PubMed Health⌕ Search

Biomedical subjects

Robert J Greenberg

Publications and source records attributed to Robert J Greenberg.

5 recordsLinked to original sources

Microsensors and microbiosensors for retinal implants.

This paper concentrates on recent developments in microsensors and microbiosensors for the possible applications in visual prostheses, especially retinal prosthetic devices. A brief introduction on the developments of visual prosthesis will be presented. The importance for in-vivo pH measurements as well as the need for an implantable pH sensor will be demonstrated. Electrochemical biosensors developed for sensitive measurements of glucose and L-glutamate, a known neurotransmitter in the retina and brain will be reviewed. Novel electrode materials such as chemically modified thin-film diamond in applications for implantable biosensors will be shown. The challenges in the development of chronic implantable sensor systems, especially using MEMS technology for medical implants, will be discussed.

Animals↗

Perceptual thresholds and electrode impedance in three retinal prosthesis subjects.

Three test subjects blind from retinitis pigmentosa were implanted with retinal prostheses as part of a FDA-approved clinical trial. The implant consisted of an extraocular unit that contained electronics for wireless data, power, and generation of stimulus current, and an intraocular unit that consisted of 16 platinum stimulating electrodes arranged in a 4 x 4 pattern within a silicone rubber substrate. The array was held to the retina by a small tack. The stimulator was connected to the array by a multiwire cable and was controlled by a computer based external system that allowed precise control over each electrode. Perception thresholds and electrode impedance were obtained on each electrode from the subjects over several months of testing. The electrode distance from the retina was determined from optical coherence tomography imaging of the array and retina. Across all subjects, average thresholds ranged from 24-702 microA (1-ms pulse). The data show that proximity to the retina played a role in determining the threshold and impedance, but only for electrodes that were greater than 0.5 mm from the retina.

Blindness↗

Advances in the development of visual prostheses.

Visual prostheses are based on neuronal electrical stimulation at different locations along the visual pathway (ie, cortical, optic nerve, epiretinal, subretinal). In terms of retinal prostheses, advances in microtechnology have allowed for the development of sophisticated, high-density integrated circuit devices that may be implanted either in the subretinal or epiretinal space. Analogous to the cochlear implants for some forms of deafness, these devices could restore useful vision by converting visual information into patterns of electrical stimulation that would excite the remaining spared inner retinal neurons in patients with diseases such as retinitis pigmentosa and age-related macular degeneration. The different types of implants and recent results are discussed, but special emphasis is given to retinal implants.

Electric Stimulation↗

Retinal prosthesis for the blind.

Most of current concepts for a visual prosthesis are based on neuronal electrical stimulation at different locations along the visual pathways within the central nervous system. The different designs of visual prostheses are named according to their locations (i.e., cortical, optic nerve, subretinal, and epiretinal). Visual loss caused by outer retinal degeneration in diseases such as retinitis pigmentosa or age-related macular degeneration can be reversed by electrical stimulation of the retina or the optic nerve (retinal or optic nerve prostheses, respectively). On the other hand, visual loss caused by inner or whole thickness retinal diseases, eye loss, optic nerve diseases (tumors, ischemia, inflammatory processes etc.), or diseases of the central nervous system (not including diseases of the primary and secondary visual cortices) can be reversed by a cortical visual prosthesis. The intent of this article is to provide an overview of current and future concepts of retinal and optic nerve prostheses. This article will begin with general considerations that are related to all or most of visual prostheses and then concentrate on the retinal and optic nerve designs. The authors believe that the field has grown beyond the scope of a single article so cortical prostheses will be described only because of their direct effect on the concept and technical development of the other prostheses, and this will be done in a more general and historic perspective.

Blindness↗

Heat effects on the retina.

BACKGROUND AND OBJECTIVE: To study the heat and power dissipation effect of anintraocular electronic heater on the retina. The determination of thermal parameters that are nonharmful to the retina will aid in the development of an implantable intraocular electronic retinal prosthesis. MATERIALS AND METHODS: In dogs, five different retinal areas were touched with a custom intraocular heater probe (1.4 x 1.4 x 1.0 mm) for 1 second while the heater dissipated 0 (control), 10, 20, 50, or 100 mW. In a second protocol, the heater was mechanically held in the vitreous cavity while dissipating 500 mW for 2 hours while monitoring intraocular temperature. The animals were observed for 4 weeks with serial fundus photography and electroretinography. The procedure was then repeated in the fellow eye. The dogs were killed and both eyes were enucleated and submitted for histology. RESULTS: In experiments using protocol 1, heater settings of 50 mW or higher caused an immediate visible whitening of the retinal tissue. Histologically, this damage was evident only if the eyeswere immediately enucleated. Permanent damage was caused by heater settings of 100 mW or higher. Under protocol 2, no ophthalmologic, electroretinography, or histologic differences were noted between the groups. Temperature increases of 5 degrees C in the vitreous and 2 degrees C near the retina were noted. CONCLUSIONS: The liquid environment of the eye acts as a heat sink that is capable of dissipating a significant amount of power. An electronic chip positioned away from the retina can run at considerably higher powers than a chip positioned on the retinal surface.

Animals↗