PubMed Health⌕ Search

Biomedical subjects

Robin L McCarley

Publications and source records attributed to Robin L McCarley.

18 recordsLinked to original sources

Electrochemical detection of glutathione using redox indicators.

The nucleophilic addition of the aminothiols homocysteine (HCY), cysteine (CYS), and glutathione (GSH) to the electrogenerated quinone of fluorone black (1) via the ECE mechanism is reported. It is demonstrated that 1selectively reacts with GSH to form the bis-GSH adduct, 1-(GSH)(2), while only the monothiol adducts were generated in the presence of HCY and CYS (1-HCY and 1-CYS, respectively). The more anodic E(pa) of 1-(GSH)2 relative to 1 and 1-GSH (DeltaE(pa) approximately +0.14) is the voltammetric signature that allows the discrimination of GSH from HCY and CYS. It is also shown that the presence of structurally similar aminothiols-HCY and CYS-posed no interference to the signature voltammetric response of 1-(GSH)2.

Electrochemistry↗

Designing highly specific biosensing surfaces using aptamer monolayers on gold.

To build highly specific surfaces using aptamer affinity reagents, the effects of linker and coadsorbents were investigated for maximizing target binding and specificity for aptamer-based self-assembled monolayers (SAMs) supported on gold. An aptamer that binds the protein thrombin was utilized as a model system to compare different mixed monolayer systems toward maximizing binding and selectivity to the immobilized aptamer. Important factors used to optimize binding characteristics of thrombin to the aptamer-based monolayer films include changes in design elements of the linker and different coadsorbent thiols. Binding events measured by surface plasmon resonance (SPR) and ellipsometry showed that the binding performance of the aptamer SAMs depends principally on the linker and to a lesser extent on the coadsorbent. SAMs formed with HS-(CH2)6-OP(O)2O-(CH2CH2O)6-TTTTT-aptamer exhibited a 4-fold increase in binding capacity versus SAMs made using HS-(CH2)6-TTTTT-aptamer. Furthermore, SAMs made using HS-(CH2)6-OP(O)2O-(CH2CH2O)6-TTTTT-aptamer showed nearly complete specificity for thrombin versus bovine serum albumin (BSA, less than 2% bound), while a SAM incorporating a random DNA fragment (HS-(CH2)6-OP(O)2O-(CH2CH2O)6-TTTTT-RANDOM) showed little binding of thrombin. Irrespective of the aptamer-linker system, use of HS-(CH2)11(OCH2CH2)3OH, referred to as EG(3), as a coadsorbent enhanced binding of thrombin by approximately 2.5-fold compared to that of HS-(CH2)6-OH (mercaptohexanol, MCH).

Aptamers, Nucleotide↗

Purification and preconcentration of genomic DNA from whole cell lysates using photoactivated polycarbonate (PPC) microfluidic chips.

We discuss the use of a photoactivated polycarbonate (PPC) microfluidic chip for the solid-phase, reversible immobilization (SPRI) and purification of genomic DNA (gDNA) from whole cell lysates. The surface of polycarbonate was activated by UV radiation resulting in a photo-oxidation reaction, which produced a channel surface containing carboxylate groups. The gDNA was selectively captured on this photoactivated surface in an immobilization buffer, which consisted of 3% polyethylene glycol, 0.4 M NaCl and 70% ethanol. The methodology reported herein is similar to conventional SPRI in that surface-confined carboxylate groups are used for the selective immobilization of DNA; however, no magnetic beads or a magnetic field are required. As observed by UV spectroscopy, a load of approximately 7.6 +/- 1.6 microg/ml of gDNA was immobilized onto the PPC bed. The recovery of DNA following purification was estimated to be 85 +/- 5%. The immobilization and purification assay using this PPC microchip could be performed within approximately 25 min as follows: (i) DNA immobilization approximately 6 min, (ii) chip washout with ethanol 10 min, and (iii) drying and gDNA desorption approximately 6 min. The PPC microchip could also be used for subsequent assays with no substantial loss in recovery, no observable carryover and no need for 'reactivation' of the PC surface with UV light.

