In vitro assessment of image-guided otologic surgery: submillimeter accuracy within the region of the temporal bone.

OBJECTIVES: Application of image-guided surgery to otology has been limited by the need for submillimeter accuracy via a fiducial system that is easily usable (noninvasive and nonobstructive). METHODS: A dental bite-block was fitted with a rigid frame with 7 fiducial markers surrounding each external ear. The temporal bones of 3 cadaveric skulls were removed and replaced with surgical targets arranged in a bull's-eye pattern about the centroid of each temporal bone. The surgical targets were identified both within CT scans and in physical space using an infrared optical tracking system. The difference between positions in CT space versus physical space was calculated as target registration error. RESULTS: A total of 234 independent target registration errors were calculated. Mean +/- standard deviation = 0.73 mm +/- 0.25 mm. CONCLUSIONS: These findings show that image-guided otologic surgery with submillimeter accuracy is achievable with a minimally invasive fiducial frame. Significance In vivo validation of the system is ongoing. With such validation, this system may facilitate clinically applicable image-guided otologic surgery. EBM RATING: A.

Humans↗

Compensating for intraoperative soft-tissue deformations using incomplete surface data and finite elements.

Image-guided liver surgery requires the ability to identify and compensate for soft tissue deformation in the organ. The predeformed state is represented as a complete three-dimensional surface of the organ, while the intraoperative data is a range scan point cloud acquired from the exposed liver surface. The first step is to rigidly align the coordinate systems of the intraoperative and preoperative data. Most traditional rigid registration methods minimize an error metric over the entire data set. In this paper, a new deformation-identifying rigid registration (DIRR) is reported that identifies and aligns minimally deformed regions of the data using a modified closest point distance cost function. Once a rigid alignment has been established, deformation is accounted for using a linearly elastic finite element model (FEM) and implemented using an incremental framework to resolve geometric nonlinearities. Boundary conditions for the incremental formulation are generated from intraoperatively acquired range scan surfaces of the exposed liver surface. A series of phantom experiments is presented to assess the fidelity of the DIRR and the combined DIRR/FEM approaches separately. The DIRR approach identified deforming regions in 90% of cases under conditions of realistic surgical exposure. With respect to the DIRR/FEM algorithm, subsurface target errors were correctly located to within 4 mm in phantom experiments.

Algorithms↗

Dynamic, three-dimensional optical tracking of an ablative laser beam.

Surgical resection remains the treatment of choice for brain tumors with infiltrating margins but is currently limited by visual discrimination between normal and neoplastic marginal tissues during surgery. Imaging modalities such as computed tomography, magnetic resonance, positron emission tomography, and optical techniques can accurately localize tumor margins. We believe coupling the fine resolution of current imaging techniques with the precise cutting of midinfrared lasers through image-guided neurosurgery can greatly enhance tumor margin resection. This paper describes a feasibility study designed to optically track in three-dimensional space the articulated arm delivery of a noncontact ablative laser beam. To enable optical tracking of the laser beam focus, infrared-emitting diodes (IREDs) were attached to a handpiece machined for the distal end of the articulated arm of a surgical carbon dioxide laser. Crosstalk between the ablative laser beam and the tracking diodes was measured. The geometry of the adapted laser handpiece was characterized to track an externally attached passive tip and the laser beam focus. Target localization accuracies were assessed for both instrument points-of-interest and the sources of tracking errors were investigated. Stray infrared laser light did not affect optical tracking accuracy. The mean target registration errors while optically tracking the laser handpiece with a passive tip and the laser beam focus were 1.31+/-0.50 mm and 2.31+/-0.92 mm, respectively, and were equivalent to the errors tracking a 24-IRED pen probe from Northern Digital in a side-by-side comparison. The majority of error during ablation tracking derived from registration accuracy between physical space and the defined space of the ablation phantom and from an inability to freehand align the laser focus with the target in a consistent manner. While their magnitudes depend on spatial details of the tracking setup (e.g., number and distribution of fiducial points, working distance from the camera, etc.), these errors are inherent to any freehand laser surgery.

Brain Neoplasms↗

Development of a three-dimensional freehand endorectal ultrasound system for use in rectal cancer imaging.

