Parallel synthesis and biophysical characterization of a degradable polymer library for gene delivery.

We recently reported the parallel synthesis of 140 degradable poly(beta-amino esters) via the conjugate addition of 20 primary or secondary amine monomers to seven different diacrylate monomers. To explore possible structure/function relationships and further characterize this class of materials, we investigated the ability of each DNA-complexing polymer to overcome important cellular barriers to gene transfer. The majority of vectors were found to be uptake-limited, but complexes formed from polymers B14 and G5 displayed high levels of internalization relative to "naked" DNA (18x and 32x, respectively). Effective diameter and zeta potential measurements indicated that, in general, small particle size and positive surface charge led to higher internalization rates. Of the 10 DNA/polymer complexes with the highest uptake levels, all had effective diameters less than 250 nm and nine had positive zeta potentials. Lysosomal trafficking was investigated by measuring the pH environment of delivered DNA. Complexes prepared with polymers G5, G10, A13, B13, A14, and B14 were found to have near neutral pH measurements, suggesting that they were able to successfully avoid trafficking to acidic lysosomes. This work highlights the value of parallel synthesis and screening approaches for the discovery of new polymers for gene delivery and the elucidation of structure/function relationships for this important class of materials.

3T3 Cells↗

Reactive polymer coatings: a first step toward surface engineering of microfluidic devices.

We report fabrication, characterization, and use of microfluidic analysis devices containing surface-immobilized cell-capturing molecules. Amino-terminated biotin ligands are immobilized onto the luminal surface of a microdevice and effectively support self-assembly of proteins, antibodies, and mammalian cells. For this purpose, chemical vapor deposition (CVD) polymerization is used to functionalize PDMS-made microfluidic devices with poly[para-xylylene carboxylic acid pentafluorophenolester-co-para-xylylene]. The resulting reactive coating shows excellent adhesion when deposited in thin films (approximately 100 nm, and the distribution of the pentafluorophenol ester groups is reasonably uniform within the microchannel inner surface, as examined by fluorescence microscopy. The utility of these devices for cell-based bioassays is demonstrated by monitoring the concentration-dependent effect of the disintegrin echistatin on cell adhesion. The described assay format could be relevant to clinical research in various fields, including angiogenesis research.

Animals↗

Poly(ethylene oxide)-modified poly(beta-amino ester) nanoparticles as a pH-sensitive biodegradable system for paclitaxel delivery.

The main objective of this study was to develop and characterize a pH-sensitive biodegradable polymeric nanoparticulate system for tumor-selective paclitaxel delivery. A representative hydrophobic poly(beta-amino ester) (poly-1) was synthesized by conjugate addition of 4,4'-trimethyldipiperidine with 1,4-butanediol diacrylate. Poly-1 (M(n) 10,000 daltons) nanoparticles were prepared by the controlled solvent displacement method in an ethanol-water system in the presence of Pluronic) F-108, a poly(ethylene oxide) (PEO)-containing non-ionic surfactant. Control and PEO-modified nanoparticles were characterized by Coulter counter, scanning electron microscopy (SEM), zeta potential measurements, and electron spectroscopy for chemical analysis (ESCA). Polymer degradation studies were performed in phosphate-buffered saline (PBS, pH 7.4) at 37 degrees C. Paclitaxel loading capacities and efficiencies were determined and release studies were performed in Tween)-80 (0.1%, w/v)-containing PBS at 37 degrees C. Control and PEO-modified nanoparticles, labeled with rhodamine-123, were incubated with BT-20 cells to examine the uptake and cellular distribution as a function of time. PEO-modified nanoparticles with an average size of 100-150 nm and a positive surface charge of 37.0 mV were prepared. SEM analysis showed distinct smooth, spherical particles. The ether (-C-O-) peak of the C(1s) envelope in ESCA confirmed the surface presence of PEO chains. Polymer biodegradation studies showed that almost 85% of the starting material degraded after 6 days. The maximum paclitaxel loading efficiency attained was 97% at 1.0% (w/w) of the drug. Paclitaxel release studies showed that approximately 10% was released in the first 24 h, 80% after 3 days, and the entire content was released in approximately 5 days. After 1 h of incubation, a large fraction of the administered control and PEO-modified poly-1 nanoparticles was internalized in BT-20 cells. Results of this study demonstrate that PEO-modified poly-1 nanoparticles could provide increased therapeutic benefit by delivering the encapsulated drug to solid tumors.

