PubMed Health⌕ Search

Biomedical subjects

Roberto Zaldivar

Publications and source records attributed to Roberto Zaldivar.

2 recordsLinked to original sources

Bioptics in phakic and pseudophakic intraocular lens with the Nidek EC-5000 excimer laser.

PURPOSE: To evaluate predictability, safety, stability, and complications related to bioptics in patients that received phakic and those that received pseudophakic intraocular lenses. Both groups had LASIK with the Nidek EC-5000 excimer laser following IOL implantation. METHODS: We evaluated retrospectively 281 eyes of 196 patients with posterior chamber phakic implantation (ICL) and 64 pseudophakic eyes of 55 patients. All patients had LASIK 1 month or more after the first surgery. We used a treatment zone of 5.5 mm with a 7.00-mm transition zone. The flap was made with the Automated Corneal Shaper (ACS). RESULTS: In the group of phakic ICL eyes with bioptics, preoperative mean spherical equivalent refraction was -5.50 D (range, -1.37 to -16.00 D). The first day after LASIK, mean spherical equivalent refraction was -0.06 D, and at 1 month, -0.40 D. In pseudophakic bioptics eyes, preoperative mean spherical equivalent refraction was -2.61 D (range, +0.50 to -5.50 D). The first day after LASIK it was +0.27 D, and 1 month after LASIK it was +0.09 D. The incidence of complications was similar in both groups of patients. The most frequent complication was keratitis sicca (approximately 10% in each group). Interstitial edema (2.1%) was present only in phakic bioptics eyes. No retinal complications were observed. Refraction was stable 4 years after surgery. Target achieved refraction was +/- 0.50 D, showing the predictability of the procedure. CONCLUSIONS: Predictability and safety were demonstrated according to results and absence of severe complications related with this technique. Older patients did not develop more complications than younger people; dry eye incidence was similar in both groups. In extreme myopia patients did not present retinal complications related to surgical procedures.

Adult↗

Five techniques for improving outcomes of hyperopic LASIK.

PURPOSE: To determine whether five changes to our hyperopic LASIK protocol produced better outcomes. METHODS: Five changes, both technical and surgical, were instituted for the treatment of hyperopia. These five changes were nomogram refinements accounting for accommodation, use of a 7.0-mm optical zone and a 9.5-mm transition zone, a targeted mean flap diameter of 10.5 mm, sequential interruption of the laser ablation, and cleaning of the interface. The study comprised 43 eyes undergoing LASIK for hyperopia or hyperopic astigmatism with a mean preoperative spherical equivalent refraction of +2.28 diopters (D), a mean sphere of +1.93 D (range: +4.25 to +0.25 D), and mean cylinder of +1.10 D (range: +4.50 to +0.25 D). The NIDEK CXII excimer laser was used for all treatments. RESULTS: From 1 day to 3 months postoperatively, the mean hyperopic shift was <0.50 D. Postoperatively, the number of patients achieving a distance best spectacle-corrected visual acuity (BSCVA) of 20/20 gradually increased to 93% by 3 months. The number of eyes that achieved 20/15 increased by 11.7% compared to preoperatively. Eighty-eight percent of eyes maintained or gained lines of BSCVA. Four patients lost 1 line of BSCVA. One patient lost >1 line of vision due to visually significant microstriae. CONCLUSIONS: The outcomes support the observation that five surgical and technical modifications to the hyperopic LASIK procedure result in excellent visual quality and refractive outcomes and a low rate of regression.

Adult↗