PubMed Health⌕ Search

Biomedical subjects

Robert H Hawes

Publications and source records attributed to Robert H Hawes.

At least 19 recordsLinked to original sources

The MCP-1 -2518 A/G polymorphism is not a susceptibility factor for chronic pancreatitis.

BACKGROUND AND AIMS: Chronic pancreatitis (CP) is an inflammatory process initiated by recurrent acute pancreatitis and characterized by progressive parenchyma destruction and fibrosis. Genetic factors influence susceptibility and modify progression. The monocyte chemotactic protein-1 (MCP-1) -2518 G allele, which modifies the severity of acute pancreatitis, was investigated as a susceptibility factor for CP. METHODS: A genetic association study was performed on 177 CP patients and 116 healthy controls from the NAPS2 Study. The MCP-1 A/G genotype was determined by RFLP and confirmed by DNA sequencing. RESULTS: Compared to the control group the MCP-1 -2518 genotypes were similar: A/A (57% vs. 50%), A/G (34.5% vs. 40%) and G/G (8.5% vs. 10%). These allele frequencies were not statistically different (p = 0.267). CONCLUSIONS: Although the pro-inflammatory chemokine MCP-1 -2518 G allele is a severity factor for AP, it does not significantly alter susceptibility to CP.

Adolescent↗

The endoscopic transilluminator: an endoscopic device for identification of the proximal jejunum for transgastric endoscopic gastrojejunostomy.

BACKGROUND: Localization of the proximal jejunum is important for creation of gastrojejunal anastomosis to palliate gastric outlet obstruction or for treatment of obesity with gastric bypass. OBJECTIVE: To facilitate identification of the proximal jejunum during transgastric endoscopic gastrojejunostomy with the use of an endoscopic transilluminator (ET). DESIGN AND SETTING: Acute experiments in a live porcine model. INTERVENTIONS: The ET is a 3500-mm long, 6F radio-opaque tube with a fiberoptic core that lights up at its distal end. When situated in the intestinal lumen, it transilluminates the bowel wall. With the animal under general anesthesia with endotracheal intubation, a colonoscope was advanced to the proximal jejunum. A plastic tube (3500-mm long, 3.5 mm in diameter) was passed through the biopsy channel and placed into the small bowel. The colonoscope was withdrawn, leaving the tube in place. The ET was introduced into the jejunum through the tube. A gastric wall incision was made and the endoscope was advanced to the peritoneal cavity. The transilluminated loop of the proximal jejunum was identified and gastrojejunal anastomosis was made by use of a previously reported endoscopic technique. MAIN OUTCOME MEASUREMENTS: Identification of the proximal jejunum. RESULTS: Eleven pigs (average weight 55 kg) had ET placement. In all of the pigs, placement of the ET was performed easily to the proximal small bowel, and the proximal jejunum was successfully localized by either direct visualization of the transilluminated loop only or with the aid of fluoroscopy. The tip of the ET was usually located about 50 to 70 cm distal to the ligament of Treitz. There were no complications related to the use of ET. LIMITATIONS: The device has not yet been evaluated in humans. CONCLUSIONS: The ET is a safe instrument and can be used to identify the proximal jejunum to facilitate endoscopic gastrojejunostomy.

Animals↗

Immediate endoscopic closure of colon perforation by using a prototype endoscopic suturing device: feasibility and outcome in a porcine model (with video).

