Computing oxygen-enhanced ventilation maps using correlation analysis.

Correlation maps of oxygen-enhanced ventilation were obtained in nine healthy volunteers using complete and selected image series. The complete series included all images acquired with the subjects alternately inhaling room air and 100% oxygen. The selected series were the subsets of the complete series and included only co-registered images that showed matched diaphragmatic position at maximal expiration. Cross-correlation was computed between the time response function of each pixel and the input function representing the alternation between periods of room air and 100% oxygen inhalation. The confidence level for the correlation analysis was set to 0.01. Pulmonary parenchymal anatomy was consistently reproduced throughout the lung, even in anterior slices where published data have reported correlation problems. The overall average correlation coefficient was 0.66 +/- 0.07 for the complete series and 0.75 +/- 0.08 for the selected series. It was concluded that correlation analysis could be used to reconstruct qualitative oxygen-enhanced ventilation maps.

Adult↗

Simultaneous magnetic resonance gadolinium-enhanced 2D perfusion and 3D angiographic imaging.

A method was implemented and tested that allows the simultaneous acquisition of magnetic resonance 2D slice selective perfusion and 3D angiographic data during a single bolus injection of a contrast agent. High quality contrast-enhanced perfusion images and angiograms of the lung, kidney and heart were obtained in healthy volunteers. Combined perfusion and angiography provided additional information with an acceptable increase in acquisition time. No image artifacts were attributed to the technique. The combined information may be useful in detecting, as well as characterizing, vascular abnormalities.

Adult↗

Rapid MR imaging by sensitivity profile indexing and deconvolution reconstruction (SPID).

A new parallel MR imaging technique, which uses localized information from the elements of a multi-coil array to accelerate imaging, is described. The technique offers an alternative reconstruction approach to currently available techniques (e.g., SMASH and SENSE). Following a partial k-space data acquisition, image reconstruction in this approach proceeds in two steps: first, fitting the measured coil sensitivities to a set of partially localized target functions, a blurred intermediate image of the studied object is produced. Blurring is obtained in a systematic manner, forming images of the studied object convolved with a known convolution kernel. Full spatial resolution is then recovered by deconvolution of the blurred images with the known kernel function. The technique offers flexibility in the arrangement of the acquired signal data k-lines, and a mechanism for controlling reconstruction quality through the convolution the deconvolution procedure. The technique was validated in phantom and in vivo imaging experiments demonstrating high time reduction factors.

Brain↗

Gender differences and normal left ventricular anatomy in an adult population free of hypertension. A cardiovascular magnetic resonance study of the Framingham Heart Study Offspring cohort.

OBJECTIVES: We sought to derive gender-specific cardiovascular magnetic resonance (CMR) reference values for normative left ventricular (LV) anatomy and function in a healthy adult population of clinically relevant age. BACKGROUND: Cardiovascular magnetic resonance imaging is increasingly applied in the clinical setting, but age-relevant, gender-specific normative values are currently unavailable. METHODS: A representative sample of 318 Framingham Heart Study (FHS) Offspring participants free of clinically overt cardiovascular disease underwent CMR examination to determine LV end-diastolic and end-systolic volume (EDV and ESV, respectively), mass, ejection fraction (EF) and linear dimensions (wall thickness, cavity length). Subjects with a clinical history of hypertension or those with a systolic blood pressure > or =140 mm Hg or diastolic pressure > or =90 mm Hg at any FHS cycle examination were excluded, leaving 142 subjects (63 men, 79 women; age 57 +/- 9 years). RESULTS: All volumetric (EDV, ESV, mass) and unidimensional measures were significantly greater (p < 0.001) in men than in women and remained greater (p < 0.02) after adjustment for subject height. Volumetric measures were greater (p < 0.001) in men than in women after adjustment for body surface area (BSA), but there were increased linear dimensions in women after adjustment for BSA. In particular, end-diastolic dimension indexed to BSA was greater in women (p < 0.001) than in men. There were no gender differences in global LVEF (men = 0.69; women = 0.70). CONCLUSIONS: Cardiovascular magnetic resonance measures of LV volumes, mass and linear dimensions differ significantly according to gender and body size. This study provides gender-specific normal CMR reference values, uniquely derived from a population-based sample of persons free of cardiovascular disease and clinical hypertension. These data may serve as a reference to identify LV pathology in the adult population.

