PubMed Health⌕ Search

Biomedical subjects

Robert Gunzburg

Publications and source records attributed to Robert Gunzburg.

At least 19 recordsLinked to original sources

Muscular contributions to dynamic dorsoventral lumbar spine stiffness.

Spinal musculature plays a major role in spine stability, but its importance to spinal stiffness is poorly understood. We studied the effects of graded trunk muscle stimulation on the in vivo dynamic dorsoventral (DV) lumbar spine stiffness of 15 adolescent Merino sheep. Constant voltage supramaximal electrical stimulation was administered to the L3-L4 interspinous space of the multifidus muscles using four stimulation frequencies (2.5, 5, 10, and 20 Hz). Dynamic stiffness was quantified at rest and during muscle stimulation using a computer-controlled testing apparatus that applied variable frequency (0.46-19.7 Hz) oscillatory DV forces (13-N preload to 48-N peak) to the L3 spinous process of the prone-lying sheep. Five mechanical excitation trials were randomly performed, including four muscle stimulation trials and an unstimulated or resting trial. The secant stiffness (k (y) = DV force/L3 displacement, kN/m) and loss angle (phase angle, deg) were determined at 44 discrete mechanical excitation frequencies. Results indicated that the dynamic stiffness varied 3.7-fold over the range of mechanical excitation frequencies examined (minimum resting k (y) = 3.86 +/- 0.38 N/mm at 4.0 Hz; maximum k (y) = 14.1 +/- 9.95 N/mm at 19.7 Hz). Twenty hertz muscle stimulation resulted in a sustained supramaximal contraction that significantly (P < 0.05) increased k (y) up to twofold compared to rest (mechanical excitation at 3.6 Hz). Compared to rest, k (y) during the 20 Hz muscle stimulation was significantly increased for 34 of 44 mechanical excitation frequencies (mean increase = 55.1%, P < 0.05), but was most marked between 2.55 and 4.91 Hz (mean increase = 87.5%, P < 0.05). For lower frequency, sub-maximal muscle stimulation, there was a graded change in k (y), which was significantly increased for 32/44 mechanical excitation frequencies (mean increase = 40.4%, 10 Hz stimulus), 23/44 mechanical excitation frequencies (mean increase = 10.5%, 5 Hz stimulus), and 11/44 mechanical excitation frequencies (mean increase = 4.16%, 2.5 Hz stimulus) when compared to rest. These results indicate that the dynamic mechanical behavior of the ovine spine is modulated by muscle stimulation, and suggests that muscle contraction plays an important role in stabilizing the lumbar spine.

Animals↗

Increased multiaxial lumbar motion responses during multiple-impulse mechanical force manually assisted spinal manipulation.

BACKGROUND: Spinal manipulation has been found to create demonstrable segmental and intersegmental spinal motions thought to be biomechanically related to its mechanisms. In the case of impulsive-type instrument device comparisons, significant differences in the force-time characteristics and concomitant motion responses of spinal manipulative instruments have been reported, but studies investigating the response to multiple thrusts (multiple impulse trains) have not been conducted. The purpose of this study was to determine multi-axial segmental and intersegmental motion responses of ovine lumbar vertebrae to single impulse and multiple impulse spinal manipulative thrusts (SMTs). METHODS: Fifteen adolescent Merino sheep were examined. Tri-axial accelerometers were attached to intraosseous pins rigidly fixed to the L1 and L2 lumbar spinous processes under fluoroscopic guidance while the animals were anesthetized. A hand-held electromechanical chiropractic adjusting instrument (Impulse) was used to apply single and repeated force impulses (13 total over a 2.5 second time interval) at three different force settings (low, medium, and high) along the posteroanterior axis of the T12 spinous process. Axial (AX), posteroanterior (PA), and medial-lateral (ML) acceleration responses in adjacent segments (L1, L2) were recorded at a rate of 5000 samples per second. Peak-peak segmental accelerations (L1, L2) and intersegmental acceleration transfer (L1-L2) for each axis and each force setting were computed from the acceleration-time recordings. The initial acceleration response for a single thrust and the maximum acceleration response observed during the 12 multiple impulse trains were compared using a paired observations t-test (POTT, alpha = .05). RESULTS: Segmental and intersegmental acceleration responses mirrored the peak force magnitude produced by the Impulse Adjusting Instrument. Accelerations were greatest for AX and PA measurement axes. Compared to the initial impulse acceleration response, subsequent multiple SMT impulses were found to produce significantly greater (3% to 25%, P < 0.005) AX, PA and ML segmental and intersegmental acceleration responses. Increases in segmental motion responses were greatest for the low force setting (18%-26%), followed by the medium (5%-26%) and high (3%-26%) settings. Adjacent segment (L1) motion responses were maximized following the application of several multiple SMT impulses. CONCLUSION: Knowledge of the vertebral motion responses produced by impulse-type, instrument-based adjusting instruments provide biomechanical benchmarks that support the clinical rationale for patient treatment. Our results indicate that impulse-type adjusting instruments that deliver multiple impulse SMTs significantly increase multi-axial spinal motion.

