PubMed Health⌕ Search

Biomedical subjects

Roberto M Lang

Publications and source records attributed to Roberto M Lang.

At least 19 recordsLinked to original sources

Harmonic imaging for endocardial visualization and myocardial contrast echocardiography during transesophageal echocardiography.

BACKGROUND: Although harmonic imaging (HI) improves endocardial visualization and is necessary for myocardial perfusion imaging, it has yet to be implemented in transesophageal echocardiography. Our goal was to determine whether HI implemented in a prototype transesophageal echocardiography probe improved endocardial visualization and allowed perfusion imaging. METHODS: In 23 patients, fundamental and harmonic images were obtained in the transgastric short-axis (TSAX) and midesophageal 4-chamber views, and reviewed for endocardial visualization by 3 readers blinded to imaging mode. In 14 additional patients, perfusion imaging was performed in the TSAX view during contrast infusion. RESULTS: HI improved overall endocardial visualization, most noticeably in the anterior and lateral segments (P <.004) in the TSAX view, and in the lateral segments (P <.01) in the midesophageal 4-chamber view. The salvage rate was 8.3% in the TSAX view and 12.6% in the midesophageal 4-chamber view. Myocardial perfusion was consistently confirmed in the inferior (86%), posterior (100%), and lateral (79%) segments, but rarely in the septal (21%), anteroseptal (0%), and anterior (14%) segments. CONCLUSION: Use of HI with transesophageal echocardiography improves endorcardial visualization and allows partial assessment of myocardial perfusion.

Coronary Circulation↗

Secondary coronary artery vasospasm promotes cardiomyopathy progression.

Genetic defects in the plasma membrane-associated sarcoglycan complex produce cardiomyopathy characterized by focal degeneration. The infarct-like pattern of cardiac degeneration has led to the hypothesis that coronary artery vasospasm underlies cardiomyopathy in this disorder. We evaluated the coronary vasculature of gamma-sarcoglycan mutant mice and found microvascular filling defects consistent with arterial vasospasm. However, the vascular smooth muscle sarcoglycan complex was intact in the coronary arteries of gamma-sarcoglycan hearts with perturbation of the sarcoglycan complex only within the adjacent myocytes. Thus, in this model, coronary artery vasospasm derives from a vascular smooth muscle-cell extrinsic process. To reduce this secondary vasospasm, we treated gamma-sarcoglycan-deficient mice with the calcium channel antagonist verapamil. Verapamil treatment eliminated evidence of vasospasm and ameliorated histological and functional evidence of cardiomyopathic progression. Echocardiography of verapamil-treated, gamma-sarcoglycan-null mice showed an improvement in left ventricular fractional shortening (44.3 +/- 13.3% treated versus 37.4 +/- 15.3% untreated), maximal velocity at the aortic outflow tract (114.9 +/- 27.9 cm/second versus 92.8 +/- 22.7 cm/second), and cardiac index (1.06 +/- 0.30 ml/minute/g versus 0.67 +/- 0.16 ml/minute/g, P < 0.05). These data indicate that secondary vasospasm contributes to the development of cardiomyopathy and is an important therapeutic target to limit cardiomyopathy progression.

Animals↗

Atypical cardiac myxomas.

Atypical cardiac myxomas are a rare occurrence and may present with a variety of clinical manifestations depending on the morphology and location. We present three cases of myxomas located atypically on the left atrial appendage ridge, chordae of the mitral valve, and right atrium. Echocardiography plays a prominent role in the diagnosis and follow-up of these patients.

Adult↗

Thyroid hormone resistance in the heart: role of the thyroid hormone receptor beta isoform.

Several cardiac genes possess thyroid hormone (TH) response elements regulated by TH receptors. Mutation in TR-beta gene causes the human syndrome of resistance to TH, which is characterized by elevated serum concentration of T(4) and T(3) and variable degrees of insensitivity to TH. It is unclear, however, whether a mutant TR-beta could function as a dominant negative in the heart when expressed from the endogenous locus. A well-described resistance to TH (Delta337T) was either introduced into germline of mice (KI-mut) or expressed as a transgene in the heart using a cardiac-specific promoter (KS-mut). Mice were studied at baseline, after 5-propyl-2-thiouracil (PTU) or after PTU and T(3) treatment (PTU + T(3)). PTU + T(3) treatment significantly increased left ventricular mass in all groups compared with baseline measurements, although the increase in left ventricular mass was significantly less in KI-mut animals. Baseline heart rates (HRs) were similar in wild-type (WT) and KI-mut but were lower in KS-mut animals. After TH deprivation (PTU), HR decreased in WT and KI-mut animals; similarly, HR increased in WT and KI-mut after PTU + T(3). In contrast, HR in KS-mut animals did not change after either treatment. Except for cardiac hypertrophy, the presence of a germline TR-beta mutation had surprisingly little effect on cardiac function.

