Biomedical subjects
Robert Rej
Publications and source records attributed to Robert Rej.
Immunoassay of estradiol: unanticipated suppression by unconjugated estriol.
BACKGROUND: Accurate measurement of estradiol is important in clinical settings. The quality of laboratory estimations of estradiol may be assessed through external quality-assurance surveys. METHODS: Estradiol was measured by microparticle enzyme immunoassay (MEIA) and other immunoassays. Proficiency testing of medical laboratories was conducted using samples prepared from normal male human serum supplemented with exogenous estradiol and other steroid and nonsteroid hormones, and participant laboratories measured estradiol by a variety of commonly used immunoassay techniques. RESULTS: The imprecision (CV) for measurement of estradiol [100-300 ng/L (367-1102 pmol/L)] was </=22% for most analytical techniques. Greater imprecision, as high as 40% for the same concentration range, was observed for the (AxSYM) MEIA method in the proficiency testing event of September 2001. Results from this method were bimodal in distribution. We found that unconjugated estriol at concentrations >1.5 microg/L (>5.2 nmol/L) interfered with the MEIA method, leading to decreased recovery of added estradiol by up to 50%. This suppression in estradiol measurement was prevented by dilution of the specimen before measurement. Addition of unconjugated estriol gave a positive bias in some other immunoassay methods for estradiol. Poor comparability among the immunoassay methods for measurement of estradiol at clinically relevant concentrations [ approximately 60 ng/L (220 pmol/L)] was revealed. CONCLUSIONS: A negative interference of unconjugated estriol with the MEIA method is a source of error for estradiol measurement. Lack of specificity and lack of comparability among immunoassay methods for estradiol may have detrimental effects on medical practice.
Clinical chemistry through Clinical Chemistry: a journal timeline.
The establishment of the modern discipline of clinical chemistry was concurrent with the foundation of the journal Clinical Chemistry and that of the American Association for Clinical Chemistry in the late 1940s and early 1950s. To mark the 50th volume of this Journal, I chronicle and highlight scientific milestones, and those within the discipline, as documented in the pages of Clinical Chemistry. Amazing progress has been made in the field of laboratory diagnostics over these five decades, in many cases paralleling-as well as being bolstered by-the rapid pace in the development of computer technologies. Specific areas of laboratory medicine particularly well represented in Clinical Chemistry include lipids, endocrinology, protein markers, quality of laboratory measurements, molecular diagnostics, and general advances in methodology and instrumentation.
Alanine aminotransferase apoenzyme in dogs.
Unusually low serum activity of alanine aminotransferase (ALT) was detected in a Rottweiler dog with gastric dilatation-volvulus. Activity of ALT in the same sample was found to be much higher (estimated increase of 14,225%) when measured by methods adding the cofactor pyridoxal-5'-phosphate (P5P), indicating that nearly all serum ALT was in the apoenzyme form. An investigation was undertaken to determine the frequency of high serum aminotransferase apoenzyme levels in dogs. Eighty canine serum samples submitted to the Clinical Pathology Laboratory at Cornell University were assayed for ALT and aspartate aminotransferase (AST) in the presence or absence of exogenous P5P. In 79 dogs, inclusion of P5P in the LAT assay resulted in a median decrease in AST activity of -6.3% (range -33.3% to 25.0%) in all 80 dogs. One dog had an increase of 336% in ALT activity after inclusion of P5P in the assay, but lacked a similar increase in AST activity. The reason for the high levels of ALT apoenzyme in the 2 dogs was not determined.