PubMed Health⌕ Search

Biomedical subjects

Robert M Richardson

Publications and source records attributed to Robert M Richardson.

3 recordsLinked to original sources

Effect of surfactant and solvent properties on the stacking behavior of non-aqueous suspensions of organically modified clays.

Montmorillonite clay was treated with quaternary ammonium surfactants with 1-3 long chains of 10-18 carbons to form organoclays which can be suspended in non-aqueous solvents. The effects of surfactant chain length, number of long chains, and the properties of the solvent on the colloidal behavior of the surfactant coated clay plates were studied using small-angle X-ray scattering. The scattering data were modeled using a one-dimensional aggregation theory to describe the stacking of the clay plates. The plates self-organize into stacks with a reproducible basal spacing in the range of 30-50 A, and for each surfactant, the basal spacing falls into one of two preferred distances. We interpret this by considering that the surfactant layer on the clay has two strata, one being the polar near-clay headgroup region and the other the nonpolar alkane chain region. Polar solvents will swell the polar stratum preferentially while nonpolar solvents will swell the nonpolar stratum of the surfactant. As the nonpolar stratum is larger than the polar one, the nonpolar solvents increase the basal spacing between the clay plates more than the polar solvents. The number of long chains on the surfactant does not have an effect on the basal spacing, as the density of surfactant molecules on the surface is low enough to allow the unimpeded swelling of the chains. The one-dimensional aggregation theory can be used to determine the number of plates in a stack, but the effect of changing clay particle size or concentration is not as great as would be expected from this theory. This may be due to the formation of large-scale structures in the suspensions which prevent a true equilibrium stack size being attained.

Aluminum Silicates↗

Smectic order induced at homeotropically aligned nematic surfaces: a neutron reflection study.

Neutron reflection was used to measure the buildup of layers at a solid surface as the smectic phase is approached from higher temperatures in a nematic liquid crystal. The liquid crystal was 4-octyl-4'-cyanobiphenyl (8CB), and the solid was silicon with one of five different surface treatments that induce homeotropic alignment: (i) silicon oxide; (ii) a cetyltrimethylammonium bromide coating; (iii) an octadecyltrichlorosilane monolayer; (iv) an n-n-dimethyl-n-octadecyl-3- aminopropyltrimethyloxysilyl chloride monolayer; and (v) a lecithin coating. The development of surface smectic layers in the nematic phase of 8CB was followed by measuring specular reflectivity and monitoring the pseudo-Bragg peak from the layers. The scattering data were processed to remove the scattering from short-ranged smecticlike fluctuations in the bulk nematic phase from the specular reflection. The pseudo-Bragg peak at scattering vector Q approximately 0.2 A(-1) therefore corresponded to the formation of long-range smectic layers at the surface. The amplitude of the smectic density wave decayed with increasing distance from the surface, and the characteristic thickness of this smectic region diverged as the transition temperature was approached. It was found that the characteristic thickness for some of the surface treatments was greater than the correlation length in the bulk nematic. The different surfaces gave different values of the smectic order parameter at the surface. This suggests that the interaction with the surface is significantly different from a "hard wall" which would give the same values of the smectic order parameter and penetration depths similar to the bulk correlation length. Comparison of the different surfaces also suggested that the strength and range of the surface smectic ordering may be varied independently.

Journal Article↗

Monitoring hemodialysis vascular access by digital phonoangiography.

We are intrigued by the possibility of using digital spectral analysis to detect hemodialysis vascular access stenosis. Such a monitor could be inexpensive, noninvasive, and portable enough to allow continuous monitoring. This report suggests how individuals wishing to conduct such research can use a simple but effective transducer design we have employed, how the data so obtained can be analyzed in the time and frequency domains using inexpensive digital signal processing software available via the Internet, and how data recordings might be shared via the Internet to facilitate collaboration.

Arteriovenous Shunt, Surgical↗