Drug Delivery Systems↗

A reversibly switching surface.

We report the design of surfaces that exhibit dynamic changes in interfacial properties, such as wettability, in response to an electrical potential. The change in wetting behavior was caused by surface-confined, single-layered molecules undergoing conformational transitions between a hydrophilic and a moderately hydrophobic state. Reversible conformational transitions were confirmed at a molecular level with the use of sum-frequency generation spectroscopy and at a macroscopic level with the use of contact angle measurements. This type of surface design enables amplification of molecular-level conformational transitions to macroscopic changes in surface properties without altering the chemical identity of the surface. Such reversibly switching surfaces may open previously unknown opportunities in interfacial engineering.

Adsorption↗

Rational design of low-molecular weight heparins with improved in vivo activity.

Heparin and low-molecular weight heparins (LMWHs), complex, sulfated polysaccharides isolated from endogenous sources, are potent modulators of hemostasis. Heparin and LMWHs interact with multiple components of the coagulation cascade to inhibit the clotting process. Pharmaceutical preparations of these complex polysaccharides, typically isolated from porcine intestinal mucosa, are heterogeneous in length and composition and, hence, highly polydisperse. Because of the structural heterogeneity of heparin and LMWHs, correlating their activity with a particular structure or structural motif has been a challenging task. Herein, we demonstrate a practical analytical method that enables the measurement of a structural correlate to in vivo anticoagulant function. With this understanding we have developed LMWHs with increased anticoagulant activity and decreased polydispersity. In addition to the pronounced anti-Xa and anti-IIa activity of these LMWHs, we also demonstrate that they possess desirable in vivo pharmacokinetic properties, the ability to cause the release of tissue factor pathway inhibitor (TFPI) from the endothelium, complete bioavailability through s.c. delivery, and the ability to inhibit both venous and arterial thromboses. Importantly, from a clinical safety point of view, unlike LMWHs presently used in the clinic, we show that these LMWHs are rapidly and completely neutralized by protamine. Together, the findings presented herein demonstrate a facile approach for the creation of designer LMWHs with optimal activity profiles.

Animals↗

A method to protect sensitive molecules from a light-induced polymerizing environment.

Systems that can be polymerized in situ upon exposure to light radiation may have significant applications in tissue engineering and drug delivery. However, the light-induced polymerization step, which is the requisite for this technology, could be potentially deleterious to sensitive bioactive agents (e.g., enzymes, cytokines, matrix metalloproteinases) being entrapped. In this study, a method to protect sensitive molecules from a light-induced polymerizing environment is proposed. This method is based on the idea that nonaccessible substances cannot interact with the polymerizing species. To examine this concept, two model enzymes-namely, horseradish peroxidase and alpha-glucosidase-were protected by gelatin-based wet granulation and incorporated within a cured polyethylene glycol dimethacrylate, a photocurable monomer, under different conditions. Unprotected enzymes were used as controls. Enzymes were then allowed to diffuse out of the polymerized matrices. The activity and total enzyme recovered from these matrices by passive diffusion were compared to ascertain the extent of activity retention. Matrix assisted laser desorption ionization mass spectrometry combined with time of flight mass spectrometry (MALDI-TOF) was used to determine changes in enzyme molecular weight. During the first 24 h of diffusion from the polymerized matrices, unprotected enzymes consistently showed a loss of activity ranging from 10-66%, depending on the matrix composition and enzyme properties. In contrast, protected enzymes retained over 94% of their activity irrespective of the experimental setting. The loss of activity appears to be a direct consequence of the polymerizing environment.

Acrylates↗

A potential approach for decreasing the burst effect of protein from PLGA microspheres.

