The potential of inductively coupled plasma-mass spectrometric detection for capillary electrophoretic analysis of pesticides.

In this work, the potential of inductively coupled plasma-mass spectrometry (ICP-MS) coupled to capillary electrophoresis (CE) to determine organophosphorus pesticides (OPPs) is demonstrated. Element specific detection of (31)P with ICP-MS is performed for the detection of OPPs. Three common OPPs, including glyphosate, glufosinate, and aminomethylphosphonic acid (AMPA), were analyzed by CE-ICP-MS to demonstrate its applicability for the analysis of OPPs. The advantages of using ICP-MS with respect to other common detectors, such as flame photometric detection (FPD), for CE analysis of OPPs are shown. Additionally, different CE separation conditions were studied to achieve complete baseline separation of the pesticide compounds in short migration times. Two CE buffer systems were evaluated for the separation of OPPs using ICP-MS detection. A buffer solution containing 40 mmol.L(-1) ammonium acetate at pH 9.0 and an applied voltage of +20 kV were finally selected leading to a separation time of 10.0 min. Both migration time and area relative standard deviations (%RSD) were evaluated and their respective values were in the intervals of 1.1-3.3% and 2.7-5.3%. Detection limits obtained with the CE-ICP-MS system were in the range of 0.11-0.19 mg.L(-1) (as compound) yielding an enhancement of 130- to 230-fold with respect to FPD. The proposed methodology was finally applied for the determination of the OPPs mentioned above in natural river water samples.

Electrophoresis, Capillary↗

Hydride generation interface for speciation analysis coupling capillary electrophoresis to inductively coupled plasma mass spectrometry.

A novel hydride generation (HG) interface for coupling capillary electrophoresis (CE) with inductively coupled plasma mass spectrometry (ICPMS) is presented in this work. The CE-HG-ICPMS interface was applied to the separation and quantitation of common arsenic species. Lack of a commercially available HG interface for CE-ICPMS led to a three concentric tube design allowing alleviation of back pressure commonly observed in CE-HG-ICPMS. Due to the high sensitivity and element-specific detection of ICPMS, quantitative analysis of As(III), As(V), monomethylarsonic acid, and dimethylarsinic acid was achieved. Optimization of CE separation conditions resulted in the use of 20 mmol L(-1) sodium borate with 2% osmotic flow modifier (pH 9.0) and -20 kV applied potential for baseline resolution of each arsenic species in the shortest time. Hydride generation conditions were optimized through multiple electrophoretic separation analyses with 5% HCl and 3% NaBH(4) (in 0.2% NaOH) determined to be the optimum conditions. After completion of system optimization, detection limits obtained for the arsenic species were less than 40 ng L(-1) with electromigration time precision less than 1% within a total analysis time of 9.0 min. Finally, the interface was used for speciation analysis of arsenic in river and tap water samples.

Arsenic↗

Investigation of the elemental composition and chemical association of several elements in fulvic acids dietary supplements by size-exclusion chromatography UV inductively coupled plasma mass spectrometric.

Four fulvic acid dietary supplement samples were obtained for this study with the intention of investigating the elemental composition and association of fulvic acids found in fulvic acid supplements. This was achieved by coupling size-exclusion chromatography (SEC) sequentially with UV-vis and inductively coupled plasma mass spectrometric (ICP-MS) detectors. The combination of UV and ICP-MS offered highly sensitive and selective detection. This technique was used in the present study to initially investigate the chemical association of several different elements including, Cr, Co, Ca, Fe, I, Mg, Zn, Se, Cu, Mn, Mo, As, Hg, Pb, and Ag, by observing the elution profile of the fulvic acids obtained with UV detection and matching their retention times with the peaks measured with ICP-MS. The results found based on this type of analysis suggest that there was some association of the elements to the fulvic acids. It was also of interest to observe the stability of these complexes upon human digestion; therefore a gastric digestion was mimicked. In the fulvic acid dietary supplement samples studied, fulvic acids were present in the samples and there was elemental association based on the retention time overlap in the UV as well as the ICP-MS. The fulvic complexes found in the samples were of a low molecular weight As a result of the digestion the SEC-ICP-MS chromatographic profile in some of the samples changed, which may infer that the elemental association had changed.