Animals↗

Use of echocardiography for the phenotypic assessment of genetically altered mice.

Transgenic mice displaying abnormalities in cardiac development and function represent a powerful new tool for understanding molecular mechanisms underlying normal cardiovascular function and the pathophysiological bases of human cardiovascular disease. Complete cardiac evaluation of phenotypic changes in mice requires the ability to noninvasively assess cardiovascular structure and function in a serial manner. However, the small mouse heart beating at rates in excess of 500 beats/min presents unique methodological challenges. Two-dimensional and Doppler echocardiography have been recently used as effective, noninvasive tools for murine imaging, because quality images of cardiac structures and valvular flows can be obtained with newer high-frequency transthoracic transducers. We will discuss the use of echocardiography for the assessment of 1) left ventricular (LV) chamber dimensions and wall thicknesses, 2) LV mass, 3) improved endocardial border delineation using contrast echocardiography, 4) LV contractility using ejection phase indices and load-independent indices, 5) vascular properties, and 6) LV diastolic performance. Evaluation of cardiovascular performance in closed chest mice is feasible in a variety of murine models using Doppler echocardiographic imaging.

Animals↗

Percutaneous closure of a ruptured sinus of Valsalva aneurysm using the Amplatzer Duct Occluder.

Sinus of Valsalva aneurysms are rare congenital anomalies. When they rupture, they can lead to the development of biventricular failure as a result of systemic-pulmonary shunting. Surgical repair has been the traditional treatment for these aneurysms. We present a case of a 54 year old man in whom a ruptured sinus of Valsalva aneurysm was successfully closed using a catheter-based approach with the Amplatzer Duct Occluder.

Aortic Aneurysm↗

Unsuspected clinically important findings detected with a small portable ultrasound device in patients admitted to a general medicine service.

OBJECTIVE: We sought to determine whether physicians with training in echocardiography could successfully use a small echocardiographic device to detect occult cardiovascular disease in patients admitted to a general medical service. METHODS: In all, 103 consecutive patients had a physician-performed bedside echocardiographic examination with a small portable ultrasound device. RESULTS: Of patients, 70% did not have a clinical indication for echocardiography and of these patients, 39% had an abnormal study with the portable ultrasound device. There was a high rate of false-positive examinations, but approximately 17% of patients without a clinical indication for echocardiography had an important cardiac abnormality detected, including 10% with unsuspected left ventricular systolic dysfunction. CONCLUSIONS: Many patients on a general medical hospital ward have unsuspected, clinically important cardiac findings such as left ventricular dysfunction that can be screened for by physicians with training in echocardiography using small portable ultrasound devices.

Academic Medical Centers↗

Biplane stress echocardiography using a prototype matrix-array transducer.

BACKGROUND: Rapid image acquisition after cessation of exercise is essential for accurate stress echocardiography. Recently, a prototype matrix-array transducer has been developed that allows simultaneous acquisition of 2 imaging planes (biplane [BP] imaging). METHODS: In all, 19 healthy volunteers underwent 2 separate stress echocardiographic studies. Images were acquired in traditional 2-dimensional or BP format pre-exercise and postexercise. RESULTS: Total image acquisition time for 2-dimensional stress echocardiography was 38 +/- 8 seconds versus 29 +/- 8 seconds for BP imaging (P <.05). Heart rates were acquired closer to age-predicted maximum with BP imaging in the apical 3- and 2-chamber and parasternal long- and short-axis views (82%, 75%, 70%, 70% for BP vs 76%, 72%, 68%, 66% for 2-dimensional, respectively). CONCLUSION: BP imaging using a recently developed matrix-array probe allows more rapid imaging postexercise, resulting in acquisition of poststress images at higher heart rates without compromising image quality.

