PubMed Health⌕ Search

Biomedical subjects

Robert C Habbersett

Publications and source records attributed to Robert C Habbersett.

2 recordsLinked to original sources

Probing the kinetics of SYTOX Orange stain binding to double-stranded DNA with implications for DNA analysis.

Rapid binding kinetics of SYTOX Orange stain with double-stranded DNA (dsDNA) was revealed on the DNA fragment sizing flow cytometer. We demonstrated for the first time that the dye molecules could be adsorbed onto the capillary surface and native DNA fragments can be dynamically stained while passing through the capillary. High-quality burst size distribution histograms were obtained for DNA samples analyzed immediately after staining, dilution, or mixing. These observations indicated that rapid interactions exist between SYTOX Orange dye molecules and dsDNA. A stopped-flow fluorescence apparatus was set up to capture the fast association traces of intercalating dyes binding to dsDNA. Kinetic equations were derived to fit the association curves for determination of association rates and to model the dynamic staining, dilution, and mixing processes of DNA samples stained with intercalating dyes. The measured association rates for both SYTOX Orange and PicoGreen stains intercalating into dsDNA were on the order of 10(8) M-1 s-1, suggesting a diffusion-controlled process. Simulations indicate that reequilibration can be reached in seconds upon staining, dilution, or mixing. Insight into the kinetics of DNA binding dyes will help implement efficient sample-handling practices in DNA analysis, including DNA fragment sizing flow cytometry.

Binding Sites↗

An analytical system based on a compact flow cytometer for DNA fragment sizing and single-molecule detection.

BACKGROUND: Previous reports have demonstrated accurate DNA fragment sizing of linear DNA fragments, from 564 to approximately 4 x 10(5) bp, in a flow system. B-phycoerythrin (B-PE), commonly used in conventional cytometric applications that require high-sensitivity, was the first fluorophore detected in flow at the single-molecule level. METHODS: Dilute solutions of stained DNA fragments or B-PE were analyzed in a simplified, compact flow system, with enhanced performance and lower cost, utilizing a solid-state laser and a single-photon sensing avalanche photodiode detector (SSAPD). Extensive data processing and display software, developed specifically for the photon-counting data stream, extracts correlated height, width, and area features from bursts of photons due to discrete molecules passing through the sensing region in the flow channel. RESULTS: DNA fragment sizing in flow has now been demonstrated for SYTOX-orange-stained fragments ranging in size over 3.4 orders of magnitude, from 125 to 5 x 10(5) bp. For Lambda bacteriophage DNA (lambda DNA; 48.5 kbp) a CV of 1.2 % has been achieved. Analysis of a femtomolar B-PE solution demonstrates that the bursts of photons from individual molecules can be baseline-resolved with 0.5 mW of laser power at a signal to noise ratio (SNR) of approximately 30, with approximately 100 photons detected from each molecule. CONCLUSIONS: A compact, low-power, high-sensitivity system detects DNA fragments as small as 125 bp or individual B-PE molecules in a flowing liquid stream. Demonstrated linearity, sensitivity, and resolution indicate that <1.0 mW of laser power is optimal, permitting further miniaturization of the system and additional cost reduction. Comprehensive analytical software exploits the standard cytometric paradigm of multiple 2D graphs and gating to extract features from classes of individually analyzed biomolecules. This complete system is thus poised to engage high-sensitivity applications not amenable to conventional flow cytometric instrumentation.

DNA↗