PubMed Health⌕ Search

Biomedical subjects

Robert J Schutte

Publications and source records attributed to Robert J Schutte.

2 recordsLinked to original sources

Protein array method for assessing in vitro biomaterial-induced cytokine expression.

This study demonstrates the feasibility of a cytokine-based in vitro test for biomaterials. The combination of monocyte culture and protein array technology tested in this study permitted the detection of subtle changes in cytokine expression following an exposure to titanium (Ti) particles. However, a broader range of materials and sample configurations must be examined before these promising results can be translated into a reliable and predictive in vitro biomaterials testing protocol. Modified glass slides were robotically printed with eight identical arrays consisting of capture antibodies against four mouse cytokines [IL-6, TNF-alpha, MIP-2, TGF-beta1] and two positive and two negative detection controls. RAW 264.7 mouse monocytes seeded into six-well plates at 10(5)cells/well were treated with either sterilized Ti particles (test biomaterial), or lipopolysaccharide (LPS; positive control), or untreated (negative control). Aliquots (80 microl) of culture medium collected at 1, 6, 24, 48, and 72 h were applied to the protein arrays for simultaneous sandwich fluoroimmunoassay, followed by imaging the fluorescent intensities on a conventional microarray scanner. LPS induced the release of all four cytokines between 1 and 6h treatment periods, whereas Ti induction of cytokines showed a gradual and subtle increase in cytokine expression for >24 h. Among the four cytokines assayed, TNF-alpha and MIP-2 were most prominently expressed, while IL-6 was slightly elevated and TGF-beta1 was undetected above background.

Animals↗

In vitro characterization of microdialysis sampling of macromolecules.

Experiments were performed to characterize the in vitro collection of macromolecules using microdialysis. Fluorescently labeled proteins and dextrans ranging from 3000 to 150 000 were sampled using a 10-mm, 100 000 molecular weight cutoff, polyethersulfone microdialysis probe. Published models describing microdialysis mass transport of small molecules were examined to determine their appropriateness for sampling of macromolecules. Collection efficiencies, reported as relative recoveries, for macromolecules from 3000 to 70 000 ranged from 5 to 44%. Collection efficiencies determined for microdialysis sampling of macromolecules follow the functionality of published models, although experimental mass transport resistances are to some extent smaller than predicted. Implications of the current study for in vivo microdialysis sampling of cytokines and growth factors are discussed.

Dextrans↗