Buffers↗

Stoichiometric inhibition of amyloid beta-protein aggregation with peptides containing alternating alpha,alpha-disubstituted amino acids.

We have prepared two peptides based on the hydrophobic core (Lys-Leu-Val-Phe-Phe) of amyloid beta-protein (Abeta) that contain alpha,alpha-disubstituted amino acids at alternating positions, but differ in the positioning of the oligolysine chain (AMY-1, C-terminus; AMY-2, N-terminus). We have studied the effects of AMY-1 and AMY-2 on the aggregation of Abeta and find that, at stoichiometric concentrations, both peptides completely stop Abeta fibril growth. Equimolar mixtures of AMY-1 and Abeta form only globular aggregates as imaged by scanning force microscopy and transmission electron microscopy. These samples show no signs of protofibrillar or fibrillar material even after prolonged periods of time (4.5 months). Also, 10 mol % of AMY-1 prevents Abeta self-assembly for long periods of time; aged samples (4.5 months) show only a few protofibrillar or fibrillar aggregates. Circular dichroism spectroscopy of equimolar mixtures of AMY-1 and Abeta show that the secondary structure of the mixture changes over time and progresses to a predominantly beta-sheet structure, which is consistent with the design of these inhibitors preferring a sheet-like conformation. Changing the position of the charged tail on the peptide, AMY-2 interacts with Abeta differently in that equimolar mixtures form large ( approximately 1 mum) globular aggregates which do not progress to fibrils, but precipitate out of solution. The differences in the aggregation mediated by the two peptides is discussed in terms of a model where the inhibitors act as cosurfactants that interfere with the native ability of Abeta to self-assemble by disrupting hydrophobic interactions either at the C-terminus or N-terminus of Abeta.

Amino Acids↗

Fabrication of DNA microarrays onto polymer substrates using UV modification protocols with integration into microfluidic platforms for the sensing of low-abundant DNA point mutations.

We describe the microfabrication and operational characteristics of a simple flow-through biochip sensor capable of detecting low abundant point mutations in K-ras oncogenes from genomic DNA, which carry high diagnostic value for colorectal cancers. The biochip consisted of an allele-specific ligase detection reaction (LDR) coupled to a universal array for interrogating multiple mutations simultaneously from a clinical sample. The integrated sensing platform was micro-manufactured from two different polymers, polycarbonate, PC, which was used for the LDRs, and poly(methyl methacrylate), PMMA, which was used to build the microarray. Passive elements were hot embossed into the PC and PMMA microchips and then, the chips assembled into a three-dimensional architecture with the interconnect fabricated from an elastomer, poly(dimethylsiloxane), PDMS, to produce a leak-free connection between the biochips. The array in PMMA was produced using a photomodification process, which involved three steps; (1) UV (254 nm) exposure of the polymer surface; (2) EDC coupling of amine-terminated oligonucleotide probes to the surface (via an amide bond) and; (3) washing of the surface. The LDR/hybridization flow-through biochip performed the entire assay at a relatively fast processing speed: 6.5 min for on-chip LDR, 10 min for washing, and 2.6 min for fluorescence scanning (total processing time=19.1 min) and could screen multiple mutations simultaneously for high throughput applications at a level of one mutant sequence in 100 wild-type sequences.

Biosensing Techniques↗

Photochemically patterned poly(methyl methacrylate) surfaces used in the fabrication of microanalytical devices.

We report here the photochemical surface modification of poly(methyl methacrylate), PMMA, microfluidic devices by UV light to yield pendant carboxylic acid surface moieties. Patterns of carboxylic acid sites can be formed from the micrometer to millimeter scale by exposure of PMMA through a contact mask, and the chemical patterns allow for further functionalization of PMMA microdevice surfaces to yield arrays or other structured architectures. Demonstrated here is the relationship between UV exposure time and PMMA surface wettability, topography, surface functional group density, and electroosmotic flow (EOF) of aqueous buffer solutions in microchannels made of PMMA. It is found that the water contact angle on PMMA surfaces decreases from 70 degrees to 24 degrees after exposure to UV light as the result of the formation of carboxylic acid sites. However, upon rinsing with 2-propanol, the water contact angle increases to approximately 80 degrees , and this increase is attributed to changes in surface roughness resulting from removal of low molecular weight PMMA formed from scission events. In addition, the surface roughness and surface coverage of carboxylic acid groups exhibit a characteristic trend with UV exposure time. Electroosmotic flow (EOF) in PMMA microchannels increases upon UV modification and is pH dependent. The possible photolysis mechanism for formation of carboxylic acid groups on PMMA surfaces under the conditions outlined in this work is discussed.