Benzopyrans↗

Studies of various elements of nutritional and toxicological interest associated with different molecular weight fractions in Brazil nuts.

On-line hyphenation of size exclusion chromatography (SEC), UV, and inductively coupled plasma mass spectrometry (ICP-MS) was used to study the molecular weight distribution patterns of several elements in Brazil nuts (Bertholletia excelsa). This technique was used for the elemental speciation of different elements of nutritional and toxicological interests such as Mg, Fe, Co, Mo, Ag, Hg, and Pb. Elemental fractionation in Brazil nuts was studied using a Superdex peptide column with resolving capacity in the range of 14 to 0.18 kDa. Three different mobile phases, Tris buffer solution (pH 8.0), phosphate buffer (pH 7.5), and CAPS buffer solution (pH 10.0), were tried for the SEC fractionation. Size exclusion fractionation of all the extracted solutions was performed using a 50 mmol L(-)(1) Tris buffer (pH 8) as the mobile phase at a flow rate of 0.6 mL min(-)(1). Three different extractions, 0.05 mol L(-)(1) NaOH, 0.05 mol L(-)(1) HCl, and hot water at 60 degrees C, were performed, and the association of elements with various molecular weight fractions was evaluated. Total elemental concentrations in the extracted samples were determined and compared with the values obtained after total digestion to calculate the recovery values. Generally, high extraction efficiency was obtained with the NaOH solution as compared with HCl and hot water except in the case of magnesium, for which HCl was found to be a good extractant. Chromatographic elution profiles for these extractions were quite distinct from each other in most cases. Most of the elemental species were found to be associated with high molecular weight fractions. To study the differences obtained during the sample-processing step, the results obtained for nuts with shell were treated differently from those obtained for nuts purchased without shell and were compared.

Bertholletia↗

Speciation of nickel, copper, zinc, and manganese in different edible nuts: a comparative study of molecular size distribution by SEC-UV-ICP-MS.

Molecular size distribution patterns of Cu, Mn, Ni, and Zn were determined in several nut species by size-exclusion liquid chromatography (SEC) coupled on-line to UV and inductively coupled plasma mass spectrometry (ICP-MS) for detection. The molecular weight (MW) fractionation of the different metals was performed with a Superdex Peptide column, injecting 100 microL of the extracted solutions. The association of the elements with different MW fractions was observed with sequential detection by UV and ICP-MS. Various separation conditions were evaluated to obtain proper resolution and reproducible results with the size-exclusion column. Complete MW information of the elemental fractions in the nut samples was obtained within a retention time of 30 min. Fractionation of the above mentioned elements was done in nine different nut species commonly found in commercial markets. Variability of the fractionation patterns for two different extraction media, 0.05 mol L(-1) NaOH and 0.05 mol L(-1) HCl, was evaluated for every nut sample. Differences in the elemental fractionation patterns were found depending on the extraction procedure, nut species, and the type of element studied. It was also observed that the elements studied showed predominant association with high MW fractions when extracted with basic solution whereas with acidic extraction media only low MW fractions were obtained.

Chromatography, Liquid↗

Multielemental speciation analysis of fungi porcini (Boletus edulis) mushroom by size exclusion liquid chromatography with sequential on-line UV-ICP-MS detection.

