PubMed Health⌕ Search

Biomedical subjects

Robert E Koehler

Publications and source records attributed to Robert E Koehler.

2 recordsLinked to original sources

Computerized tomographic colonography: performance evaluation in a retrospective multicenter setting.

BACKGROUND & AIMS: No multicenter study has been reported evaluating the performance and interobserver variability of computerized tomographic colonography. The aim of this study was to assess the accuracy of computerized tomographic colonography for detecting clinically important colorectal neoplasia (polyps >or=10 mm in diameter) in a multi-institutional study. METHODS: A retrospective study was developed from 341 patients who had computerized tomographic colonography and colonoscopy among 8 medical centers. Colonoscopy and pathology reports provided the standard. A random sample of 117 patients, stratified by criterion standard, was requested. Ninety-three patients were included (47% with polyps >or=10 mm; mean age, 62 years; 56% men; 84% white; 40% reported colorectal symptoms; 74% at increased risk for colorectal cancer). Eighteen radiologists blinded to the criterion standard interpreted computerized tomography colonography examinations, each using 2 of 3 different software display platforms. RESULTS: The average area under the receiver operating characteristic curve for identifying patients with at least 1 lesion >or=10 mm was 0.80 (95% lower confidence bound, 0.74). The average sensitivity and specificity were 75% (95% lower confidence bound, 68%) and 73% (95% lower confidence bound, 66%), respectively. Per-polyp sensitivity was 75%. A trend was observed for better performance with more observer experience. There was no difference in performance across software display platforms. CONCLUSIONS: Computerized tomographic colonography performance compared favorably with reported performance of fecal occult blood testing, flexible sigmoidoscopy, and barium enema. A prospective study evaluating the performance of computerized tomography colonography in a screening population is indicated.

Colonic Neoplasms↗

Double reading of barium enemas: is it necessary?

OBJECTIVE: The purpose of our study was to determine the effectiveness, clinical impact, and feasibility of double reading barium enemas. MATERIALS AND METHODS: Independent double readings of 1,003 consecutive barium enemas (822 double- and 181 single-contrast examinations) were prospectively performed. From this pool of 1,003 examinations, 994 were included in our study. Examinations showing at least one polyp or carcinoma 5 mm or larger were considered to have positive results. For combined readings, results were considered positive if either of the two interpreters reported finding a polyp or carcinoma. A McNemar test was used to compare the first reader's results with the combined results of the first and second readers. Results were retrospectively correlated with endoscopic or surgical results in 360 patients, and agreement between first and combined readings and endoscopic results was determined. RESULTS: Adding a second reader increased the number of positive results on examinations from 249 to 315 (p < 0.0001) and resulted in potential alteration of clinical treatment in 98 patients (9.9%). Sensitivity of the first and combined readings for detection of all lesions was identical, 76.3% (95% CI, 65.4-87.1%). Specificity decreased from 91.0% (95% CI, 87.9-94.3%) for the first reading to 86.4% (95% CI, 82.2-90.0%) for the combined reading. The overall measurement of agreement decreased from a kappa value of 61.8 (95% CI, 51.2-72.4%) for the first reading to 52.9 (95% CI, 42.2-63.6%) for the combined reading. The second reading required an average of 3.3 min. Sensitivity for the detection of adenocarcinomas was 100%. CONCLUSION: Although feasible, double reading of barium enemas does not improve sensitivity for detection of polyps and produces a higher false-positive rate.

Adult↗