Journal Article↗

Spinal manipulation force and duration affect vertebral movement and neuromuscular responses.

BACKGROUND: Previous study in human subjects has documented biomechanical and neurophysiological responses to impulsive spinal manipulative thrusts, but very little is known about the neuromechanical effects of varying thrust force-time profiles. METHODS: Ten adolescent Merino sheep were anesthetized and posteroanterior mechanical thrusts were applied to the L3 spinous process using a computer-controlled, mechanical testing apparatus. Three variable pulse durations (10, 100, 200 ms, force = 80 N) and three variable force amplitudes (20, 40, 60 N, pulse duration = 100 ms) were examined for their effect on lumbar motion response (L3 displacement, L1, L2 acceleration) and normalized multifidus electromyographic response (L3, L4) using a repeated measures analysis of variance. FINDINGS: Increasing L3 posteroanterior force amplitude resulted in a fourfold linear increase in L3 posteroanterior vertebral displacement (p < 0.001) and adjacent segment (L1, L2) posteroanterior acceleration response (p < 0.001). L3 displacement was linearly correlated (p < 0.001) to the acceleration response over the 20-80 N force range (100 ms). At constant force, 10 ms thrusts resulted in nearly fivefold lower L3 displacements and significantly increased segmental (L2) acceleration responses compared to the 100 ms (19%, p = 0.005) and 200 ms (16%, p = 0.023) thrusts. Normalized electromyographic responses increased linearly with increasing force amplitude at higher amplitudes and were appreciably affected by mechanical excitation pulse duration. INTERPRETATION: Changes in the biomechanical and neuromuscular response of the ovine lumbar spine were observed in response to changes in the force-time characteristics of the spinal manipulative thrusts and may be an underlying mechanism in related clinical outcomes.

Animals↗

Recombinant human bone morphogenetic protein-2: a novel osteoinductive alternative to autogenous bone graft?

Autogenous bone grafts from the iliac crest have long been the gold standard for repair and reconstruction of bone; however harvesting of the grafts from the iliac crest is associated with donor site morbidity, particularly chronic pain. The bone morphogenetic proteins (BMPs) are soluble bone matrix glycoproteins that induce the differentiation of osteoprogenitor cells into osteogenic cells and have the potential to act as autogenous bone graft substitutes. BMP-2, which can be produced with recombinant technology, is highly osteoinductive, inducing bone formation by stimulating the differentiation of mesenchymal cells into chrondroblasts and osteoblasts. At present, more than 1,000 patients have received rhBMP-2 in clinical trials for acute open tibial fracture and interbody fusion procedures for the treatment of degenerative disc disease. Data suggest that rhBMP-2 therapy may offer an effective alternative to autogenous bone graft for recalcitrant bone unions and spinal fusion, obviating donor site morbidity.

Animals↗

An overview of blood-sparing techniques used in spine surgery during the perioperative period.

The problems linked to blood loss and blood-sparing techniques in spine surgery have been less studied than in other fields of orthopedics, such as joint-replacement procedures. Decreasing bleeding is not only important for keeping the patient's hemodynamic equilibrium but also for allowing a better view of the surgical field. In spine surgery the latter aspect is especially important because of the vicinity of major and highly fragile neurologic structures. The techniques and agents used for hemostasis and blood sparing in spinal procedures are mostly similar to those used elsewhere in surgery. Their use is modulated by the specific aspects of spinal approach and its relation to the contents of the spinal canal. Blood-sparing techniques can be divided into two categories based on their goals: either they are aimed at decreasing the bleeding itself, or they are aimed at decreasing the need for homologous transfusion. Various hemodynamic techniques, as well as systemic and local drugs and agents, can be used separately or in combination, and their use in the field of spine surgery is reported. The level of evidence for the efficacy of many of those methods in surgery as a whole is limited, and there is a lack of evidence for most of them in spine surgery. However, several blood-saving procedures and drugs, as well as promising new agents, appear to be efficient, although their efficacy has yet to be assessed by proper randomized controlled trials.

Blood Loss, Surgical↗

Biomechanical and neurophysiological responses to spinal manipulation in patients with lumbar radiculopathy.