A central issue in controlled delivery of therapeutics from biodegradable microspheres is the immediate burst of drug release upon injection. This burst is often observed with microsphere systems made by the double emulsion (w/o/w) technique, and may be prevented by improving the drug distribution throughout the polymer matrix. To this end, protein and polymer (poly-lactide-co-glycolide or PLGA) were dissolved within the same solvent system, and micron-sized microspheres were created from this solution by spontaneous emulsification. Improved protein loading was achieved by ion-pairing the protein with charged surfactants to increase solubility in the single-phase solvent system. Both in vitro and in vivo results showed a much diminished burst: compared to microspheres made by double emulsion, it was reduced over 10-fold.

Animals↗

Evaluation of fluorescent probe surface intensities as an indicator of transdermal permeant distributions using wide-area two-photon fluorescence microscopy.

The application of high-speed two-photon fluorescence microscopy (HTPM) to examine transdermal transport processes has enabled the noninvasive visualization of permeant spatial distributions over a larger, more clinically relevant wide area of the skin. Earlier studies demonstrated that the transdermal fluorescent probe distribution over a 2 x 2 mm skin area was well represented by a significantly reduced sampling of the 400 microscale skin sites (100 x 100 microm) constituting the wide area. In the present study, the 400 microscale skin sites are considered individually, and the site-to-site variability in permeant distributions is used as a model to reflect the range in experimentally measured skin permeabilities resulting from the inherent stratum corneum structural heterogeneity. The correlation established between the permeant surface intensity and the corresponding permeant intensity gradient at each skin site provides an indication of the potential for screening transdermal permeant distributions solely based on the evaluation of microscale permeant surface intensities. The strong linear correlation between the intensity gradient and the surface intensity for the hydrophilic model permeant, sulforhodamine B, demonstrated that surface intensities provide a robust indicator of the corresponding transdermal probe distributions at the microscale. For the hydrophobic model permeant, rhodamine B hexyl ester, however, weak correlations were observed between these two parameters. This result suggests that the stratum corneum microscale surface intensity does not validly capture the corresponding intensity gradients for the entire range of skin permeabilities typically encountered as a result of the inherent stratum corneum heterogeneity.

Administration, Cutaneous↗

Biocompatibility and biofouling of MEMS drug delivery devices.

The biocompatibility and biofouling of the microfabrication materials for a MEMS drug delivery device have been evaluated. The in vivo inflammatory and wound healing response of MEMS drug delivery component materials, metallic gold, silicon nitride, silicon dioxide, silicon, and SU-8(TM) photoresist, were evaluated using the cage implant system. Materials, placed into stainless-steel cages, were implanted subcutaneously in a rodent model. Exudates within the cage were sampled at 4, 7, 14, and 21 days, representative of the stages of the inflammatory response, and leukocyte concentrations (leukocytes/microl) were measured. Overall, the inflammatory responses elicited by these materials were not significantly different than those for the empty cage controls over the duration of the study. The material surface cell density (macrophages or foreign body giant cells, FBGCs), an indicator of in vivo biofouling, was determined by scanning electron microscopy of materials explanted at 4, 7, 14, and 21 days. The adherent cellular density of gold, silicon nitride, silicon dioxide, and SU-8(TM) were comparable and statistically less (p<0.05) than silicon. These analyses identified the MEMS component materials, gold, silicon nitride, silicon dioxide, SU-8(TM), and silicon as biocompatible, with gold, silicon nitride, silicon dioxide, and SU-8(TM) showing reduced biofouling.

Animals↗

In situ pore formation in a polymer matrix by differential polymer degradation.

A new approach for the in situ formation of porosity in a matrix based on differential polymer degradation has been studied. This approach exploits the differences in polymer properties such as molecular weight, hydrophilicity (hydrophobicity), and degradation to induce preferential degradation of one phase in a biphasic polymer system. Biphasic polymer systems polymers derived from alpha-hydroxy acids and poly(anhydrides), which vary in their erosion characteristics (surface vs. bulk) and hydrophobicities were studied. In addition to examining the generality of the approach, potential advantages of such systems in the context of tissue engineering and drug delivery are briefly discussed.

Anhydrides↗

Polyhistidine-PEG:DNA nanocomposites for gene delivery.

