PubMed Health⌕ Search

Biomedical subjects

Robert Ivkov

Publications and source records attributed to Robert Ivkov.

4 recordsLinked to original sources

The magnitude and time-dependence of the apoptotic response of normal and malignant cells subjected to ionizing radiation versus hyperthermia.

PURPOSE: The purpose of the study was to examine the optimal time of exposure and dose of heat and ionizing radiation that results in the killing of human cancer cells in vitro via apoptosis vs. necrosis. MATERIALS AND METHODS: Human mammary carcinoma, colorectal carcinoma and normal bovine capillary endothelial (BCE) cell lines were subjected to 20 Gy ionizing radiation and 6, 12, 24, and 72 h later assessed for apoptosis using detection of apoptotic bodies and caspase assays. Necrosis was detected by loss of cells from the surface and lactate dehydrogenase (LDH) release. The colorectal carcinoma cells were subjected to hyperthermia using temperatures ranging from 39 - 44 degrees C for 5, 15 or 45 min. exposures and at varying times post-treatment, apoptosis and necrosis were measured. RESULTS: In response to ionizing radiation, none of the cells underwent necrosis and some cell types apoptosed 24 and 72 h posttreatment. The colorectal cancer cells exhibited a steady increase of apoptosis at 6, 12, and 24 h. When these cells were exposed to 40 degrees C for 5 min, caspases increased within 6 h and a significant fraction (50%) of cells apoptosed. If the time of exposure to 40 degrees C was increased to 15 or 45 min, 80% and 100% of the dying cells apoptosed, respectively. A temperature of 39 degrees C did not cause cell death even after 45 min exposures. If heat was elevated to 42 or 44 degrees C, increased necrosis was observed with a corresponding decrease in apoptosis. CONCLUSIONS: These studies reveal time and temperature dependent in vitro cell responses to ionizing radiation and water-bath hyperthermia.

Animals↗

The polymerization of actin: structural changes from small-angle neutron scattering.

We present a new analysis of small-angle neutron-scattering data from rabbit muscle actin in the course of the polymerization from G-actin to F-actin as a function of temperature. The data, from Ivkov et al. [J. Chem. Phys. 108, 5599 (1998)], were taken in D2O buffer with Ca2+ as the divalent cation on the G-actin in the presence of ATP and with KCl as the initiating salt. The new analysis of the data using modeling and the method of generalized indirect fourier transform (O. Glatter, GIFT, University of Graz, Austria, http://physchem.kfunigraz.ac.at/sm/) provide shapes and dimensions of the G-actin monomer and of the growing actin oligomer in solution as a function of temperature and salt concentration. This analysis indicates that the G-actin monomer, under the conditions given above, is a sphere 50-54 A in diameter as opposed to the oblate ellipsoid seen by x-ray crystallography. The F-actin dimensions are consistent with x-ray crystal structure determinations.

Actins↗

Application of high amplitude alternating magnetic fields for heat induction of nanoparticles localized in cancer.

OBJECTIVE: Magnetic nanoparticles conjugated to a monoclonal antibody can be i.v. injected to target cancer tissue and will rapidly heat when activated by an external alternating magnetic field (AMF). The result is necrosis of the microenvironment provided the concentration of particles and AMF amplitude are sufficient. High-amplitude AMF causes nonspecific heating in tissues through induced eddy currents, which must be minimized. In this study, application of high-amplitude, confined, pulsed AMF to a mouse model is explored with the goal to provide data for a concomitant efficacy study of heating i.v. injected magnetic nanoparticles. METHODS: Thirty-seven female BALB/c athymic nude mice (5-8 weeks) were exposed to an AMF with frequency of 153 kHz, and amplitude (400-1,300 Oe), duration (1-20 minutes), duty (15-100%), and pulse ON time (2-1,200 seconds). Mice were placed in a water-cooled four-turn helical induction coil. Two additional mice, used as controls, were placed in the coil but received no AMF exposure. Tissue and core temperatures as the response were measured in situ and recorded at 1-second intervals. RESULTS: No adverse effects were observed for AMF amplitudes of < or = 700 Oe, even at continuous power application (100% duty) for up to 20 minutes. Mice exposed to AMF amplitudes in excess of 950 Oe experienced morbidity and injury when the duty exceeded 50%. CONCLUSION: High-amplitude AMF (up to 1,300 Oe) was well tolerated provided the duty was adjusted to dissipate heat. Results presented suggest that further tissue temperature regulation can be achieved with suitable variations of pulse width for a given amplitude and duty combination. These results suggest that it is possible to apply high-amplitude AMF (> 500 Oe) with pulsing for a time sufficient to treat cancer tissue in which magnetic nanoparticles have been embedded.

Animals↗

Development of tumor targeting bioprobes ((111)In-chimeric L6 monoclonal antibody nanoparticles) for alternating magnetic field cancer therapy.

OBJECTIVES: (111)In-chimeric L6 (ChL6) monoclonal antibody (mAb)-linked iron oxide nanoparticle (bioprobes) pharmacokinetics, tumor uptake, and the therapeutic effect of inductively heating these bioprobes by externally applied alternating magnetic field (AMF) were studied in athymic mice bearing human breast cancer HBT 3477 xenografts. Tumor cell radioimmunotargeting of the bioprobes and therapeutic and toxic responses were determined. METHODS: Using 1-ethyl-3-(3-dimethylaminopropyl)-carbodiimide HCl, (111)In-7,10-tetra-azacyclododecane-N, N',N'',N'''-tetraacetic acid-ChL6 was conjugated to the carboxylated polyethylene glycol on dextran-coated iron oxide 20 nm particles, one to two mAbs per nanoparticle. After magnetic purification and sterile filtration, pharmacokinetics, histopathology, and AMF/bioprobe therapy were done using (111)In-ChL6 bioprobe doses (20 ng/2.2 mg ChL6/ bioprobe), i.v. with 50 microg ChL6 in athymic mice bearing HBT 3477; a 153 kHz AMF was given 72 hours postinjection for therapy with amplitudes of 1,300, 1,000, or 700 Oe. Weights, blood counts, and tumor size were monitored and compared with control mice receiving nothing, or AMF or bioprobes alone. RESULTS: (111)In-ChL6 bioprobe binding in vitro to HBT 3477 cells was 50% to 70% of that of (111)In-ChL6. At 48 hours, tumor, lung, kidney, and marrow uptakes of the (111)In-ChL6 bioprobes were not different from that observed in prior studies of (111)In-ChL6. Significant therapeutic responses from AMF/bioprobe therapy were shown with up to eight times longer mean time to quintuple tumor volume with therapy compared with no treatment (P = 0.0013). Toxicity was only seen in the 1,300 Oe AMF cohort, with 4 of 12 immediate deaths and skin erythema. Electron micrographs showed bioprobes on the surfaces of the HBT 3477 cells of excised tumors and tumor necrosis 24 hours after AMF/bioprobe therapy. CONCLUSION: This study shows that mAb-conjugated nanoparticles (bioprobes), when given i.v., escape into the extravascular space and bind to cancer cell membrane antigen, so that bioprobes can be used in concert with externally applied AMF to deliver thermoablative cancer therapy.

Animals↗