Carboxylic Acids↗

Surface-induced aggregation of beta amyloid peptide by co-substituted alkanethiol monolayers supported on gold.

The primary pathological characteristic of Alzheimer's disease is the presence in the brain of self-assembled beta amyloid (Abeta) protein fibrils, consisting of 35-43 amino acid residues. The toxicity of the aggregated protein structures has previously been proposed to be related to the interaction of Abeta fibrils with neuronal membranes (phospholipid bilayers). Here, surfaces consisting of self-assembled alkanethiol monolayers with different end groups--supported on Au--are used to test the effect of surface chemistry on the structure and morphology of aggregates formed from an active fragment (Abeta10-35) of the Abeta peptide. The influence of monolayer nature (end group) on the aggregation of Abeta10-35 was examined using reflection-absorption infrared spectroscopy (RAIRS) and scanning force microscopy (SFM). Evaluation of the SFM and RAIRS data reveals the presence of Abeta10-35 protein on the various monolayer surfaces, with the surface protein possessing predominantly beta-sheet and random-coil conformations. Time-dependent studies of the extent of Abeta10-35 aggregation and deposition on the various surfaces and the effect of the monolayers on seeding of Abeta10-35 aggregates in solution are also discussed.

Alkanes↗

Fabrication of DNA microarrays onto poly(methyl methacrylate) with ultraviolet patterning and microfluidics for the detection of low-abundant point mutations.

We have developed a simple ultraviolet (UV)-photomodification protocol using poly(methyl methacrylate) and polycarbonate to produce functional scaffolds consisting of carboxylic groups that allow covalent attachment of amine-terminated oligonucleotide probes to these surface groups through carbodiimide coupling. Use of the photomodification procedure coupled to microfluidics allowed for the rapid generation of medium-density DNA microarrays. The method reported herein involves the use of poly(dimethylsiloxane) microchannels reversibly sealed to photomodified poly(methyl methacrylate) surfaces to serve as stencils for patterning the oligonucleotide probes. After array construction, the poly(dimethylsiloxane) stencil is rotated 90 degrees to allow interrogation of the array using microfluidics. The photomodification process for array fabrication involves only three steps: (1) broadband UV exposure of the polymer surface, (2) carbodiimide coupling of amine-terminated oligonucleotide probes to the surface (via an amide bond), and (3) washing of the surface. The density of probes attached to this activated surface was found to be approximately 41pmolcm(-2), near the steric-saturation limit for short oligonucleotide probes. We demonstrate the use of this procedure for screening multiple KRAS2 mutations possessing high diagnostic value for colorectal cancers. A ligase detection reaction/universal array assay was carried out using parallel detection of two different low-abundant DNA point mutations in KRAS2 oncogenes with the allelic composition evaluated at one locus. Four zip code probes immobilized onto the poly(methyl methacrylate) surface directed allele-specific ligation products containing mutations in the KRAS2 gene (12.2D, 12.2A, 12.2V, and 13.4D) to the appropriate address of a universal array with minimal amounts of cross-hybridization or misligation.

Adsorption↗

Positive dendritic effects on the electron-donating potencies of poly(propylene imine) dendrimers.

[structure: see text] Two series of poly(propylene imine), PPI, dendrimers terminated with a redox-active donor, 4-dimethylaminobenzyl (4-DMAB), including their respective nondendronized model compounds, are reported. In these two series, a positive dendritic effect was observed for the formation of charge-transfer (CT) complexes between the dendrimers and 7,7,8,8-tetracyanoquinodimethane (TCNQ). However, the nondendronized compounds did not form CT complexes with TCNQ, even though their redox potentials are similar to those of the 4-DMAB units attached to the dendrimers.

