PubMed Health⌕ Search

Biomedical subjects

Robert D'Angelo

Publications and source records attributed to Robert D'Angelo.

7 recordsLinked to original sources

Dural puncture with a 27-gauge Whitacre needle as part of a combined spinal-epidural technique does not improve labor epidural catheter function.

BACKGROUND: This prospective, double-blind, randomized study was designed to examine whether the combined spinal-epidural technique without subarachnoid drug administration improved epidural catheter function when compared with the traditional epidural technique. METHODS: After institutional review board approval and informed consent, 251 healthy laboring parturients were randomly assigned to either group DP (combined spinal-epidural technique with 27-gauge Whitacre needle dural puncture but without subarachnoid drug administration) or group NoDP (traditional epidural technique). Patient-controlled epidural analgesia was initiated with 0.11% bupivacaine and 2 microg/ml fentanyl. Top-up doses in 5-ml increments of 0.25% bupivacaine were administered if needed. Previous power analysis revealed that a sample size of 108 patients/group was needed to show a clinically useful reduction of the catheter manipulation rate from 32% to 15%. RESULTS: In groups DP and NoDP, 107 and 123 evaluable patients, respectively, completed the study. Demographics and outcome variables measured, including epidural catheter manipulation and replacement rate, sacral sparing, unilateral block, number of top-up doses, average hourly epidural drug usage, highest sensory blockade level, and labor analgesia quality, were not different between groups. A subgroup of 18 patients without cerebral spinal fluid return during dural puncture had a higher catheter replacement rate than those of groups DP and NoDP, but it did not reach statistical significance. CONCLUSIONS: Dural puncture with a 27-gauge Whitacre needle without subarachnoid drug administration during combined spinal-epidural labor analgesia did not improve epidural labor analgesia quality or reduce catheter manipulation or replacement rate when compared with a traditional epidural technique.

Adult↗

Ropivacaine 0.075% and bupivacaine 0.075% with fentanyl 2 microg/mL are equivalent for labor epidural analgesia.

UNLABELLED: Fifty percent effective dose estimates for ropivacaine and bupivacaine suggest that ropivacaine is 40% less potent than bupivacaine to initiate labor analgesia. At clinically used concentrations, however, the drugs seem indistinguishable for initiating and maintaining labor analgesia. We designed this study to evaluate a concentration near the reported 50% effective dose values for ropivacaine and bupivacaine in an attempt to detect differences between the drugs during routine clinical use. Fifty-nine nulliparous women in labor were randomized to receive 0.075% ropivacaine or bupivacaine, each with fentanyl 2 microg/mL. After epidural placement and the administration of a lidocaine/epinephrine test dose, 20 mL of study solution was administered and a patient-controlled epidural infusion was initiated with the following settings: 6 mL/h basal rate, 5 mL bolus, 10 min lockout, and 30 mL/h limit. Breakthrough pain was treated with 10-mL boluses of study solution. By using a study design to detect a 40% difference in hourly drug use between groups, we found no statistically significant differences in the amount of local anesthetic used, verbal pain scores, sensory levels, motor blockade, labor duration, mode of delivery, side effects, or patient satisfaction. We conclude that 0.075% ropivacaine and bupivacaine, with fentanyl, are equally effective for labor analgesia using the patient-controlled epidural analgesia technique. IMPLICATIONS: At small concentrations, ropivacaine and bupivacaine when combined with fentanyl are equally effective for labor analgesia. Patients self-administered similar volumes of 0.075% ropivacaine or bupivacaine solutions containing fentanyl (2 microg/mL) suggesting that at this concentration, and with the addition of fentanyl, ropivacaine and bupivacaine can be used interchangeably.

Adult↗

A comparison of intrathecal fentanyl and sufentanil for labor analgesia.

BACKGROUND: The use of intrathecal opioids for labor analgesia continues to gain popularity, but there are limited data to guide this use. Previously, the authors established the ED50 for 60 min of labor analgesia from intrathecal sufentanil using an up-down sequential allocation study design. The current study first establishes an ED50 for intrathecal fentanyl using this same study design to establish an intrathecal potency ratio for fentanyl and sufentanil and then uses this ratio to compare the efficacy, duration of analgesia, and side effects from comparable doses of intrathecal fentanyl and sufentanil. METHODS: Seventy-five healthy nulliparous women requesting labor analgesia were enrolled in this two-part study. In phase I, 20 women received varying doses of fentanyl to establish an ED50 for 60 min of labor analgesia. In phase II, 55 women were randomized to receive either 36 microg intrathecal fentanyl or 8 microg sufentanil (2 times the ED50s) via a combined spinal-epidural technique and by double-blinded design. Pain relief, side effects, block height, maternal hemodynamics, and fetal heart rate were assessed throughout the study. The duration of spinal analgesia was considered to be the time from injection of study drug to the time of the patient's first request for additional analgesia. RESULTS: The ED50 of intrathecal fentanyl for 60 min of labor analgesia was found to be 18.2 microg, and therefore, the potency ratio of intrathecal sufentanil to intrathecal fentanyl at the ED50 level is 4.4:1. The duration of spinal analgesia was significantly longer from 8 microg intrathecal sufentanil than from 36 microg intrathecal fentanyl (104 +/- 34 vs. 79 +/- 34 min, P = 0.009). Otherwise, patient demographics, maternal hemodynamics, duration of labor, mode of delivery, motor block, subjective leg weakness, pruritus, nausea, pinprick sensory levels, visual analog scale pain scores, fetal bradycardia, and Apgar scores were similar between groups. CONCLUSION: The relative potency of intrathecal sufentanil to fentanyl for labor analgesia is 4.4:1. When using intrathecal opioids alone for early labor analgesia, 8 microg sufentanil produces labor analgesia lasting approximately 25 min longer than from 36 microg fentanyl, without a statistically significant increase in side effects. However, when making a choice between fentanyl and sufentanil, one must consider other important factors, such as the higher cost of sufentanil and the greater risk of dosing error due to the higher potency of sufentanil compared with fentanyl.

Adult↗