OBJECTIVE: The purpose of this study was to quantify in vivo vertebral motions and neurophysiological responses during spinal manipulation. METHODS: Nine patients undergoing lumbar decompression surgery participated in this study. Spinal manipulative thrusts (SMTs) ( approximately 5 ms; 30 N [Sham], 88 N, 117 N, and 150 N [max]) were administered to lumbar spine facet joints (FJs) and spinous processes (SPs) adjacent to an intraosseous pin with an attached triaxial accelerometer and bipolar electrodes cradled around the S1 spinal nerve roots. Peak baseline amplitude compound action potential (CAP) response and peak-peak amplitude axial (AX), posterior-anterior (PA), and medial-lateral (ML) acceleration time and displacement time responses were computed for each SMT. Within-subject statistical analyses of the effects of contact point and force magnitude on vertebral displacements and CAP responses were performed. RESULTS: SMTs (>/= 88 N) resulted in significantly greater peak-to-peak ML, PA, and AX vertebral displacements compared with sham thrusts (P <.002). SMTs delivered to the FJs resulted in approximately 3-fold greater ML motions compared with SPs (P <.001). SMTs over the SPs resulted in significantly greater AX displacements compared with SMTs applied to the FJs (P <.05). Seventy-five percent of SMTs resulted in positive CAP responses with a mean latency of 12.0 ms. Collectively, the magnitude of the CAP responses was significantly greater for max setting SMTs compared with sham (P <.01). CONCLUSIONS: Impulsive SMTs in human subjects were found to stimulate spinal nerve root responses that were temporally related to the onset of vertebral motion. Further work, including examination of the frequency and force duration dependency of SMT, is necessary to elucidate the clinical relevance of enhanced or absent CAP responses in patients.

Adult↗

Prevention of hip lag screw cut-out by cement augmentation: description of a new technique and preliminary clinical results.

Cement augmentation of hip lag screws to avoid cut-out displacement is classically described, along with a number of technical drawbacks. In a series of six elderly patients with hip fractures in osteoporotic bone, we illustrate catheter-assisted delivery of limited amounts of a new bisphenol-a-glycidyl dimethacrylate (bis-GMA)-based composite into hip compression screw threads, enabling significant increase in insertional torque compared with unaugmented screws. In two patients, unaugmented screws that did not initially purchase were tightened with a minimum torque of 1 N-m after augmenting with bis-GMA-based composite. No screw or femoral head displacement relative to baseline (2 days postoperative) was seen in any patient on serial x-rays taken up to 6 months after surgery. This technique adds approximately 10 minutes to surgery time. Advantages of bis-GMA-based composite over traditional PMMA augmentation include mixing on-demand, the ability to make repeated injections over extended periods in the event of femoral head perforations (in one patient in this series), precise placement of adequately small volumes of material, and a lower exotherm. Potentially, this bis-GMA-based composite may reduce the frequency of cut-out complications by enhancing bone-implant interface.

Aged↗

Lumbar spinal stenosis in the elderly: an overview.

Lumbar spinal stenosis is a common condition in elderly patients and also one of the most common reasons to perform spinal surgery at an advanced age. Disc degeneration, facet degeneration and hypertrophy, and ligamentum flavum hypertrophy and calcification usually participate in the genesis of a stenotic condition in the elderly. These changes can lead to symptoms by themselves or decompensate a preexisting narrow canal. Although some lesions are more central or more lateral, this classic dichotomy is less present in the elderly patient, in whom the degenerative process usually encroaches both central and lateral pathways. Some less common causes of lumbar spinal stenosis are found in the aging subject, such as Paget's disease. However, it must be stressed that so-called stenotic images (sometimes severe) are present on imaging studies in a great number of symptom-free individuals, and that the relationship between degenerative lesions, importance of abnormal images, and complaints is still unclear. Lumbar stenosis is a very common reason for decompressive surgery and/or fusion. Various conditions can lead to a narrowing of the neural pathways and differential diagnosis with vascular troubles, also common in the elderly, can be challenging. The investigation of stenotic symptoms should be extremely careful and thorough and include a choice of technical examinations including vascular investigations. This is of utmost importance, especially if a surgical sanction is considered to avoid disappointing results.

Aged↗

The conservative surgical treatment of lumbar spinal stenosis in the elderly.