Journal Article↗

Resist-free patterning of surface architectures in polymer-based microanalytical devices.

The ability to form patterns of chemically reactive surface functionalities in microanalytical devices using a simple photopatterning approach without the need for photoresist-based methods is described. Direct UV exposure of the surfaces of poly(methyl methacrylate), PMMA, and poly(carbonate), PC, microfluidic devices through optical masks leads to the production of patterns of near monolayer quantities of surface carboxylic acid groups as determined by surface coverage, X-ray photoelectron spectroscopy, and fluorescence microscopy experiments. Formation of the reactive carboxylic acid groups without significant physical (topographical) damage to the polymer device substrates is achieved by use of low UV fluence and exposure times. Modification of the patterned, surface carboxylic acid groups with metals, thermally responsive polymers, and antibodies results in microfluidic devices possessing metallic interconnects and detection electrodes and the ability to capture intact biological cells and proteins from solution.

Methylmethacrylates↗

Cell transport via electromigration in polymer-based microfluidic devices.

Electrokinetic transport of Escherichia coli and Saccharomyces cerevisiae (baker's yeast) cells was evaluated in microfluidic devices fabricated in pristine and UV-modified poly(methyl methacrylate)(PMMA) and polycarbonate (PC). Chip-to-chip reproducibility of the cell's apparent mobilities (micro(app)) varied slightly with a RSD of approximately 10%. The highest micro(app) for baker's yeast cells was observed in UV-modified PC with 0.5 mM PBS (pH = 7.4), and the lowest was measured in pristine PMMA with 20 mM PBS (pH = 7.4). Baker's yeast in all devices migrated toward the cathode because of their smaller electrophoretic mobility compared to the EOF. In 0.5 mM and 1 mM PBS, E. coli cells migrated toward the anode in all cases, opposite to the direction of the EOF due to their larger electrophoretic mobility. E. coli cells in 20 mM PBS migrated toward the cathode, which indicated that the electrophoretic mobility of E. coli cells decreased at higher ionic strengths. Observed differential migrations of E. coli and baker's yeast cells in appropriately prepared polymer microchips were used as the basis for selective introduction into microfluidic devices of only one type of cell. As a working model, experiments were performed with E. coli and RBCs (red blood cells). RBCs migrated toward the cathode in pristine PMMA with 1 mM and 20 mM PBS (pH = 7.4), opposite to the direction of the E. coli cells. By judicious choice of the buffer concentration in which the cell suspension was prepared and the polymer material, RBCs or E. coli cells were selectively introduced into the microdevice, which was monitored via laser backscatter signals.

Cells↗

Solid-phase reversible immobilization in microfluidic chips for the purification of dye-labeled DNA sequencing fragments.

In this manuscript, we discuss the use of photoactivated polycarbonate (PC) for purification of dye-labeled terminator sequencing fragments using solid-phase reversible immobilization (SPRI) prior to gel electrophoretic sorting of these DNAs. An immobilization bed for the DNA purification was produced by exposing a posted microchannel to UV radiation, which induced a surface photooxidation reaction, resulting in the production of carboxylate groups. The immobilization microchannel contained microposts to increase the loading level of DNAs to improve signal intensity without the need for preconcentration. By suspending the sequencing cocktail in an immobilization buffer (TEG/ethanol), the DNA fragments demonstrated a high affinity for this carboxylated surface. The loading density of DNAs to this activated surface was found to be 3.9 pmol cm(-2). The captured DNA could be subsequently released from the surface by incubation with ddH2O. SPRI cleanup of dye-terminator sequencing fragments using the photoactivated PC chip and slab gel electrophoresis produced a read length comparable to the conventional SPRI format, which utilized carboxylated magnetic beads and a magnetic field. The read length for the PC-SPRI format was found to be 620 bases with a calling accuracy of 98.9%. The PC-SPRI cleanup format was also integrated to a capillary gel electrophoresis (CGE) system. The PC-SPRI method was shown to effectively remove excess dye terminator from the CGE tract, but yielded lower plate numbers, as compared to a direct injection method with purification accomplished off-chip. The loss in efficiency was found to result primarily from the extended injection time associated with the microchip purification method.