Acoustics↗

Dynamic three-dimensional color flow Doppler: an improved technique for the assessment of mitral regurgitation.

BACKGROUND: Prior studies have reconstructed mitral regurgitant flow in three dimensions displaying gray scale renditions of the jets, which were difficult to differentiate from surrounding cardiac structures. Recently, a color-coded display of three-dimensional (3D) regurgitant flow has been developed. However, this display was unable to integrate cardiac anatomy, thereby losing spatial information, which made it difficult to determine the jet origin and its spatial trajectory. To overcome this limitation, an improved method of 3D color reconstruction of regurgitant jets obtained from color flow Doppler using a transesophageal approach was developed to allow the combined display of both color flow and gray scale information. OBJECTIVES: To demonstrate the feasibility of 3D reconstruction of regurgitant mitral flow jets using an improved method of color encoding digital data acquired by transesophageal echocardiography (TEE). METHODS: We studied 46 patients undergoing a clinically indicated TEE study. All subjects had mitral regurgitation detected on a previous transthoracic study. Atrial fibrillation or poor image quality were not used as exclusion criteria. The 3D study was performed using a commercial ultrasound imaging system with a TEE probe (Sonos 5500, Agilent Technologies). A rotational mode of acquisition was used to collect two-dimensional (2D) color flow images at 3-degree intervals over 180 degrees. Images were processed off line using the Echo-View Software (TomTec Imaging Systems). Volume-rendered 3D color flow jets were displayed along with gray scale information of the adjacent cardiac structures. RESULTS: Mitral regurgitant flow, displayed in left atrial and two longitudinal orientations, was successfully reconstructed in all patients. The time for acquisition, post-processing, and rendering ranged between 10 and 15 minutes. There were 28 centrally directed jets and 15 eccentric lesions. Eight patients in the study had periprosthetic mitral regurgitant flow. CONCLUSIONS: Three-dimensional imaging of mitral regurgitant jets is feasible in the majority of patients. This improved technique provides additional information to that obtained from the 2D examination. Particularly, in patients with paravalvular leaks 3D color flow Doppler provides information on the origin and the extent of the dehiscence, as well as insight into the jet direction. In addition, in patients with eccentric mitral regurgitation, this new modality overcomes the inherent limitations of 2D echo Doppler by depicting the full extent of the jet trajectory.

Echocardiography, Doppler, Color↗

The hand-carried echocardiographic device as an aid to the physical examination.

Physical examination skills have been declining over the past several decades while technology has made diagnostic testing increasingly sophisticated. For patients with cardiovascular disease, the best approach to bedside diagnosis would be one that combines both physical examination and ready access to technology at the time of the patient encounter. Most cardiac testing is not performed at the bedside due to equipment size and time limitations for these tests. Small hand-carried echocardiographic devices are now available for rapid bedside examination. These devices compare well to full-featured systems when used in cardiology outpatient settings and in hospitalized patients who are not critically ill. Compared with physical examination by board certified cardiologists, these devices decrease diagnostic error. Early use of hand-carried echocardiographic devices after physical examination has been demonstrated to impact patient triage and treatment as well as uncover otherwise undetected cardiac disease. The degree of training required for responsible use of these devices is as yet unclear. However, organized training sessions have resulted in modest agreement with standard echocardiography and point-of-care echocardiography performed by expert echocardiographers. It is conceivable that the hand-carried echocardiographic devices will be used in medical school curriculum to enhance medical student education in the future.

Echocardiography↗

Real-time three-dimensional echocardiography using a novel matrix array transducer.

Three-dimensional echocardiography has multiple advantages over two-dimensional echocardiography, such as accurate left ventricular quantification and improved spatial relationships. However, clinical use of three-dimensional echocardiography has been impeded by tedious and time-consuming methods for data acquisition and post-processing. A newly developed matrix array probe, which allows real-time three-dimensional imaging with instantaneous on-line volume-rendered reconstruction, direct manipulation of thresholding, and cut planes on the ultrasound unit may overcome the aforementioned limitations. This report will review current methods of three-dimensional data acquisition, emphasizing the real-time methods and clinical applications of the new matrix array probe.

