Intrathoracic impedance monitoring in patients with heart failure: correlation with fluid status and feasibility of early warning preceding hospitalization.

BACKGROUND: Patients with heart failure are frequently hospitalized for fluid overload. A reliable method for chronic monitoring of fluid status is therefore desirable. We evaluated an implantable system capable of measuring intrathoracic impedance to identify potential fluid overload before heart failure hospitalization and to determine the correlation between intrathoracic impedance and standard measures of fluid status during hospitalization. METHODS AND RESULTS: Thirty-three patients with NYHA class III and IV heart failure were implanted with a special pacemaker in the left pectoral region and a defibrillation lead in the right ventricle. Intrathoracic impedance was regularly measured and recorded between the lead and the pacemaker case. During hospitalizations, pulmonary capillary wedge pressure and fluid status were monitored. Ten patients were hospitalized for fluid overload 25 times over 20.7+/-8.4 months. Intrathoracic impedance decreased before each admission by an average of 12.3+/-5.3% (P<0.001) over an average of 18.3+/-10.1 days. Impedance reduction began 15.3+/-10.6 days (P<0.001) before the onset of worsening symptoms. There was an inverse correlation between intrathoracic impedance and pulmonary capillary wedge pressure (r=-0.61, P<0.001) and between intrathoracic impedance and net fluid loss (r=-0.70, P<0.001) during hospitalization. Automated detection of impedance decreases was 76.9% sensitive in detecting hospitalization for fluid overload, with 1.5 false-positive (threshold crossing without hospitalization) detections per patient-year of follow-up. CONCLUSIONS: Intrathoracic impedance is inversely correlated with pulmonary capillary wedge pressure and fluid balance and decreased before the onset of patient symptoms and before hospital admission for fluid overload. Regular monitoring of impedance may provide early warning of impending decompensation and diagnostic information for titration of medication.

Aged↗

Continuous autonomic assessment in patients with symptomatic heart failure: prognostic value of heart rate variability measured by an implanted cardiac resynchronization device.

BACKGROUND: Heart rate variability (HRV) as an indirect autonomic assessment provides prognostic information when measured over short time periods in patients with heart failure. Long-term continuous HRV can be measured from an implantable device, but the clinical value of these measurements is unknown. METHODS AND RESULTS: A total of 397 patients with New York Heart Association class III or IV heart failure were studied. Of these, 370 patients had information from their implanted cardiac resynchronization device for mortality risk stratification, and 288 patients had information for measured parameters (ie, HRV, night heart rate, and patient activity) and clinical event analyses. Continuous HRV was measured as the standard deviation of 5-minute median atrial-atrial intervals (SDAAM) sensed by the device. SDAAM <50 ms when averaged over 4 weeks was associated with increased mortality risk (hazard ratio 3.20, P=0.02) and SDAAM were persistently lower over the entire follow-up period in patients who required hospitalization or died. SDAAM decreased a median of 16 days before hospitalization and returned to baseline after treatment. Automated detection of decreases in SDAAM was 70% sensitive in detecting cardiovascular hospitalization, with 2.4 false-positives per patient-year of follow-up. CONCLUSIONS: This study demonstrates that SDAAM continuously measured from an implanted cardiac resynchronization device is lower in patients at high mortality and hospitalization risk. SDAAM declines as patient status decompensates. Continuous long-term SDAAM may be a useful tool in the clinical management of patients with chronic heart failure.

Aged↗

An adaptive interval-based algorithm for withholding ICD therapy during sinus tachycardia.