BACKGROUND: Perforation is an uncommon but potentially devastating complication of colonoscopy. Surgical closure is the standard of care. Immediate endoluminal closure of a perforation would avoid the morbidity and mortality associated with general anesthesia, laparotomy, and surgical repair. OBJECTIVES: To evaluate the feasibility and safety of full-thickness endoscopic closure of colonic perforations with a prototype endoscopic suturing device, the Eagle Claw, in a porcine model. DESIGN: Endoscopic animal experimental study of closure of colon perforation by using a porcine model. SUBJECTS: Ten pigs were included in the study. INTERVENTIONS: The Eagle Claw was used to close small perforations (1.5 to 2 cm) of the colon created by needle-knife with the animal under general anesthesia by using the endoluminal route. All animals received intravenous antibiotics and were allowed to eat after 24 hours. MAIN OUTCOME MEASUREMENTS: The animals were monitored daily for signs of sepsis and peritonitis. On day 7, they were euthanized. The peritoneal cavity was examined for fecal peritonitis, and the colon perforation site was checked for wound dehiscence and pericolic abscess formation. RESULTS: Endoscopic closure of the colon perforation was successful in 7 animals, and they recovered well without any sepsis or peritonitis. Necropsy did not reveal fecal peritonitis or pericolonic abscess formation at the site of perforation, and the perforation healed well. Closure was successful in 1 animal, but necropsy revealed dehiscence of the colon perforation site. Endoscopic closure was unsuccessful in 2 animals, and these were euthanized immediately. CONCLUSIONS: Closure of acute perforation of the colon is feasible with the Eagle Claw endoscopic suturing device in a porcine model.

Animals↗

Pilot study of the porcine uterine horn as an in vivo appendicitis model for development of endoscopic transgastric appendectomy.

BACKGROUND: Iatrogenic inflammation of the porcine uterine horn may serve as an in vivo appendicitis model for the development of endoscopic transgastric appendectomy. OBJECTIVE: Five female pigs. STUDY DESIGN: Animal study. SETTINGS: General anesthesia. MAIN OUTCOME MEASUREMENTS: Anatomical appearance and technical feasibility. INTERVENTIONS: Three pigs were used to identify an injectable material that would inflame the uterine horn, and 2 pigs were used for a pilot appendectomy. Three types of materials were individually injected into the bilateral uterine horns, and the ideal material to inflame the uterine horn was injected into the right uterine horn for the last 2 pigs. After 24 hours, the injected uterine horns of the first 3 pigs were assessed and a pilot appendectomy was performed in the last 2 pigs. RESULTS: Ethanolamine oleate (EO) injected uterine horns demonstrated similarities to the inflamed human appendix. Simulations of the appendectomy were successfully performed by using the EO model. LIMITATIONS: Suboptimal existing tools. CONCLUSIONS: This preliminary study demonstrated the technical feasibility to create a model for acute appendicitis by using the porcine uterine horn and transgastric appendectomy.

Animals↗

Best of DDW 2006.

Highlights from the 2006 Digestive Disease Week May 20-25, 2006, Los Angeles, CA. In this meeting review, many of our editorial board members report on Digestive Disease Week 2006. They highlight the most noteworthy presentations in their respective areas of expertise, including the latest treatments, technologies, and diagnostic advances in ulcerative colitis, Crohn's disease, Helicobacter pylori infection, gastroesophageal reflux disease, irritable bowel syndrome, colorectal cancer, pancreatic and biliary disease, and liver disease.

Digestive System Diseases↗

The expanding role of endoscopic ultrasound in pancreatic disease.

Since endoscopic ultrasound (EUS) was first developed in the 1980s, this technology has emerged as the principal modality for imaging the pancreas. When compared with other imaging techniques, EUS can more accurately image solid lesions of the pancreas and determine vascular involvement that might preclude surgery. Furthermore, EUS-guided fine needle aspiration allows safe and accurate sampling and histological diagnosis of these lesions. EUS also plays a large role in the evaluation of cystic lesions of the pancreas. EUS cyst morphology, as well as fluid analysis obtained by fine needle aspiration, can often be used to diagnose the etiology of these lesions, helping the clinician to more accurately assess the presence or potential for malignancy. EUS can also predict the probability of the presence of chronic pancreatitis, primarily on the basis of histological correlates. The focus of this review is to discuss the role of EUS in these and other commonly encountered pancreatic diseases.

Diagnosis, Differential↗

Principles of endosonography and imaging.