Adult↗

Influence of oxygen flow rate on signal and T(1) changes in oxygen-enhanced ventilation imaging.

PURPOSE: To investigate the optimal oxygen flow rate for oxygen-enhanced MR ventilation imaging. MATERIALS AND METHODS: Using a cardiac-triggered nonselective inversion recovery (IR) half Fourier single-shot fast spin echo sequence, series of images were acquired with the subject alternately inhaling room air and 100% oxygen. Oxygen flow rates of 5 L/min, 10 L/min, 15 L/min, 20 L/min, and 25 L/min were studied, and signal intensity from the oxygen-enhanced ventilation images and T(1) of the lung were measured. RESULTS: The average signal intensity was 63.0 +/- 21.0 for 5 L/min, 98.7 +/- 26.8 for 10 L/min, 133.8 +/- 20.0 for 15 L/min, 138.7 +/- 19.7 for 20 L/min, and 139.2 +/- 37.9 for 25 L/min. The average T(1)'s of the lung were 1399 msec +/- 130 msec for room air, 1314 msec +/- 101 msec for 5 L/min, 1276 msec +/- 105 msec for 10 L/min, 1207 msec +/- 71 msec for 15 L/min, 1206 msec +/- 90 msec for 20 L/min, and 1207 msec +/- 42 msec for 25 L/min. CONCLUSION: The optimal flow rate is 15 L/min for oxygen-enhanced ventilation imaging.

Adult↗

MR assessment of left ventricular function: quantitative comparison of fast imaging employing steady-state acquisition (FIESTA) with fast gradient echo cine technique.

PURPOSE: To evaluate the agreement of fast imaging employing steady-state acquisition (FIESTA) cine technique with segmented k-space fast gradient echo (GRE) cine technique when using them for assessment of cardiac function. MATERIALS AND METHODS: Eleven MR cine studies were performed on six healthy volunteers and five patients, using FIESTA and fast GRE techniques. The quantitative measurements of ventricular function obtained from the two techniques were compared. The data analysis was performed by two observers independently. RESULTS: Compared to fast GRE cine technique, FIESTA cine technique consistently resulted in higher end-diastolic volume (10.2%) and end-systolic volume (21.6%), but lower myocardial mass of left ventricle (19.2%) and ejection fraction (9.9%). The stroke volume obtained from the two techniques was very close. The primary explanation for this variability is that the two techniques have different mechanisms on establishing signal contrast. CONCLUSION: Compared to fast GRE technique, FIESTA provides significantly different results when using it for assessment of left ventricular function. It is important to consider this difference in the assessment of cardiac function.

Adult↗

Ventilation-perfusion ratio of signal intensity in human lung using oxygen-enhanced and arterial spin labeling techniques.

This study investigates the distribution of ventilation-perfusion (V/Q) signal intensity (SI) ratios using oxygen-enhanced and arterial spin labeling (ASL) techniques in the lungs of 10 healthy volunteers. Ventilation and perfusion images were simultaneously acquired using the flow-sensitive alternating inversion recovery (FAIR) method as volunteers alternately inhaled room air and 100% oxygen. Images of the T(1) distribution were calculated for five volunteers for both selective (T(1f)) and nonselective (T(1)) inversion. The average T(1) was 1360 ms +/- 116 ms, and the average T(1f) was 1012 ms +/- 112 ms, yielding a difference that is statistically significant (P < 0.002). Excluding large pulmonary vessels, the average V/Q SI ratios were 0.355 +/- 0.073 for the left lung and 0.371 +/- 0.093 for the right lung, which are in agreement with the theoretical V/Q SI ratio. Plots of the V/Q SI ratio are similar to the logarithmic normal distribution obtained by multiple inert gas elimination techniques, with a range of ratios matching ventilation and perfusion. This MRI V/Q technique is completely noninvasive and does not involve ionized radiation. A limitation of this method is the nonsimultaneous acquisition of perfusion and ventilation data, with oxygen administered only for the ventilation data.

