Robert J Noll

Publications and source records attributed to Robert J Noll.

7 recordsLinked to original sources

Resonant ac dipolar excitation for ion motion control in the Orbitrap mass analyzer.

A dipolar ac signal applied to the split outer electrode of an Orbitrap mass spectrometer at the axial resonance frequency causes excitation of ion axial motion and either eventual ion ejection from the trap, if applied in phase with ion motion, or de-excitation, if applied 180 degrees out of phase. Both de-excitation and excitation may be achieved mass-selectively. The extent of ion axial de-excitation depends on the ac amplitude and on the number of cycles applied; sufficient de-excitation can be accomplished such that the ion signal cannot be observed above baseline noise. After de-excitation, the ions remain trapped and in rapid orbital (but not axial) motion, which allows them to be re-excited coherently by application of a second ac waveform allowing the signal again to be observed. Both broad-band and narrow-band waveforms have been used to de-excite and to re-excite ion motion. Using narrow-band waveforms, selective de-excitation and re-excitation can be performed with unit mass selection, leaving an adjacent 13C isotopic peak unaffected. The origin and potential applications of these new capabilities is delineated.

Journal Article↗

Direct monitoring of toxic compounds in air using a portable mass spectrometer.

A portable tandem mass spectrometer, capable of performing atmospheric pressure chemical ionization (APCI) using a direct atmospheric inlet, is applied to the real-time monitoring of toxic compounds in air. Analytes of interest include dimethyl methylphosphonate, arsine, benzene, toluene, pyridine and vinyl acetate. The detection, identification and quantification of organic and inorganic compounds in air is demonstrated using short analysis times (<5 seconds) with detection limits in the low ppb (v/v) levels and linear dynamic ranges of several orders of magnitude. Highly specific detection and identification is achieved, even when the analyte is a trace component in a complex mixture including such interferents as fuels, lubricants, and cleaners. The effects of environmental conditions, including temperature and humidity, are delineated. Receiver operating characteristic (ROC) curves are presented to show the trade-off between false positive and false negative detection rates. Tandem mass spectrometry based both on collision-induced dissociation and on selective atmospheric pressure ion/molecule reactions is also used to increase selectivity and sensitivity.

Air Pollutants↗

Analysis of gaseous toxic industrial compounds and chemical warfare agent simulants by atmospheric pressure ionization mass spectrometry.

The suitability of atmospheric pressure chemical ionization mass spectrometry as sensing instrumentation for the real-time monitoring of low levels of toxic compounds is assessed, especially with respect to public safety applications. Gaseous samples of nine toxic industrial compounds, NH3, H2S, Cl2, CS2, SO2, C2H4O, HBr, C6H6 and AsH3, and two chemical warfare agent simulants, dimethyl methylphosphonate (DMMP) and methyl salicylate (MeS), were studied. API-MS proves highly suited to this application, with speedy analysis times (<30 seconds), high sensitivity, high selectivity towards analytes, good precision, dynamic range and accuracy. Tandem MS methods were implemented in selected cases for improved selectivity, sensitivity, and limits of detection. Limits of detection in the parts-per-billion and parts-per-trillion range were achieved for this set of analytes. In all cases detection limits were well below the compounds' permissible exposure limits (PELs), even in the presence of added complex mixtures of alkanes. Linear responses, up to several orders of magnitude, were obtained over the concentration ranges studied (sub-ppb to ppm), with relative standard deviations less than 3%, regardless of the presence of alkane interferents. Receiver operating characteristic (ROC) curves are presented to show the performance trade-off between sensitivity, probability of correct detection, and false positive rate. A dynamic sample preparation system for the production of gas phase analyte concentrations ranging from 100 pptr to 100 ppm and capable of admixing gaseous matrix compounds and control of relative humidity and temperature is also described.

Air Pollutants↗

Desorption electrospray ionization using an Orbitrap mass spectrometer: Exact mass measurements on drugs and peptides.

Desorption electrospray ionization (DESI) is implemented on an Orbitrap mass spectrometer. The ion source is described and applications which utilize the high-resolution capabilities of the Orbitrap are emphasized, including the characterization of peptides and active ingredients in pharmaceutical tablets. Measurements are made in less than 1 s at a resolution of 60,000. The implications of the data for the mechanisms of DESI are discussed.

Bradykinin↗

Improved detection of low vapor pressure compounds in air by serial combination of single-sided membrane introduction with fiber introduction mass spectrometry (SS-MIMS-FIMS).