Accurate interpretation of ultrasound images requires knowledge of the principles of ultrasound and how it interacts with tissue. This article outlines the important principles that every endosonographer should know and provides clinical implications to make the material relevant to endosonographers.

Endosonography↗

Post-sphincterotomy bleeding after the introduction of microprocessor-controlled electrosurgery: does the new technology make the difference?

BACKGROUND: Bleeding as a complication of endoscopic sphincterotomy is influenced by several factors. The objective of this study was to compare rates of bleeding after sphincterotomy performed with two different electrosurgical current generators (Valleylab SSE2L and ERBE ICC200). METHODS: A total of 6179 consecutive reports of ERCP were analyzed to compare the frequency of endoscopically and clinically evident bleeding after sphincterotomy when using the Valleylab SSE2L generator (from February 1994 to November 1997) and the ERBE ICC200 generator (from December 1997 to September 2000). Relevant risk factors were assessed by univariate analysis and significant predictors were included in a multiple logistic regression model. RESULTS: A total of 2711 sphincterotomies were performed in 2309 patients (1749 biliary, 962 pancreatic). Endoscopically observed bleeding occurred in 68 patients (5.5%) in the ValleyLab group and 13 (1.2%) in the ERBE group. The ValleyLab generator was independently associated with an increase in endoscopically observed bleeding (OR 4.02: 95% CI[2.13, 7.61], p <0.001). There was no significant difference in clinically evident bleeding between the two groups. CONCLUSIONS: Use of the microprocessor-controlled ERBE electrosurgical generator for endoscopic sphincterotomy was associated with a significantly lower frequency of endoscopically observed bleeding but not clinically evident bleeding.

Adult↗

Peroral transgastric endoscopic ligation of fallopian tubes with long-term survival in a porcine model.

BACKGROUND: We have previously reported the feasibility and safety of the peroral transgastric endoscopic approach for diagnostic peritoneoscopy, liver biopsy, and gastrojejunostomy with long-term survival in a porcine model. This approach eliminates incisions of the abdominal wall, providing a less invasive alternative to diagnostic and therapeutic laparoscopy. We now report successful performance of peroral endoscopic transgastric ligation of Fallopian tubes with long-term survival in a porcine model. METHODS: Six female 50-kg pigs had general anesthesia and irrigation of the stomach with an antibiotic solution. Gastric puncture was performed with needleknife electrocautery followed by balloon dilatation of the tract with 20-mm TTS dilating balloon (Microvasive). A standard upper endoscope that underwent high-level disinfection and gas sterilzation was advanced into the peritoneal cavity through a sterile overtube. Both Fallopian tubes were identified and one was ligated using Olympus Endoloops. The other patent tube served as a control. Tubal patency was evaluated by hysterosalpingogram before and after ligation. After a follow-up period of 2-3 weeks, the pigs were sacrificed for postmortem examination. RESULTS: The Fallopian tubes were easily accessed, identified and ligated in all 6 pigs. In each pig, fluoroscopy confirmed complete obstruction of the ligated tube with preserved patency of the other tube. All pigs survived well and ate heartily without any ill-effects. Postmortem examination did not reveal any peritonitis or intra-abdominal adhesions. The Endoloops were in place with complete obstruction of the ligated tubes and patency of the controls. Histopathologic examination of the tubes showed chronic inflammatory infiltrates without abscesses. CONCLUSIONS: The peroral endoscopic transgastric approach to ligation of the Fallopian tubes with long-term survival is technically feasible and safe in a porcine model. The endoscopic transgastric approach to the peritoneal cavity has potential for a wide array of diagnostic and therapeutic procedures.

Animals↗

Predictors of outcome in pancreatic duct disruption managed by endoscopic transpapillary stent placement.

