermediate.

Alkalies↗

In-line monitoring of moisture content in fluid bed dryers using near-IR spectroscopy with consideration of sampling effects on method accuracy.

In-line near-IR moisture monitoring of the dynamic, fluid bed drying environment has been reported in recent years by several research groups; however, analytical figures of merit with regard to prediction accuracy are discussed in only a subset of this work, and issues with sampling and sample presentation are scarcely addressed at all. In this study, experiments were performed at 65-, 300-, and 600-L drying scales using several different sampling configurations in an effort to better understand and improve in-line near-IR method accuracy. Findings from this work demonstrate that process heterogeneity plays a major role in determination of apparent prediction accuracy. This aspect is general to all in-line measurements and plays an especially important role in solids and slurry systems that are prone to heterogeneity. In addition to experimental results, simulations based on these findings and sampling theory demonstrate an interesting paradox: depending on the sampling configuration employed, the method with the smallest apparent error is not necessarily optimal for process monitoring and control. Furthermore, sampling configuration influences the number of samples necessary to define an adequate calibration set. Finally, process understanding that was gained as a result of temporally rich, in-line measurements will be presented.

Journal Article↗

Rapid, simultaneous determination of headspace oxygen and moisture in pharmaceutical packages using muGC.

The rapid, accurate determination of headspace oxygen and moisture in various pharmaceutical packages is important for both product packaging development and the implementation of new packaging technologies. Current headspace oxygen measurement techniques suffer from serious drawbacks in terms of potential sampling contamination, lengthy analysis times, and large required analysis volumes. In addition, relatively few techniques currently exist for the convenient determination of headspace moisture in packaging systems. Efforts herein focused on the development and application of a new method for the rapid and simultaneous determination of headspace oxygen and moisture in pharmaceutical packages using micro-gas chromatography (muGC). Studies showed that both headspace oxygen and moisture could be simultaneously quantified in <90 s on sample volumes of 50-100 microL by employing muGC with dual chromatographic analysis modules. Sampling issues common to manual syringe-based injections were also alleviated in the current studies by use of the built-in diaphragm pump sampling interface of the portable muGC system. The performance of the analytical approach was evaluated and shown to exhibit excellent linearity, accuracy, and precision for both analytes. High sensitivity for headspace oxygen was demonstrated, allowing for levels of oxygen as low as 0.03% to be accurately quantified. The subject method was applied to measure the headspace oxygen and moisture in pharmaceutical blister packaging and glass vials.

Chromatography, Gas↗

The effect of inert atmospheric packaging on oxidative degradation in formulated granules.

PURPOSE: Oxidative degradation of drug substances in pharmaceutical products is well documented and is thought to occur in many cases via autoxidative processes involving headspace molecular oxygen in the primary package. Reducing the headspace oxygen concentration inside a package could thus be an option for reducing oxidative degradation in pharmaceutical products. The purpose of this study is to examine the effect of headspace oxygen concentration and relative humidity (RH) on the oxidative degradation of a model pharmaceutical formulation. METHODS: Model formulations, including a drug substance known to exhibit oxidative degradation, at two different drug/excipient ratios were packaged in stoppered glass vials maintained at different oxygen concentrations, (from 0% to 20.9%) and headspace relative humidities and were stored at 40 degrees C. The oxidative degradation was quantified as a function of time. RESULTS: The results clearly show dependence of oxidative degradation on headspace oxygen concentration, relative humidity, drug loading and time. CONCLUSIONS: The results provided insight into the effectiveness of inert atmospheric packaging (IAP) for protecting oxidation-labile products. In light of these observations, a few strategies for practically implementing inert atmosphere packaging are also presented.

Chemistry, Pharmaceutical↗

Planning environmental sanitation programmes in emergencies.

Environmental sanitation programmes are vital for tackling environmental-related disease and ensuring human dignity in emergency situations. If they are to have maximum impact they must be planned in a rapid but systematic manner. An appropriate planning process comprises five key stages: rapid assessment and priority setting; outline programme design; immediate action; detailed programme design; and implementation. The assessment should be based on carefully selected data, which are analysed via comparison with suitable minimum objectives. How the intervention should be prioritised is determined through objective ranking of different environmental sanitation sector needs. Next, a programme design outline is produced to identify immediate and longer-term intervention activities and to guarantee that apposite resources are made available. Immediate action is taken to meet acute emergency needs while the detailed programme design takes shape. This entails in-depth consultation with the affected community and comprehensive planning of activities and resource requirements. Implementation can then begin, which should involve pertinent management and monitoring strategies.