Echocardiography, Three-Dimensional↗

Use of contrast enhancement for the assessment of left ventricular function.

Endocardial visualization is essential for accurate interpretation of regional wall thickening abnormalities, which constitute the diagnostic hallmark of coronary artery disease, and for reproducible assessment of left ventricular (LV) ejection fraction. Unfortunately, in many cardiac patients, poor image quality does not allow consistent visualization, let alone automated detection, of the endocardial boundary in all segments throughout the cardiac cycle. Continuing efforts directed towards improving endocardial visualization made by both echocardiographic imaging equipment manufacturers and researchers have recently produced new objective, quantitative approaches for the assessment of global and regional LV function. Although these developments have not been integrated into routine clinical practice, they may have a positive impact on endocardial visualization and, thus, eventually improve the ability to accurately and objectively evaluate LV performance. In this review, we discuss some of the latest developments in the use of contrast for the evaluation of LV function.

Animals↗

Interpretation of left ventricular wall motion during stress testing.

This article describes the obstacles to stress echocardiographic interpretation, and reviews the techniques currently available that offer a more objective approach to stress wall motion analysis than the conventional visual methodology. These techniques include Doppler-based methods, such as myocardial Doppler velocity and strain rate imaging, as well as automated border detection techniques, such as acoustic quantification and color kinesis.

Contrast Media↗

Assessment of global and regional left ventricular diastolic function in hypertensive heart disease using automated border detection techniques.

Acoustic quantification (AQ) and color kinesis (CK) are techniques that involve automated detection and tracking of endocardial borders. These methods are useful for the evaluation of global and regional left ventricular (LV) systolic function and more recently have been applied to evaluating LV diastolic performance. Assessment of diastolic dysfunction in hypertensive heart disease is a relevant clinical issue in which these techniques have proven useful. The diastolic portion of left atrium and LV AQ area waveforms are frequently abnormal in patients with left ventricular hypertrophy (LVH). Left ventricular AQ curves consistently demonstrate reduced rapid filling fraction (RFF) and peak rapid filling rate (PRFR), elevated atrial filling fraction (AFF), peak atrial filling rate (PAFR), and reductions in the ratio PRFR/PAFR. Acoustic quantification complements traditional Doppler echocardiographic evaluation of global diastolic function. Many patients with significant LVH and normal Doppler diastolic parameters can be identified as having diastolic dysfunction with AQ. In addition, CK has allowed the evaluation of regional diastolic performance in hypertensive patients. Regional filling curves obtained from CK have demonstrated that endocardial diastolic motion is commonly delayed and heterogeneous in patients with LVH.

Diastole↗

Accuracy of mitral valve area measurements using transthoracic rapid freehand 3-dimensional scanning: comparison with noninvasive and invasive methods.

OBJECTIVE: The feasibility and accuracy of direct transthoracic 3-dimensional (3D) mitral valve area (MVA) measurements obtained using freehand scanning was investigated in patients with mitral stenosis. METHODS: A total of 30 patients (26 women, 4 men; aged 55 +/- 13 years) underwent a 2-dimensional (2D) and Doppler study 1 hour before percutaneous balloon mitral valvuloplasty. Transthoracic freehand data were acquired using a magnetic receiver attached to a broadband transducer, gated to electrocardiography and respiration. Volumetric MVA measurements from the left ventricle and left atrium were obtained and compared with MVA measurements derived from 2D planimetry, pressure half-time, and proximal isovelocity surface area. Invasive Gorlin MVA measurements were the gold standard for comparison. RESULTS: In all, 29 patients (97%) had 3D data allowing MVA measurements. Direct 3D measurements from the left ventricle had the least bias (0.06 +/- 0.19 cm(2)) and tightest limits of agreement (-0.44 to 0.32) compared with left atrium measurements (0.17 +/- 0.25 cm(2) and -0.67 to 0.33, respectively). The proximal isovelocity surface area method (bias: 0.09 +/- 0.34 cm(2)) was the most accurate of all 2D methods followed by pressure half-time (0.17 +/- 0.36 cm(2)) and planimetry (0.21 +/- 0.29 cm(2)). CONCLUSION: Direct 3D MVA measurements from the left ventricle using transthoracic freehand scanning are more accurate than traditional 2D methods.

Adult↗