PubMed Health⌕ Search

Biomedical subjects

Robert M Sweet

Publications and source records attributed to Robert M Sweet.

7 recordsLinked to original sources

X-ray data collection from macromolecular crystals.

Instruments, methods, and software for modern macromolecular crystallography is becoming so effective that molecular biologists often can solve structures from their crystals by working "without a license." In this chapter, the authors attempt to demystify some of the apparatus and techniques by providing a roadmap. Current methods for collecting X-ray diffraction data from macromolecular crystals are described. The principles of operation of the required X-ray sources, optics, goniometers, and detectors are outlined, and a typical data collection protocol is presented. Optimization of data quality is a pivotal stage in the whole crystallographic process, so much attention is given to the detailed setting up of the experiment. This is followed by a summary of the basic ideas behind the diffraction image-processing packages and their application to data reduction. Despite the increasingly "black box" nature of these computer programs, understanding how they extract the intensities, errors, and indices from the data can make subsequent structure solution and refinement much easier.

Crystallization↗

Integrated software for macromolecular crystallography synchrotron beamlines II: revision, robots and a database.

This manuscript chronicles the evolution of software used originally to control a diffractometer at a macromolecular crystallography beamline. The system has been augmented and rewritten. A modular and carefully organized suite of programs now handles the whole experimental environment from a single vantage point. It provides automatic logging of the experiment and communication with the user, all the way from an initial proposal to perform the work to the end of data collection. This has included construction of a relational database to organize all details of the experiment and incorporation of a robotic specimen changer to provide automation for high-throughput applications.

Crystallography↗

Beamline X29: a novel undulator source for X-ray crystallography.

A high-flux insertion device and beamline for macromolecular crystallography has been built at the National Synchrotron Light Source (NSLS) that employs a mini-gap undulator source developed by the NSLS. The mini-gap undulator at beamline X29 is a hybrid-magnet device of period 12.5 mm operating at proven gaps of 3.3-10 mm. The beamline provides hard X-rays for macromolecular crystallography experiments from the second and third harmonics over an energy range of 5-15 keV. The X-ray optics is designed to deliver intense and highly collimated X-rays. Horizontal focusing is achieved by a cryogenically cooled sagittally focusing double-crystal monochromator with approximately 4.1:1 demagnification. A vertical focusing mirror downstream of the monochromator is used for harmonic rejection and vertical focusing. The experimental station hosts an Area Detector Systems Quantum 315 CCD detector with 2.2 s readout time between exposures and Crystal Logic goniostat for crystal rotation and detector positioning. An auto-mounter crystal changer has been installed to facilitate the high-throughput data collection required by the major users, which includes structural genomics projects and the Macromolecular Crystallography Research Resource mail-in program. X29 is 10(3) times brighter than any existing bending-magnet beamline at NSLS with an actual flux of 2.5 x 10(11) photons s(-1) through a 0.12 mm square aperture at 11.271 keV.

Crystallography, X-Ray↗

Virtual reality as an adjunctive pain control during transurethral microwave thermotherapy.

The management of pain during clinic transurethral microwave thermotherapy (TUMT) can be challenging. Pain can lead to increased pelvic blood flow, which dissipates the energy delivered, limiting the amount of heat delivered to the prostate. In this report, we describe the novel use of virtual reality distraction as an adjunctive mechanism for local anesthesia during TUMT in a 67-year-old man. This report is novel in being, to our knowledge, the first to demonstrate the efficacy of virtual reality in an elderly patient and the first documented use for a urologic clinic procedure. We believe it is also the first to demonstrate efficacy for the control of thermally induced pain.

Aged↗

Protein Data Bank depositions from synchrotron sources.

A survey and analysis of Protein Data Bank (PDB) depositions from international synchrotron radiation facilities, based on the latest released PDB entries, are reported. The results (http://asdp.bnl.gov/asda/Libraries/) show that worldwide, every year since 1999, more than 50% of the deposited X-ray structures have used synchrotron facilities, reaching 75% by 2003. In this web-based database, all PDB entries among individual synchrotron beamlines are archived, synchronized with the weekly PDB release. Statistics regarding the quality of experimental data and the refined model for all structures are presented, and these are analysed to reflect the impact of synchrotron sources. The results confirm the common impression that synchrotron sources extend the size of structures that can be solved with equivalent or better quality than home sources.

Crystallography, X-Ray↗

Three-beam interference is a sensitive measure of the efficacy of macromolecular refinement techniques.

Triplet phases recorded from insulin crystals were used to measure the improvement of phases during model refinement and to quantify the contribution made by each step in the refinement. Conventional amplitude data were recorded to 1.5 A resolution from rhombohedral pig insulin crystals using 1.54 A Cu Kalpha radiation. An initial atomic model and starting phases were obtained from a published structure and the atomic model was refined against the amplitude data using CNS. The refined phases were compared with 800 triplet phases that were measured from similar crystals using a three-beam interference technique and 1.1 A wavelength synchrotron radiation. The solvent region was improved further using a novel density-modification procedure. Calculated triplet phases were obtained from the model after each step in the refinement and were compared with the recorded triplet phases. The average difference between the recorded triplet phases and the calculated triplet phases was used as an unbiased measure of the correctness of the model at each stage in the refinement. The average individual phase error was estimated from discrepancies from triplet phases after each refinement step. Conventional atomic refinement of an approximate starting model reduced the average individual phase error from 21.6 to 14.7 degrees. Improvement of the solvent region, including the difference-map flattening procedure, reduced the individual phase error by a further 2.6 degrees. Modeling the discrete disorder of four amino acids accounted for an additional 0.5 degrees improvement and the final individual phase error was 11.6 degrees.

Crystallography, X-Ray↗

Crystallographic structure at 1.6-A resolution of the human adenovirus proteinase in a covalent complex with its 11-amino-acid peptide cofactor: insights on a new fold.

The crystal structure of the human adenovirus proteinase (AVP), a cysteine proteinase covalently bound to its 11-amino-acid peptide cofactor pVIc, has been solved to 1.6-A resolution with a crystallographic R-factor of 0.136, R(free)=0.179. The fold of AVP-pVIc is new and the structural basis for it is described in detail. The polypeptide chain of AVP folds into two domains. One domain contains a five-strand beta-sheet with two peripheral alpha-helices; this region represents the hydrophobic core of the protein. A second domain contains the N terminus, several C-terminal alpha-helices, and a small peripheral anti-parallel beta-sheet. The domains interact through an extended polar interface. pVIc spans the two domains like a strap, its C-terminal portion forming a sixth strand on the beta-sheet. The active site is in a long, deep groove located between the two domains. Portions are structurally similar to the active site of the prototypical cysteine proteinase papain, especially some of the Calpha backbone atoms (r.m.s. deviation of 0.354 A for 12 Calpha atoms). The active-site nucleophile of AVP, the conserved Cys(122), was shown to have a pK(a) of 4.5, close to the pK(a) of 3.0 for the nucleophile of papain, suggesting that a similar ion pair arrangement with His(54) may be present in AVP-pVIc. The interactions between AVP and pVIc include 24 non-beta-strand hydrogen bonds, six beta-strand hydrogen bonds and one covalent bond. Of the 204 amino acid residues in AVP, 33 are conserved among the many serotypes of adenovirus, and these aid in forming the active site groove, are involved in substrate specificity or interact between secondary structure elements.

Amino Acid Motifs↗