BACKGROUND: The aim of this study was to identify predictors of outcome for pancreatic duct (PD) disruption managed by endoscopic transpapillary stent insertion. METHODS: An endoscopy database was used to identify patients with PD disruption, defined as extravasation of contrast from the PD during ERCP. Data collected included demographic information, the results of imaging studies, management before endoscopic intervention, and outcomes after stent placement. Stents typically were exchanged at intervals of 6 to 8 weeks. Success was defined as clinical and pancreatographic resolution of the PD disruption. RESULTS: Ninety-seven consecutive patients (34 women, 63 men; mean age, 53.7 [12.3] years) with PD disruption seen from 1995 to 2002 were identified. Causes of the disruption were the following: chronic pancreatitis (47), acute pancreatitis (44), operative injury (4), and trauma (2). Transpapillary PD stent insertion was technically successful in 92 (95%) patients; two underwent a combined cystenterostomy. The median duration of stent placement was 58 days (range 4-640 days). The outcome of stent insertion was successful in 52 patients (55%), unsuccessful in 32 (36%), and indeterminate in 8 (9%). On univariate analysis, a partially disrupted PD (p < 0.001), a disruption in the body of the pancreas (p = 0.04), a stent positioned to bridge the disruption (p < 0.001), and a longer duration of stent therapy (p = 0.03) were associated with a successful outcome. On multivariable logistic regression, only a partially disrupted duct and a stent bridging the disruption correlated with a successful outcome. Complications occurred in 6 patients. CONCLUSIONS: Successful resolution of PD disruption by transpapillary stent insertion depends on the type of disruption and the ability to bridge the disrupted duct with a stent.

Adult↗

Endoscopic suturing without extracorporeal knots: a laboratory study.

BACKGROUND: To eliminate cumbersome extracorporeal knotting, we designed a new endoscopic suturing device, the Eagle Claw V. The efficacy of the new device was tested on the Erlangen model and was compared with the initial extracorporeal knotting version (Eagle Claw II). METHODS: Segments of porcine splenic arteries were placed on the mucosal surface of the anterior wall of a pig stomach. The two ends of the artery were brought out through the gastric wall and were connected to a two-channel manometer. The Eagle Claw V has a curved needle with a detachable tip. After puncturing the tissue, the needle tip was engaged into a catching cartridge, where the suture had been embedded in a tightening mechanism. The suture could be tightened by simply pulling the end. The Eagle Claw V was used to plicate the splenic arteries mounted on the stomach. Suturing was considered secure if the suture could withstand endoluminal pressure greater than 200 mm Hg that lasted at least 10 seconds. RESULTS: Eleven of 15 stitches (73.3%) gained secure plication of the vessels. The suturing time (mean +/- standard deviation 2.93 +/- 0.80 minutes) was significantly faster than that of the Eagle Claw II (9.38 +/- 1.51 minutes). The device consistently achieved penetration of the muscular layer, and 4 of 15 sutures included the serosa. The 4 failures were because of suture breakage in two, thread entanglement in one, and cartridge dislodgement in one. CONCLUSIONS: The present prototype represents significant improvements in the ease of operation and the security of the suture, bringing the technique closer to clinical use for a variety of applications.

Animals↗

Eagle Claw II: A novel endosuture device that uses a curved needle for major arterial bleeding: a bench study.

BACKGROUND: Control of bleeding from major arteries in the upper-GI tract remains difficult with currently available endoscopic devices. We designed an endosuture device that uses a curved needle and extracorporeal knotting, and assessed the device in stopping arterial bleeding in a bench model. METHODS: Harvested porcine splenic arteries (2-mm diameter) were tunneled submucosally in pig stomach with the open end protruding into an artificially created mucosal defect. The outer end of the vessel was connected to a pulsatile pump, and red ink was infused at a pressure of about 100 mm Hg. The stomach was installed on an Erlangen endo-training model. The suturing device (Eagle Claw II), mounted outside an endoscope, has an eyed, curved needle that carries a 3-0 nylon thread. After puncture, the thread was retrieved by using a hook. Three-throw square knots were tied at the thread extracorporeally and were pushed into place by using a knotting cap. The criteria of successful plication was defined as hemostasis after knotting, no leakage at pressures of >200 mm Hg, and the vessel was completely encircled by the suture. RESULTS: A total of 25 sutures were made with the mean time of 9.38 minutes (standard deviation 1.51). Control of the bleeding was obtained with 17 sutures (68%). The causes for failure were the following: a suture was too shallow (4), a loose knot (2), incorrect suture position (1), and stomach-wall edema (1). CONCLUSIONS: Control of bleeding from large arteries by using endoscopic suturing is possible. Continued refinements of the device are required.