Canal stenosis is now the most common indication for lumbar spine surgery in elderly subjects. Degenerative disc disease is by far the most common cause of lumbar spinal stenosis. It is generally accepted that surgery is indicated if a well-conducted conservative management fails. A meta-analysis of the literature showed on average that 64% of surgically treated patients for lumbar spinal stenosis were reported to have good-to-excellent outcomes. In recent years, however, a growing tendency towards less invasive decompressive surgery has emerged. One such procedure, laminarthrectomy, refers to a surgical decompression involving a partial laminectomy of the vertebra above and below the stenotic level combined with a partial arthrectomy at that level. It can be performed through an approach which preserves a maximum of bony and ligamentous structures. Another principle of surgical treatment is interspinous process distraction This device is implanted between the spinous processes, thus reducing extension at the symptomatic level(s), yet allowing flexion and unrestricted axial rotation and lateral flexion. It limits the further narrowing of the canal in upright and extended position. In accordance with the current general tendency towards minimally invasive surgery, such techniques, which preserve much of the anatomy, and the biomechanical function of the lumbar spine may prove highly indicated in the surgical treatment of lumbar stenosis, especially in the elderly.

Aged↗

Assessment of trunk function in single and multi-level spinal stenosis: a prospective clinical trial.

OBJECTIVE: To clarify the biomechanical indicators of single- and multi-level stenosis and to determine the biomechanical outcome of selective conservative decompression. DESIGN: This study is a prospective clinical trial examining trunk function in spinal stenosis patients operated using a conservative procedure in an orthopaedic clinic. BACKGROUND: Although several clinical studies have examined the instability and motion characteristics of operated lumbar spinal canal stenosis, few if any studies have prospectively examined the biomechanical outcome of lumbar spinal canal stenosis surgery. METHODS: Comprehensive pre- and post-operative trunk dynamometer strength and motion analysis tests were performed on 36 patients operated for lumbar canal stenosis. Surgical treatment efficacy was evaluated within a three variable crossed factorial design considering stenosis classification, number of operative levels, and changes in several trunk biomechanical outcomes from pre- to post-operative assessment. Patients were evaluated after a minimum one-year follow-up. RESULTS: Pre-operatively there were no differential effects associated with stenosis classification or number of operated levels. There was a significant post-operative increase in isometric trunk extension torque and flexion-extension power and a return to a more normal trunk extension-flexion torque ratio. Patients with mixed, single level stenosis demonstrated greater trunk extension power both pre- and post-operatively compared to other patients. CONCLUSIONS: Conservative surgical treatment of lumbar spinal stenosis produced a marked improvement in the functional mechanical status of the low back. RELEVANCE: This study assists clinicians and researchers to understand trunk function following conservative surgical treatment of lumbar spinal stenosis.

Decompression, Surgical↗

Spine arthroplasty: a historical review.

Degenerative disc disease is one of the most frequently encountered spinal disorders. The intervertebral disc is a complex anatomic and functional structure, which makes the development of an efficient and reliable artificial disc a complex challenge. Not only is the disc function arduous to reproduce, but there are important consequences associated with the conception and the choice of materials that will have to bear the loads. Biochemical problems have complicated things even more. Two different principles have been applied in the realisation of a discal replacement: a metallic and/or polyethylene prosthesis allowing mainly mobility or a prosthesis enabling the reproduction of viscoelastic properties. Of course some devices attempt to combine both principles. In this paper we will try to present, in chronological order, an overview of the designs published in the literature as well as in the patents granted in this field. The very fact that such a long list of implants, based on highly varied principles, has been proposed, and that only very few have reached the level of animal models, let alone human implantation, clearly demonstrates how challenging the task of designing an intervertebral disc replacement is. Proper randomized controlled trials are now on the way, and should help in assessing the efficacy and real place of spine arthroplasty in the treatment of spinal disorders. Only then will spinal surgery join the list of successful joint replacements.

Arthroplasty↗

Use of a novel beta-tricalcium phosphate-based bone void filler as a graft extender in spinal fusion surgeries.

Synthetic bone void fillers are gaining acceptance as graft extenders in spinal surgery. One such product is an ultraporous formulation of nanometer-sized particles of beta-tricalcium phosphate (beta-TCP). An ongoing prospective open-label, randomized, observer-blinded, comparative study evaluated the efficacy and safety of a novel beta-TCP bone void filler as an additive to autogenous bone graft material in patients undergoing spinal fusion. Posterolateral instrumented or noninstrumented spinal fusion was performed at a single level or multiple levels with or without additional interbody fusion. Patients received autogenous bone on 1 side and autogenous bone augmented with extender (in a 1:1 ratio based on the weight of the materials) on the opposite side, each patient serving as his or her own control. The graft material was placed at the level of the facet joints and the intertransverse processes. Patients were randomized to receive the extender on either the right or the left side. This article is a preliminary report on patients who have undergone this procedure.

Adult↗