The initial study reporting the accuracy of an optically tracked endorectal ultrasound (TERUS) probe for the purpose of improving the staging of rectal cancer is presented here. In this work we describe the need for a more accurate ERUS system and why the incorporation of image guidance makes this goal feasible. A rectal phantom was constructed with five targets placed in positions where tumors normally occur. The locations of these targets were found using two different imaging modalities, CT and ultrasound, and the target registration error (TRE) between these two image sets was calculated. The average TRE of 33 image captures of the five targets using TERUS was 2.1 mm. This is a promising outcome because the desired tumor margins for rectal cancer are on the order of centimeters. These preliminary results support the proof of concept for a TERUS system that should improve ultrasound imaging in rectal cancer.

Calibration↗

Submillimetric target-registration error using a novel, non-invasive fiducial system for image-guided otologic surgery.

OBJECTIVE: Otologic surgery is undertaken to treat ailments of the ear, including persistent infections, hearing loss, vertigo, and cancer. Typically performed on otherwise-healthy patients in outpatient facilities, the application of image-guided surgery (IGS) has been limited because accurate (<1 mm), non-invasive fiducial systems for otologic surgery have not been available. We now present such a fiducial system. METHODS: A dental bite-block was fitted with a custom-designed rigid frame with 7 fiducial markers surrounding each external ear. The bones containing the ear (i.e., the temporal bones) of 3 cadaveric skulls were removed and replaced with discs containing 13 surgical targets arranged in a cross-hair pattern about the centroid of each ear. The surgical targets (26/skull) and fiducial markers (14/skull) were identified both within CT scans using a published algorithm and in physical space using an infrared optical tracking system. Fiducial registration error (FRE), fiducial localization error (FLE), and target registration error (TRE) were calculated. RESULTS: For all trials, root mean square FRE = 0.66, FLE = 0.72, and TRE = 0.77 mm. The mean TRE for n = 234 independent targets was 0.73 with a standard deviation of 0.25 mm. CONCLUSIONS: Using a novel, non-invasive fiducial system (the EarMark), submillimetric accuracy was repeatably achieved. This system will facilitate image-guided otologic surgery.

Artifacts↗

Cortical surface registration for image-guided neurosurgery using laser-range scanning.

In this paper, a method of acquiring intraoperative data using a laser range scanner (LRS) is presented within the context of model-updated image-guided surgery. Registering textured point clouds generated by the LRS to tomographic data is explored using established point-based and surface techniques as well as a novel method that incorporates geometry and intensity information via mutual information (SurfaceMI). Phantom registration studies were performed to examine accuracy and robustness for each framework. In addition, an in vivo registration is performed to demonstrate feasibility of the data acquisition system in the operating room. Results indicate that SurfaceMI performed better in many cases than point-based (PBR) and iterative closest point (ICP) methods for registration of textured point clouds. Mean target registration error (TRE) for simulated deep tissue targets in a phantom were 1.0 +/- 0.2, 2.0 +/- 0.3, and 1.2 +/- 0.3 mm for PBR, ICP, and SurfaceMI, respectively. With regard to in vivo registration, the mean TRE of vessel contour points for each framework was 1.9 +/- 1.0, 0.9 +/- 0.6, and 1.3 +/- 0.5 for PBR, ICP, and SurfaceMI, respectively. The methods discussed in this paper in conjunction with the quantitative data provide impetus for using LRS technology within the model-updated image-guided surgery framework.

Adult↗

Incorporation of a laser range scanner into image-guided liver surgery: surface acquisition, registration, and tracking.

As image guided surgical procedures become increasingly diverse, there will be more scenarios where point-based fiducials cannot be accurately localized for registration and rigid body assumptions no longer hold. As a result, procedures will rely more frequently on anatomical surfaces for the basis of image alignment and will require intraoperative geometric data to measure and compensate for tissue deformation in the organ. In this paper we outline methods for which a laser range scanner may be used to accomplish these tasks intraoperatively. A laser range scanner based on the optical principle of triangulation acquires a dense set of three-dimensional point data in a very rapid, noncontact fashion. Phantom studies were performed to test the ability to link range scan data with traditional modes of image-guided surgery data through localization, registration, and tracking in physical space. The experiments demonstrate that the scanner is capable of localizing point-based fiducials to within 0.2 mm and capable of achieving point and surface based registrations with target registration error of less than 2.0 mm. Tracking points in physical space with the range scanning system yields an error of 1.4 +/- 0.8 mm. Surface deformation studies were performed with the range scanner in order to determine if this device was capable of acquiring enough information for compensation algorithms. In the surface deformation studies, the range scanner was able to detect changes in surface shape due to deformation comparable to those detected by tomographic image studies. Use of the range scanner has been approved for clinical trials, and an initial intraoperative range scan experiment is presented. In all of these studies, the primary source of error in range scan data is deterministically related to the position and orientation of the surface within the scanner's field of view. However, this systematic error can be corrected, allowing the range scanner to provide a rapid, robust method of acquiring anatomical surfaces intraoperatively.