Animals↗

Endoscopic gastrojejunostomy with survival in a porcine model.

BACKGROUND: We have previously reported the feasibility and the safety of an endoscopic transgastric approach to the peritoneal cavity in a porcine model. We now report successful performance of endoscopic gastrojejunostomy with survival. METHODS: All procedures were performed on 50-kg pigs, with the pigs under general anesthesia, in aseptic conditions with sterilized endoscopes and accessories. The stomach was irrigated with antibiotic solution, and a gastric incision was performed with a needle-knife and a sphincterotome. A standard upper endoscope was advanced through a sterile overtube into the peritoneal cavity. A loop of jejunum was identified, was retracted into the stomach, and was secured with sutures while using a prototype endoscopic suturing device. An incision was made into the jejunal loop with a needle-knife, and the filet-opened ends of the jejunal wall were secured to the gastric wall with a second line of sutures, completing the gastrojejunostomy. OBSERVATIONS: Two pigs survived for 2 weeks. Endoscopy and a radiographic contrast study performed after gastrojejunostomy revealed a patent anastomosis with normal-appearing gastric and jejunal mucosa. Postmortem examination demonstrated a well-healed anastomosis without infection or adhesions. CONCLUSIONS: The endoscopic transgastric approach to create a gastrojejunostomy is technically feasible and can be performed, with survival, in a porcine model.

Animals↗

Endoscopic ultrasound in lung cancer patients with a normal mediastinum on computed tomography.

BACKGROUND: Computed tomography (CT) is the most common method of staging lung cancer. We have previously shown endoscopic ultrasound guided fine-needle aspiration (EUS-FNA) to be highly accurate in staging patients with nonsmall cell lung cancer (NSCLC) who have enlarged mediastinal lymph nodes on CT scan. In this study we report the accuracy and yield of EUS-FNA in staging patients without enlarged mediastinal lymph nodes by CT. METHODS: Patients with NSCLC and CT scan showing no enlarged mediastinal lymph nodes (> 1 cm for all nodes except > 1.2 cm for subcarinal) in the mediastinum underwent EUS. Fine needle aspiration was performed on at least one lymph node, if present, in the upper mediastinum, aortopulmonary window, subcarinal, and periesophagus regions. Each specimen was evaluated with on-site cytopathology and confirmed with complete cytopathologic examination. RESULTS: Sixty-nine patients without enlarged mediastinal lymph nodes were evaluated. Endoscopic ultrasound detected malignant mediastinal lymph nodes in 14 of 69 patients as well as other advanced (American Joint Committee on Cancer [AJCC] stage III/IV) in 3 others (1 left adrenal, and 2 with mediastinal invasion of tumor) for a total of 17 of 69 (25%, 95% confidence interval: 16% to 34%) patients. Eleven additional patients were found to have advanced disease by bronchoscopy (2), mediastinoscopy (2), and thoracotomy with mediastinal lymph node dissection (7). The sensitivity of EUS for advanced mediastinal disease was 61% (49% to 75%), and the specificity was 98% (95% to 100%). CONCLUSIONS: Endoscopic ultrasound guided fine needle aspiration can detect advanced mediastinal disease and avoid unnecessary surgical exploration in almost one of four patients who have no evidence of mediastinal disease on CT scan. In addition to previously reported results in patients with enlarged lymph nodes on CT, these data suggest that all potentially operable patients with nonmetastatic NSCLC may benefit from EUS staging.

Adenocarcinoma↗