Complexation of plasmid DNA with polycations is a popular method by which to transfer therapeutic nucleic acid sequences to cells. One caveat of the approach is that the positive zeta potential of the complexes facilitates interaction with blood constituents, leading to serum protein adsorption and complement activation. As a countermeasure, investigators have developed polycations combined with polyethylene glycol (PEG) to create complexes with reduced protein adsorption potential. We have designed and synthesized PEG-polyhistidine conjugates to evaluate the material class as potential gene delivery vehicles. Two conjugate architectures (comb-shaped and linear A-B block copolymers) were synthesized and formulated with plasmid DNA. The complexes were characterized with respect to DNA complexation capacity, hydrodynamic diameter, zeta potential, in vitro cytotoxicity and transfection capacity in a model cell line. PEG content of the conjugate significantly influenced the hydrodynamic diameter of the DNA:conjugate composite in aqueous solution. For comb-shaped conjugates steric hindrance attributed to PEG led to a direct relationship between the PEG content and the complex size. Both architectures could condensed plasmid DNA into complexes with hydrodynamic diameters <150 nm. Complexation of DNA with the polyhistidine-PEG conjugates resulted in nanocomposites with negative zeta potentials that retarded DNase I-mediated hydrolysis, and all conjugates showed low cytotoxicity to macrophages cultured in vitro. The transfection efficiency was approximately equivalent to DNA:polylysine complexes. The formulation characteristics and low cytotoxicity suggest that polyhistidine-PEG conjugates may be useful for gene delivery.

Animals↗

Prolonged duration local anesthesia from tetrodotoxin-enhanced local anesthetic microspheres.

There is interest in developing prolonged duration local anesthesics. Here we examine whether tetrodotoxin (TTX) can be used to prolong the block from bupivacaine microspheres with and without dexamethasone. Rats received sciatic nerve blocks with 75 mg of microspheres containing 0.05% (w/w) TTX, 50% (w/w) bupivacaine and/or 0.05% (w/w) dexamethasone. 0.1% (w/w) TTX microspheres were also tested. The carrier fluid contained 1:100,000 epinephrine. Nociceptive and motor blockade of the hindpaw were quantified. Nerves and adjacent muscles were harvested 2 weeks after injection for histological assessment by light microscopy. The median nociceptive block duration in hours from the microsphere groups were: bupivacaine=6.2, 0.05% TTX=0, bupivacaine+TTX=35.3, bupivacaine+dexamethasone=31.3, TTX+dexamethasone=8.1, TTX+bupivacaine+dexamethasone=221.7. Some animals receiving particles containing 0.05% TTX had deficits in the uninjected extremity; all animals receiving 0.1% (w/w) TTX particles died. Pockets of particles were associated with localized inflammation, and all samples showed some evidence of myotoxicity in the vicinity of the injection. The nerves themselves appeared intact. In summary, coencapsulation of TTX in controlled release devices containing bupivacaine and dexamethasone resulted in very prolonged nerve blocks. As formulated here, this preparation had a narrow margin of safety. While the myotoxicity appears consistent with the well-known reversible myotoxicity associated with local anesthetics, its long-term significance remains to be established.

Anesthetics, Local↗

Advancing the field of drug delivery: taking aim at cancer.

Drug delivery systems for cancer therapeutics have now been used by millions of patients and have resulted in the creation of new therapies as well as significantly improving existing ones. Here we discuss a number of the drug delivery systems that have been approved by regulatory authorities and that are currently in clinical use, such as controlled delivery of cancer therapeutics, local chemotherapy, polymer drug conjugates, liposomal systems, and transdermal drug delivery patches. The next generation of "smart" drug delivery approaches such as controlled release microchips are discussed as are some of the future challenges and directions in this field.

Absorbable Implants↗

Novel microemulsion enhancer formulation for simultaneous transdermal delivery of hydrophilic and hydrophobic drugs.

