Radiation dose to the fetus from body MDCT during early gestation.

OBJECTIVE: The purpose of our study was to determine radiation dose to the fetus at early gestation when contemporary MDCT scanners are used for common clinical indications. MATERIALS AND METHODS: Anthropomorphic phantoms were constructed to reflect a pregnant woman. Thermoluminescence dosimeters (TLDs) and metal oxide semiconductor field effect transistor (MOSFET) detectors were placed in appropriate locations to determine real-time radiation exposure to the fetus at 0 and 3 months' gestation. Imaging was performed on a 16-MDCT scanner using current institutional CT protocols: renal stone (140 kVp, 160 mA, rotation time of 0.5 sec, 16 x 0.625 mm), appendix (140 kVp, 340 mA, rotation time of 0.5 sec, 16 x 0.625 mm), and pulmonary embolus (140 kVp, 380 mA, rotation time of 0.8 sec, 16 x 1.25 mm). RESULTS: The radiation dose to the fetus at 0 and 3 months, respectively, was as follows: renal stone protocol, 0.8-1.2 and 0.4-0.7 cGy; appendix protocol, 1.52-1.68 and 2-4 cGy; and pulmonary embolus protocol, 0.024-0.047 and 0.061-0.066 cGy. CONCLUSION: Radiation doses to the fetus from institutional MDCT protocols that may be used during pregnancy (for pulmonary embolus, appendicitis, and renal colic) are below the level thought to induce neurologic detriment to the fetus. Imaging the mother for appendicitis theoretically may double the fetal risk for developing a childhood cancer. Radiation doses to the fetus from pulmonary embolus chest CT angiography are of the same magnitude as ventilation-perfusion (V/Q) scanning.

Female↗

Radiation dose to the female breast from 16-MDCT body protocols.

OBJECTIVE: The objective of our study was to determine the radiation dose to the female breast from current 16-MDCT body examinations. MATERIALS AND METHODS: Metal oxide semiconductor field effect transistor (MOSFET) detectors were placed in four quadrants of the breast of a female-configured anthropomorphic phantom to determine radiation dose to the breast. Imaging was performed on a 16-MDCT scanner (LightSpeed, GE Healthcare) using current clinical protocols designed to assess pulmonary embolus (PE) (140 kVp, 380 mA, 0.8-sec rotation, 16 x 1.25 mm collimation), appendicitis (140 kVp, 340 mA, 0.5-sec rotation, 16 x 0.625 mm collimation), and renal calculus (140 kVp, 160 mA, 0.5-sec rotation, 16 x 0.625 mm collimation). RESULTS: Radiation dose to the breast ranged from 4 to 6 cGy for the PE protocol and up to 1-2 cGy in the inferior aspect of the right breast and lateral aspect of the left breast for the appendicitis protocol. The renal calculus protocol yielded less than 150 microGy absorbed breast dose. CONCLUSION: Current clinical chest and abdomen protocols result in vairable radiation doses to the breast. The magnitude of exposure may have implications for imaging strategies.

Breast↗

Pharmacokinetics and radiation dosimetry of 18F-fluorocholine.

UNLABELLED: 18F-Fluorocholine (fluoromethyl-dimethyl-2-hydroxyethylammonium [FCH]) has been developed as an oncologic probe for PET. This study evaluates the kinetics and radiation dosimetry of 18F-FCH using murine and human biodistribution data. METHODS: The biodistribution of 18F-FCH was obtained at time points up to 10 h after administration in control and tumor-bearing anesthetized nude mice. Human biodistribution data within the first hour after injection were obtained from attenuation-corrected whole-body PET scans of male (n = 7) and female (n = 5) cancer patients. Radiation dosimetry estimates were calculated using the murine and human biodistribution data assuming no redistribution of tracer after 1 h. RESULTS: Rapid pharmacokinetics were observed for 18F-FCH in mice and humans. The biodistribution is nearly static after 10 min. The dose-critical organ is the kidney, which receives 0.17 +/- 0.05 and 0.16 +/- 0.07 mSv/MBq (0.64 +/- 0.18 and 0.55 +/- 0.32 rad/mCi) for females and males, respectively. The effective dose equivalent (whole body) from administration of 4.07 MBq/kg (0.110 mCi/kg) is approximately 0.01 Sv for females and males. CONCLUSION: 18F-FCH is rapidly cleared from the circulation and its biodistribution changes very slowly at >10 min after administration. The kidney is the dose-critical organ and limits administration levels of 18F-FCH to 4.07 MBq/kg (0.110 mCi/kg) in human research studies.

Animals↗