An analytical methodology to determine the molecular weight (MW) distribution patterns of several elements among different compounds present in commonly consumed edible mushrooms is presented in this work. A hyphenated technique based on size exclusion liquid chromatography (SEC) coupled on-line to UV and inductively coupled plasma mass spectrometry (ICP-MS) detection was used. The association of the elements to high and low MW fractions was confirmed with sequential detection by UV and ICP-MS. Separation of the fractions was performed by injecting a 100 microL sample volume to a Superdex 75 column. The effect of different mobile phases on the separation was evaluated. Additionally, three different extraction conditions including 0.05 mol L(-1) NaOH, 0.05 mol L(-1) HCl, and hot water at 60 degrees C were applied to extract the elemental species from the mushroom samples. Significant differences were observed in the chromatograms depending on the extraction conditions utilized. Optimization of the experimental variables involved in the SEC-UV-ICP-MS coupling was carried out. The method was applied to investigate the fractionation patterns of Bi, Co, Cu, Fe, I, Mo, Ni, Se, and Zn in fungi porcini (Boletus edulis) mushroom. The results obtained in this work indicate an important association of most of the elements to high MW fractions.

Basidiomycota↗

Fast speciation analysis of iodophenol compounds in river waters by capillary electrophoresis-inductively coupled plasma-mass spectrometry with off-line solid-phase microextraction.

An analytical methodology for the fast separation and determination of iodophenol species in natural water samples was developed using capillary electrophoresis (CE) coupled to inductively coupled plasma-mass spectrometry (ICP-MS). Based on the element-specific and highly sensitive detection provided by ICP-MS, the methodology has been applied to the analysis of 2-iodophenol, 4-iodophenol, and 2,4,6-triiodophenol. The use of solid-phase microextraction (SPME), after proper optimization, improved the signal by a factor of 100 leading to detection limits in the sub microg.L(-1). Different desorption conditions of iodophenol compounds from the SPME microfiber were studied to achieve the optimum preconcentration factor and best analytical performance. Different CE conditions were studied to achieve complete baseline separation of iodophenols in short migration times. Three different CE buffer systems were evaluated using ICP-MS detection. A buffer solution containing 20 mmol.L(-1) 3-(cyclohexylamino)-1-propanesulfonic acid (CAPS) and an applied potential of +22 kV were finally selected leading to a maximum separation time of 6.6 min. A relative standard deviation (%RSD) of about 5.0% for ten consecutive determinations was obtained. Finally, the speciation methodology developed was utilized for the determination of iodophenol compounds in natural water samples.

Buffers↗

On-line preconcentration and determination of chromium in parenteral solutions by flow injection-flame atomic absorption spectrometry.

An on-line chromium preconcentration and determination system implemented with flame atomic absorption spectrometry (FAAS) associated to flow injection (FI) was studied. For the retention of chromium, 4-(2-Thiazolylazo)-resorcinol (TAR) and Amberlite XAD-16 were used, at pH 5.0. The Cr-TAR complex was removed from the micro-column with ethanol. An enrichment factor of 50 was obtained for the preconcentration of 50 ml of sample solution. The detection limit value for the preconcentration of 50 ml of aqueous solution of Cr was 20 ng l(-1). The precision for ten replicate determinations at the 5 microg l(-1) Cr levels was 2.9% relative standard deviation (RSD), calculated from the peak heights obtained. The calibration graph using the preconcentration system for chromium was linear with a correlation coefficient of 0.9997 at levels near the detection limits up to at least 100 microg l(-1). The method was successfully applied to the determination of chromium in parenteral solution samples.

Buffers↗

Trace humic and fulvic acid determination in natural water by cloud point extraction/preconcentration using non-ionic and cationic surfactants with FI-UV detection.

A preconcentration and determination method for humic and fulvic acids at trace levels in natural water samples was developed. Cloud point extraction was successfully employed for the preconcentration of humic acid (HA) and fulvic acid (FA) prior to the determination by using a flow injection (FI) system coupled to a spectrophotometric UV-Vis detector. The quantitative extraction of HA and FA within the pH range 1-12 was obtained by neutralization of the anionic charge on the humic substances with a cationic surfactant, hexadecyltrimethylammonium bromide (CTAB). This generated a hydrophobic species that was subsequently incorporated (solubilized) into the micelles of a non-ionic surfactant polyethylene glycol, tert-octylphenyl ether (Triton X-114). The FI method for HA and FA determination was developed by injection of 100 microl of the extracted surfactant-rich phase using an HPLC pump with spectrophotometric detection at 350 nm. A 50 ml sample solution preconcentration allowed an enrichment factor of 167. The limit of detection (LOD) obtained under the optimal conditions was 5 microg l(-1). The precision for ten replicate determinations at 0.2 mg l(-1) HA was 3.1% relative standard deviation (RSD), calculated from the peak heights. The calibration using the preconcentration system for HA and FA was linear with a correlation coefficient (r2) of 0.9997 at levels near the detection limits up to at least 1 mg l(-1). The method was successfully applied to the determination of HA and FA in natural water samples (river water).