Adult↗

Band artifacts due to bulk motion.

Band artifacts due to bulk motion were investigated in images acquired with fast gradient echo sequences. A simple analytical calculation shows that the width of the artifacts has a square-root dependence on the velocity of the imaged object, the time taken to acquire each line of k-space and the field of view in the phase-encoding direction. The theory furthermore predicts that the artifact width can be reduced using parallel imaging by a factor equal to the square root of the acceleration parameter. The analysis and results are presented for motion in the phase- and frequency-encoding directions and comparisons are made between sequential and centric ordering. The theory is validated in phantom experiments, in which bulk motion is simulated in a controlled and reproducible manner by rocking the scan table back and forth along the bore axis. Preliminary cardiac studies in healthy human volunteers show that dark bands may be observed in the endocardium in images acquired with nonsegmented fast gradient echo sequences. The fact that the position of the bands changes with the phase-encoding direction suggests that they may be artifacts due to motion of the heart walls during the image acquisition period.

Artifacts↗

Imaging the cerebrovascular tree in the cadaveric head for planning surgical strategy.

OBJECTIVE: The objective of the study was to identify whether an integration of cadaveric dissections with preoperative imaging information may enable a better understanding of pathological anatomy, especially vascular lesions, and thus allow for greater precision in surgical planning. METHODS: We selected a computed tomographic contrast agent and experimentally determined the proportion of it that could mix compatibly with the silicone compound. The resultant mixture was injected into the cerebrovascular systems of six fresh human cadaveric heads. The specimens underwent computed tomography for the purpose of digital virtual exposures in parallel with laboratory dissections performed on these specimens. RESULTS: The 1:8 ratio of contrast agent to silicone rubber was determined to be appropriate for both computed tomography and subsequent laboratory dissection of the specimens. The blood vessels in computed tomographic scans demonstrated a higher attenuation than surrounding soft tissues. The opacity consistency of the injected vessels was a critical parameter for a clear three-dimensional rendering of the vascular structures in the natural surroundings of the skull base. Static and dynamic three-dimensional images of the cadaveric vascular tree were obtained as viewed through surgical corridors of various skull base approaches. CONCLUSION: We demonstrated a new cadaveric preparation model for imaging and dissection. This model allows for static and dynamic three-dimensional examination of the surgical anatomy from a neurosurgeon's perspective. It may facilitate the study of cerebrovascular system morphology/pathology in relation to the skull base as a tool for surgical planning.

Brain↗

Significance of early CT signs in acute stroke. A CT scan-diffusion MRI study.

OBJECTIVE: To study the pathophysiology of early CT signs. BACKGROUND: Early CT signs, due to an increase in tissue water content, are commonly attributed to cytotoxic edema and development of irreversible injury. This may have important implications for thrombolysis. METHODS: In patients with acute ischemic stroke in the middle cerebral artery territory, the areas of early CT signs and diffusion weighted imaging (DWI) hypersignal were independently assessed and drawn on a standardized atlas. Then, patients were classified into three groups (early CT signs larger than, similar to or smaller than DWI hypersignal) and compared with perfusion weighted imaging (PWI). RESULTS: Of 16 patients, CT scanning was performed with a median time of 3 h after onset and early CT scan signs were recorded in 10/16 patients (62.5%). DWI signal hyperintensity was present in 15/16 (94%) patients. In 7/16 (43%) patients, the area with early CT scan signs was larger than the DWI lesion ('CT-larger group'). Only in 2/16 (12%) patients were the areas matching ('matching group'). In 7/16 (43%) the DWI lesion was larger than the early CT scan signs area ('DWI-larger group'). When compared with PWI, the areas of early CT signs were larger than DWI hypersignal and were matching with PWI abnormalities (rMTT) in 2 cases, suggesting that they may represent a reversible process. CONCLUSIONS: Early CT signs might have a potential dual fate: infarction or reversibility. Other techniques of recognizing reversible ischemic damage, such as DWI-PWI, are needed to improve acute stroke diagnosis and management.

Acute Disease↗