Base Sequence↗

Microarrays assembled in microfluidic chips fabricated from poly(methyl methacrylate) for the detection of low-abundant DNA mutations.

Low-density arrays were assembled into microfluidic channels hot-embossed in poly(methyl methacrylate) (PMMA) to allow the detection of low-abundant mutations in gene fragments (K-ras) that carry point mutations with high diagnostic value for colorectal cancers. Following spotting, the chip was assembled with a cover plate and the array accessed using microfluidics in order to enhance the kinetics associated with hybridization. The array was configured with zip code sequences (24-mers) that were complementary to sequences present on the target. The hybridization targets were generated using an allele-specific ligase detection reaction (LDR), in which two primers (discriminating primer that carriers the complement base to the mutation being interrogated and a common primer) that flank the point mutation and were ligated joined together) only when the particular mutation was present in the genomic DNA. The discriminating primer contained on its 5'-end the zip code complement (directs the LDR product to the appropriate site of the array), and the common primer carried on its 3' end a fluorescent dye (near-IR dye IRD-800). The coupling chemistry (5'-amine-containing oligonucleotide tethered to PMMA surface) was optimized to maximize the loading level of the zip code oligonucleotide, improve hybridization sensitivity (detection of low-abundant mutant DNAs in high copy numbers of normal sequences), and increase the stability of the linkage chemistry to permit re-interrogation of the array. It was found that microfluidic addressing of the array reduced the hybridization time from 3 h for a conventional array to less than 1 min. In addition, the coupling chemistry allowed reuse of the array > 12 times before noticing significant loss of hybridization signal. The array was used to detect a point mutation in a K-ras oncogene at a level of 1 mutant DNA in 10,000 wild-type sequences.

DNA↗

Contact conductivity detection in poly(methyl methacrylate)-based microfluidic devices for analysis of mono- and polyanionic molecules.

An on-column contact conductivity detector was developed for the analysis of various mono- and polyanionic compounds separated by electrophoresis chips fabricated in poly(methyl methacrylate) (PMMA) using hot embossing techniques from Ni electroforms. The detector consisted of a pair of Pt wires (127 microm diameter) with an end-to-end spacing of approximately 20 microm and situated within the fluidic channel. The waveform applied to the electrode pair was a bipolar pulse with a frequency of 5.0 kHz and was used to reduce the charging current from measurement so that the current recorded at the end of one pulse is more representative of the solution conductivity. Using the detector, separations of amino acids, peptides, proteins, and oligonucleotides were demonstrated. For the amino acids and peptides, free-solution zone electrophoresis was performed. A calibration plot for the amino acid alanine was found to be linear from approximately 10 to 100 nM in a carrier electrolyte consisting of 10 mM triethylamonium acetate. The concentration detection limit was found to be 8.0 nM, with the corresponding mass detection limit equal to 3.4 amol (injection volume = 425 pL). The protein separations with conductivity detection were performed using MEKC, in which the carrier electrolyte contained the anionic surfactant sodium dodecyl sulfate (SDS) above its cmc. Near baseline resolution was achieved in the PMMA microchip for a solution containing 8 different proteins. In the case of the DNA fragments, capillary electrochromatography was used with a C18-modified PMMA chip and a carrier electrolyte containing an ion-pairing agent.

Amino Acids↗

Surface modification and characterization of microfabricated poly(carbonate) devices: manipulation of electroosmotic flow.

Poly(carbonate), PC, surfaces are chemically modified by treatment with sulfur trioxide gas. Sulfur trioxide gas sulfonates the aromatic rings of the poly(carbonate) surfaces, making the surfaces more hydrophilic. Sulfonation of the poly(carbonate) surface is confirmed by infrared spectroscopy. The modified polymer surfaces are found to be smoother in comparison to their unmodified counterparts, as noted by scanning force microscopy. The effects of the surface modification on electroosmotic flow are studied at a pH range of 4-10. The electroosmotic flow in sulfonated poly(carbonate) microchannels was found to be significantly higher than that in unmodified poly(carbonate) microchannels at pH values below 8.

Electrophoresis↗