Disasters↗

Restoring sanitation services after an earthquake: field experience in Bam, Iran.

A powerful earthquake hit the city of Bam in southeast Iran on 26 December 2003. In its aftermath, a number of international relief agencies, including Oxfam, assisted in providing emergency sanitation services. Oxfam's programme consisted of constructing and repairing toilets and showers in villages located outside of the city. In contrast with other organisations, Oxfam opted for brick-work structures, using local materials and human resources rather than prefabricated cubicles. The choice illustrates the dilemmas faced by agencies involved in emergency sanitation: responding to needs in a manner consistent with international standards and offering assistance in a timely fashion while involving beneficiaries. Following a preliminary survey, Oxfam concluded that the provision of showers and latrines, in addition to utilisation of local materials and human resources, was essential for ensuring well-being, empowerment and dignity among members of the affected population, thereby maximising the benefits.

Disaster Planning↗

Monitoring of a pharmaceutical nanomilling process using grating light reflection spectroscopy.

An optical diagnostic method, grating light reflection spectroscopy (GLRS), has been demonstrated for the in situ monitoring of properties of heterogeneous matrices in industrial processes. The technique is based on measurements near the critical points of intensity and phase in waves reflected from a transmission diffraction grating in contact with a diagnostic sample. The features contained in the reflection spectrum near these thresholds allow for the simultaneous determination of the real and imaginary parts of the dielectric function of the sample. Using these data, the milling progress of highly concentrated fluid suspensions is observed as the material is milled from approximately 40 mm to 160 nm in diameter. A theoretical model that closely resembles experimentally determined spectra was constructed and applied in combination with principal components analysis (PCA) to demonstrate that GLRS can be used to closely monitor changes in the mean particle size of the nanomilled drug product.

Algorithms↗

Comparison of near-infrared and laser-induced breakdown spectroscopy for determination of magnesium stearate in pharmaceutical powders and solid dosage forms.

Near-infrared (NIR) spectroscopy has become well established in both the pharmaceutical arena and other areas as a useful technique for rapid quantitative analysis of solid materials. Though laser-induced breakdown spectroscopy (LIBS) has not been widely applied in the pharmaceutical industry, the technique has been used for rapid quantitative analysis of solids in many other applications. One analysis amenable to each technique is the determination of magnesium stearate in solids during the lubrication blending unit operation of pharmaceutical processing. A comparative study of the utility of these two techniques for this application will be presented. Necessary sample preparations and the extent and type of matrix effects will be discussed. Additionally, it will be shown that NIR provides better accuracy and precision than LIBS with the experimental parameters used; however, LIBS showed superior selectivity as it was demonstrated to be more robust to sample matrix perturbations. Examples of blending applications will also be presented.

Drug Compounding↗

Building a campus crisis team.

Crisis events can produce waves of shock, fear, and disbelief throughout a community. The university campus is a community and no stranger to crisis events. Incidents such as natural disasters, bus accidents, fire, and death on campus have demonstrated this fact. Communities, including the university, are becoming more aware of the need to develop plans to respond to these crisis events. Communities that are prepared to respond to such events may moderate the impact that the crisis has on a community. This article discusses the issues confronted by a small liberal arts university's faculty and staff as they worked together to develop and sustain a crisis response team.

Cooperative Behavior↗

Development and validation of a stability indicating HPLC method for determination of lisinopril, lisinopril degradation product and parabens in the lisinopril extemporaneous formulation.

The purpose of the research described herein was to develop and validate a stability-indicating HPLC method for lisinopril, lisinopril degradation product (DKP), methyl paraben and propyl paraben in a lisinopril extemporaneous formulation. The method developed in this report is selective for the components listed above, in the presence of the complex and chromatographically rich matrix presented by the Bicitra and Ora-Sweet SF formulation diluents. The method was also shown to have adequate sensitivity with a detection limit of 0.0075 microg/mL (0.03% of lisinopril method concentration). The validation elements investigated showed that the method has acceptable specificity, recovery, linearity, solution stability, and method precision. Acceptable robustness indicates that the assay method remains unaffected by small but deliberate variations, which are described in ICH Q2A and Q2B guidelines.

Chemistry, Pharmaceutical↗