Diagnostic endoscopy: 2020 vision.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to Robert Ganz.
Explore the source record for details and available documents.
OBJECTIVES: This prospective, multicenter, single-arm study evaluated the safety and efficacy of the endoscopic implantation of Enteryx, a biocompatible, non-biodegradable liquid polymer for the treatment of GERD. METHODS: Eighty-five patients with heartburn symptoms responsive to proton pump inhibitor (PPI) use were enrolled. Inclusion requirements were HRQL score < or = 11 on PPI and > or = 20 off PPI, and 24-hour PH probe with > or = 5% total time at PH < or = 4. Patients with a hiatus hernia > 3 cm, grade 3 or 4 esophagitis, or esophageal motility disorder were excluded. Using a 4-mm needle tipped catheter during standard endoscopy, implants were made in 3-4 quadrants deep into the wall of the cardia. Use of PPI medications, pH-metry, manometry, GERD symptoms, and patient quality of life were assessed over a 6-month follow-up period. RESULTS: At 6 months, PPI use was eliminated in 74% and reduced by > 50% in 10% of patients. The median HRQL score improved from 24.0 pre-implant (baseline off PPIs) to 4.0 at 6 months (p < 0.001). Mean total esophageal acid exposure time was 9.5% pretherapy and 6.7% at 6 months (p < 0.001). Mean LES length increased from 2.0 cm at baseline to 3.0 cm posttherapy (p = 0.003). There were no clinically serious adverse events. Transient mild-to-moderate chest pain commonly occurred after implantation. CONCLUSIONS: The endoscopic implantation of Enteryx is a safe and effective therapy for eliminating or decreasing the need for PPI medications, improving GERD symptoms and patient quality of life, and decreasing esophageal acid exposure among patients suffering from GERD.
OBJECTIVES: This study aimed to assess the efficacy and safety of endoscopically implanting a nonresorbable biocompatible polymer (Enteryx) in the distal esophagus and proximal gastric cardia for the treatment of gastroesophageal reflux disease (GERD). METHODS: In a prospective, multicenter, international trial, 85 well-controlled GERD patients who were receiving chronic proton pump inhibitor (PPI) therapy underwent Enteryx implantation under fluoroscopic visualization, without general anesthesia. After the procedure, patients were discharged within approximately 2-4 h. Patients were judged to be treatment responders if after implantation they reduced PPI dosage by >/=50%. Follow-up evaluations were conducted at 1, 3, 6, and 12 months and included medication usage, symptoms, quality of life, endoscopy, pH monitoring, manometry, and documentation of adverse events. RESULTS: At 12 months, 80.3% (95% CI = 69.9%-88.3%) of 81 evaluable patients were treatment responders. Of the responders, 87.7% completely discontinued PPIs, and 12.3% reduced PPI dosage by >/=50%. Treatment response was more likely in patients with residual implant volume of >/=5 mL (p = 0.027). Other patient and treatment variables were not predictive. Both GERD heartburn and regurgitation symptom scores significantly improved at 12 months compared with baseline (p < 0.001). There were significant reductions in median supine, upright, and total percent time of esophageal exposure to pH <4. Endoscopically assessed esophagitis grades were unchanged. No serious adverse events were encountered. Transient retrosternal chest pain was experienced by 91.8% of patients. This pain was seldom severe and was typically successfully managed with prescription pain medication. CONCLUSIONS: Enteryx implantation allows most patients to discontinue PPI therapy, improves their symptoms, and reduces esophageal acid exposure. The effects of implantation are long-lasting, and morbidity is transient and minimal. The procedure requires basic endoscopic skills and seems to provide a useful option in the effective clinical management of GERD.