Benzopyrans↗

Determination of cobalt in urine by FI-ICP-AES with online preconcentration.

A method for the preconcentration and determination of cobalt in human urine samples was developed. The online preconcentration and determination were attained using inductively coupled plasma atomic emission spectromety (ICP-AES) coupled to a flow injection (FI) method. Cobalt was retained on an Amberlite XAD-7 resin as cobalt-2-(5-bromo-2-pyridylazo)-5-diethylaminophenol complex at pH 9.5. Cobalt was removed from the microcolumn with perchloric acid. A sensitivity enhancement factor of 90 was obtained with respect to cobalt determination by ICP-AES without preconcentration. The value of detection limit for the preconcentration method proposed was 25 ng/L. The precision for 10 replicate determinations at the 5 mg/L (mean +/- SD, 5.1 +/- 0.14) Co level was 2.7% relative standard deviation, calculated from the peak heights obtained. The calibration graph preconcentration method for cobalt was linear with a correlation coefficient of 0.9994 from approximately 0.25 mg/L up to at least 100 mg/L. The method was successfully applied to the determination of cobalt in human urine samples.

Calibration↗

Modeling and separation-detection methods to evaluate the speciation of metals for toxicity assessment.

There is an increasing appreciation for the importance of speciation in the assessment of metal toxicity. In this review, two approaches to speciation are discussed, with an emphasis on their application to biological samples. One approach is the direct separation and detection of metal species of toxicological interest. Various "hyphenated" techniques, consisting of a chromatographic system coupled to inductively coupled plasma-mass spectrometry (ICP-MS), are discussed. The chromatographic strategies employed for separation emphasize liquid chromatography (LC), but the increasing use of gas chromatography (GC) and capillary electrophoresis (CE) in speciation analysis is discussed. The second approach to speciation is the use of computer models to calculate the speciation of a metal ion within a complex mixture of ligands. This approach is applicable to systems in which the metal cation exchanges ligands rapidly, so that the sample represents an equilibrium mixture of metal complexes. These computational models are based on the equilibrium constants for the metal complexes and a series of mass balance equations and give the distribution of metal complexes in the original sample. This approach is illustrated using the speciation of Al(III) in serum as an example.

Aluminum↗

On-line preconcentration and determination of cadmium in honey using knotted reactor coupled to flow injection-flame atomic absorption spectrometry.

An on-line cadmium preconcentration and determination system implemented with flame atomic absorption spectrometry (FAAS) associated with flow injection was studied. Cadmium was retained as Cd-2-(5-bromo-2-pyridylazo)-5-diethylaminophenol Cd-(5-Br-PADAP) complex, pH 9.3. The Cd complex was removed from the knotted reactor (KR) with ethanol. A total enhancement factor of 140 was obtained with respect to FAAS (40 for KR and 3.5 due to the use of ethanol) with preconcentration time of 120 s. The detection limit value for preconcentration of 1 g sample was 0.5 ng/g. The repeatability for 10 replicate determinations at 5.0 ng/g Cd level was 3.5% relative standard deviation, calculated from peak heights obtained. The calibration graph using the preconcentration system for Cd was linear with a correlation coefficient of 0.9990 at levels near the detection limits to at least 2000 ng/g. The method was successfully applied to determination of total Cd in honey samples.

Animals↗