The use of two methods in tandem, single-sided membrane introduction mass spectrometry (SS-MIMS) and fiber introduction mass spectrometry (FIMS), is presented as a technique for field analysis. The combined SS-MIMS-FIMS technique was employed in both a modified commercial mass spectrometer and a miniature mass spectrometer for the selective preconcentration of the explosive simulant o-nitrotoluene (ONT) and the chemical warfare agent simulant, methyl salicylate (MeS), in air. A home-built FIMS inlet was fabricated to allow introduction of the solid-phase microextraction (SPME) fiber into the mass spectrometer chamber and subsequent desorption of the trapped compounds using resistive heating. The SS-MIMS preconcentration system was also home-built from commercial vacuum parts. Optimization experiments were done separately for each preconcentration system to achieve the best extraction conditions prior to use of the two techniques in combination. Improved limits of detection, in the low ppb range, were observed for the combination compared to FIMS alone, using several SS-MIMS preconcentration cycles. The SS-MIMS-FIMS response for both instruments was found to be linear over the range 50 to 800 ppb. Other parameters studied were absorption time profiles, effects of sample flow rate, desorption temperature, fiber background, memory effects, and membrane fatigue. This simple, sensitive, accurate, robust, selective, and rapid sample preconcentration and introduction technique shows promise for field analysis of low vapor pressure compounds, where analyte concentrations will be extremely low and the compounds are difficult to extract from a matrix like air.

Air Pollutants↗

The Orbitrap: a new mass spectrometer.

Research areas such as proteomics and metabolomics are driving the demand for mass spectrometers that have high performance but modest power requirements, size, and cost. This paper describes such an instrument, the Orbitrap, based on a new type of mass analyzer invented by Makarov. The Orbitrap operates by radially trapping ions about a central spindle electrode. An outer barrel-like electrode is coaxial with the inner spindlelike electrode and mass/charge values are measured from the frequency of harmonic ion oscillations, along the axis of the electric field, undergone by the orbitally trapped ions. This axial frequency is independent of the energy and spatial spread of the ions. Ion frequencies are measured non-destructively by acquisition of time-domain image current transients, with subsequent fast Fourier transforms (FFTs) being used to obtain the mass spectra. In addition to describing the Orbitrap mass analyzer, this paper also describes a complete Orbitrap-based mass spectrometer, equipped with an electrospray ionization source (ESI). Ions are transferred from the ESI source through three stages of differential pumping using RF guide quadrupoles. The third quadrupole, pressurized to less than 10(-3) Torr with collision gas, acts as an ion accumulator; ion/neutral collisions slow the ions and cause them to pool in an axial potential well at the end of the quadrupole. Ion bunches are injected from this pool into the Orbitrap analyzer for mass analysis. The ion injection process is described in a simplified way, including a description of electrodynamic squeezing, field compensation for the effects of the ion injection slit, and criteria for orbital stability. Features of the Orbitrap at its present stage of development include high mass resolution (up to 150,000), large space charge capacity, high mass accuracy (2-5 ppm), a mass/charge range of at least 6000, and dynamic range greater than 10(3). Applications based on electrospray ionization are described, including characterization of transition-metal complexes, oligosaccharides, peptides, and proteins. Use is also made of the high-resolution capabilities of the Orbitrap to confirm the presence of metaclusters of serine octamers in ESI mass spectra and to perform H/D exchange experiments on these ions in the storage quadrupole.

Alcohol Dehydrogenase↗

Analytical performance of a miniature cylindrical ion trap mass spectrometer.

The analytical performance of a fieldable cylindrical ion trap (CIT)-based miniature mass spectrometer is described. A detailed description of the instrument itself is to be found in the immediately preceding paper (Patterson, G. E.; Guymon, A. J.; Riter, L S.; Everly, M.; Griep-Raming, J.; Laughlin, B. C.; Ouyang, Z.; Cooks, R. G., Miniature Cylindrical Ion Trap Mass Spectrometer, Anal. Chem. 2002, 24, 6145-6153). Applications employing the MS/MS and MSn capabilities of the miniature instrument and analytical performance criteria are given here. The limit of detection for methyl salicylate, introduced as the pure vapor, is estimated as 1 pg. The resolution, R = m/delta m, where delta m, measured as full width at half-maximum, is estimated as 100. Monitoring of organic compounds in air is performed using a permeation membrane introduction device coupled to the mass spectrometer. Water monitoring is performed using an external membrane introduction mass spectrometry (MIMS) system, with acetophenone and toluene serving as model compounds. Data are given for chemical warfare agent simulants, methyl salicylate, and dimethyl methyl phosphonate (DMMP) in air. On-line detection of menthol vapor emitted from a cough drop is reported. Methyl salicylate in air gives a recognizable mass spectrum at 400 ppb in the ambient system, while use of a heated membrane brings the detection limit down to 10 ppb.

Journal Article↗