Avoiding inappropriate ICD therapy during supraventricular tachycardia (SVT) while assuring 100% sensitivity for VT/VF remains a challenge. Inappropriate VT/VF therapy during sinus tachycardia (ST) is particularly distressing to the patient because the full sequence of ICD therapies is often delivered. ST or 1:1 atrial tachycardia (AT) with long PR intervals and ST or AT with atrial oversensing of far-field R waves cause the majority of inappropriate therapy in the Medtronic GEM DR (Model 7271) ICD. The goals of the present effort were to define an adaptive interval-based algorithm for withholding VT/VF therapy in dual chamber ICDs during ST and to compare performance of the adaptive algorithm with that of the original ST withholding algorithm in the GEM DR. The adaptive algorithm uses a combination of 1:1 atrial to ventricular conduction pattern, changes in RR intervals and changes in intrinsic PR intervals to establish evidence for or against the presence of ST. Performances of the adaptive and original ST withholding algorithms were compared on 3 databases collected by implanted GEM DR devices. The first database included 684 spontaneous VT/VF episodes. The second database included 216 spontaneous SVT episodes that received inappropriate VT/VF therapy. These databases included up to 2,000 atrial or ventricular sensed or paced events preceding the spontaneous tachycardias. The third database included 320 spontaneous ST/AT episodes for which therapy was appropriately withheld by the GEM DR. Performance of the adaptive algorithm on the third database was predicted rather than directly computed because of record length limitations. VT/VF therapy was classified as "withheld" if evidence of ST remained high for one algorithm (i.e., at least 7 more beats to VT/VF detection) at the point of VT/VF detection by the other algorithm. For the 684 true VT/VF episodes, the original algorithm withheld VT/VF therapy in 5 episodes and the adaptive algorithm withheld VT/VF therapy in 3 episodes. The 95% confidence interval for the difference in VT/VF sensitivity between the adaptive and original algorithms was [-0.5 to + 1.1%]. Twelve of the 320 ST/AT episodes (3.8%) that were appropriately classified by the original algorithm were predicted to receive inappropriate therapy by the adaptive algorithm. However, relative to the original algorithm, the adaptive algorithm appropriately withheld VT/VF therapy for 76 of 216 true SVT episodes (i.e., incremental specificity of 35.2%). For the specific SVT episodes that were the targets for improvement by the adaptive ST algorithm (ST/AT with long PR intervals and ST/AT with intermittent atrial oversensing of far-field R waves), the adaptive algorithm reduced inappropriate therapy by 63.2%.

Algorithms↗

Comparison of electrocardiogram and intrathoracic electrogram signals for detection of ischemic ST segment changes during normal sinus and ventricular paced rhythms.

INTRODUCTION: The aim of this study was to compare surface ECGs with electrograms (EGM) that are available from implanted devices for the ability to detect ischemic ST segment changes during normal sinus (NS) and ventricular paced (VP) rhythms. METHODS AND RESULTS: ECG leads I, II, and V2, right atrial ring to left pectoral patch (representing the can of the device), right ventricular ring to left pectoral patch, and right atrial ring to right ventricular ring EGM were recorded continuously during percutaneous transluminal coronary angioplasty. One balloon inflation (> or = 60 sec) was analyzed from each of 22 NS and 22 VP subjects. The parameter AST was defined as the maximum absolute ST segment deviation (from isoelectric) during the first 60 seconds of inflation, measured relative to the baseline (preinflation) ST segment deviation. For EGM, a normalized deltaST was defined as the AST divided by the ratio of QRS amplitudes of EGM to ECG. During NS, the deltaST for EGM (0.43 mV) was significantly larger than that of ECG (0.09 mV, P = 0.0001) but the normalized deltaST for EGM (0.11 mV) was comparable to that of ECG (0.09 mV, P = 0.45). During VP, the AST for EGM (1.08 mV) was significantly larger than that of ECG (0.17 mV, P = 0.0001), but the normalized AST for EGM (0.11 mV) was significantly smaller than that of ECG (0.17 mV, P = 0.02). CONCLUSION: During both NS and VP, ischemic ST segment changes were significantly larger in EGM than in ECG. Much of this difference appears to be related to larger amplitudes of EGM signals. (J

Aged↗

Intrathoracic impedance to monitor heart failure status: a comparison of two methods in a chronic heart failure dog model.

In patients with heart failure (HF), a convenient and accurate assessment of HF status could enhance titration of medications and possibly reduce hospitalizations for fluid overload. This study examined the feasibility of monitoring HF status by measuring intrathoracic impedance with either an implantable cardioverter-defibrillator or a pacemaker. Six canines were each instrumented with four devices: two capable of measuring intrathoracic impedance between a right ventricular coil electrode and the device case, one custom pacemaker for inducing HF, and an implantable hemodynamic monitor to measure left ventricular end-diastolic pressure as an assessment of HF status. High-rate ventricular pacing for 3-7 weeks induced HF, followed by a 4-week recovery period. During high-rate pacing, left ventricular end-diastolic pressure was inversely correlated with impedance measurements from both systems (median r=-0.66; range r=-0.38 to -0.81). During recovery, the inverse correlation between left ventricular end-diastolic pressure and impedance was enhanced (median r=-0.88; range r=-0.58 to -0.95). The two types of impedance measurements were highly correlated (median r=-0.68 during pacing and r=-0.91 during recovery). These results suggest that various methods of measurement of intrathoracic impedance over time could be used to monitor HF status.

Animals↗