Aged↗

Three-dimensional image registration of phantom vertebrae for image-guided surgery: a preliminary study.

OBJECTIVE: Applications of three-dimensional ultrasound (3D US) are emerging throughout the field of medicine. In this study, tracked, free-hand 3D phantom US images were mapped to computed tomograms (CT) as a development for image-guided surgery (IGS) of the spine. In the operating room, the registration of tracked 3D US images to other imaging modalities, such as CT, could allow the surgeon to identify more precisely the surgical target area prior to the incision. An independent quantitative measure of registration accuracy using a fiducial marker system was provided. METHODS: Three-dimensional free-hand US images of a phantom spine were created by tracking the transducer with an optical sensing system. Two sets of images were acquired from three lumbar vertebrae using 4.5- and 7.5-MHz transducers. These images were then segmented for the extraction of the posterior vertebral surface. Next, a surface-based registration of US to the corresponding segmented CT images was performed. Registration errors were computed as the distance between a set of target points transformed using the experimental transformation and the same set of target points transformed using fiducial markers as a gold standard. RESULTS: Results indicated that alignment of these image sets is feasible using only part of the vertebral surface. In particular, the regions of the spinous process and laminae were used for registration. Target registration errors (TREs) were found to be lowest using the highest resolution CT images. Using the CT scans with 2-mm slice thickness, the TRE was calculated to be 1.33 +/- 0.30 mm for the 7.5-MHz US data set and 2.81 +/- 0.10 mm for the 4.5-MHz US data set. Moreover, residual errors in these surface alignments were 0.69 +/- 0.18 mm and 0.61 +/- 0.20 mm for the 4.5- and 7.5-MHz sets, respectively. CONCLUSION: A rigid, surface-based registration of CT images to phantom spinal US images, acquired with a free-hand, tracked transducer, is achievable with a limited, easily obtainable portion of the vertebral surface.

Algorithms↗

Design and implementation of a PC-based image-guided surgical system.

In interactive, image-guided surgery, current physical space position in the operating room is displayed on various sets of medical images used for surgical navigation. We have developed a PC-based surgical guidance system (ORION) which synchronously displays surgical position on up to four image sets and updates them in real time. There are three essential components which must be developed for this system: (1) accurately tracked instruments; (2) accurate registration techniques to map physical space to image space; and (3) methods to display and update the image sets on a computer monitor. For each of these components, we have developed a set of dynamic link libraries in MS Visual C++ 6.0 supporting various hardware tools and software techniques. Surgical instruments are tracked in physical space using an active optical tracking system. Several of the different registration algorithms were developed with a library of robust math kernel functions, and the accuracy of all registration techniques was thoroughly investigated. Our display was developed using the Win32 API for windows management and tomographic visualization, a frame grabber for live video capture, and OpenGL for visualization of surface renderings. We have begun to use this current implementation of our system for several surgical procedures, including open and minimally invasive liver surgery.

Algorithms↗

Centroid-based maximum intensity projections.

PURPOSE: Maximum intensity projection (MIP) is a three-dimensional visualization technique for tomographic angiograms. While conventional MIPs display contralateral vascular anatomy, this study uses centroid calculations to remove this information. It is necessary to provide accurate, unambiguous vessel depiction and identical projections regardless of slice orientation. METHOD: A mathematical model was formed using parameters from clinical images of the head. The vessel widths from the resulting projections were measured and compared with the model. To test the consistency of the projection process, a clinical image set was reformatted and projections of the same view were compared. RESULTS: The vessel widths were smaller than in the model while varying interpolation and noise. Similar projection views were generated for all slice orientations, but some misalignment was present. CONCLUSION: Vessel width is affected by the ray's path length and interpolation method. Some slight misalignment is present because the reformatting process alters the centroid calculations.

Cerebral Angiography↗