PURPOSE: Microemulsion (ME) systems allow for the microscopic co-incorporation of aqueous and organic phase liquids. In this study, the phase diagrams of four novel ME systems were characterized. METHODS: Water and IPM composed the aqueous and organic phases respectively, whereas Tween 80 served as a nonionic surfactant. Transdermal enhancers such as n-methyl pyrrolidone (NMP) and oleyl alcohol were incorporated into all systems without disruption of the stable emulsion. RESULTS: A comparison of a W/O ME with an O/W ME of the same system for lidocaine delivery indicated that the O/W ME provides significantly greater flux (p < 0.025). The water phase was found to be a crucial component for flux of hydrophobic drugs (lidocaine free base, estradiol) as well as hydrophilic drugs (lidocaine HCl, diltiazem HCl). Furthermore, the simultaneous delivery of both a hydrophilic drug and a hydrophobic drug from the ME system is indistinguishable from either drug alone. Enhancement of drug permeability from the O/W ME system was 17-fold for lidocaine free base, 30-fold for lidocaine HCl, 58-fold for estradiol, and 520-fold for diltiazem HCl. CONCLUSIONS: The novel microemulsion systems in this study potentially offers many beneficial characteristics for transdermal drug delivery.

Administration, Cutaneous↗

pH-triggered release of macromolecules from spray-dried polymethacrylate microparticles.

PURPOSE: pH-triggered microparticles release their therapeutic payloads at acidic pH (e.g., in the phagosome), making intracellular drug delivery more efficient. Here we modify lipid-based microparticles that are safe and efficacious in nerve and brain and are potentially inhalable, making them pH-triggerable by incorporating an acid-soluble polymethacrylate, Eudragit E100 (E100). METHODS: Microparticles were produced by spray-drying and characterized by electron microscopy, Coulter counting, density measurement, and release kinetics of fluorescently labeled proteins. In addition, biocompatibility and cellular uptake were observed in rats. RESULTS: Microparticles were spheroids 3 to 5 microm in diameter with densities of 0.12 to 0.25 g/L. Microparticles with 20% (w/w) or more E100 demonstrated slow release of fluorescently labeled proteins at pH 7.4 but rapid release at pH 5. pH-triggerability was maintained for over 2 weeks in solution. Protein loadings of 0.2-20% (w/w) were pH-triggerable. Histologic examination of particles in rat connective tissue near nerve and muscle demonstrated biocompatibility aside from muscle edema in the cell layers adjacent to the particles and a localized inflammatory reaction with macrophages laden with microparticles. CONCLUSIONS: Microparticles containing E100 were pH-triggerable for many days and were taken up by macrophages, suggesting that they may be useful for intracellular drug delivery.

Acrylates↗

Small-scale systems for in vivo drug delivery.

Recent developments in the application of micro- and nanosystems for drug administration include a diverse range of new materials and methods. New approaches include the on-demand activation of molecular interactions, novel diffusion-controlled delivery devices, nanostructured 'smart' surfaces and materials, and prospects for coupling drug delivery to sensors and implants. Micro- and nanotechnologies are enabling the design of novel methods such as radio-frequency addressing of individual molecules or the suppression of immune response to a release device. Current challenges include the need to balance the small scale of the devices with the quantities of drugs that are clinically necessary, the requirement for more stable sensor platforms, and the development of methods to evaluate these new materials and devices for safety and efficacy.

Biosensing Techniques↗

Multi-pulse drug delivery from a resorbable polymeric microchip device.

Controlled-release drug delivery systems have many applications, including treatments for hormone deficiencies and chronic pain. A biodegradable device that could provide multi-dose drug delivery would be advantageous for long-term treatment of conditions requiring pulsatile drug release. In this work, biodegradable polymeric microchips were fabricated that released four pulses of radiolabelled dextran, human growth hormone or heparin in vitro. Heparin that was released over 142 days retained on average 96 +/- 12% of its bioactivity. The microchips were 1.2 cm in diameter, 480-560 microm thick and had 36 reservoirs that could each be filled with a different chemical. The devices were fabricated from poly(L-lactic acid) and had poly(D,L-lactic-co-glycolic acid) membranes of different molecular masses covering the reservoirs. A drug delivery system can be designed with the potential to release pulses of different drugs at intervals after implantation in a patient by using different molecular masses or materials for the membrane.

Absorbable Implants↗